864 resultados para Validação da medicação prescrita


Relevância:

20.00% 20.00%

Publicador:

Resumo:

That study had the aim to validate an instrument to evaluate the knowledge about the Urinary Catheterization (UC) in males. Cross-sectional, descriptive, quantitative and methodological study, accomplished in Universidade Federal do Rio Grande do Norte (UFRN), Universidade do Estado do Rio Grande do Norte (UERN) and a private university from Rio Grande do Norte. Sample of 27 judges selected from the inclusion criteria: registered nurses, discipline of semiology and/or semiotics teachers, with at least 1 year of experience in the disciplines, to work at UFRN, UERN or in private university and agree to participate voluntarily with the signing of the Consent Form. Study developed in three stages: a) elaboration of twos instruments based on the scientific literature, resulting in a structured observation script type checklist consisting of 36 items and a knowledge questionnaire with 12 questions; b) submission of instruments to judges from June to September 2012, which should evaluate each item in "adequate," "adequate with changes" and "inappropriate", and make an overall evaluation of each instrument based on 10 requirements; c) and validation with a verification of the agreement level among the judges, through the application of Kappa Index (K) and Content Validity Index (CVI). It was used the consensus level higher than 0.60 (good) for Kappa Index and higher than 0.70 for CVI. The research project had favorable opinion from the Ethics in Research/HUOL (CAAE n. 0002.0.294.000-10). After being coded and tabulated, the data were analyzed using descriptive statistics. Of the 27 judges who evaluated the instrument, 77.8% are female, with a mean age of 36.6 (± 9.0) years, 63.0% worked in UFRN, 74.1% had master degree and 63.0% worked exclusively on teaching. The experience time mean in teaching was 7.9 (± 8.0) years and in the disciplines of semiology and/or semiotics in nursing was 5.5 (± 6.7) years. In judgment of the checklist and knowledge questionnaire, no step/question was considered inappropriate, since all achieved level of agreement within the established values. All the checklist steps obtained good to excellent K (between 0.60 and 1.00). Of the 36 items, 25 had excellent K (0.75 ≤ K <1.00) and excellent total K (K = 0.83). Regarding the IVC, all steps reached levels above 0.70 (between 0.74 and 1.00) and CVI total was 0.90. All questionnaire questions evaluated separately (K from 0.60 to 0.93 and CVI from 0.74 to 0.96) and generally (K from 0.79 to 1.00 and CVI from 0.89 to 1.00) had evaluation levels of content validity within the established values. The instruments were reformulated based on the agreement levels between judges and international guidelines, dissertations and scientific articles. Both instruments proved to be valid regarding to their content, allowing a clear and objective evaluation of knowledge and skills about UC, both nursing students as well as other students and health professionals, since the use of valid measures seeking the reduction of the risk of the results distorted

