1000 resultados para correlation interferometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter proposes a simple tuning algorithm for digital deadbeat control based on error correlation. By injecting a square-wave reference input and calculating the correlation of the control error, a gain correction for deadbeat control is obtained. The proposed solution is simple, it requires a short tuning time, and it is suitable for different DC-DC converter topologies. Simulation and experimental results on synchronous buck converters confirm the properties of the proposed tuning algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we analyse simultaneous measurements (at 50 Hz) of velocity at several heights and shear stress at the surface made during the Utah field campaign for the presence of ranges of scales, where distinct scale-to-scale interactions between velocity and shear stress can be identified. We find that our results are similar to those obtained in a previous study [Venugopal et al., 2003] (contrary to the claim in V2003, that the scaling relations might be dependent on Reynolds number) where wind tunnel measurements of velocity and shear stress were analysed. We use a wavelet-based scale-to-scale cross-correlation to detect three ranges of scales of interaction between velocity and shear stress, namely, (a) inertial subrange, where the correlation is negligible; (b) energy production range, where the correlation follows a logarithmic law; and (c) for scales larger than the boundary layer height, the correlation reaches a plateau.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address a certain inverse problem in ultrasound-modulated optical tomography: the recovery of the amplitude of vibration of scatterers [p(r)] in the ultrasound focal volume in a diffusive object from boundary measurement of the modulation depth (M) of the amplitude autocorrelation of light [phi(r, tau)] traversing through it. Since M is dependent on the stiffness of the material, this is the precursor to elasticity imaging. The propagation of phi(r, tau) is described by a diffusion equation from which we have derived a nonlinear perturbation equation connecting p(r) and refractive index modulation [Delta n(r)] in the region of interest to M measured on the boundary. The nonlinear perturbation equation and its approximate linear counterpart are solved for the recovery of p(r). The numerical results reveal regions of different stiffness, proving that the present method recovers p(r) with reasonable quantitative accuracy and spatial resolution. (C) 2011 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with surface profilometry, where we try to detect a periodic structure, hidden in randomness using the matched filter method of analysing the intensity of light, scattered from the surface. From the direct problem of light scattering from a composite rough surface of the above type, we find that the detectability of the periodic structure can be hindered by the randomness, being dependent on the correlation function of the random part. In our earlier works, we had concentrated mainly on the Cauchy-type correlation function for the rough part. In the present work, we show that this technique can determine the periodic structure of different kinds of correlation functions of the roughness, including Cauchy, Gaussian etc. We study the detection by the matched filter method as the nature of the correlation function is varied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated the electronic structure of a double perovskite Ca2FeReO6 using photoemission spectroscopy and LDA+U bandstructure calculations. Small spectral weight at the Fermi level observed above the metal–insulator transition temperature, gradually disappears with decreasing T, forming a small (≤50 meV) energy gap. To reproduce this small energy gap, we require a very large effective U (Ueff) for Re (4 eV) in addition to Ueff of 4 eV for Fe. From simple calculations in terms of the ionic radii, we demonstrate that the Fe–Re bandwidth is smaller than that of Fe–Mo in Ca2FeMoO6, which should yield a strong electron correlation in the Re 5d bands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study reports a two dimensional NMR experiment which separates single quantum spectra of enantiomers from that of a racemic mixture. This is a blend of selective double quantum refocusing, for resolving couplings and chemical shift interactions along two dimensions followed by correlation of the selectively excited protons to the entire coupled spin network. The concept is solely based on the presence of distinct intra methyl dipolar couplings of different enantiomers when dissolved in chiral orienting media. The analysis of single enantiomer spectrum obtained from respective F-2 cross sections yield all the spectral information. