871 resultados para disposable contact lenses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To characterize toric contact lens prescribing worldwide. Methods Up to 1,000 survey forms were sent to contact lens fitters in up to 39 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for toric and spherical soft lens fits were analyzed. Survey data collected since 1996 were also analyzed for 7 nations to assess toric lens fitting trends since that time. Results Data were collected in relation to 21,150 toric fits (25%) and 62,150 spherical fits (75%). Toric prescribing ranged from 6% of lenses in Russia to 48% in Portugal. Compared with spherical fittings, toric fittings can be characterized as follows: older age (29.8 ± 11.4 years vs. 27.6 ± 10.8 years for spherical lenses); men are overrepresented (38% vs. 34%); greater proportion of new fits (39% vs. 32%); use of silicone hydrogel lenses (49% vs. 39%); and lower proportion of daily disposable lenses (14% vs. 28%). There has been a continuous increase in toric lens prescribing between 1996 and 2011. The proportion of toric lens fits was positively related to the gross domestic product at purchasing power parity per capita for year 2011 (r2 = 0.21; P=0.004). Conclusions At the present time, in the majority of countries surveyed, toric soft contact lens prescribing falls short of that required to correct clinically significant astigmatism (≥0.75 diopters) in all lens wearers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To characterize and discover the determinants of the frequency of wear (FOW) of contact lenses. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for daily wear lens fits were analyzed. Results Data were collected in relation to 74,510 and 9,014 soft and rigid lens fits, respectively. Overall, FOW was 5.9±1.7 days per week (DPW). When considering the proportion of lenses worn between one to seven DPW, the distribution for rigid lenses is skewed toward full-time wear (7 DPW), whereas the distribution for soft daily disposable lenses is perhaps bimodal, with large and small peaks at seven and two DPW, respectively. There is a significant variation in FOW among nations (P<0.0001), ranging from 6.8±1.0 DPW in Greece to 5.1±2.5 DPW in Kuwait. For soft lenses, FOW increases with decreasing age. Females (6.0±1.6 DPW) wear lenses more frequently than males (5.8±1.7 DPW) (P=0.0002). FOW is greater among those wearing presbyopic corrections (6.1±1.4 DPW) compared with spherical (5.9±1.7 DPW) and toric (5.9±1.6 DPW) designs (P<0.0001). FOW with hydrogel peroxide systems (6.4±1.1 DPW) was greater than that with multipurpose systems (6.2±1.3 DPW) (P<0.0001). Conclusions Numerous demographic and contact lens–related factors impact FOW. There may be a future trend toward a lower FOW associated with the increasing popularity of daily disposable lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We sought to determine the impact of optometric practice setting on contact lens prescribing by analysing annual survey data of lens fits collected between 2009 and 2013 from independent and national group practices throughout the United Kingdom. Compared to national group practices, independent practices fit contact lenses to older patients and more females. Independent practices also undertake a lower proportion of soft lens fits overall (and thus a higher proportion of rigid lens fits), soft toric lens fits and daily disposable lens fits. There is a higher proportion of soft extended wear and multifocal lens fits in independent practices. We conclude that contact lens fitting behaviour is influenced by optometric practice setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose:  The aim was to document contact lens prescribing trends in Australia between 2000 and 2009.

Methods:  A survey of contact lens prescribing trends was conducted each year between 2000 and 2009. Australian optometrists were asked to provide information relating to 10 consecutive contact lens fittings between January and March each year.

Results:  Over the 10-year survey period, 1,462 practitioners returned survey forms representing a total of 13,721 contact lens fittings. The mean age (± SD) of lens wearers was 33.2 ± 13.6 years and 65 per cent were female. Between 2006 and 2009, rigid lens new fittings decreased from 18 to one per cent. Low water content lenses reduced from 11.5 to 3.2 per cent of soft lens fittings between 2000 and 2008. Between 2005 and 2009, toric lenses and multifocal lenses represented 26 and eight per cent, respectively, of all soft lenses fitted. Daily disposable, one- to two-week replacement and monthly replacement lenses accounted for 11.6, 30.0 and 46.5 per cent of all soft lens fittings over the survey period, respectively. The proportion of new soft fittings and refittings prescribed as extended wear has generally declined throughout the past decade. Multi-purpose lens care solutions dominate the market. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full-time basis, whereas daily disposable soft lenses are mainly worn part-time.

