970 resultados para body measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The controversial effects promoted by cardiac resynchronization therapy (CRT) on the ventricular repolarization (VR) have motivated VR evaluation by body surface potential mapping (BSPM) in CRT patients. Methods: Fifty-two CRT patients, mean age 58.8 +/- 12.3 years, 31 male, LVEF 27.5 +/- 9.2, NYHA III-IV heart failure with QRS181.5 +/- 14.2 ms, underwent 87-lead BSPM in sinus rhythm (BASELINE) and biventricular pacing (BIV). Measurements of mean and corrected QT intervals and dispersion, mean and corrected T peak end intervals and their dispersion, and JT intervals characterized global and regional (RV, Intermediate, and LV regions) ventricular repolarization response. Results: Global QTm (P < 0.001) and QTcm (P < 0.05) were decreased in BIV; QTm was similar across regions in both modes (P = ns); QTcm values were lower in RV/LV than in Intermediate region in BASELINE and BIV (P < 0.001); only RV/Septum showed a significant difference (P < 0.01) in the BIV mode. QTD values both of BASELINE (P < 0.01) and BIV (P < 0.001) were greater in the Intermediate than in the LV region. CRT effect significantly reduced global/regional QTm and QTcm values. QTD was globally decreased in RV/LV (Intermediate: P = ns). BIV mode significantly reduced global T peak end mean and corrected intervals and their dispersion. JT values were not significant. Conclusions: Ventricular repolarization parameters QTm, QTcm, and QTD global/regional values, as assessed by BSPM, were reduced in patients under CRT with severe HF and LBBB. Greater recovery impairment in the Intermediate region was detected by the smaller variation of its dispersion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Recent studies have raised controversy regarding the association between cesarean section and later obesity in the offspring. The purpose of this study was to assess the association of cesarean section with increased body mass index (BMI) and obesity in school children from two Brazilian cities with distinct socioeconomic backgrounds. Methods Two birth cohorts respectively born in 1994 in Ribeirao Preto, a wealthy city in Southeast, and in 1997/98 in Sao Luis, a less wealthy city in Northeast of Brasil, were evaluated. After birth, 2,846 pairs of mothers-newborns were evaluated in Ribeirao Preto and 2,542 in Sao Luis. In 2004/05, 790 children aged 10/11 years were randomly reassessed in Ribeirao Preto and 673 at 7/9 years in Sao Luis. Information on type of delivery, maternal and child characteristics, socioeconomic position and anthropometric measurements were collected after birth and at school age. Obesity was defined as BMI ≥ 95th percentile at school age. Results Obesity rate was 13.0% in Ribeirao Preto and 2.1% in Sao Luis. Cesarean section was associated with obesity and remained significant after adjustment only in Ribeirao Preto [OR = 1.74 (95% CI: 1.04; 2.92)]. The association between cesarean section and BMI remained significant after adjustment for maternal schooling, maternal smoking during pregnancy, duration of breastfeeding, gender, birth weight and gestational age, type of school and, only in Sao Luis, pre-pregnancy maternal weight. In Ribeirao Preto children born by cesarean section had BMI 0.31 kg/m2 (95%CI: 0.11; 0.51) higher than those born by vaginal delivery. In Sao Luis BMI of children born by cesarean section was 0.28 kg/m2 higher (95%CI: 0.08; 0.49) than those born by vaginal delivery. Conclusion A positive association between cesarean section and increased BMI z-score was demonstrated in areas with different socioeconomic status in a middle-income country.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Charmless charged two-body B decays are sensitive probes of the CKM matrix, that parameterize CP violation in the Standard Model (SM), and have the potential to reveal the presence of New Physics. The framework of CP violation within the SM, the role of the CKM matrix, with its basic formalism, and the current experimental status are presented. The theoretical tools commonly used to deal with hadronic B decays and an overview of the phenomenology of charmless two-body B decays are outlined. LHCb is one of the four main experiments operating at the Large Hadron Collider (LHC), devoted to the measurement of CP violation and rare decays of charm and beauty hadrons. The LHCb detector is described, focusing on the technologies adopted for each sub-detector and summarizing their performances. The status-of-the-art of the LHCb measurements with charmless two-body B decays is then presented. Using the 37/pb of integrated luminosity collected at sqrt(s) = 7 TeV by LHCb during 2010, the direct CP asymmetries ACP(B0 -> Kpi) = −0.074 +/- 0.033 +/- 0.008 and ACP(Bs -> piK) = 0.15 +/- 0.19 +/- 0.02 are measured. Using 320/pb of integrated luminosity collected during 2011 these measurements are updated to ACP(B0 -> Kpi) = −0.088 +/- 0.011 +/- 0.008 and ACP(Bs -> piK) = 0.27 +/- 0.08 +/- 0.02. In addition, the branching ratios BR(B0 -> K+K-) = (0.13+0.06-0.05 +/- 