984 resultados para VISUAL CONDITIONS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The frontal eye field (FEF) is known to be involved in saccade generation and visual attention control. Studies applying covert attentional orienting paradigms have shown that the right FEF is involved in attentional shifts to both the left and the right hemifield. In the current study, we aimed at examining the effects of inhibitory continuous theta burst (cTBS) transcranial magnetic stimulation over the right FEF on overt attentional orienting, as measured by a free visual exploration paradigm. In forty-two healthy subjects, free visual exploration of naturalistic pictures was tested in three conditions: (1) after cTBS over the right FEF; (2) after cTBS over a control site (vertex); and, (3) without any stimulation. The results showed that cTBS over the right FEF-but not cTBS over the vertex-triggered significant changes in the spatial distribution of the cumulative fixation duration. Compared to the group without stimulation and the group with cTBS over the vertex, cTBS over the right FEF decreased cumulative fixation duration in the left and in the right peripheral regions, and increased cumulative fixation duration in the central region. The present study supports the view that the right FEF is involved in the bilateral control of not only covert, but also of overt, peripheral visual attention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Central and peripheral vision is needed for object detection. Previous research has shown that visual target detection is affected by age. In addition, light conditions also influence visual exploration. The aim of the study was to investigate the effects of age and different light conditions on visual exploration behavior and on driving performance during simulated driving. METHODS: A fixed-base simulator with 180 degree field of view was used to simulate a motorway route under daylight and night conditions to test 29 young subjects (25-40 years) and 27 older subjects (65-78 years). Drivers' eye fixations were analyzed and assigned to regions of interests (ROI) such as street, road signs, car ahead, environment, rear view mirror, side mirror left, side mirror right, incoming car, parked car, road repair. In addition, lane-keeping and driving speed were analyzed as a measure of driving performance. RESULTS: Older drivers had longer fixations on the task relevant ROI, but had a lower frequency of checking mirrors when compared to younger drivers. In both age groups, night driving led to a less fixations on the mirror. At the performance level, older drivers showed more variation in driving speed and lane-keeping behavior, which was especially prominent at night. In younger drivers, night driving had no impact on driving speed or lane-keeping behavior. CONCLUSIONS: Older drivers' visual exploration behavior are more fixed on the task relevant ROI, especially at night, when driving performance becomes more heterogeneous than in younger drivers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Performance on interval timing is often explained by the assumption of an internal clock based on neural counting. According to this account, a neural pacemaker generates pulses, and the number of pulses relating to a physical time interval is recorded by a counter. Thus, the number of accumulated pulses is the internal representation of this interval. Several studies demonstrated that large visual stimuli are perceived to last longer than smaller ones presented for the same duration. The present study was designed to investigate whether nontemporal visual stimulus size directly affects the internal clock. For this purpose, a temporal reproduction task was applied. Sixty participants were randomly assigned to one of two experimental conditions with stimulus size being experimentally varied within either the target or the reproduction interval. A direct effect of nontemporal stimulus size on the pacemaker-counter system should become evident irrespective of whether stimulus size was experimentally varied within the target or the reproduction interval. An effect of nontemporal stimulus size on reproduced duration only occurred when stimulus size was varied during the target interval. This finding clearly argues against the notion that nontemporal visual stimulus size directly affects the internal clock. Furthermore, our findings ruled out a decisional bias as a possible cause of the observed differential effect of stimulus size on reproduced duration. Rather the effect of stimulus size appeared to originate from the memory stage of temporal information processing at which the timing signal from the pacemaker-counter component is encoded in reference memory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We tested the predictions of Attentional Control Theory (ACT) by examining how anxiety