Conclusions:  This survey indicates that technological advances, such as the development of new lens materials, manufacturing methods and lens designs, and the availability of various lens replacement options, have had a significant impact on the contact lens market during the first decade of the 21st Century.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The objectives of this study were to assess current recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses, to determine compliance with these recommendations, and to investigate the reasons given for noncompliance.

Methods: A package containing 20 patient surveys was sent to 309 eye care practitioners (ECPs) in the United States who had agreed to participate in the study. One thousand eight hundred fifty-nine completed surveys were received from 158 ECPs and 1,654 surveys were eligible for analysis. Questions related to patient demographics, lens type, lens wearing patterns, the ECP instructions for RF, and the actual patient reported RF. ECPs were asked to provide lens information and their recommendation for RF after the surveys had been completed and sealed in envelopes. All responses were anonymous.

Results: Sixty-six percent of patients were women and their mean age was 34 ± 12 years. Eighty-eight percent of lenses were worn for daily wear, 12.8 ± 3.2 hours a day, 6.2 ± 1.5 days a week. Lens type distribution was 16% DD, 45% 2 week (2W) SH, and 39% 1 month (1M) SH. ECP recommendations for RF varied according to the lens type; 1% of 1M (95% CI 0.2-1.7), 4% of DD (95% CI 2.1-7.2), and 18% of 2W (95% CI 15.1-20.7) patients were given instructions that did not conform to the manufacturers' recommended RF (MRRF). When considering only those patients who were given the correct instructions for RF, 38% were not compliant with the MRRF; noncompliance rates varied according to the lens type and were 12% for DD (95% CI 8.6-17.2), 28% for 1M (95% CI 24.9-32.1), and 52% for 2W (95% CI 47.8-55.8). The most frequent reasons for over wearing lenses were forgetting which day to replace lenses (51%) and to save money (26%). Fifty-three percent believed that a reminder system would aid compliance; the most popular methods being a cell phone reminder or text message (29%) and a nominated day each week or month (26%). Discussions between the ECPs and the patients were more extensive for patients who were compliant with the MRRF.

Conclusions: ECPs recommended RFs more frequently with DD and 1M SH lenses than with 2W SH lenses, consistent with manufacturers' recommendations. Patients were less compliant with RF than ECPs for all lens types investigated. Patients were most compliant with RF when wearing DD lenses and least compliant when wearing 2W SH lenses. Better communication facilitated greater compliance with RF. More than half of those not replacing lenses, when recommended, reported that this was because they forgot which day to replace their lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To determine the types of contact lenses prescribed for infants (aged 0 to 5 years), children (6 to 12 years), and teenagers (13 to 17 years) around the world.

Methods. Up to 1000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year for 5 consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form.

Results. Data were received relating to 105,734 fits [137 infants, 1,672 children, 12,117 teenagers, and 91,808 adults (age ≥18 years)]. The proportion of minors (<18 year old) fitted varied considerably between nations, ranging from 25% in Iceland to 1% in China. Compared with other age groups, infants tend to be prescribed a higher proportion of rigid, soft toric, and extended wear lenses, predominantly as refits for full-time wear, and fewer daily disposable lenses. Children are fitted with the highest proportion of daily disposable lenses and have the highest rate of fits for part-time wear. Teenagers have a similar lens fitting profile to adults, with the main distinguishing characteristic being a higher proportion of new fits. Orthokeratology fits represented 28% of all contact lenses prescribed to minors.

Conclusions. Patterns of contact lens prescribing to infants and children are distinctly different to those of teenagers and adults in a number of respects. Clinicians can use the data presented here to compare their own patterns of contact lens prescribing to minors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To assess eye care practitioners (ECPs) recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses in Canada and the U.S. and to compare noncompliance (NC) with manufacturer recommended RF by the ECP and patient, and the reasons given for NC.

