950 resultados para accuracy of estimation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Respiration chambers are one of the primary sources of data on methane emissions from livestock. This paper describes the results from a coordinated set of chamber validation experiments which establishes the absolute accuracy of the methane emission rates measured by the chambers, and for the first time provides metrological traceability to international standards, assesses the impact of both analyser and chamber response times on measurement uncertainty and establishes direct comparability between measurements made across different facilities with a wide range of chamber designs. As a result of the validation exercise the estimated combined uncertainty associated with the overall capability across all facilities reduced from 25.7% (k = 2, 95% confidence) before the validation to 2.1% (k = 2, 95% confidence) when the validation results are applied to the facilities’ data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Met Office station data from 1980 to 2012 has been used to characterise the interannual variability of incident solar irradiance across the UK. The same data are used to evaluate four popular historical irradiance products to determine which are most suitable for use by the UK PV industry for site selection and system design. The study confirmed previous findings that interannual variability is typically 3–6% and weighted average probability of a particular percentage deviation from the mean at an average site in the UK was calculated. This weighted average showed that fewer than 2% of site-years could be expected to fall below 90% of the long-term site mean. The historical irradiance products were compared against Met Office station data from the input years of each product. This investigation has found that all products perform well. No products have a strong spatial trend. Meteonorm 7 is most conservative (MBE = −2.5%), CMSAF is most optimistic (MBE = +3.4%) and an average of all four products performs better than any one individual product (MBE = 0.3%)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Psychological problems should be identified in breast cancer patients proactively if doctors and nurses are to help them cope with the challenges imposed by their illness. Screening is one possible way to identify emotional problems proactively. Self-report questionnaires can be useful alternatives to carrying out psychiatric interviews during screening, because interviewing a large number of patients can be impractical due to limited resources. Two such measures are the Hospital Anxiety and Depression Scale (HADS) and the General Health Questionnaire-12 (GHQ-12). Method: The present study aimed to compare the performance of the GHQ-12, and the HADS Unitary Scale and its subscales to that of the Schedule for Affective Disorders and Schizophrenia (SADS) in identifying patients with affective disorders, including DSM major depression and generalized anxiety disorder. The sample consisted of 296 female breast cancer patients who underwent surgery for breast cancer a year previously. Results: A small number of patients (11%) were identified as having DSM major depression or generalized anxiety disorder based on SADS score. The findings indicate that the optimal thresholds in detecting generalized anxiety disorder and DSM major depression with the HADS anxiety and depression subscales were ≥ 8 and ≥ 7, with 93.3% and 77.3% sensitivity, respectively, and 77.9% and 87.1% specificity, respectively. They also had a 21% and 36% positive predictive value, respectively. Using the HADS Unitary Scale the optimal threshold for detecting affective disorders was ≥ 12, with 88.9% sensitivity, 80.7% specificity, and a 35% positive predictive value. In detecting affective disorders, the optimal threshold on the GHQ-12 was ≥ 2, with 77.8% sensitivity and 70.2% specificity. This scale also had a 24% positive predictive value. In detecting generalized anxiety disorder and DSM major depression, the optimal thresholds on the GHQ-12 were ≥ 2 and ≥ 4 with 73.3% and 77.3% sensitivity, respectively, and 67.5% and 82% specificity, respectively. The scale also had 12% and 29% positive predictive values, respectively. Conclusion: The HADS Unitary Scale and its subscales were effective in identifying affective disorders. They can be used as screening measures in breast cancer patients. The GHQ-12 was less accurate in detecting affective disorders than the HADS, but it can also be used as a screening instrument to detect affective disorders, generalized anxiety disorder, and DSM major depression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human Body Thermoregulation Models have been widely used in the field of human physiology or thermal comfort studies. However there are few studies on the evaluation method for these models. This paper summarises the existing evaluation methods