973 resultados para dobutamine stress testing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To compare currently available low-shrinkage composites with others regarding polymerization stress, volumetric shrinkage (total and post-gel), shrinkage rate and elastic modulus. Methods. Seven BisGMA-based composites (Durafill/DU, Filtek Z250/FZ, Heliomolar/HM, Aelite LS Posterior/AP, Point 4/P4, Filtek Supreme/SU, ELS/EL), a silorane-based (Filtek LS, LS), a urethane-based (Venus Diamond, VD) and one based on a dimethacrylate-derivative of dimer acid (N`Durance, ND) were tested. Polymerization stress was determined in 1-mm high specimens inserted between two PMMA rods attached to a universal testing machine. Total volumetric shrinkage was measured using a mercury dilatometer. Maximum shrinkage rate was used as a parameter of the reaction speed. Post-gel shrinkage was measured using strain-gages. Elastic modulus was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey test (p = 0.05), except for elastic modulus (Kruskal-Wallis). Results. Composites ranked differently for total and post-gel shrinkage. Among the materials considered as ""low-shrinkage"" by the respective manufacturers, LS, EL and VD presented low post-gel shrinkage, while AP and ND presented relatively high values. Polymerization stress showed a strong correlation with post-gel shrinkage except for LS, which presented high stress. Elastic modulus and shrinkage rate showed weak relationships with polymerization stress. Significance. Not all low-shrinkage composites demonstrated reduced polymerization shrinkage. Also, in order to effectively reduce polymerization stress, a low post-gel shrinkage must be associated to a relatively low elastic modulus. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Stress development at the tooth/restoration interface is one of the most important reasons for failure of adhesive restorations. The aim of this study was to evaluate the influence of BisGMA/TEGDMA (B/T) and UDMA/TEGDMA (U/T) ratios on polymerization stress (PS) and on the variables related to its development: degree of conversion (DC), polymerization maximum rate (Rp(max)), volumetric shrinkage (VS), elastic modulus (E), stress relaxation (SR) and viscosity of experimental composites. Method. Composites were formulated containing B/T or U/T in mol% ratios of 2: 8, 3: 7, 4: 6, 5: 5, 6: 4, 7: 3 and 8: 2, and 15 wt% of fumed silica. PS was determined with a universal testing machine. VS was measured with a linometer. E and SR were obtained in three-point bending. DC and Rp(max) were determined by real time NIR spectroscopy and viscosity was measured in viscometer. Data were submitted to one-way ANOVA, Tukey test (alpha = 0.05%) and regression analyses. Results. PS, VS, E and DC decreased and viscosity and Rp(max) increased with base monomer content in both series. PS showed strong correlation with VS, DC and viscosity. PS, VS and DC were higher and viscosity was lower for UDMA-based materials. Significance. Reduced viscosity, kinetics parameters and molecular characteristics led UDMA-based composites to elevated conversion and relatively lower PS at lower TEGDMA contents, compared to B/T composites. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. This study evaluated the degree of conversion (DC), maximum rate of cure (R(p)(max)), and polymerization stress (PS) developed by an experimental dental composite subjected to different irradiant energies (3,6,12, 24, or 48J/cm(2)) under constant irradiance (500 mw/cm(2)). Methods. DC and R(p)(max) were monitored for 10 min on the bottom surface of 2-mm thick disks and on 150-mu m thick films (representing the top of the specimen) using ATR-FTIR. PS was monitored for 10 min in 2-mm thick disks bonded to two glass rods (O = 5 mm) attached to a universal testing machine. One-way ANOVA/Tukey tests were used and differences in DC and R(p)(max) between top and bottom surfaces were examined using Student`s t-test. Statistical testing was performed at a pre-set alpha of 0.05. Results. For a given surface, DC showed differences among all groups, except at the top between 24 and 48 J/cm(2). R(p)(max) was similar among all groups at the same surface and statistically higher at the top surface. PS also showed significant differences among all groups. Data for 48 J/cm(2) were not obtained due to specimen failure at the glass/composite interface. Significance. Increases in irradiant exposure led to significant increases in DC and PS, but had no effect on R(p)(max) (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. Evaluate