affects visual search strategies, performance efficiency, and performance effectiveness using a dynamic, temporal-constrained anticipation task. Higher and lower skilled players viewed soccer situations under 2 task constraints (near vs. far situation) and were tested under high (HA) and low (LA) anxiety conditions. Response accuracy (effectiveness) and response time, perceived mental effort, and eye-movements (all efficiency) were recorded. A significant increase in anxiety was evidenced by higher state anxiety ratings on the MRF-L scale. Increased anxiety led to decreased performance efficiency because response times and mental effort increased for both skill groups whereas response accuracy did not differ. Anxiety influenced search strategies, with higher skilled players showing a decrease in number of fixation locations for far situations under HA compared with LA condition when compared with lower skilled players. Findings provide support for ACT with anxiety impairing processing efficiency and, potentially, top-down attentional control across different task constraints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visual neglect is considerably exacerbated by increases in visual attentional load. These detrimental effects of attentional load are hypothesised to be dependent on an interplay between dysfunctional inter-hemispheric inhibitory dynamics and load-related modulation of activity in cortical areas such as the posterior parietal cortex (PPC). Continuous Theta Burst Stimulation (cTBS) over the contralesional PPC reduces neglect severity. It is unknown, however, whether such positive effects also operate in the presence of the detrimental effects of heightened attentional load. Here, we examined the effects of cTBS on neglect severity in overt visual search (i.e., with eye movements), as a function of high and low visual attentional load conditions. Performance was assessed on the basis of target detection rates and eye movements, in a computerised visual search task and in two paper-pencil tasks. cTBS significantly ameliorated target detection performance, independently of attentional load. These ameliorative effects were significantly larger in the high than the low load condition, thereby equating target detection across both conditions. Eye movement analyses revealed that the improvements were mediated by a redeployment of visual fixations to the contralesional visual field. These findings represent a substantive advance, because cTBS led to an unprecedented amelioration of overt search efficiency that was independent of visual attentional load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aims of the present study in Swiss dental practices were 1) to provide an update on the prevalence of different magnification devices, 2) to examine the relationship between self-assessed and objectively measured visual acuity, and 3) to evaluate the visual performance of dentists in the individually optimized clinical situation of their respective practices. METHODS AND MATERIALS Sixty-nine dentists from 40 randomly selected private practices (n=20, <40 years; n=49, ≥40 years) participated in the study. A questionnaire was provided to evaluate the self-assessed near visual acuity and the experience with magnification devices. The objective near visual acuity was measured under standardized conditions on a negatoscope. The clinical situation, including the use of habitual optical aids, was evaluated with visual tests on a phantom head. RESULTS A total of 64% of the dentists owned a dental loupe: 45% Galilean loupes, 16% Keplerian loupes, and 3% single lens loupes. In total, 19% of the questioned dentists owned a microscope in addition to the loupes. The correlation between the self-assessed and the objective visual performance of the dentists was weak (Spearman rank correlation coefficient=0.25). In the habitual clinical situation, magnification devices (p=0.03) and the dentist's age (p=0.0012) had a significant influence on the visual performance. CONCLUSIONS Many dentists were not aware of their visual handicaps. Optical aids such as loupes or microscopes should be used early enough to compensate for individual or age-related visual deficiencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La iluminación con diodos emisores de luz (LED) está reemplazando cada vez en mayor medida a las fuentes de luz tradicionales. La iluminación LED ofrece ventajas en eficiencia, consumo de energía, diseño, tamaño y calidad de la luz. Durante más de 50 años, los investigadores han estado trabajando en mejoras LED. Su principal relevancia para la iluminación está aumentando rápidamente. Esta tesis se centra en un campo de aplicación importante, como son los focos. Se utilizan para enfocar la luz en áreas definidas, en objetos sobresalientes en condiciones profesionales. Esta iluminación de alto rendimiento requiere