883 resultados para WII FIT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although cross-cultural leadership research has thrived in international business literature, little attention has been devoted to understanding the effectiveness of non-western theories beyond their original contexts. The purpose of this study is to examine the cross-cultural endorsement of paternalistic leadership, an emerging non-western leadership theory, using data from GLOBE project. Using multigroup confirmatory factor analyses we found measurement equivalence of a scale derived from GLOBE’s data, which enabled us to compare the endorsement of paternalistic leadership dimensions across 10 cultural clusters and 55 societies. Our study revealed that there are significant differences in the importance societies give to each dimension, suggesting that paternalism as leadership style is not universally nor homogeneously endorsed. Furthermore, results suggest that different patterns of endorsement of each of these dimensions give rise to idiosyncratic shades of paternalistic leadership across societies. Implications for theory and future research on international business are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels of unilateral angular misfit prostheses in the prosthesis/implant/retaining screw system and in the surrounding bone using finite element analysis. Four models of a two-dimensional finite element were constructed: group I (control), prosthesis that fit the implant; groups 2 to 4, prostheses with unilateral angular misfit of 50, 100, and 200 mu m, respectively. A load of 133 N was applied with a 30-degree angulation and off-axis at 2 mm from the long axis of the implant at the opposite direction of misfit on the models. Taking into account the increase of the angular misfit, the stress maps showed a gradual increase of prosthesis stress and uniform stress in the implant and trabecular bone. Concerning the displacement, an inclination of the system due to loading and misfit was observed. The decrease of the unilateral contact between prosthesis and implant leads to the displacement of the entire system, and distribution and magnitude alterations of the stress also occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies. PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy. MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment. RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit. CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. Methods: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (α= 5%). Results: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68μm to 14.83μm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18μm) similar to those of premachined components (14.3 μm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 μm to 14.6 μm; p<0.05). There were no significant changes after porcelain baking, in both groups. Conclusion: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)-100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parametric VaR (Value-at-Risk) is widely used due to its simplicity and easy calculation. However, the normality assumption, often used in the estimation of the parametric VaR, does not provide satisfactory estimates for risk exposure. Therefore, this study suggests a method for computing the parametric VaR based on goodness-of-fit tests using the empirical distribution function (EDF) for extreme returns, and compares the feasibility of this method for the banking sector in an emerging market and in a developed one. The paper also discusses possible theoretical contributions in related fields like enterprise risk management (ERM). © 2013 Elsevier Ltd.