938 resultados para electrical power equipments
Resumo:
This paper presents a new technique for the detectionof islanding conditions in electrical power systems. This problem isespecially prevalent in systems with significant penetrations of distributedrenewable generation. The proposed technique is based onthe application of principal component analysis (PCA) to data setsof wide-area frequency measurements, recorded by phasor measurementunits. The PCA approach was able to detect islandingaccurately and quickly when compared with conventional RoCoFtechniques, as well as with the frequency difference and change-ofangledifference methods recently proposed in the literature. Thereliability and accuracy of the proposed PCA approach is demonstratedby using a number of test cases, which consider islandingand nonislanding events. The test cases are based on real data,recorded from several phasor measurement units located in theU.K. power system.
Resumo:
Tidal turbines have been tested extensively at many scales in steady state flow. Testing medium- or full-scale devices in turbulent flow has been less thoroughly examined. The differences between turbine performances in these two different states are needed for testing method verification and numerical model validation. The work in this paper documents the performance of a 1/10 scale turbine in steady state pushing tests and tidal moored tests. The overall performance of the device appears to decrease with turbulent flow, though there is increased data scatter and therefore, reduced uncertainty. At maximum power performance, as velocity increases the mechanical power and electrical power reduction from steady to unsteady flow increases. The drive train conversion efficiency also decreases. This infers that the performance for this turbine design is affected by the presence of turbulent flow.
Resumo:
High Voltage Direct Current (HVDC) lines allow large quantities of power to be
transferred between two points in an electrical power system. A Multi-Terminal HVDC (MTDC) grid consists of a meshed network of HVDC lines, and this allows energy reserves to be shared between a number of AC areas in an efficient manner. Secondary Frequency Control (SFC) algorithms return the frequencies in areas connected by AC or DC lines to their original setpoints after Primary Frequency Controllers have been called following a contingency. Where multiple
TSOs are responsible for different parts of a MTDC grid it may not be possible to implement SFC from a centralised location. Thus, in this paper a simple gain based distributed Model Predictive Control strategy is proposed for Secondary Frequency Control of MTDC grids which allows TSOs to cooperatively perform SFC without the need for centralised coordination.
Resumo:
Insulated gate bipolar transistor (IGBT) modules are important safety critical components in electrical power systems. Bond wire lift-off, a plastic deformation between wire bond and adjacent layers of a device caused by repeated power/thermal cycles, is the most common failure mechanism in IGBT modules. For the early detection and characterization of such failures, it is important to constantly detect or monitor the health state of IGBT modules, and the state of bond wires in particular. This paper introduces eddy current pulsed thermography (ECPT), a nondestructive evaluation technique, for the state detection and characterization of bond wire lift-off in IGBT modules. After the introduction of the experimental ECPT system, numerical simulation work is reported. The presented simulations are based on the 3-D electromagnetic-thermal coupling finite-element method and analyze transient temperature distribution within the bond wires. This paper illustrates the thermal patterns of bond wires using inductive heating with different wire statuses (lifted-off or well bonded) under two excitation conditions: nonuniform and uniform magnetic field excitations. Experimental results show that uniform excitation of healthy bonding wires, using a Helmholtz coil, provides the same eddy currents on each, while different eddy currents are seen on faulty wires. Both experimental and numerical results show that ECPT can be used for the detection and characterization of bond wires in power semiconductors through the analysis of the transient heating patterns of the wires. The main impact of this paper is that it is the first time electromagnetic induction thermography, so-called ECPT, has been employed on power/electronic devices. Because of its capability of contactless inspection of multiple wires in a single pass, and as such it opens a wide field of investigation in power/electronic devices for failure detection, performance characterization, and health monitoring.
Resumo:
This paper proposes a new thermography-based maximum power point tracking (MPPT) scheme to address photovoltaic (PV) partial shading faults. Solar power generation utilizes a large number of PV cells connected in series and in parallel in an array, and that are physically distributed across a large field. When a PV module is faulted or partial shading occurs, the PV system sees a nonuniform distribution of generated electrical power and thermal profile, and the generation of multiple maximum power points (MPPs). If left untreated, this reduces the overall power generation and severe faults may propagate, resulting in damage to the system. In this paper, a thermal camera is employed for fault detection and a new MPPT scheme is developed to alter the operating point to match an optimized MPP. Extensive data mining is conducted on the images from the thermal camera in order to locate global MPPs. Based on this, a virtual MPPT is set out to find the global MPP. This can reduce MPPT time and be used to calculate the MPP reference voltage. Finally, the proposed methodology is experimentally implemented and validated by tests on a 600-W PV array.