una calidad de luz definida, que incluya temperaturas ajustables de color correlacionadas (CCT), de alto índice de reproducción cromática (CRI), altas eficiencias, y colores vivos y brillantes. En el paquete LED varios chips de diferentes colores (rojo, azul, fósforo convertido) se combinan para cumplir con la distribución de energía espectral con alto CRI. Para colimar la luz en los puntos concretos deseados con un ángulo de emisión determinado, se utilizan blancos sintonizables y diversos colores de luz y ópticas secundarias. La combinación de una fuente LED de varios colores con elementos ópticos puede causar falta de homogeneidad cromática en la distribución espacial y angular de la luz, que debe resolverse en el diseño óptico. Sin embargo, no hay necesidad de uniformidad perfecta en el punto de luz debido al umbral en la percepción visual del ojo humano. Por lo tanto, se requiere una descripción matemática del nivel de uniformidad del color con respecto a la percepción visual. Esta tesis está organizada en siete capítulos. Después de un capítulo inicial que presenta la motivación que ha guiado la investigación de esta tesis, en el capítulo 2 se presentan los fundamentos científicos de la uniformidad del color en luces concentradas, como son: el espacio de color aplicado CIELAB, la percepción visual del color, los fundamentos de diseño de focos respecto a los motores de luz y ópticas no formadoras de imágenes, y los últimos avances en la evaluación de la uniformidad del color en el campo de los focos. El capítulo 3 desarrolla diferentes métodos para la descripción matemática de la distribución espacial del color en un área definida, como son la diferencia de color máxima, la desviación media del color, el gradiente de la distribución espacial de color, así como la suavidad radial y axial. Cada función se refiere a los diferentes factores que influyen en la visión, los cuales necesitan un tratamiento distinto que el de los datos que se tendrán en cuenta, además de funciones de ponderación que pre- y post-procesan los datos simulados o medidos para la reducción del ruido, la luminancia de corte, la aplicación de la ponderación de luminancia, la función de sensibilidad de contraste, y la función de distribución acumulativa. En el capítulo 4, se obtiene la función de mérito Usl para la estimación de la uniformidad del color percibida en focos. Se basó en los resultados de dos conjuntos de experimentos con factor humano realizados para evaluar la percepción visual de los sujetos de los patrones de focos típicos. El primer experimento con factor humano dio lugar al orden de importancia percibida de los focos. El orden de rango percibido se utilizó para correlacionar las descripciones matemáticas de las funciones básicas y la función ponderada sobre la distribución espacial del color, que condujo a la función Usl. El segundo experimento con factor humano probó la percepción de los focos bajo condiciones ambientales diversas, con el objetivo de proporcionar una escala absoluta para Usl, para poder así sustituir la opinión subjetiva personal de los individuos por una función de mérito estandarizada. La validación de la función Usl se presenta en relación con el alcance de la aplicación y condiciones, así como las limitaciones y restricciones que se realizan en el capítulo 5. Se compararon los datos medidos y simulados de varios sistemas ópticos. Se discuten los campos de aplicación , así como validaciones y restricciones de la función. El capítulo 6 presenta el diseño del sistema de focos y su optimización. Una evaluación muestra el análisis de sistemas basados en el reflector y la lente TIR. Los sistemas ópticos simulados se comparan en la uniformidad del color Usl, sensibilidad a las sombras coloreadas, eficiencia e intensidad luminosa máxima. Se ha comprobado que no hay un sistema único que obtenga los mejores resultados en todas las categorías, y que una excelente uniformidad de color se pudo alcanzar por la conjunción de dos sistemas diferentes. Finalmente, el capítulo 7 presenta el resumen de esta tesis y la perspectiva para investigar otros aspectos. ABSTRACT Illumination with light-emitting diodes (LED) is more and more replacing traditional light sources. They provide advantages in efficiency, energy consumption, design, size and light quality. For more than 50 years, researchers have been working on LED improvements. Their main relevance for illumination is rapidly increasing. This thesis is focused on one important field of application which are spotlights. They are used to focus light on defined areas, outstanding objects in professional conditions. This high performance illumination required a defined light quality including tunable correlated color temperatures (CCT), high color rendering index (CRI), high efficiencies and bright, vivid colors. Several differently colored chips (red, blue, phosphor