and critically analyses the flaws. Based on that, a method for the evaluating the accuracy of the Human Body Thermoregulation models is proposed. The new evaluation method contributes to the development of Human Body Thermoregulation models and validates their accuracy both statistically and empirically. The accuracy of different models can be compared by the new method. Furthermore, the new method is not only suitable for the evaluation of Human Body Thermoregulation Models, but also can be theoretically applied to the evaluation of the accuracy of the population-based models in other research fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bloom filters are a data structure for storing data in a compressed form. They offer excellent space and time efficiency at the cost of some loss of accuracy (so-called lossy compression). This work presents a yes-no Bloom filter, which as a data structure consisting of two parts: the yes-filter which is a standard Bloom filter and the no-filter which is another Bloom filter whose purpose is to represent those objects that were recognised incorrectly by the yes-filter (that is, to recognise the false positives of the yes-filter). By querying the no-filter after an object has been recognised by the yes-filter, we get a chance of rejecting it, which improves the accuracy of data recognition in comparison with the standard Bloom filter of the same total length. A further increase in accuracy is possible if one chooses objects to include in the no-filter so that the no-filter recognises as many as possible false positives but no true positives, thus producing the most accurate yes-no Bloom filter among all yes-no Bloom filters. This paper studies how optimization techniques can be used to maximize the number of false positives recognised by the no-filter, with the constraint being that it should recognise no true positives. To achieve this aim, an Integer Linear Program (ILP) is proposed for the optimal selection of false positives. In practice the problem size is normally large leading to intractable optimal solution. Considering the similarity of the ILP with the Multidimensional Knapsack Problem, an Approximate Dynamic Programming (ADP) model is developed making use of a reduced ILP for the value function approximation. Numerical results show the ADP model works best comparing with a number of heuristics as well as the CPLEX built-in solver (B&B), and this is what can be recommended for use in yes-no Bloom filters. In a wider context of the study of lossy compression algorithms, our researchis an example showing how the arsenal of optimization methods can be applied to improving the accuracy of compressed data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the accuracy of two imaging methods in diagnosing apical periodontitis (AP) using histopathological findings as a gold standard. Methods: The periapex of 83 treated or untreated roots of dogs` teeth was examined using periapical radiography (PR), cone-beam computed tomography (CBCT) scans, and histology. Sensitivity, specificity, predictive values, and accuracy of PR and CBCT diagnosis were calculated. Results: PR detected AP in 71% of roots, a CBCT scan detected AP in 84%, and AP was histologically diagnosed in 93% (p = 0.001). Overall, sensitivity was 0.77 and 0.91 for PR and CBCT, respectively. Specificity was 1 for both. Negative predictive value was 0.25 and 0.46 for PR and CBCT, respectively. Positive predictive value was 1 for both. Diagnostic accuracy (true positives + true negatives) was 0.78 and 0.92 for PR and CBCT (p = 0.028), respectively. Conclusion: A CBCT scan was more sensitive in detecting AP compared with PR, which was more likely to miss AP when it was still present. (J Endod 2009;35:1009-1012)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nesse artigo, tem-se o interesse em avaliar diferentes estratégias de estimação de parâmetros para um modelo de regressão linear múltipla. Para a estimação dos parâmetros do modelo foram utilizados dados de um ensaio clínico em que o interesse foi verificar se o ensaio mecânico da propriedade de força máxima (EM-FM) está associada com a massa femoral, com o diâmetro femoral e com o grupo experimental de ratas ovariectomizadas da raça Rattus norvegicus albinus, variedade Wistar. Para a estimação dos parâmetros do modelo serão comparadas três metodologias: a metodologia clássica, baseada no método dos mínimos quadrados; a metodologia Bayesiana, baseada no teorema de Bayes; e o método Bootstrap, baseado em processos de reamostragem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Diagnosis of patellar tendinopathy is based primarily on clinical examination; however, it is commonplace to image the patellar tendon for diagnosis confirmation, with the imaging modalities of choice being magnetic resonance imaging (MRI) and ultrasonography (US). The comparative accuracy of these modalities has not been established.