Resumo:
This paper presents a multi-agent system approach to address the difficulties encountered in traditional SCADA systems deployed in critical environments such as electrical power generation, transmission and distribution. The approach models uncertainty and combines multiple sources of uncertain information to deliver robust plan selection. We examine the approach in the context of a simplified power supply/demand scenario using a residential grid connected solar system and consider the challenges of modelling and reasoning with
uncertain sensor information in this environment. We discuss examples of plans and actions required for sensing, establish and discuss the effect of uncertainty on such systems and investigate different uncertainty theories and how they can fuse uncertain information from multiple sources for effective decision making in
such a complex system.
Resumo:
Economic dispatch (ED) problems often exhibit non-linear, non-convex characteristics due to the valve point effects. Further, various constraints and factors, such as prohibited operation zones, ramp rate limits and security constraints imposed by the generating units, and power loss in transmission make it even more challenging to obtain the global optimum using conventional mathematical methods. Meta-heuristic approaches are capable of solving non-linear, non-continuous and non-convex problems effectively as they impose no requirements on the optimization problems. However, most methods reported so far mainly focus on a specific type of ED problems, such as static or dynamic ED problems. This paper proposes a hybrid harmony search with arithmetic crossover operation, namely ACHS, for solving five different types of ED problems, including static ED with valve point effects, ED with prohibited operating zones, ED considering multiple fuel cells, combined heat and power ED, and dynamic ED. In this proposed ACHS, the global best information and arithmetic crossover are used to update the newly generated solution and speed up the convergence, which contributes to the algorithm exploitation capability. To balance the exploitation and exploration capabilities, the opposition based learning (OBL) strategy is employed to enhance the diversity of solutions. Further, four commonly used crossover operators are also investigated, and the arithmetic crossover shows its efficiency than the others when they are incorporated into HS. To make a comprehensive study on its scalability, ACHS is first tested on a group of benchmark functions with a 100 dimensions and compared with several state-of-the-art methods. Then it is used to solve seven different ED cases and compared with the results reported in literatures. All the results confirm the superiority of the ACHS for different optimization problems.
Resumo:
A simple yet efficient harmony search (HS) method with a new pitch adjustment rule (NPAHS) is proposed for dynamic economic dispatch (DED) of electrical power systems, a large-scale non-linear real time optimization problem imposed by a number of complex constraints. The new pitch adjustment rule is based on the perturbation information and the mean value of the harmony memory, which is simple to implement and helps to enhance solution quality and convergence speed. A new constraint handling technique is also developed to effectively handle various constraints in the DED problem, and the violation of ramp rate limits between the first and last scheduling intervals that is often ignored by existing approaches for DED problems is effectively eliminated. To validate the effectiveness, the NPAHS is first tested on 10 popular benchmark functions with 100 dimensions, in comparison with four HS variants and five state-of-the-art evolutionary algorithms. Then, NPAHS is used to solve three 24-h DED systems with 5, 15 and 54 units, which consider the valve point effects, transmission loss, emission and prohibited operating zones. Simulation results on all these systems show the scalability and superiority of the proposed NPAHS on various large scale problems.
Resumo:
This paper proposes a method for the detection and classification of multiple events in an electrical power system in real-time, namely; islanding, high frequency events (loss of load) and low frequency events (loss of generation). This method is based on principal component analysis of frequency measurements and employs a moving window approach to combat the time-varying nature of power systems, thereby increasing overall situational awareness of the power system. Numerical case studies using both real data, collected from the UK power system, and simulated case studies, constructed using DigSilent PowerFactory, for islanding events, as well as both loss of load and generation dip events, are used to demonstrate the reliability of the proposed method.