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo teve como objetivo construir e validar conteúdo de instrumentos avaliativos sobre conhecimento e habilidade de enfermagem no procedimento de sondagem nasogástrica. Trata-se de um estudo metodológico realizado na Universidade Federal do Rio Grande do Norte (UFRN) e na Universidade do Estado do Rio Grande do Norte (UERN). A amostra foi composta por 23 juízes, selecionados a partir dos critérios de inclusão: serem enfermeiros, docentes nas disciplinas de Semiologia e/ou Semiotécnica de Enfermagem, ter no mínimo um ano de experiência nestas disciplinas e ser das instituições selecionadas para o estudo. A pesquisa se desenvolveu em três etapas: (A) construção de dois instrumentos com base na revisão da literatura que resultou em um roteiro de observação da habilidade estruturado composto por 28 itens e um questionário sobre o conhecimento com 12 questões; (B) submissão dos instrumentos aos juízes, no período de junho a setembro de 2012, os quais deveriam julgar cada item como adequado , adequado com alterações ou inadequado , além de fazer uma avaliação geral de cada instrumento baseada em 10 critérios adaptados do referencial metodológico de Pasquali; e (C) validação com a verificação do nível de concordância entre os juízes, por meio da aplicação do Índice de Validade de Conteúdo (IVC) e do Índice Kappa. Utilizou-se o nível de consenso maior que 0,75 para o IVC e maior que 0,61 (bom) para o Índice Kappa. Estudo aprovado pelo Comitê de Ética em Pesquisa do Hospital Universitário Onofre Lopes (CEP/HUOL), sob CAAE nº 0002.0.294.000-10. Após serem codificados e tabulados, os dados foram analisados por meio de estatística descritiva. Dos 23 juízes, 87% eram do sexo feminino, com média de idade de 36,5 anos, 73,9% atuavam na UFRN, 78,3% possuíam mestrado acadêmico e 69,6% atuavam exclusivamente na docência. A média de tempo de experiência na docência foi de 7,9 anos e nas disciplinas de Semiologia e/ou Semiotécnica de Enfermagem foi de 5,6 anos. No julgamento do roteiro de observação estruturado e do questionário sobre o conhecimento, nenhum item/questão considerou-se inadequado, uma vez que todos obtiveram nível de concordância dentro dos índices estabelecidos (IVC > a 0,75 e Kappa > 0,61). Em relação ao roteiro estruturado para avaliar habilidade, dos 28 itens presentes, 13 apresentaram índice de concordância perfeito (IVC=1,00; Kappa= 1,00) e outros 15 foram considerados adequados com alterações, principalmente no que diz respeito à sequência instrucional dos tópicos, clareza e vocabulário. No questionário sobre o conhecimento, dentre as 12 questões que o compunham, 03 apresentaram índice de concordância perfeito e as demais adequadas com alterações quanto aos critérios vocabulário, clareza, atualização e precisão. Em relação à avaliação geral dos instrumentos, o roteiro estruturado de habilidade obteve IVC de 0,95 e Kappa de 0,91 e o questionário do conhecimento, IVC de 0,97 e Kappa de 0,94. Os dois instrumentos mostraram-se válidos quanto ao seu conteúdo, e constituem ferramentas para fomentar a qualidade da assistência de enfermagem em relação ao conhecimento e à habilidade em sondagem nasogástrica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to identify and describe the factors related to Patient Safety in a medication system according to the nurses analysis in a teaching hospital from the photographic analysis method. This was a cross-sectional, descriptive study with mixed approach in a teaching hospital in Rio Grande do Norte. The population consisted of 42 nurses from inpatient units, of which 34 composed the study sample. As eligibility criteria, we defined nurses from public service and nurses who agreed to participate. Ethical determinations were observed, the study was submitted to the Ethics and Research of the University Hospital Onofre Lopes, obtaining the assent with ethical assessment certificate (CAAE 0098.0.051.294-11). For data collection, we used the photographic method (Photographic Analysis Technique) by Patricia Marck (Canada). It was developed in two phases: at first, we randomly captured photos from the medication system, resulting in 282 images; then we selected/processed the photographs, which were reduced to 10 images in Microsoft Excel 2010; in the second phase, the nurses answered the questionnaire divided into socio-professional profile and Digital Photography Scoring Tool (questions a and b ). For analysis of the question a , we used the content analysis technique, and for b , we used the Statistical Package for the Social Sciences 20.0 (temporary license). The socio-professional profile revealed the predominance of females; age group 34-43 years; professionals with specialization; 10-18 years of length of service; and nurses working exclusively in the hospital and who know the Patient Safety. The photographic analysis in relation to Patient Safety resulted in specific categories for each stage of the medication system. Regarding disposal, we identified Proper verification ; Improper verification ; Correct identification ; Disposal in single doses ; and Improper Environment , with predominance of that last category. As for storage: Proper storage ; Improper storage ; Risk of exchange/disappearance ; and Poor hygiene , with special reference to improper storage. In preparation: Risk of exchanging medication/patient ; Inappropriate physical space ; and Inadequate 9 preparation of controlled drugs , highlighting the first category. In drug administration: Lack of Personal Protective Equipment ; Use of Personal Protective Equipment ; Improper administration technique ; Proper administration technique ; Correct drug identification ; Incorrect drug identification ; and Peripheral venous access without identification . From the safety assessment of 10 photographs, by adapting the scores (1-10) to the Likert Scale, we identified three Totally Unsafe (Level 1), three Unsafe (Level 2), three Partially Safe (Level 3), one Safe (Level 4), and no photograph considered Totally Safe. This study identified the prevalence of unsafety in the medication system in the nurses opinion. We were also able to understand that, although nurses identify safety aspects, the most prevalent categories characterize an unsafe assessment. Nursing needs to reflect on its practice, identifying gaps in the medication system in order to achieve a proper and safe care