Hypothesis: Magnetic resonance imaging and US have good (>80%) accuracy and show substantial agreement in confirming clinically diagnosed patellar tendinopathy.

Study Design: Cohort study (diagnosis); Level of evidence, 2.

Methods: Magnetic resonance imaging and US (gray scale [GS-US] and color Doppler [CD-US]) features of 30 participants with clinically diagnosed patellar tendinopathy and 33 activity-matched, asymptomatic participants were prospectively compared. Accuracy, sensitivity, specificity, positive and negative predictive values, and the likelihood of positive and negative test results were determined for each technique.

Results: The accuracy of MRI, GS-US, and CD-US was 70%, 83%, and 83%, respectively (P = .04; MRI vs GS-US). The likelihood of positive MRI, GS-US, and CD-US was 3.1, 4.8, and 11.6, respectively. The MRI and GS-US had equivalent specificity (82% vs 82%; P = 1.00); however, the sensitivity of GS-US was greater than MRI (87% vs 57%; P = .01). Sensitivity (70% vs 87%; P = .06) and specificity (94% vs 82%; P = .10) did not differ between CD-US and GS-US.

Conclusions: Ultrasonography was more accurate than MRI in confirming clinically diagnosed patellar tendinopathy. GS-US and CD-US may represent the best combination for confirming clinically diagnosed patellar tendinopathy because GS-US had the greatest sensitivity, while a positive CD-US test result indicated a strong likelihood an individual was symptomatic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on an exploratory study that examined whether journalists
undertake the vital role of checking the validity and accuracy of information
supplied to them in media releases. It also monitored how much information
journalists used from press releases in their published work. The study followed Gandy's information subsidy theory by surveying 10 local government media relations officers who regularly issued media releases via
electronic mail or facsimile to a sample of 14 rural/regional newspapers. The data analysed found that rural/regional journalists were not adequately verifying information supplied in media releases and using a significant amount of this information verbatim.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: ARGOS satellite telemetry is one of the most widely used methods to track the movements of free-ranging marine and terrestrial animals and is fundamental to studies of foraging ecology, migratory behavior and habitat-use. ARGOS location estimates do not include complete error estimations, and for many marine organisms, the most commonly acquired locations (Location Class 0, A, B, or Z) are provided with no declared error estimate.
Methodology/Principal Findings: We compared the accuracy of ARGOS locations to those obtained using Fastloc GPS from the same electronic tags on five species of pinnipeds: 9 California sea lions (Zalophus californianus), 4 Galapagos sea lions (Zalophus wollebaeki), 6 Cape fur seals (Arctocephalus pusillus pusillus), 3 Australian fur seals (A. p. doriferus) and 5 northern elephant seals (Mirounga angustirostris). These species encompass a range of marine habitats (highly pelagic vs coastal), diving behaviors (mean dive durations 2–21 min) and range of latitudes (equator to temperate). A total of 7,318 ARGOS positions and 27,046 GPS positions were collected. Of these, 1,105 ARGOS positions were obtained within five minutes of a GPS position and were used for comparison. The 68th percentile ARGOS location errors as measured in this study were LC-3
0.49 km, LC-2 1.01 km, LC-1 1.20 km, LC-0 4.18 km, LC-A 6.19 km, LC-B 10.28 km.
Conclusions/Significance: The ARGOS errors measured here are greater than those provided by ARGOS, but within the range of other studies. The error was non-normally distributed with each LC highly right-skewed. Locations of species that make short duration dives and spend extended periods on the surface (sea lions and fur seals) had less error than species like elephant seals that spend more time underwater and have shorter surface intervals. Supplemental data (S1) are provided allowing the creation of density distributions that can be used in a variety of filtering algorithms to improve the quality of ARGOS tracking data.