converted) in the LED package are combined to meet spectral power distribution with high CRI, tunable white and several light colors and secondary optics are used to collimate the light into the desired narrow spots with defined angle of emission. The combination of multi-color LED source and optical elements may cause chromatic inhomogeneities in spatial and angular light distribution which needs to solved at the optical design. However, there is no need for perfect uniformity in the spot light due to threshold in visual perception of human eye. Therefore, a mathematical description of color uniformity level with regard to visual perception is required. This thesis is organized seven seven chapters. After an initial one presenting the motivation that has guided the research of this thesis, Chapter 2 introduces the scientific basics of color uniformity in spot lights including: the applied color space CIELAB, the visual color perception, the spotlight design fundamentals with regards to light engines and nonimaging optics, and the state of the art for the evaluation of color uniformity in the far field of spotlights. Chapter 3 develops different methods for mathematical description of spatial color distribution in a defined area, which are the maximum color difference, the average color deviation, the gradient of spatial color distribution as well as the radial and axial smoothness. Each function refers to different visual influencing factors, and they need different handling of data be taken into account, along with weighting functions which pre- and post-process the simulated or measured data for noise reduction, luminance cutoff, the implementation of luminance weighting, contrast sensitivity function, and cumulative distribution function. In chapter 4, the merit function Usl for the estimation of the perceived color uniformity in spotlights is derived. It was based on the results of two sets of human factor experiments performed to evaluate the visual perception of typical spotlight patterns by subjects. The first human factor experiment resulted in the perceived rank order of the spotlights. The perceived rank order was used to correlate the mathematical descriptions of basic functions and weighted function concerning the spatial color distribution, which lead to the Usl function. The second human factor experiment tested the perception of spotlights under varied environmental conditions, with to objective to provide an absolute scale for Usl, so the subjective personal opinion of individuals could be replaced by a standardized merit function. The validation of the Usl function is presented concerning the application range and conditions as well as limitations and restrictions in carried out in chapter 5. Measured and simulated data of various optical several systems were compared. Fields of applications are discussed as well as validations and restrictions of the function. Chapter 6 presents spotlight system design and their optimization. An evaluation shows the analysis of reflector-based and TIR lens systems. The simulated optical systems are compared in color uniformity Usl , sensitivity to colored shadows, efficiency, and peak luminous intensity. It has been found that no single system which performed best in all categories, and that excellent color uniformity could be reached by two different system assemblies. Finally, chapter 7 summarizes the conclusions of the present thesis and an outlook for further investigation topics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El análisis del rendimiento en deportes juega un papel esencial en el fútbol profesional. Aunque el estudio del análisis del juego en fútbol se ha utilizado desde diferentes ámbitos y situaciones, todavía existen diferentes aspectos y componentes del juego que siguen sin estar estudiados. En este sentido existen diferentes aspectos que deben de superar los estudios previos centrados en el componente descriptivo tales como el uso de variables/ indicadores de rendimiento que no se han definido ni estudiado, la validez de los métodos observaciones que no han sido testados con los softwares específicos en fútbol, la aplicación y utilidad de los resultados, así como las limitaciones del estudio de las variables situacionales/contextuales. Con el objetivo de cubrir las citadas limitaciones se han diseñado 6 estudios independientes e inter-relacionados que tratan de estudiar los aspectos anteriormente referidos. El primer estudio evalua la fiabilidad inter-observadores de las estadísticas de juego de la empresa privada OPTA Sportsdata, estos datos son la muestra de estudio de la presente tesis doctoral. Dos grupos de observadores experimentados se requieren para analizar un partido de la liga española de manera independiente. Los resultados muestran que los eventos de equipos y porteros codificados por los inter-operadores alcanzan un