Methods. Invitations to participate were sent by e-mail to ECPs in Canada and the U.S. Twenty patient surveys were sent to 420 ECPs, and 2232 eligible surveys were received from 216 ECPs (26% Canada, 74% U.S.). Questions related to patient demographics, lens type, wearing patterns, ECP instructions for RF, and actual patient RF. ECPs provided lens information and their recommendation for RF after the surveys were completed and sealed in envelopes. Responses were anonymous.

Results. DD accounted for 18% (Canada) vs. 16% (U.S.) of wearers (p > 0.05); 35% (Canada) vs. 45% (U.S.) wore 2-week replacement SH (2WR; p = 0.011); and 47% (Canada) vs. 39% (U.S.) wore 1-month replacement SH (1MR) lenses (p = 0.025). Thirty-four percent (Canada) vs. 18% (U.S.) of ECPs recommended longer RFs than the manufacturer recommended RF for 2WR lens wearers (p < 0.001); 6% (Canada) vs. 4% (U.S.) for DD wearers; and 2% (Canada) vs. 1% (U.S.) for 1MR lens wearers. NC rates for actual RFs reported by patients were not different between countries (p > 0.05) and were lowest for DD (13% Canada, 12% U.S.), followed by 1MR (33% Canada, 28% U.S.). The highest NC rates were with 2WR (50% Canada, 52% U.S.). The most frequent reason for NC with 2WR and 1MR was “forgetting which day to replace lenses” (54% Canada, 53% U.S.) and in DD wearers “to save money” (56% Canada, 29% U.S., p < 0.001).

Conclusions. 1MR lenses are more frequently prescribed in Canada. ECPs in Canada were NC with 2WR lenses more frequently than U.S. ECPs, but patient NC rates were the same in both countries for all lens types. ECP and patient NC rates were highest for 2WR lens wearers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess current recommendations by optometrists for replacement frequency (RF) of silicone hydrogels (SH) and daily disposable (DD) contact lenses in Canada, determine rates of non-compliance with recommendations by both the optometrist and patient, and investigate reasons for non-compliance.

Methods: Survey packages were sent to optometrists in Canada who had agreed to participate. Patients completed survey questions regarding demographics and contact lens wearing patterns, including recommended and actual contact lens RF. Optometrists were asked to provide lens information and their recommendation for RF. Fifty-eight optometrists returned 654 surveys, of which 578 were eligible for analysis.

Results: Seventy percent of patients were female with a median age of 32 years. Lens type distribution was 18% DD, 35% two-week SH, and 47% one-month SH. Six percent were worn for extended wear. Daily wear median wearing time was 12 hours/day, a median of five days/week for DD, seven days/week for SH (two-week and one-month). Optometrists’ recommendations were non-compliant with the manufacturers’ recommended RF for 6% of DD, 35% of two week, and 2% of one-month patients. Patients were non-compliant with recommendations from both the manufacturer and optometrist for 12% of DD, 43% of two-week, and 31% of one-month lens wearers. The most common reason for non-compliance was forgetting which day to replace lenses. Fifty-six percent thought a reminder system would help with compliance. A higher proportion of compliant patients followed the RF because of confidence in their optometrist.

