987 resultados para dental prosthesis


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The evolution of ceramic systems currently allows the manufacture of prosthesis similar to the natural teeth, meeting the expectations of patients. However, when using vitreous ceramic the color of substrate is significant for the esthetic result, requiring planning aesthetic cores when involved reconstruction of endodontically treated teeth without coronal structure. Thus, the aim of this study to describe a case report of aesthetic rehabilitation in upper anterior teeths using vitreous ceramic system for the reconstruction of elements: 11, 12, 21 and 22 after endodontically treated. It was emphasized the removal of crowns and manufacture of custom cast post and core with ceramic in coronal portion, prioritizing the aesthetic result. Through the clinical results observed can be seen that the use of custom cast post and core with ceramic in association lithium disilicate glass ceramics provided a satisfactory aesthetic result.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to review the literature in order to discuss the main and the most effective therapeutic activities to control the nocturnal bruxism. To identify the studies included in this review, it was conducted a detailed and advanced search strategy in the PubMed and Medline databases. It was used as KEY WORDS: bruxism, therapeutics and drug therapy. Inclusion criteria were: case reports, randomized controlled trials, in vitro studies, literature reviews and systematic reviews with or without meta-analysis of the past 10 years that addressed the theme. Exclusion criteria were: articles without abstract, animal studies, articles whose first language was not English and articles from journals that do not belong to the dentario field. From a total of 83 articles, after an analysis according to the inclusion and exclusion criteria, 33 articles were selected. Despite the fact that there is a small number of prospective clinical studies with high degree of reliability and most studies that evaluated the alternative treatments effectiveness are isolated case reports, the current literature shows that the use of botulinum toxin has been shown to be effective in the control of nocturnal bruxism. On the other hand, important aspects such as transitory effect, safe dosage and application technique are still little discussed, then, further studies are needed to have these doubts clarified.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osseointegrated implants have specific nature distinguish them from natural teeth making them more susceptible to the efforts generated by mastication. The absence of periodontal ligament, which absorbs the masticatory forces and allows the movement of the teeth interfere with the reception of occlusal loads and therefore the predictability of implants. In the boneimplant interface did not occur the phenomena of dissipation of impact, even the movement induced. Thus, during planning and installation of implant prosthesis, the type and characteristics of occlusal pattern adopted should be established with criteria to be no grounds for future failures. In this regard we highlight the occlusal overload generated by several reasons like the presence of premature contacts, interference during motion excursive, deleterious habits and inappropriate extensions on cantilevers. Thus, the objective is to provide a review of the literature regarding the importance of occlusion in oral rehabilitation with implants. Factors to be considered in establishing a favorable occlusion, consistent with prostheses on implants will be described

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In part I of this article, the factors related to the establishment of a favourable occlusion for the implant prosthodontics as well as its real importance in this kind of rehabilitation were showed up. However, it is known that the occlusal characteristics adopted in implant prosthodontics show specific patterns which must be different between each other in accordance to the type of prosthesis installed. The objective of the second part of this work is to present to the reader, by a literature review, those characteristics, justifying the reason because they must be associated to specific kind of prosthesis for favor the treatment established.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have identified impaired neutrophils in elderly individuals which could be involved with -related denture stomatitis (DS), an oral infection predominantly caused by , affecting especially elderly individuals using dental prosthesis. However, specific mechanisms performed by neutrophil contributing to the susceptibility of the elderly to DS are not fully understood. This study evaluated activation features of blood neutrophils from elderly and young individuals with DS. Blood neutrophils cultured with . from elderly subjects secreted decreased levels of CXCL8. However, . challenged-neutrophils from DS patients produced high IL-4 and IL-10, and low GM-CSF levels, regardless of age. Additional elastase activity of neutrophils from both elderly groups was detected after incubation with . , but only neutrophils from elderly DS demonstrated high myeloperoxidase activity. Therefore, DS patients have affected neutrophils, and the advance of age intensifies these damages. In sumamry, individuals with -related denture stomatitis presented variation in the neutrophil phenotype and activation. Such alterations were more intense in neutrophils from infected elderly individuals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Statement of problem. The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. Purpose. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. Material and methods. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Results. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. Conclusions. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342)