973 resultados para corner detector
Resumo:
The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.
Resumo:
A key feature of memory processes is to link different input signals by association and to preserve this coupling at the level of synaptic connections. Late-phase long-term potentiation (L-LTP), a form of synaptic plasticity thought to encode long-term memory, requires gene transcription and protein synthesis. In this study, we report that a recently cloned coactivator of cAMP-response element-binding protein (CREB), called transducer of regulated CREB activity 1 (TORC1), contributes to this process by sensing the coincidence of calcium and cAMP signals in neurons and by converting it into a transcriptional response that leads to the synthesis of factors required for enhanced synaptic transmission. We provide evidence that TORC1 is involved in L-LTP maintenance at the Schaffer collateral-CA1 synapses in the hippocampus.
Resumo:
Drosophila avoid food contaminated by pathogenic bacteria and fungi using an olfactory pathway that is exquisitely tuned to a single microbial odour.
Resumo:
The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 +/- 3.4, coronary sinus 34.2 +/- 4.1, sino-tubular junction 29.7 +/- 3.4 and mid ascending aorta 32.7 +/- 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 +/- 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 +/- 3.7, and between both coronary ostia 7.2 +/- 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 +/- 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 +/- 3.3, CV 13-43%. Mean aortic valve area was 582.0 +/- 131.9 mm(2). The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.
Resumo:
The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show a coefficient of variation ≤ 1% for detector chambers inside the beam (excluding beam gradients) for short- and long-term response of the MVCT detector. Larger variations were observed in beam gradients and an influence of the X-ray target where degradation was found. The results assume that an 'air scan' procedure is performed daily to recalibrate the detector with the imaging beam. On short term, the detector response stability is comparable to other devices. Long-term measure- ments during two 50-day periods show a good reproducibility.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.
Resumo:
CERNin tutkimuskeskuksen rakenteilla olevan hadronikiihdyttimen eräs tarkoitus on todistaa Higgsin bosonin olemassaolo. Higgsin bosonin löytyminen yhtenäistäisi nykyisen hiukkasfysiikan teorian ja antaisi selityksen sille kuinka hiukkaset saavat massansa. Kiihdyttimen CMS koeasema on tarkoitettu erityisesti myonien ilmaisuun. Tämä työ liittyy CMS koeaseman RPC-ilmaisintyypin linkkijärjestelmään, jonka tarkoituksena on käsitellä ilmaisimelta tulevia myonien aiheuttamia signaaleja ja lähettää tiedot tärkeäksi katsotuista törmäystapahtumista tallennettavaksi analysointia varten. Työssä on toteutettu linkkijärjestelmän ohjaus- ja linkkikorteille testiympäristö, jolla voidaan todeta järjestelmän eri osien keskinäinen yhteensopivuus ja toimivuus. Työn alkuosassa esitellään ilmaisimen linkkijärjestelmän eri osat ja niiden merkitykset. Työn loppuosassa käydään läpi eri testimenetelmiä ja analysoidaan niiden antamia tuloksia.
Resumo:
Euroopan hiukkastutkimuslaitoksen CERNin rakenteilla olevan LHC-hiukkaskiihdyttimen CMS-koeasema on tarkoitettu erityisesti myonin ilmaisuun. Tässä työssä on esitelty CMS-koeaseman RPC-ilmaisintyypin linkkijärjestelmä ja sen testaamiseen tarkoitetut laitteet sekä laitteiden testaamiseen tarvittavat ohjelmistot. Työssä on selvitetty ohjelmien toimivuus ja keskinäinen yhteensopivuus.
Resumo:
In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.