Conclusions: Optometrists generally recommended RFs consistent with manufacturers’ recommendations for DD and one-month SH lenses but often recommended longer intervals for two-week SH lenses. Patients were most compliant when wearing DD lenses and least compliant when wearing two-week SH lenses. Communication between the patient and optometrists concerning the risks of non-compliance, or initiating a reminder system might improve compliance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To characterize and discover the determinants of the frequency of wear (FOW) of contact lenses. Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for daily wear lens fits were analyzed. Data were collected in relation to 74,510 and 9,014 soft and rigid lens fits, respectively. Overall, FOW was 5.9±1.7 days per week (DPW). When considering the proportion of lenses worn between one to seven DPW, the distribution for rigid lenses is skewed toward full-time wear (7 DPW), whereas the distribution for soft daily disposable lenses is perhaps bimodal, with large and small peaks at seven and two DPW, respectively. There is a significant variation in FOW among nations (P<0.0001), ranging from 6.8±1.0 DPW in Greece to 5.1±2.5 DPW in Kuwait. For soft lenses, FOW increases with decreasing age. Females (6.0±1.6 DPW) wear lenses more frequently than males (5.8±1.7 DPW) (P=0.0002). FOW is greater among those wearing presbyopic corrections (6.1±1.4 DPW) compared with spherical (5.9±1.7 DPW) and toric (5.9±1.6 DPW) designs (P<0.0001). FOW with hydrogel peroxide systems (6.4±1.1 DPW) was greater than that with multipurpose systems (6.2±1.3 DPW) (P<0.0001).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 ± 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n = 8) or continuous wear (LCW; n = 8) basis; balafilcon-A contact lenses on a daily wear (BDW; n = 8) or continuous wear (BCW; n = 8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n = 8); and no lenses (controls; n = 8). OST was measured continuously five times, for 8 s after a blink, following a minimum of 2 h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 ± 1.7 °C versus 35.0 ± 1.1 °C; p < 0.005), predominantly in the LCW group (38.6 ± 1.0 °C; p < 0.0001). Lens surface temperature was highly correlated (r = 0.97) to, but lower than OST (by -0.62 ± 0.3 °C). There was no difference with modality of wear (DW 37.5 ± 1.6 °C versus CW 37.8 ± 1.9 °C; p = 0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 ± 1.1 °C versus 37.5 ± 1.5 °C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p = 0.07) or without (p = 0.47) lenses in situ. Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens. © 2004 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: A population based, cross-sectional telephone survey was conducted to estimate the total penetrance of contact lens wear in Australia. Methods: A total of 42,749 households around Australia were randomly selected from the national electronic telephone directory based on postcode distribution. Before contact was attempted, letters of introduction were sent. The number of individuals and contact lens wearers in each household was ascertained and lens wearers were interviewed to determine details of lens type and mode of wear using a structured questionnaire. Results: Of households contacted, 59.2% (19,171/32,405) agreed to participate. Response rates were only marginally higher amongst households that first received a letter of introduction. In these households, 35,914 individuals were identified, of which, 1,798 were contact lens wearers. The penetrance of contact lens wear during the study period was 5.01% (95% CI: 4.78-5.24). Soft hydrogel lenses had the largest penetrance in the community, (66.7% of all wearers), however, their market share decreased significantly over the study period with increased uptake of newly introduced lens types. Conclusions: The penetrance of contact lens wear concurs with market estimates and equates to approximately 680,000 contact lens wearers aged between 15 and 64 years in Australia. The low response rate obtained in this study highlights the difficulty in contemporary use of telephone survey methodology

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Rigid lenses have been fitted less since the introduction of soft lenses nearly 40 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 facilitate an accurate characterization of the pattern of the decline of rigid lens fitting during the first decade of this century. There is a trend for rigid lenses to be utilized primarily for refitting those patients who are already successful rigid lens wearers—most typically older females being refit with higher Dk materials. Rigid lenses are generally fitted on a full-time basis (four or more days of wear per week) without a planned replacement schedule. Orthokeratology is especially popular in the Netherlands, but is seldom prescribed in the other countries surveyed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study was designed to derive central and peripheral oxygen transmissibility (Dk/t) thresholds for soft contact lenses to avoid hypoxia-induced corneal swelling (increased corneal thickness) during open eye wear. Central and peripheral corneal thicknesses were measured in a masked and randomized fashion for the left eye of each of seven subjects before and after 3 h of afternoon wear of five conventional hydrogel and silicone hydrogel contact lens types offering a range of Dk/t from 2.4 units to 115.3 units. Curve fitting for plots of change in corneal thickness versus central and peripheral Dk/t found threshold values of 19.8 and 32.6 units to avoid corneal swelling during open eye contact lens wear for a typical wearer. Although some conventional hydrogel soft lenses are able to achieve this criterion for either central or peripheral lens areas (depending on lens power), in general, no conventional hydrogel soft lenses meet both the central and peripheral thresholds. Silicone hydrogel contact lenses typically meet both the central and peripheral thresholds and use of these lenses therefore avoids swelling in all regions of the cornea. ' 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 92B: 361–365, 2010