acuerdo muy bueno (valores kappa entre 0.86 y 0.94). La validez inter-observadores de las acciones de juego y los datos de jugadores individuales se evaluó con elevados niveles de acuerdo (valores del coeficiente de correlación intraclase entre 0.88 hasta 1.00, el error típico estandarizado variaba entre 0.00 hasta 0.37). Los resultados sugieren que las estadísticas de juego registradas por los operadores de la empresa OPTA Sportsdata están bien entrenados y son fiables. El segundo, tercer y cuarto estudio se centran en resaltar la aplicabilidad del análisis de rendimiento en el fútbol así como para explicar en profundidad las influencias de las variables situacionales. Utilizando la técnica de los perfiles de rendimiento de jugadores y equipos de fútbol se puede evaluar y comparar de manera gráfica, fácil y visual. Así mismo, mediante esta técnica se puede controlar el efecto de las variables situacionales (localización del partido, nivel del equipo y del oponente, y el resultado final del partido). Los perfiles de rendimiento de porteros (n = 46 porteros, 744 observaciones) y jugadores de campo (n = 409 jugadores, 5288 observaciones) de la primera division professional de fútbol Española (La Liga, temporada 2012-13), los equipos (n = 496 partidos, 992 observaciones) de la UEFA Champions League (temporadas 2009-10 a 2012-13) fueron analizados registrando la media, desviación típica, mediana, cuartiles superior e inferior y el recuento de valores de cada indicador de rendimiento y evento, los cuales se presentaron en su forma tipificada y normalizada. Los valores medios de los porteros de los equipos de diferentes niveles de La Liga y de los equipos de diferente nivel de la UEFA Champions League cuando jugaban en diferentes contextos de juego y situaciones (variables situacionales) fueron comparados utilizando el ANOVA de un factor y la prueba t para muestras independientes (localización del partido, diferencias entre casa y fuera), y fueron establecidos en los perfiles de red después de unificar todos los registros en la misma escala derivada con valores estandarizados. Mientras que las diferencias de rendimiento entre los jugadores de los mejores equipos (Top3) y los peores (Bottom3) fueron comparados mediante el uso de diferencias en la magnitud del tamaño del efecto. El quinto y el sexto estudio analizaban el rendimiento del fútbol desde un punto de vista de predicción del rendimiento. El modelo linear general y el modelo lineal general mixto fue empleado para analizar la magnitud de las relaciones de los indicadores y estadísticas de juego con el resultado final del partido en función del tipo de partido (partidos ajustados o todos los partidos) en la fase de grupos de la Copa del Mundo 2014 de Brasil (n = 48 partidos, 38 partidos ajustados) y La Liga 2012-13 (n = 320 partidos ajustados). Las relaciones fueron evaluadas mediante las inferencias en la magnitud de las diferencias y se expresaron como partidos extra ganados o perdidos por cada 10 partidos mediante la variable calculada en 2 desviaciones típicas. Los resultados mostraron que, para los 48 partidos de la fase de grupos de la Copa del Mundo 2014, nueve variables tuvieron un efecto positive en la probabilidad de ganar (tiros, tiros a puerta, tiros de contraataque, tiros dentro del área, posesión de balón, pases en corto, media de secuencia de pases, duelos aéreos y entradas), cuatro tuvieron efectos negativos (tiros bloqueados, centros, regates y tarjetas amarillas), y otras 12 variables tenían efectos triviales o poco claros. Mientras que los 38 partidos ajustados, el efecto de duelos aéreos y tarjetas amarillas fueron triviales y claramente negativos respectivamente. En la La Liga, existió un efecto moderado positive para cada equipo para los tiros a puerta (3.4 victorias extras por cada 10 partidos; 99% IC ±1.0), y un efecto positivo reducido para tiros totales (1.7 victorias extrsa; ±1.0). Los efectos de la mayoría de los eventos se han relacionado con la posesión del balón, la cual obtuvo efectos negativos entre equipos (1.2 derrotas extras; ±1.0) pero un efecto positivo pequeño entra equipos (1.7 victorias extras; ±1.4). La localización del partido mostró un efecto positive reducido dentro de los equipos (1.9 victorias extras; ±0.9). Los resultados obtenidos en los perfiles y el modelado del rendimiento permiten ofrecer una información detallada y avanzada para el entrenamiento, la preparación previa a los partidos, el control de la competición y el análisis post-partido, así como la evaluación e identificación del talento de los jugadores. ABSTRACT Match performance analysis plays an important role in the modern professional football. Although the research in football match analysis is well-developed, there are still some issues and problems remaining in this field, which mainly include the lack of operational definitions of variables, reliability