Resumo:
This paper presents a new and efficient methodology for distribution network reconfiguration integrated with optimal power flow (OPF) based on a Benders decomposition approach. The objective minimizes power losses, balancing load among feeders and subject to constraints: capacity limit of branches, minimum and maximum power limits of substations or distributed generators, minimum deviation of bus voltages and radial optimal operation of networks. The Generalized Benders decomposition algorithm is applied to solve the problem. The formulation can be embedded under two stages; the first one is the Master problem and is formulated as a mixed integer non-linear programming problem. This stage determines the radial topology of the distribution network. The second stage is the Slave problem and is formulated as a non-linear programming problem. This stage is used to determine the feasibility of the Master problem solution by means of an OPF and provides information to formulate the linear Benders cuts that connect both problems. The model is programmed in GAMS. The effectiveness of the proposal is demonstrated through two examples extracted from the literature.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo de Automação e Eletrónica Industrial
Resumo:
The non-technical loss is not a problem with trivial solution or regional character and its minimization represents the guarantee of investments in product quality and maintenance of power systems, introduced by a competitive environment after the period of privatization in the national scene. In this paper, we show how to improve the training phase of a neural network-based classifier using a recently proposed meta-heuristic technique called Charged System Search, which is based on the interactions between electrically charged particles. The experiments were carried out in the context of non-technical loss in power distribution systems in a dataset obtained from a Brazilian electrical power company, and have demonstrated the robustness of the proposed technique against with several others natureinspired optimization techniques for training neural networks. Thus, it is possible to improve some applications on Smart Grids.
Resumo:
Atualmente a energia é considerada um vetor estratégico nas diversas organizações. Assim sendo, a gestão e a utilização racional da energia são consideradas instrumentos fundamentais para a redução dos consumos associados aos processos de produção do sector industrial. As ações de gestão energética não deverão ficar pela fase do projeto das instalações e dos meios de produção, mas sim acompanhar a atividade da Empresa. A gestão da energia deve ser sustentada com base na realização regular de diagnósticos energéticos às instalações consumidoras e concretizada através de planos de atuação e de investimento que apresentem como principal objetivo a promoção da eficiência energética, conduzindo assim à redução dos respetivos consumos e, consequentemente, à redução da fatura energética. Neste contexto, a utilização de ferramentas de apoio à gestão de energia promovem um consumo energético mais racional, ou seja, promovem a eficiência energética e é neste sentido que se insere este trabalho. O presente trabalho foi desenvolvido na Empresa RAR Açúcar e apresentou como principais objetivos: a reformulação do Sistema de Gestão de Consumos de Energia da Empresa, a criação de um modelo quantitativo que permitisse ao Gestor de Energia prever os consumos anuais de água, fuelóleo e eletricidade da Refinaria e a elaboração de um plano de consumos para o ano de 2014 a partir do modelo criado. A reformulação do respetivo Sistema de Gestão de Consumos resultou de um conjunto de etapas. Numa primeira fase foi necessário efetuar uma caraterização e uma análise do atual Sistema de Gestão de Consumos da Empresa, sistema composto por um conjunto de sete ficheiros de cálculo do programa Microsoft Excel©. Terminada a análise, selecionada a informação pertinente e propostas todas as melhorias a introduzir nos ficheiros, procedeu-se à reformulação do respetivo SGE, reduzindo-se o conjunto de ficheiros de cálculo para apenas dois ficheiros, um onde serão efetuados e visualizados todos os registos e outro onde serão realizados os cálculos necessários para o controlo energético da Empresa. O novo Sistema de Gestão de Consumos de Energia será implementado no início do ano de 2015. Relativamente às alterações propostas para as folhas de registos manuais, estas já foram implementadas pela Empresa. Esta aplicação prática mostrou-se bastante eficiente uma vez que permitiu grandes melhorias processuais nomeadamente, menores tempos de preenchimento das mesmas e um encurtamento das rotas efetuadas