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visando estabelecer normas para o DRIS na cultura do algodão, um produto agrícola em franca expansão no território nacional e com significativa contribuição econômica no PIB brasileiro, o presente trabalho estudou lavouras comerciais de municípios do Norte do Estado de Mato Grosso do Sul e Centro-Sul do Estado de Mato Grosso. Os resultados indicaram que a escolha da relação modifica a interpretação dos resultados, exceto quando é utilizada a metodologia proposta por Elwali e Gascho, pois, neste caso, os índices nutricionais convergem independentemente do método de escolha das relações. O método DRIS otimiza o gerenciamento das informações nutricionais do algodoeiro, e é possível detectar os nutrientes limitantes nas lavouras desta cultura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due of industrial informatics several attempts have been done to develop notations and semantics, which are used for classifying and describing different kind of system behavior, particularly in the modeling phase. Such attempts provide the infrastructure to resolve some real problems of engineering and construct practical systems that aim at, mainly, to increase the productivity, quality, and security of the process. Despite the many studies that have attempted to develop friendly methods for industrial controller programming, they are still programmed by conventional trial-and-error methods and, in practice, there is little written documentation on these systems. The ideal solution would be to use a computational environment that allows industrial engineers to implement the system using high-level language and that follows international standards. Accordingly, this work proposes a methodology for plant and control modelling of the discrete event systems that include sequential, parallel and timed operations, using a formalism based on Statecharts, denominated Basic Statechart (BSC). The methodology also permits automatic procedures to validate and implement these systems. To validate our methodology, we presented two case studies with typical examples of the manufacturing sector. The first example shows a sequential control for a tagged machine, which is used to illustrated dependences between the devices of the plant. In the second example, we discuss more than one strategy for controlling a manufacturing cell. The model with no control has 72 states (distinct configurations) and, the model with sequential control generated 20 different states, but they only act in 8 distinct configurations. The model with parallel control generated 210 different states, but these 210 configurations act only in 26 distinct configurations, therefore, one strategy control less restrictive than previous. Lastly, we presented one example for highlight the modular characteristic of our methodology, which it is very important to maintenance of applications. In this example, the sensors for identifying pieces in the plant were removed. So, changes in the control model are needed to transmit the information of the input buffer sensor to the others positions of the cell

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a set of intelligent algorithms with the purpose of correcting calibration errors in sensors and reducting the periodicity of their calibrations. Such algorithms were designed using Artificial Neural Networks due to its great capacity of learning, adaptation and function approximation. Two approaches willbe shown, the firstone uses Multilayer Perceptron Networks to approximate the many shapes of the calibration curve of a sensor which discalibrates in different time points. This approach requires the knowledge of the sensor s functioning time, but this information is not always available. To overcome this need, another approach using Recurrent Neural Networks was proposed. The Recurrent Neural Networks have a great capacity of learning the dynamics of a system to which it was trained, so they can learn the dynamics of a sensor s discalibration. Knowingthe sensor s functioning time or its discalibration dynamics, it is possible to determine how much a sensor is discalibrated and correct its measured value, providing then, a more exact measurement. The algorithms proposed in this work can be implemented in a Foundation Fieldbus industrial network environment, which has a good capacity of device programming through its function blocks, making it possible to have them applied to the measurement process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global Positioning System, or simply GPS, it is a radionavigation system developed by United States for military applications, but it becames very useful for civilian using. In the last decades Brazil has developed sounding rockets and today many projects to build micro and nanosatellites has appeared. This kind of vehicles named spacecrafts or high dynamic vehicles, can use GPS for its autonome location and trajectories controls. Despite of a huge number of GPS receivers available for civilian applications, they cannot used in high dynamic vehicles due environmental issues (vibrations, temperatures, etc.) or imposed dynamic working limits. Only a few nations have the technology to build GPS receivers for spacecrafts or high dynamic vehicles is available and they imposes rules who difficult the access to this receivers. This project intends to build a GPS receiver, to install them in a payload of a sounding rocket and data collecting to verify its correct operation when at the flight conditions. The inner software to this receiver was available in source code and it was tested in a software development platform named GPS Architect. Many organizations cooperated to support this project: AEB, UFRN, IAE, INPE e CLBI. After many phases: defining working conditions, choice and searching electronic, the making of the printed boards, assembling and assembling tests; the receiver was installed in a VS30 sounding rocket launched at Centro de Lançamento da Barreira do Inferno in Natal/RN. Despite of the fact the locations data from the receiver were collected only the first 70 seconds of flight, this data confirms the correct operation of the receiver by the comparison between its positioning data and the the trajectory data from CLBI s tracking radar named ADOUR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the transition from industrial society to information society, we realize that the digital training that is addressed is currently insufficient to navigate within a digitized reality. As proposed to minimize this problem, this paper assesses, validates and develops the software RoboEduc to work with educational robotics with the main differential programming of robotic devices in levels, considering the specifics of reality training . One of the emphases of this work isthe presentation of materials and procedures involving the development, analysis and evolution of this software. For validation of usability tests were performed, based on analysis of these tests was developed version 4.0 of RoboEduc