the effect of testing system compliance on polymerization stress and stress distribution of composites. Methods. Composites tested were Filtek Z250 (FZ), Herculite (HL), Tetric Ceram (TC), Helio Fill-AP (HF) and Heliomolar (HM). Stress was determined in 1-mm thick specimens, inserted between two rods of either poly(methyl methacrylate), PMMA, or glass. Experimental nominal stress (sigma(exp)) was calculated by dividing the maximum force recorded 5 min after photoactivation by the cross-sectional area of the rod. Composites` elastic modulus (E) was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey`s test (alpha = 0.05). Stress distribution on longitudinal (sigma(y)) and transverse (sigma(x)) axes of models representing the composites with the highest and lowest E (FZ and HM, respectively) were evaluated by finite element analysis (FEA). Results. sigma(exp) ranged from 5.5 to 8.8 MPa in glass and from 2.6 to 3.4 MPa in PMMA. Composite ranking was not identical in both substrates, since FZ showed or sigma(exp) statistically higher than HM in glass, while in PMMA FZ showed values similar to the other composites. A strong correlation was found between stress reduction (%) from glass to PMMA and composite`s E (r(2) = 0.946). FEA revealed that system compliance was influenced by the composite (FZ led to higher compliance than HM). sigma(x) distribution was similar in both substrates, while cry distribution showed larger areas of compressive stresses in specimens built on PMMA. Significance. sigma(exp) determined in PMMA was 53-68% lower than in glass. Composite ranking varied slightly due to differences in substrates` longitudinal and transverse deformation. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A combination of modelling and analysis techniques was used to design a six component force balance. The balance was designed specifically for the measurement of impulsive aerodynamic forces and moments characteristic of hypervelocity shock tunnel testing using the stress wave force measurement technique. Aerodynamic modelling was used to estimate the magnitude and distribution of forces and finite element modelling to determine the mechanical response of proposed balance designs. Simulation of balance performance was based on aerodynamic loads and mechanical responses using convolution techniques. Deconvolution was then used to assess balance performance and to guide further design modifications leading to the final balance design. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES We sought to find out whether dobutamine echocardiography (DbE) could provide independent prediction of total and cardiac mortality, incremental to clinical and angiographic variables. BACKGROUND Existing outcome studies with DbE have examined composite end points, rather than death, over a relatively short follow-up. METHODS Clinical and stress data were collected in 3,156 patients (age 63 +/- 12 years, 1,801 men) undergoing DbE. Significant stenoses (>50% diameter) were identified in 70% of 1,073 patients undergoing coronary angiography. Total and cardiac mortality were identified over nine years of follow-up (mean 3.8 +/- 1.9). Cox models were used to analyze the effect of ischemia and other variables, independent of other determinants of mortality. RESULTS The dobutamine echocardiogram was abnormal in 1,575 patients (50%). Death occurred in 716 patients (23%), 259 of whom (8%) were thought to have died from cardiac causes. Patients with normal DbE had a total mortality of 8% per year and a cardiac mortality of 1% per year over the first four years of follow-up. Ischemia and the extent of abnormal wall motion were independent predictors of cardiac death, together with age and heart failure. In sequential Cox models, the predictive power of clinical data alone (model chi-square 115) was strengthened by adding the resting left ventricular function (model chi-square 138) and the results of DbE (model chi-square 181). In the subgroup undergoing coronary angiography, the power of the model was increased to a minor degree by the addition of coronary anatomy data. CONCLUSIONS Dobutamine echocardiography is an independent predictor of death, incremental to other data. While a normal dobutamine echocardiogram predicts low risk of cardiac death ton the order of 1% per year), this risk increases with the extent of abnormal wall motion at rest and stress, (J Am Coil Cardiol 2001;37:754-60) (C) 2001 by the American College of Cardiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Tissue Doppler may be used to