986 resultados para bland-Altman method
Resumo:
The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory
Resumo:
The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool
Resumo:
Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)
Resumo:
FUNDAMENTO: A medida precisa da pressão arterial é fundamental para a investigação científica ou decisão clínica. Nesse sentido, é importante verificar valores fornecidos por equipamentos eletrônicos. OBJETIVO: Validar o monitor Omron HEM 742 de medida de pressão arterial em adolescentes, segundo os critérios sugeridos pela British Hypertension Society. MÉTODOS: Participaram do estudo 150 adolescentes com idades entre 10 e 16 anos. O monitor automático Omron HEM 742 foi conectado em Y com equipamento auscultatório de coluna de mercúrio, e realizaram-se três avaliações simultâneas, calculando-se as diferenças entre os dois equipamentos. Para verificar a relação entre ambos, utilizaram-se o coeficiente de correlação intraclasse e a plotagem de Bland-Altman (concordância). A especificidade e a sensibilidade do aparelho foram determinadas pela curva ROC. RESULTADOS: A comparação entre as medidas acusou uma diferença menor ou igual a 5 mmHg em 67,3% dos valores sistólicos e 69,3% dos valores diastólicos; uma diferença menor ou igual a 10 mmHg ocorreu em 87,3% e 90,6% dos valores sistólicos e diastólicos, respectivamente; e uma diferença menor ou igual a 15 mmHg em 96,6% dos valores sistólicos e 97,3% dos diastólicos. Esses resultados indicam grau A segundo o protocolo da British Hypertension Society. Observou-se ainda elevada concordância nos valores obtidos por meio do monitor automático, e verificou-se que esse equipamento é capaz de identificar a presença ou a ausência da pressão arterial elevada. CONCLUSÃO: O monitor Omron HEM 742 mostrou-se válido para medidas de pressão arterial em adolescentes, conforme os critérios sugeridos pela British Hypertension Society.
Resumo:
The aim of this study was to examine the agreement between the results of body fat (BF and BF%), fat-free mass (FFM) and FFM index (FFMI= FFM/height2) as estimated by skinfold anthropometry (ANT), bioelectrical impedance (BIA) and dual-energy X-ray absorptiometry (DXA) in two groups of men (> or = 50 y), one comprising healthy individuals (n=23) and the other, patients with chronic obstructive pulmonary disease (COPD) (n=24). Comparisons between body composition techniques were done by repeated measures ANOVA; the Bland & Altman procedure was used to analyse agreement. RESULTS AND CONCLUSIONS: 1) comparison between healthy and COPD groups showed significant differences between all studied variables; 2) in the healthy group, values for BF, BF%, FFM and FFMI were not significantly different when BIA or ANT was compared to DXA; however, in COPD, values for BF and BF% were significantly higher and for FFM and FFMI significantly lower when BIA was compared to DXA; in contrast, no differences were shown between values for these variables when ANT was compared with DXA; 3) Bland & Altman test, in both groups, showed no agreement between BIA and DXA and between ANT and DXA; it was also shown that body fat was overestimated and fat free mass underestimated by BIA in relation to DXA.
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
O presente estudo visou garantir condições favoráveis para a avaliação de discriminação de cores em crianças, por meio de uma adaptação no modo Trivector do teste de discriminação de cores de Mollon-Reffin. Como a tarefa original, de indicar a abertura do C de Landolt, se mostrou pouco intuitiva para crianças pequenas, o alvo foi mudado para uma área colorida aproximadamente quadrada e a resposta requerida passou a ser tocar no alvo. O modo de teste Trivector mede os limiares de discriminação de cor ao longo de três linhas de confusão características das três formas variantes de visão de cor humana: protan-, deutan- e tritan-. O Experimento I avaliou a concordância entre o teste original e a versão adaptada, com 29 sujeitos adultos com visão de cor normal. A comparação dos limiares obtidos com as duas versões, por meio do método de avaliação de concordância de Bland-Altman, mostrou boa concordância entre as versões. No Experimento II, o teste adaptado foi aplicado em 25 crianças de 2 a 7 anos, usando técnicas de treino operante para estabelecer e manter o desempenho dos sujeitos. Os limiares diminuíram progressivamente acompanhando o aumento na idade. Os limiares protan- e deutan- foram consistentemente menores que os limiares tritan-, um padrão que já havia sido observado com adultos no teste original. Os resultados demonstram que, feitas as adaptações necessárias, o teste é adequado para a avaliação da discriminação de cor em crianças pequenas e pode ser uma ferramenta útil para a identificação das variações da visão de cor durante o desenvolvimento, bem como para a aplicação em outras populações humanas e, inclusive, outros primatas. (CNPq, FINEP).
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective The aim of this study was to evaluate repair after endodontic surgery using two- and tridimensional imaging methods. Materials and methods Periapical radiographs and cone beam computed tomography (CBCT) were performed before the surgeries and after 48 h (baseline), 4 months, and 8 months. The area (square millimeters) of periapical lesions in CBCT and in radiographs was compared regarding the percentage of repair. In the CBCT, multiple areas were converted to volume. Repeated-measures analyses and paired t tests (α=0.05) were used to compare the methods. Correlation coefficients were calculated between the periods of evaluation within the CBCT volumetric analysis. Bland-Altman plots were used to compare the methods, based on the 95 % limits of agreement for the difference of the means. Results Baseline showed a larger lesion volume (192.54 mm3 ) than 4-month (79.79 mm3 ) and 8-month (47.51 mm3 ) periods. No differences were found in the percentage of repair in the first 4 months and after 8 months. The volumetric analysis showed a higher percentage of repair when the first and last 4 months were compared. No differences were found in the percentage of repair by area in the CBCTs. Repair of 73 % was obtained after 8 months. Similar results were observed by the Bland-Altman agreement analyses. Conclusions The percentage of repair varied after 8 months, when lower values were obtained by volumetric evaluation. Clinical relevance Considering the outcome at follow-up periods over 4 months, tridimensional evaluation by CBCT is more capable of determining the absence of periapical bone repair than conventional two-dimensional radiographs. Therefore, the use of CBCT would be suggested only for more complex cases with slower evolution of repair or for the association of factors that make prognosis difficult after surgery.
Resumo:
The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Cell-dyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510) and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson's correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semi-automated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The actual study goal is to test the Ellestad and Weltman protocol concordance in the prediction of VO2max in Futsal athletes. There was no significant difference between the two protocols, there was significant correlation between methods, but the Bland & Altman plotting shown very high amplitude in the Confident Interval at 95%.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.