854 resultados para balloon embolization
Resumo:
PURPOSE: To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS: Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS: IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS: The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.
Resumo:
We describe the successful selective coil embolization of an infected superior gluteal pseudoaneurysm secondary to methicillin-resistant Staphylococcus aureus (MRSA) in a 36-year old women. The patient presented with a long history of drug abuse and perisacral abscesses due to chronic sacroilitis. The chosen strategy provides a safe and successful management of infected false gluteal artery aneurysm.
Resumo:
Triple A syndrome is a rare autosomal recessive inherited disorder which is characterized by alacrima, adrenal insufficiency, and achalasia. We report on a 14-year old girl with dysphagia, regurgitation, and vomiting since 5 years. At the age of five years an Addison crisis was diagnosed and cortisone substitution was initiated. In addition, the patient had episodes of conjunctivitis. Severe esophagitis and candida infection were diagnosed by esophago-gastro-duodenoscopy and treated with omeprazole and fluconazole. The esophageal barium swallow was typical for achalasia. Medical treatment of achalasia with oral nifedipine resulted only in a partial and temporal improvement. But after seven balloon dilatations dysphagia and nocturnal coughing improved clearly and a remarkable gain of weight could be seen. Direct sequencing showed a homozygous nonsense mutation in exon 11 of the AAAS gene leading to truncation at position 342 of the 546 amino acid protein. CONCLUSION: Triple A syndrome has to be considered in patients with dysphagia. In our patient, the absence of tears since birth followed by adrenal insufficiency were early signs of the triple A syndrome. Balloon dilatation of the esophago-gastric junction is an effective treatment, which can avoid surgical interventions.
Resumo:
BACKGROUND AND PURPOSE: The purpose of the study was to compare efficacy and potential complications of 2 commercially available devices for mechanical thromboembolectomy. METHODS: Devices were tested in an established animal model allowing the use of routine angiography catheters and thrombectomy devices. Radio-opaque thrombi were used for visualization of thrombus-device interaction during angiography. The Merci Retrieval System and the Catch Thromboembolectomy System were assessed each in 10 vessel occlusions. For every occluded vessel up to 5 retrieval attempts were performed. RESULTS: Sufficient recanalization was achieved with the Merci Retriever in 90% of occlusions, and with the Catch device recanalization was achieved in 70% of occlusions. Recanalization at the first attempt occurred significantly more often with the Merci Retriever compared to the Catch device (OR, 21; 95% CI, 1.78-248.11). Consequently, significantly more attempts (P=0.02) had to be performed with the Catch device; therefore, time to recanalization was longer. Thrombus fragmentations during retrieval were caused more often by the Catch device compared to the Merci Retriever (OR, 15.6; 95% CI, 1.73-140.84), resulting in a higher distal embolization rate. During retrieval both devices lost thrombotic material at the tip of the guide catheter, which was then aspirated in most cases. CONCLUSIONS: Both distal devices are effective for thromboembolectomy. To avoid loss of thrombotic material and distal embolization, the use of large luminal balloon guide catheters and aspiration during retrieval seems to be mandatory. The design of the Merci Retriever appears to be more efficient during thrombus mobilization and retrieval with less fragmentation compared to the Catch Thromboembolectomy System.
Resumo:
BACKGROUND AND PURPOSE: Although mechanical thrombectomy (MT) has an encouragingly high recanalization rate in treating stroke, it is associated with severe complications of which the underlying factors have yet to be identified. Because MT is a mechanical approach, the mechanical properties of the thrombus might be crucial for its success. The present study assesses the effect of thrombus length on the in vivo effectiveness and complication rate of MT. MATERIALS AND METHODS: Angiography and embolization of 21 cranial vessels with radiopaque whole-blood thrombi 10, 20, and 40 mm in length (7 occlusions each) were performed in 7 swine. MT was carried out using a distal snarelike device (BCR Roadsaver) with proximal balloon occlusion. A total of 61 retrievals were attempted. RESULTS: In the group of 10-mm occlusions, 77.8% of the attempts achieved complete recanalisation. For longer occlusions, the success rates decreased significantly to 20% of attempts for 20-mm occlusions (odds ratio [OR], 14; 95% confidence interval [CI], 2.2-89.2) and 11.1% for 40-mm occlusions (OR, 28; 95% CI, 3.9-202.2; P < .005). The low success rates were largely due to complications associated with thrombus compaction during retrieval. Similarly, the rate of thromboembolic events increased from 0% in 10-mm occlusions to 14.8% in 40-mm occlusions. CONCLUSIONS: MT using a distal device proved to be a fast, effective, and safe procedure for recanalizing short (10-mm) occlusions in the animal model. However, occlusion length emerged as a crucial determinant for MT with a significant decrease in recanalization success per attempt and increased complication rates. These findings suggest limitations of MT in the clinical application.