0.07) x 10^-6 and BR(Bs -> pi+pi-) = (0.98+0.23-0.19 +/- 0.11) x 10^-6 are measured. Finally, using a sample of 370/pb of integrated luminosity collected during 2011, the relative branching ratios BR(B0 -> pi+pi-)/BR(B0 -> Kpi) = 0.262 +/- 0.009 +/- 0.017, (fs/fd)BR(Bs -> K+K-)/BR(B0 -> Kpi)=0.316 +/- 0.009 +/- 0.019, (fs/fd)BR(Bs -> piK)/BR(B0 -> Kpi) = 0.074 +/- 0.006 +/- 0.006 and BR(Lambda_b -> ppi)/BR(Lambda_b -> pK)=0.86 +/- 0.08 +/- 0.05 are determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assuming that the heat capacity of a body is negligible outside certain inclusions the heat equation degenerates to a parabolic-elliptic interface problem. In this work we aim to detect these interfaces from thermal measurements on the surface of the body. We deduce an equivalent variational formulation for the parabolic-elliptic problem and give a new proof of the unique solvability based on Lions’s projection lemma. For the case that the heat conductivity is higher inside the inclusions, we develop an adaptation of the factorization method to this time-dependent problem. In particular this shows that the locations of the interfaces are uniquely determined by boundary measurements. The method also yields to a numerical algorithm to recover the inclusions and thus the interfaces. We demonstrate how measurement data can be simulated numerically by a coupling of a finite element method with a boundary element method, and finally we present some numerical results for the inverse problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wearable inertial and magnetic measurements units (IMMU) are an important tool for underwater motion analysis because they are swimmer-centric, they require only simple measurement set-up and they provide the performance results very quickly. In order to estimate 3D joint kinematics during motion, protocols were developed to transpose the IMMU orientation estimation to a biomechanical model. The aim of the thesis was to validate a protocol originally propositioned to estimate the joint angles of the upper limbs during one-degree-of-freedom movements in dry settings and herein modified to perform 3D kinematics analysis of shoulders, elbows and wrists during swimming. Eight high-level swimmers were assessed in the laboratory by means of an IMMU while simulating the front crawl and breaststroke movements. A stereo-photogrammetric system (SPS) was used as reference. The joint angles (in degrees) of the shoulders (flexion-extension, abduction-adduction and internal-external rotation), the elbows (flexion-extension and pronation-supination), and the wrists (flexion-extension and radial-ulnar deviation) were estimated with the two systems and compared by means of root mean square errors (RMSE), relative RMSE, Pearson’s product-moment coefficient correlation (R) and coefficient of multiple correlation (CMC). Subsequently, the athletes were assessed during pool swimming trials through the IMMU. Considering both swim styles and all joint degrees of freedom modeled, the comparison between the IMMU and the SPS showed median values of RMSE lower than 8°, representing 10% of overall joint range of motion, high median values of CMC (0.97) and R (0.96). These findings suggest that the protocol accurately estimated the 3D orientation of the shoulders, elbows and wrists joint during swimming with accuracy adequate for the purposes of research. In conclusion, the proposed method to evaluate the 3D joint kinematics through IMMU was revealed to be a useful tool for both sport and clinical contexts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Obesity is a growing problem in industrial nations. Our aim was to examine how overweight patients coped with systemic inflammatory response syndrome (SIRS) after polytrauma. METHODS: A total of 651 patients were included in this retrospective study, with an ISS≥16 and age≥16 years. The sample was subdivided into three groups: body mass index (BMI; all in kg/m(2))<25, BMI 25-30 and BMI>30, or low, intermediate and high BMI. The SIRS score was measured over 31 days after admission together with measurements of C-reactive protein (CRP), interleukin-6 (IL-6) and procalcitonin (PCT). Data are given as the mean±SEM if not otherwise indicated. Kruskal-Wallis and χ(2) tests were used for statistical analysis and the significance level was set at p<.05. RESULTS: The maximum SIRS score was reached in the low BMI-group at 3.4±0.4, vs. 2.3±0.1 and 2.5±0.2 in the intermediate BMI-group and high BMI-group, respectively (p<.0001). However, the maximum SIRS score was reached earlier in the BMI 25-30 group at 1.8±0.2 days, vs. 3.4±0.4 and 2.5±0.2 days in the BMI<25 and BMI>30 groups, respectively (p<.0001). The incidence of sepsis was significantly higher in the low BMI group at 46.1%, vs. 0.2% and 0% in the BMI 25-30 and BMI>30 groups, respectively (p<.0001). No significant differences in the CRP, IL-6 or PCT levels were found between groups. CONCLUSIONS: A higher BMI seemed to be protective for these patients with polytrauma-associated inflammatory problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine.Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous vertebroplasty, comprising an injection of polymethylmethacrylate (PMMA) into vertebral bodies, is a practical procedure for the stabilization of osteoporotic compression fractures as well as other weakening lesions. Cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the material plays a key role in this context. In order to enhance the safety for the patient, a rheometer system was developed to measure the cement viscosity intraoperatively. For this development, it is of great importance to know the proper viscosity to start the procedure determined by experienced surgeons and the relation between the time period when different injection devices are used and the cement viscosity. The purpose of the study was to investigate the viscosity ranges for different injection systems during conventional vertebroplasty. Clinically observed viscosity values and related time periods showed high scattering. In order to get a better understanding of the clinical observations, cement viscosity during hardening at different ambient temperatures and by simulation of the body temperature was investigated in vitro. It could be concluded, that the direct viscosity assessment with a rheometer during vertebroplasty can help clinicians to define a lower threshold viscosity and thereby decrease the risk of leakage and make adjustments to their injection technique in real time. Secondly, the acceleration in hardening of PMMA-based cements at body temperature can be useful in minimizing leakages by addressing them with a short injection break.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whole-body vibration exposure of locomotive engineers and the vibration attenuation of seats in 22 U.S. locomotives (built between 1959 and 2000) was studied during normal revenue service and following international measurement guidelines. Triaxial vibration measurements (duration mean 155 min, range 84-383 min) on the seat and on the floor were compared. In addition to the basic vibration evaluation (aw rms), the vector sum (av), the maximum transient vibration value (MTVV/aw), the vibration dose value (VDV/(aw T1/4)), and the vibration seat effective transmissibility factor (SEAT) were calculated. The power spectral densities are also reported. The mean basic vibration level (aw rms) was for the fore-aft axis x = 0.18 m/sec2, the lateral axis y = 0.28 m/sec2, and the vertical axis z = 0.32 m/sec2. The mean vector sum was 0.59 m/sec2 (range 0.27 to 1.44). The crest factors were generally at or above 9 in the horizontal and vertical axis. The mean MTVV/aw was 5.3 (x), 5.1 (y), and 4.8 (z), and the VDV/(aw T1/4) values ranged from 1.32 to 2.3 (x-axis), 1.33 to 1.7 (y-axis), and 1.38 to 1.86 (z-axis), generally indicating high levels of shocks. The mean seat transmissibility factor (SEAT) was 1.4 (x) and 1.2 (y) and 1 (z), demonstrating a general ineffectiveness of any of the seat suspension systems. In conclusion, these data indicate that locomotive rides are characterized by relatively high shock content (acceleration peaks) of the vibration signal in all directions. Locomotive vertical and lateral vibrations are similar, which appears to be characteristic for rail vehicles compared with many road/off-road vehicles. Tested locomotive cab seats currently in use (new or old) appear inadequate to reduce potentially harmful vibration and shocks transmitted to the seated operator, and older seats particularly lack basic ergonomic features regarding adjustability and postural support.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Yearling steers were sorted into four groups based on hip height and fat cover at the start of the finishing period. Each group of sorted steers was fed diets containing 0.59 or 0.64 Mcal NEg per pound of diet. The value of each carcass was determined by use of the Oklahoma State University Boxed Beef Calculator. Sorting to increase hip height decreased the percentage of Choice carcasses and fat cover, increased ribeye area, and had no effect on carcass weight or yield grades 1 and 2. Sorting to decrease initial fat cover decreased carcass weight, carcass fat cover, and percentage of choice carcasses and increased the proportion of yield grades 1 and 2 carcasses. Concentration of energy in the finishing diet had no effect on carcass measurements. Increasing the percentage of yield grades 1 and 2 carcasses did not result in increased economic value of the carcasses when quality grades were lower and when there was a wide spread between Choice and Select carcasses, as occurred in 1996. With less spread between Choice and Select, as in 1997, sorting the cattle to increase yield grades 1 and 2 resulted in increased value, especially for close-trim boxed beef. The results of this study emphasize the importance of knowing how carcasses will grade before selecting a valuebased market for selling cattle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lameness represents a major welfare and production issue in the poultry industry with a recent