quantify regional left ventricular function but is limited by segmental variation of longitudinal velocity from base to apex and free to septal walls. We sought to overcome this by developing a composite of longitudinal and radial velocities. Methods and Results. We examined 82 unselected patients undergoing a standard dobutamine echocardiogram. Longitudinal velocity was obtained in the basal and mid segments of each wall using tissue Doppler in the apical views. Radial velocities were derived in the same segments using an automated border detection system and centerline method with regional chords grouped according to segment location and temporally averaged. In 25 patients at low probability of coronary disease, the pattern of regional variation in longitudinal velocity (higher in the septum) was the opposite of radial velocity (higher in the free wall) and the combination was homogenous. In 57 patients undergoing angiography, velocity in abnormal segments was less than normal segments using longitudinal (6.0 +/- 3.6 vs 9.0 +/- 2.2 cm/s, P = .01) and radial velocity (6.0 +/- 4.0 vs 8.0 +/- 3.9 cm/s, P = .02). However, the composite velocity permitted better separation of abnormal and normal segments (13.3 +/- 5.6 vs 17.5 +/- 4.2 cm/s, P = .001). There was no significant difference between the accuracy of this quantitative approach and expert visual wall motion analysis (81% vs 84%, P = .56). Conclusion: Regional variation of uni-dimensional myocardial velocities necessitates site-specific normal ranges, probably because of different fiber directions. Combined analysis of longitudinal and radial velocities allows the derivation of a composite velocity, which is homogenous in all segments and may allow better separation of normal and abnormal myocardium.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atualmente, o álcool tem um papel importante na saúde pública e surge como um dos principais problemas sociais no mundo, dado que é a droga mais viciante aceite em encontros sociais. Provavelmente, por essa razão, os riscos do consumo abusivo do álcool são subestimados pelos jovens, mulheres grávidas e idosos. O álcool, quando ingerido em altas proporções, pode afetar todos os órgãos e desencadear inúmeras doenças, tais como a doença cardíaca coronariana, doença neurodegenerativa, as doenças crónicas e câncer. O álcool afeta ainda o estado psicológico, induzindo a violência, o estado antissocial e situações de risco de comportamentos. Por estas razões, o álcool tornou-se um foco principal da investigação, avaliando os seus efeitos sobre o corpo humano. Nesta pesquisa, foram suscitadas amostras de sangue de um grupo de pacientes em tratamento psicológico e/ou farmacêutico que serão analisadas com quatro métodos: Teste de Radicais Livres do Oxigénio (FORT), Defesa contra Radicais Livres do Oxigénio (FORD), cromatografia gasosa (GC) e cromatografia líquida de alta pressão (HPLC). Ambos os métodos FORT e FORD avaliam o stress oxidativo pela quantificação de radicais livres e a capacidade de antioxidantes em eliminar esses radicais livres, respetivamente. O stress oxidativo é o efeito do excesso de consumo de álcool, que é reduzido pela capacidade de ação dos antioxidantes. A boa reprodutibilidade, precisão e exatidão de ambos os métodos indicam que estes podem ser aplicados em rápidos diagnósticos. Para o método FORT e considerando o início do tratamento, os pacientes alcoólicos apresentaram uma média de 3,59±1.01mmol/LH2O2 e o grupo de controlo uma média de 1,42±0.53mmol/LH2O2, o que mostra uma diferença significativa entre os dois grupos (P=0,0006). Para o método FORD, pacientes alcoólicos apresentam uma média de 1,07±0.53mmol/LH2O2 e o grupo de controlo, uma média de 2,81±0.46mmol/LH2O2, mostrando também uma média significativa (P=0,0075). Após 15 dias de tratamento observou-se que há uma diferença entre os dois grupos de pacientes alcoólicos, mas não há nenhum melhoramento em relação ao grupo de pacientes em tratamento. No método FORT os grupos mostram uma diferença significativa (P=0,0073), tendo os pacientes sem tratamento farmacêutico melhores resultados (2.37±0.44mmol/LH2O2) do que os pacientes com tratamento (3.72±1,04mmol/LH2O2). O oposto ocorre no método FORD, os pacientes em tratamento farmacêutico presentam melhores resultados (1.16±0.65mmol/LH2O2) do que o outro grupo (0.75±0.22mmol/LH2O2), não sendo, no entanto, uma diferença significativa entre os dois grupos (P=0.16). Os resultados obtidos para a concentração de MDA pelo método de HPLC mostraram que o grupo de controlo tem valores mais baixos do