Resumo:
INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.
Resumo:
This article provides an overview on the actual state of the interventional neuroradiological management of carotid cavernous fistulas depending on their anatomy and pathophysiology. The results are based on our experience gained during the treatment of patients with complex CCF during the last 15 years. Indications, procedures, and results of transarterial, transvenous and combined arteriovenous approaches for balloon occlusion, embolization, coiling and stenting of these lesions are discussed. Progress in this field is constant so that new technical advances are expected to improve the safety and to expand the indications for these procedures in the future.
Resumo:
PURPOSE: To evaluate the efficacy of superselective embolization therapy in the management of acute lower gastrointestinal (LGI) hemorrhage, including any bleeding distal to the ligament of Treitz. MATERIALS AND METHODS: Between June and August 2007, 20 patients with acute LGI bleeding underwent superselective transcatheter arterial embolization (TAE) at the authors' institution. The bleeding had different causes. All patients were treated with use of microcatheters. The following embolic agents were used: microcoils (n = 16), polyvinyl alcohol (PVA) particles (n = 2), and a combination of microcoils and PVA particles (n = 2). Outcome measures included technical success (complete cessation of bleeding as documented at completion angiography), clinical success (resolution of signs or symptoms of LGI bleeding within 30 days after TAE), and the rate of major and minor complications. RESULTS: The identified bleeding sources were as follows: jejunal branch, branch of middle colic artery, branch of ileocolic artery, ileal branch, branch of left colic artery, branch of sigmoid artery, branch of the superior rectal artery, and branch of the middle rectal artery. Technical success with effective control of active bleeding was achieved in all patients (100%). Clinical success attributed to TAE was documented in 18 of the 20 patients (90%). Major complications included death due to pulmonary embolism, heart infarction, and multiorgan failure in the 3rd week after TAE; a procedure-related colonic infarction occurred in one patient. A minor complication occurred in one patient who developed a groin hematoma. CONCLUSIONS: Superselective embolization may be used for effective, minimally invasive control of acute LGI bleeding.
Resumo:
BACKGROUND AND PURPOSE: The major goal of acute ischemic stroke treatment is fast and sufficient recanalization. Percutaneous transluminal balloon angioplasty (PTA) and/or placement of a stent might achieve both by compressing the thrombus at the occlusion site. This study assesses the feasibility, recanalization rate, and complications of the 2 techniques in an animal model. MATERIALS AND METHODS: Thirty cranial vessels of 7 swine were occluded by injection of radiopaque thrombi. Fifteen vessel occlusions were treated by PTA alone and 15, by placement of a stent and postdilation. Recanalization was documented immediately after treatment and after 1, 2, and 3 hours. Thromboembolic events and dissections were documented. RESULTS: PTA was significantly faster to perform (mean, 16.6 minutes versus 33.0 minutes for stent placement; P < .001), but the mean recanalization rate after 1 hour was significantly better after stent placement compared with PTA alone (67.5% versus 14.6%, P < .001). Due to the self-expanding force of the stent, vessel diameter further increased with time, whereas the recanalization result after PTA was prone to reocclusion. Besides thromboembolic events related to the passing maneuvers at the occlusion site, no thrombus fragmentation and embolization occurred during balloon inflation or stent deployment. Flow to side branches could also be restored at the occlusion site because it was possible to direct thrombus compression. CONCLUSIONS: Stent placement and postdilation proved to be much more efficient in terms of acute and short-term vessel recanalization compared with PTA alone.