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improving the adherence between oilwell metallic casing and cement sheath potentially decrease the number of corrective actions present/y necessary for Northeastern wells submitted to steam injection. In addition to the direct costs involved in the corrective operations, the economic impact of the failure of the primary cementing aIso includes the loss in the production of the well. The adherence between casing and cement is current/y evaluated by a simple shear tests non standardized by the American Petroleum Institute (API). Therefore, the objective of the present is to propose and evaluate a standardized method to assess the adherence of oilwell metallic casing to cement sheath. To that end, a section of a cemented oilwell was simulated and used to test the effect of different parameters on the shear stress of the system. Surface roughness and different cement compositions submitted or not to thermal cycling were evaluated. The results revealed that the test geometry and parameters proposed yielded different values for the shear stress of the system, corresponding to different adherent conditions between metallic casing and cement sheath

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical activity is one of the main components of a healthy lifestyle, responsible for many health benefits. Despite being considered important for both disease prevention and health promotion there is high prevalence of sedentary behavior in the elderly population. Questionnaires are practical and feasible instruments for assessing levels of physical activity. However, they may have limitations in older age ranges. Accelerometers, movement sensors that make physical activity data more objective, emerge as reliable measuring devices. Aim: Determine the validity of the International Physical Activity Questionnaire (IPAQ) adapted for elderly with accelerometry in elderly women. Methods: 57 elderly women, with mean age of 66.05 ± 5.98 years who took part in hypertension control and physical activity incentive programs were assessed in relation to objective and subjective measures of physical activity. The accelerometer was used for 07 consecutive days, 24 hours per day before the IPAQ was applied. Data were analyzed using measures of central tendency and dispersion to characterize the sample according to variables collected. To check the validity of the data we used the Spearman correlation test, considering a significance level of p <0.05. Results: With respect to the categories of physical activity obtained by IPAQ, 46.4% developed moderate physical activity, followed by a high (30.3%) and low level (23.2%). There was a negative correlation only between self-reported time spent sitting and time spent on light activities as measured by accelerometry (r = - 0.408; p = 0.003) and mean activity level (counts/min) with physical activity levels evaluated by IPAQ (r = 0.297; p = 0.036). Conclusion: The IPAQ used in elderly women shows moderate to low validity levels according to accelerometry measures. Assessment of sedentary activities exhibited acceptable levels compared to accelerometry; however, moderate (r = 0.096; p > 0.05) to vigorous (r = 0.098; p > 0.05) activities were not correlated, demonstrating the inability of IPAQ to evaluate this type of activity in elderly women

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esse estudo se propôs a avaliar um método auxiliar de diagnóstico (DIAGNOdent®) na predição de cárie de dentina em dentes decíduos, através de validação histológica e de microdureza. Verificando possíveis diferenças entre os valores obtidos através do método auxiliar, além de determinar um ponto de corte para parada de remoção de tecido cariado. A amostra do estudo foi de 15 crianças que apresentaram 21 cavidades de cárie, tratadas e analisadas desde antes da realização da restauração até quando da exodontia do elemento dentário. Os espécimes foram analisados através do DIAGNOdent® antes da abertura das cavidades, após a remoção do tecido cariado e depois da reabertura das cavidades que se deu após a exodontia dos elementos dentários. Posteriormente, receberam preparo metalográfico para realização de testes de microdureza e microscopia óptica que serviram como forma de validação para as mensurações obtidas pela fluorescência a laser. Houve diferença significativa entre os valores DIAGNOdent® encontrados antes da abertura da cavidade e os demais (p < 0,0001). Havendo correlação significativa (r = 0,432 ; p = 0,019) apenas para as aferições obtidas antes da abertura das cavidades e quando do término da remoção do tecido cariado. Para a microdureza, as médias axiais foram significativamente maiores que as pulpares, existindo correlação entre a microdureza pulpar e os valores do DIAGNOdent® após a reabertura (r = - 0,472 ; p = 0,002). Valores de 15,38% para a sensibilidade, 100% para a especificidade, 100% para o valor preditivo positivo e 71,79% para o valor preditivo negativo, foram obtidos quando se utilizou um ponto de corte de 30 para fluorescência a laser, tendo como padrão-ouro a microdureza pulpar. Partindo da média dos valores de fluorescência a laser obtidos após a remoção do tecido cariado e acrescentando-se um desvio-padrão a esta, o método indicou o valor de 19 como ponto de corte para cessar a remoção de dentina. Concluiu-se que, nas condições analisadas, o método auxiliar de diagnóstico (DIAGNOdent®) é um método acurado na predição de cárie de dentina em dentes decíduos. Além disso, o método comprovou que o padrão usual de remoção de dentina garante a remoção do tecido cariado