que os pacientes alcoólicos, embora a diferença não seja muito significativa (P = 0,084), mas é ainda elevada. Além disso, os dois grupos de pacientes não apresentaram uma diferença significativa entre os seus resultados no início (P=0,77) e no fim (P=0,79) do tratamento. De acrescentar ainda que, os resultados da concentração de álcool no sangue determinados pelo método de CG mostraram que só alguns pacientes sem tratamento consumiram álcool durante o período de tratamento, o que influencia negativamente a conclusão sobre o efeito do tratamento. Contudo, outros fatores externos podem ainda influenciar os resultados finais, tais como o estado nutricional e estado psicológico dos pacientes, se o paciente continua a beber durante o tempo de tratamento ou até mesmo se o paciente é exposto a outros tipos de substâncias nocivas. Existe ainda a possibilidade de o tempo de aplicação do tratamento não ser suficiente para apresentar um efeito positivo em relação ao stress oxidativo e este é um outro fator que contribui para a impossibilidade de confirmar sobre o efeito, quer seja positivo ou negativo, do tratamento antioxidante.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, an experimental study was performed on the influence of plug-filling, loading rate and temperature on the tensile strength of single-strap (SS) and double-strap (DS) repairs on aluminium structures. Whilst the main purpose of this work was to evaluate the feasibility of plug-filling for the strength improvement of these repairs, a parallel study was carried out to assess the sensitivity of the adhesive to external features that can affect the repairs performance, such as the rate of loading and environmental temperature. The experimental programme included repairs with different values of overlap length (L O = 10, 20 and 30 mm), and with and without plug-filling, whose results were interpreted in light of experimental evidence of the fracture modes and typical stress distributions for bonded repairs. The influence of the testing speed on the repairs strength was also addressed (considering 0.5, 5 and 25 mm/min). Accounting for the temperature effects, tests were carried out at room temperature (≈23°C), 50 and 80°C. This permitted a comparative evaluation of the adhesive tested below and above the glass transition temperature (T g), established by the manufacturer as 67°C. The combined influence of these two parameters on the repairs strength was also analysed. According to the results obtained from this work, design guidelines for repairing aluminium structures were

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work tubular fiber reinforced specimens are tested for fatigue life. The specimens are biaxially loaded with tension and shear stresses, with a load angle β of 30° and 60° and a load ratio of R=0,1. There are many factors that affect fatigue life of a fiber reinforced material and the main goal of this work is to study the effects of load ratio R by obtaining S-N curves and compare them to the previous works (1). All the other parameters, such as specimen production, fatigue loading frequency and temperature, will be the same as for the previous tests. For every specimen, stiffness, temperature of the specimen during testing, crack counting and final fracture mode are obtained. Prior to testing, a study if the literature regarding the load ratio effects on composites fatigue life and with that review estimate the initial stresses to be applied in testing. In previous works (1) similar specimens have only been tested for a load ratio of R=-1 and therefore the behaviour of this tubular specimens for a different load ratio is unknown. All the data acquired will be analysed and compared to the previous works, emphasizing the differences found and discussing the possible explanations for those differences. The crack counting software, developed at the institute, has shown useful before, however different adjustments to the software parameters lead to different cracks numbers for the same picture, and therefore a better methodology will be discussed to improve the crack counting results. After the specimen’s failure, all the data will be collected and stored and fibre volume content for every specimen is also determinate. The number of tests required to make the S-N curves are obtained according to the existent standards. Additionally are also identified some improvements to the testing machine setup and to the procedures for future testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atualmente, o álcool tem um papel