964 resultados para affinity capillary electrophoresis


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since its inception in the 80's, capillary electrophoresis has matured into a well established technique for the separation and analysis of complex samples. One of its strongest aspects is the ability to handle materials from a diversity of chemical classes, ranging from few to millions of Daltons. This is only possible because several modes of electrophoresis can be performed in a single capillary format. In this work, relevant aspects of capillary zone electrophoresis in its three modes (free solution, micellar and gel), capillary isoelectric focusing and capillary isotachophoresis are discussed and many representative applications are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) encompasses a number of characteristics quite suitable for the simultaneous analysis of small ions such as high efficiency and resolving power, directly associated to its impressively high peak capacity, and short analysis time. In appropriate conditions, it is possible to perform the separation of approximately 36 anions in less than 3 minutes. In this work, the mechanisms by which anion analysis is performed was criteriously discussed, and a thorough review of the literature in the past 5 years, focusing mostly in applications of CE to anion analysis in real matrices, was presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A capillary electrophoresis system using laser induced fluorescence detection is described. A Raman system equipped with a microscope has been used to focus the laser beam on the capillary giving a lateral resolution of 1.5 mm. The fluorescence signal of the analyte (ZnPcTS - tetrasulfonated zinc-phthalocyanine) was collected by the microscope objectives and analysed by a monochromator with confocal characteristics equipped with a CCD detector. Electropherograms obtained with this system were compared to those obtained on a commercial instrument, showing that the described system presents a lower detection limit and better resolution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, the analysis of cations by capillary electrophoresis is reviewed from the theoretical and practical point of view. Separation mechanisms and detection modes are discussed and illustrated. A thorough compilation of the literature over the last ten years, regarding applications of the technique to the analysis of cations in real matrices, is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A review about the state-of-the-art of flow injection analysis (FIA) -- capillary electrophoresis (CE) systems is presented. The basic principles of flow injection and capillary electrophoresis are briefly revised. The main aspects of the FIA-CE hybridization, including advantages and shortcomings, are discussed. Some applications involving all different designs are also presented. This review covers the literature from 1997 up to 2000.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This review focuses the development of electrochemical detection systems coupled to capillary electrophoresis. Conductometric, amperometric, voltametric, and potentiometric modes of detection are reviewed. The positioning of the electrodes, interferences of high electric field, and the materials employed in the fabrication and modification of the electrodes are discussed. The advantages of the use of electrochemical detection with capillary electrophoresis, regarding to the sensitivity and selectivity, is exemplified with a large number of applications. Also, the use of electrochemical detection systems in microchip technology is addressed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The most important features of the CE-ICP hyphenation, as well as its advantages and drawbacks as a tool for speciation are discussed. The fundamental principles of capillary electrophoresis and inductively coupled plasma mass spectrometry are also presented. Some applications involving different designs proposed in the literature to couple CE and ICP system for elemental speciation are reviewed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article describes a novel approach to the separation of fatty acids ranging from 8 to 20 carbons using capillary electrophoresis with contactless conductivity detection. Complete separation of nine linear chain fatty acids (from C8:0 to C20:0) was achieved in 15 min under normal polarity operation. Limits of detection ranged from 35 to 319 µmol L-1 for C20:0 to C8:0, respectively. The optimized running electrolyte composition was 5.0 mmol L-1 phosphate buffer at pH 7, 4.0 mmol L-1 dimethyl-b-cyclodextrin, 2.0 mmol L-1 trimethyl-b-cyclodextrin, acetonitrile 50% (v/v), and methanol 20% (v/v). The applicability of the separation system was demonstrated by the analysis of coconut vegetable oil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A digital multimeter (~U$ 240.00 on the national market) connected to a microcomputer by a RS-232 serial interface is proposed for data acquisition in equipment with analog output. Data are measured at the rate of 2 points per second and stored in text files by the software that accompanies the device, running in a Windows environment. The performance of the multimeter was verified by monitoring the transient signals generated in flow injection systems associated with fluorimetric, spectrophotometric and flame photometric detection. In addition, the performance of the proposed device was similar to that attained by employing an interface card with a 12-bit analog-to-digital converter for acquisition of the signals generated by a capillary electrophoresis equipment with oscillometric detection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes the analytical methods for determination of total chlorogenic acid (CGA) and their individual isomers. Spectrofotometric methods are adequate for total CGA analysis in green coffee but they can provide inflated results for coffee products. High pressure liquid chromatography (HPLC) with gel permeation column and ultraviolet (UV) monitoring is adequate for the simultaneous analysis of total CGA, alkaloids and sugars in coffee products. HPLC-UV-reversed phase is a simple, rapid and precise method for the determination of the individual isomers of CGA. Gas chromatography (GC) also is applied to the analysis of the individual isomers but phenolic acids need to be derivatized before analysis. Both HPLC- and GC-mass spectrometry provide an unequivocal identification of the individual isomers. The capillary electrophoresis method is simple, rapid and adequate to the simultaneous analysis of polyphenols and xanthines. Advantages and limitations of each method are discussed throughout the text.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new construction of a capillary electrophoresis instrument with a universal conductivity detector (oscillometric detector) is described. The performance of the electrophoresis equipment was evaluated through the separation and detection of inorganic anions and cations in aqueous solutions. The results reproduced those found in the literature for the investigated probe ions, showing an efficient separation and good repeatability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work reports the analysis of inorganic and organic contaminants in alcohol fuel samples using capillary electrophoresis. Chloride and sulfate were analyzed in nitrate/ monochloroacetic acid at 10 mmol L-1 concentration each under indirect UV detection (210 nm). The analysis of aldehydes is based on the 216 nm detection of 3-methyl-2-benzothiazoline hydrazone adducts. The running buffer consisted of 20 mmol L-1 tetraborate , 40 mmol L-1 sodium dodecyl sufate and 12 mmol L-1 beta-ciclodextrin. Both methodologies were applied to real samples indicating inorganic ion concentrations from 0.15 to 6.64 mg kg-1 and aldehydes from 32.0 to 91.3 mg L-1.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.