diariamente pelos operadores. Através do levantamento efetuado aos diversos contadores foi possível identificar todas as áreas onde será necessário a sua instalação e a substituição de todos os contadores avariados, permitindo deste modo uma contabilização mais precisa de todos os consumos da Empresa. Com esta reestruturação o Sistema de Gestão de Consumos tornou-se mais dinâmico, mais claro e, principalmente, mais eficiente. Para a criação do modelo de previsão de consumos da Empresa foi necessário efetuar-se um levantamento dos consumos históricos de água, eletricidade, fuelóleo e produção de açúcar de dois anos. Após este levantamento determinaram-se os consumos específicos de água, fuelóleo e eletricidade diários (para cada semana dos dois anos) e procedeu-se à caracterização destes consumos por tipo de dia. Efetuada a caracterização definiu-se para cada tipo de dia um consumo específico médio com base nos dois anos. O modelo de previsão de consumos foi criado com base nos consumos específicos médios dos dois anos correspondentes a cada tipo de dia. Procedeu-se por fim à verificação do modelo, comparando-se os consumos obtidos através do modelo (consumos previstos) com os consumos reais de cada ano. Para o ano de 2012 o modelo apresenta um desvio de 6% na previsão da água, 12% na previsão da eletricidade e de 6% na previsão do fuelóleo. Em relação ao ano de 2013, o modelo apresenta um erro de 1% para a previsão dos consumos de água, 8% para o fuelóleo e de 1% para a eletricidade. Este modelo permitirá efetuar contratos de aquisição de energia elétrica com maior rigor o que conduzirá a vantagens na sua negociação e consequentemente numa redução dos custos resultantes da aquisição da mesma. Permitirá também uma adequação dos fluxos de tesouraria à necessidade reais da Empresa, resultante de um modelo de previsão mais rigoroso e que se traduz numa mais-valia financeira para a mesma. Foi também proposto a elaboração de um plano de consumos para o ano de 2014 a partir do modelo criado em função da produção prevista para esse mesmo ano. O modelo apresenta um desvio de 24% na previsão da água, 0% na previsão da eletricidade e de 28% na previsão do fuelóleo.
Resumo:
A presente tese tem como principal objectivo abordar o tema da eficiência energética em edifícios, no que se refere aos sistemas de climatização. O desenvolvimento deste projecto realizou-se em torno dos consumos energéticos dos diferentes sistemas de climatização estudados (e por conseguinte da envolvente do edifício), focando o cumprimento dos requisitos térmico e energéticos das normas vigentes (RCCTE e RSECE) em Portugal, tendo como objectivo identificar os parâmetros com maior impacto e a relação tendencial entre as soluções construtivas e tecnológicas adoptadas, sempre com o horizonte de maximizar a eficiência energética e diminuir a dependência face à energia primária e consequentemente a emissão de gases que provocam o efeito de estufa. É âmbito desta tese comparar diferentes tipos de sistemas de climatização a nível energético e torná-los os mais eficientes possíveis, para que também se possam tornar monetariamente aliciantes e aumentar o rácio entre benefício/custo. Para tal, numa primeira fase foi feito um estudo térmico da envolvente do edifício, tendo sido utilizado um software de simulação energética de edifícios acreditado pela norma ASHRAE 140-2004 para se poder compreender como o edifício se comportava ao longo do ano, e introduzir algumas correcções na respectiva envolvente, para baixar as potências térmicas/eléctricas dos equipamentos do sistema de AVAC. De seguida foram estudados três sistemas possíveis de climatização para o edifício, de modo a identificar o mais eficiente numa base anual, bem como a possibilidade de combinar o uso de fontes de energia renováveis com o intuito de satisfazer ao máximo as necessidades térmicas do edifício e, ainda, de minimizar o consumo de energia de origem não renovável. Por fim, para avaliar as diferentes potencialidades de cada sistema de climatização estudado, fez-se o respectivo estudo à sua viabilidade económica. Nas considerações finais da presente tese é realizado um estudo aos benefícios que uma possível alteração da arquitectura do edifício pode trazer no aumento da iluminação natural do mesmo integrado com um controlo da iluminação artificial necessária para os diferentes espaços climatizados. Os resultados obtidos foram comparados entre si e corrigir a envolvente exterior reduz os consumos energéticos do edifício em cerca de 11%. As medidas correctivas propostas no sistema de climatização base originam uma redução energética igual a 43%. A nível ambiental, é possível a redução do número de emissões de CO2 em cerca de 72.1%.