survey estimating 27% of birds lame and 3% unable to walk by 40 d of age. A variety of factors may induce lameness and are typically grouped into 2 broad classes on the basis of being infectious or skeletal in nature with the latter accounting for the majority of cases. The current work sought to build upon a large body of literature assessing the anatomical properties of bone in lame birds. Our specific objectives sought to identify relationships between relevant anatomical properties of the tibia and metatarsus using digital quantification from radiographs of legs and a measure of walking difficulty. Resulting output was statistically analyzed to assess 1) observer reliability for consistency in placing the leg during the radiograph procedure and quantification of the various measures within a radiograph, 2) the relationship between the various measurements of anatomical bone properties and sex, bird mass, and gait score, and 3) the relationship between each measurement and leg symmetry. Our anatomical bone measures were found to be reliable (intra-rater and test-retest reliabilities < 0.75) within radiograph for all measures and 8 of the 10 measures across radiographs. Several measures of bone properties in the tibia correlated to difficulty walking as measured by gait score (P < 0.05), indicating greater angulations with increasing lameness. Of the measures that manifested a gait score × bird mass interaction, heavier birds appeared to exhibit less angulation with increasing difficulty walking with lighter birds the opposite. These interactions suggest possibilities for influencing effects of activity or feed intake on bone mineralization with the bone angulation observed. Our efforts agree with that of others and indicate that angulation of the tibia may be related to lameness, though subsequent efforts involving comprehensive measures of bird activity, growth rates, and internal bone structure will be needed if the validity of the measures are to be accepted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The finite element analysis is an accepted method to predict vertebral body compressive strength. This study compares measurements obtained from in vitro tests with the ones from two different simulation models: clinical quantitative computer tomography (QCT) based homogenized finite element (hFE) models and pre-clinical high-resolution peripheral QCT-based (HR-pQCT) hFE models. About 37 vertebral body sections were prepared by removing end-plates and posterior elements, scanned with QCT (390/450μm voxel size) as well as HR-pQCT (82μm voxel size), and tested in compression up to failure. Non-linear viscous damage hFE models were created from QCT/HT-pQCT images and compared to experimental results based on stiffness and ultimate load. As expected, the predictability of QCT/HR-pQCT-based hFE models for both apparent stiffness (r2=0.685/0.801r2=0.685/0.801) and strength (r2=0.774/0.924r2=0.774/0.924) increased if a better image resolution was used. An analysis of the damage distribution showed similar damage locations for all cases. In conclusion, HR-pQCT-based hFE models increased the predictability considerably and do not need any tuning of input parameters. In contrast, QCT-based hFE models usually need some tuning but are clinically the only possible choice at the moment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vitrectomy is a standard ophthalmic procedure to remove the vitreous body from the eye. The biomechanics of the vitreous affects its duration (by changing the removal rate) and the mechanical forces transmitted via the vitreous on the surrounding tissues during the procedure. Biomechanical characterization of the vitreous is essential for optimizing the design and control of instruments that operate within the vitreous for improved precision, safety, and efficacy. The measurements are carried out using a magnetic microprobe inserted into the vitreous, a method known as magnetic microrheology. The location of the probe is tracked by a microscope/camera while magnetic forces are exerted wirelessly by applied magnetic fields. In this work, in vitro artificial vitreous, ex vivo human vitreous and ex vivo porcine vitreous were characterized. In addition, in vivo rabbit measurements were performed using a suturelessly injected probe. Measurements indicate that viscoelasticity parameters of the ex vivo human vitreous are an order of magnitude different from those of the ex vivo porcine vitreous. The in vivo intra-operative measurements show typical viscoelastic behavior of the vitreous with a lower compliance than the ex vivo measurements. The results of the magnetic microrheology measurements were validated with those obtained by a standard atomic force microscopy (AFM) method and in vitro artificial vitreous. This method allows minimally-invasive characterization of localized mechanical properties of the vitreous in vitro, ex vivo, and in vivo. A better understanding of the characteristics of the vitreous can lead to improvements in treatments concerning vitreal manipulation such as vitrectomy.