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low strain shear modulus plays a fundamental role in earthquake geotechnical engineering to estimate the ground response parameters for seismic microzonation. A large number of site response studies are being carried out using the standard penetration test (SPT) data, considering the existing correlation between SPT N values and shear modulus. The purpose of this paper is to review the available empirical correlations between shear modulus and SPT N values and to generate a new correlation by combining the new data obtained by the author and the old available data. The review shows that only few authors have used measured density and shear wave velocity to estimate shear modulus, which were related to the SPT N values. Others have assumed a constant density for all the shear wave velocities to estimate the shear modulus. Many authors used the SPT N values of less than 1 and more than 100 to generate the correlation by extrapolation or assumption, but practically these N values have limited applications, as measuring of the SPT N values of less than 1 is not possible and more than 100 is not carried out. Most of the existing correlations were developed based on the studies carried out in Japan, where N values are measured with a hammer energy of 78%, which may not be directly applicable for other regions because of the variation in SPT hammer energy. A new correlation has been generated using the measured values in Japan and in India by eliminating the assumed and extrapolated data. This correlation has higher regression coefficient and lower standard error. Finally modification factors are suggested for other regions, where the hammer energy is different from 78%. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the results of an experimental and numerical study conducted on a closed-cell aluminium foam that was subjected to uniaxial compression with lateral constraint. X-ray computed tomography was utilized to gain access into the three-dimensional (3-D) structure of the foam and some aspects of the deformation mechanisms. A series of advanced 3-D image analyses are conducted on the 3-D images aimed at characterizing the strain localization regions. We identify the morphological/geometrical features that are responsible for the collapse of the cells and the strain localization. A novel mathematical approach based on a Minkowski tensor analysis along with the mean intercept length technique were utilized to search for signatures of anisotropy across the foam sample and its evolution as a function of loading. Our results show that regions with higher degrees of anisotropy in the undeformed foam have a tendency to initiate the onset of cell collapse. Furthermore, we show that strain hardening occurs predominantly in regions with large cells and high anisotropy. We combine the finite element method with the tomographic images to simulate the mechanical response of the foam. We predict further deformation in regions where the foam is already deformed. Crown Copyright (C) 2012 Published by Elsevier Ltd. on behalf of Acta Materialia Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim of the study: The quantification of incidentally found aortic valve calcification on computed tomography (CT) is not performed routinely, as data relating to the accuracy of aortic valve calcium for estimating the severity of aortic stenosis (AS) is neither consistent nor validated. As aortic valve calcium quantification by CT is confounded by wall and coronary ostial calcification, as well as motion artifact, the ex-vivo micro-computed tomography (micro-CT) of stenotic aortic valves allows a precise measurement of the amounts of calcium present. The study aim, using excised aortic valves from patients with confirmed AS, was to determine if the amount of calcium on micro-CT correlated with the severity of AS. Methods: Each of 35 aortic valves that had been excised from patients during surgical valve replacement were examined using micro-CT imaging. The amount of calcium present was determined by absolute and proportional values of calcium volume in the specimen. Subsequently, the correlation between calcium volume and preoperative mean aortic valve gradient (MAVG), peak transaortic velocity (V-max), and aortic valve area (AVA) on echocardiography, was evaluated. Results: The mean calcium volume across all valves was 603.2 +/- 398.5 mm(3), and the mean ratio of calcium volume to total valve volume was 0.36 +/- 0.16. The mean aortic valve gradient correlated positively with both calcium volume and ratio (r = 0.72, p <0.001). V-max also correlated positively with the calcium volume and ratio (r = 0.69 and 0.76 respectively; p <0.001). A logarithmic curvilinear model proved to be the best fit to the correlation. A calcium volume of 480 mm(3) showed sensitivity and specificity of 0.76 and 0.83, respectively, for a diagnosis of severe AS, while a calcium ratio of 0.37 yielded sensitivity and specificity of 0.82 and 0.94, respectively. Conclusion: A radiological estimation of calcium amount by volume, and its proportion to the total valve volume, were shown to serve as good predictive parameters for severe AS. An estimation of the calcium volume may serve as a complementary measure for determining the severity of AS when aortic valve calcification is identified on CT imaging. The Journal of Heart Valve Disease 2012;21:320-327