importante na saúde pública e surge como um dos principais problemas sociais no mundo, dado que é a droga mais viciante aceite em encontros sociais. Provavelmente, por essa razão, os riscos do consumo abusivo do álcool são subestimados pelos jovens, mulheres grávidas e idosos. O álcool, quando ingerido em altas proporções, pode afetar todos os órgãos e desencadear inúmeras doenças, tais como a doença cardíaca coronariana, doença neurodegenerativa, as doenças crónicas e câncer. O álcool afeta ainda o estado psicológico, induzindo a violência, o estado antissocial e situações de risco de comportamentos. Por estas razões, o álcool tornou-se um foco principal da investigação, avaliando os seus efeitos sobre o corpo humano. Nesta pesquisa, foram suscitadas amostras de sangue de um grupo de pacientes em tratamento psicológico e/ou farmacêutico que serão analisadas com quatro métodos: Teste de Radicais Livres do Oxigénio (FORT), Defesa contra Radicais Livres do Oxigénio (FORD), cromatografia gasosa (GC) e cromatografia líquida de alta pressão (HPLC). Ambos os métodos FORT e FORD avaliam o stress oxidativo pela quantificação de radicais livres e a capacidade de antioxidantes em eliminar esses radicais livres, respetivamente. O stress oxidativo é o efeito do excesso de consumo de álcool, que é reduzido pela capacidade de ação dos antioxidantes. A boa reprodutibilidade, precisão e exatidão de ambos os métodos indicam que estes podem ser aplicados em rápidos diagnósticos. Para o método FORT e considerando o início do tratamento, os pacientes alcoólicos apresentaram uma média de 3,59±1.01mmol/LH2O2 e o grupo de controlo uma média de 1,42±0.53mmol/LH2O2, o que mostra uma diferença significativa entre os dois grupos (P=0,0006). Para o método FORD, pacientes alcoólicos apresentam uma média de 1,07±0.53mmol/LH2O2 e o grupo de controlo, uma média de 2,81±0.46mmol/LH2O2, mostrando também uma média significativa (P=0,0075). Após 15 dias de tratamento observou-se que há uma diferença entre os dois grupos de pacientes alcoólicos, mas não há nenhum melhoramento em relação ao grupo de pacientes em tratamento. No método FORT os grupos mostram uma diferença significativa (P=0,0073), tendo os pacientes sem tratamento farmacêutico melhores resultados (2.37±0.44mmol/LH2O2) do que os pacientes com tratamento (3.72±1,04mmol/LH2O2). O oposto ocorre no método FORD, os pacientes em tratamento farmacêutico presentam melhores resultados (1.16±0.65mmol/LH2O2) do que o outro grupo (0.75±0.22mmol/LH2O2), não sendo, no entanto, uma diferença significativa entre os dois grupos (P=0.16). Os resultados obtidos para a concentração de MDA pelo método de HPLC mostraram que o grupo de controlo tem valores mais baixos do que os pacientes alcoólicos, embora a diferença não seja muito significativa (P = 0,084), mas é ainda elevada. Além disso, os dois grupos de pacientes não apresentaram uma diferença significativa entre os seus resultados no início (P=0,77) e no fim (P=0,79) do tratamento. De acrescentar ainda que, os resultados da concentração de álcool no sangue determinados pelo método de CG mostraram que só alguns pacientes sem tratamento consumiram álcool durante o período de tratamento, o que influencia negativamente a conclusão sobre o efeito do tratamento. Contudo, outros fatores externos podem ainda influenciar os resultados finais, tais como o estado nutricional e estado psicológico dos pacientes, se o paciente continua a beber durante o tempo de tratamento ou até mesmo se o paciente é exposto a outros tipos de substâncias nocivas. Existe ainda a possibilidade de o tempo de aplicação do tratamento não ser suficiente para apresentar um efeito positivo em relação ao stress oxidativo e este é um outro fator que contribui para a impossibilidade de confirmar sobre o efeito, quer seja positivo ou negativo, do tratamento antioxidante.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract ST2 is a member of the interleukin-1 receptor family biomarker and circulating soluble ST2 concentrations are believed to reflect cardiovascular stress and fibrosis. Recent studies have demonstrated soluble ST2 to be a strong predictor of cardiovascular outcomes in both chronic and acute heart failure. It is a new biomarker that meets all required criteria for a useful biomarker. Of note, it adds information to natriuretic peptides (NPs) and some studies have shown it is even superior in terms of risk stratification. Since the introduction of NPs, this has been the most promising biomarker in the field of heart failure and might be particularly useful as therapy guide.