issues, applicability of the findings, the lack of contextual/situational variables, and focusing too much on descriptive and comparative analysis. In order to address these issues, six independent but related studies were conducted in the current thesis. The first study evaluated the inter-operator reliability of football match statistics from OPTA Sportsdata Company which is the data resourse of the thesis. Two groups of experienced operators were required to analyse a Spanish league match independently in the experiment. Results showed that team events and goalkeeper actions coded by independent operators reached a very good agreement (kappa values between 0.86 and 0.94). The inter-operator reliability of match actions and events of individual outfield players was also tested to be at a high level (intra-class correlation coefficients ranged from 0.88 to 1.00, standardised typical error varied from 0.00 to 0.37). These results suggest that the football match statistics collected by well-trained operators from OPTA Sportsdata Company are reliable. The second, third and fourth study aims to enhance the applicability of football match performance analysis and to explore deeply the influences of situational variables. By using a profiling technique, technical and tactical performances of football players and teams can be interpreted, evaluated and compared more easily and straightforwardly, meanwhile, influences and effects from situational variables (match location, strength of team and opposition, and match outcome) on the performances can be properly incorporated. Performance profiles of goalkeepers (n = 46 goalkeepers, 744 full match observations) and outfield players (n = 409 players, 5288 full match observations) from the Spanish First Division Professional Football League (La Liga, season 2012-13), teams (n = 496 matches, 992 observations) from UEFA Champions League (seasons 2009-10 to 2012-13) were set up by presenting the mean, standard deviation, median, lower and upper quartiles of the count values of each performance-related match action and event to represent their typical performances and spreads. Means of goalkeeper from different levels of team in La Liga and teams of different strength in UEFA Champions League when playing under different situational conditions were compared by using one-way ANOVA and independent sample t test (for match location, home and away differences), and were plotted into the same radar charts after unifying all the event counts by standardised score. While differences between the performances of outfield players from Top3 and from Bottom3 teams were compared by magnitude-based inferences. The fifth and sixth study aims to move from the descriptive and comparative football match analysis to a more predictive one. Generalised linear modelling and generalised mixed linear modelling were undertaken to quantify relationships of the performance-related match events, actions and variables with the match outcome in different types of games (close games and all games) in the group stage of 2014 Brazil FIFA World Cup (n = 48 games, 38 close games) and La Liga 2012-13 (n = 320 close games). Relationships were evaluated with magnitude-based inferences and were expressed as extra matches won or lost per 10 matches for an increase of two standard deviations of a variable. Results showed that, for all the 48 games in the group stage of 2014 FIFA World Cup, nine variables had clearly positive effects on the probability of winning (shot, shot on target, shot from counter attack, shot from inside area, ball possession, short pass, average pass streak, aerial advantage, and tackle), four had clearly negative effects (shot blocked, cross, dribble and red card), other 12 variabless had either trivial or unclear effects. While for the 38 close games, the effects of aerial advantage and yellow card turned to trivial and clearly negative, respectively. In the La Liga, there was a moderate positive within-team effect from shots on target (3.4 extra wins per 10 matches; 99% confidence limits ±1.0), and a small positive within-team effect from total shots (1.7 extra wins; ±1.0). Effects of most other match events were related to ball possession, which had a small negative within-team effect (1.2 extra losses; ±1.0) but a small positive between-team effect (1.7 extra wins; ±1.4). Game location showed a small positive within-team effect (1.9 extra wins; ±0.9). Results from the established performance profiles and modelling can provide detailed and straightforward information for training, pre-match preparations, in-match tactical approaches and post-match evaluations, as well as for player identification and development. 摘要 比赛表现分析在现代足球中起着举足轻重的作用。尽管如今对足球比赛表现分析的研究已经相对完善,但仍有很多不足之处。这些不足主要体现在:研究中缺乏对研究变量的清晰定义、数据信效度缺失、研究结果的实用性受限、比赛情境因素缺失以及过于集中在描述性和对比性分析等。针对这些问题,本论文通过六个独立而又相互联系的研究,进一步对足球比赛表现分析进行完善。 第一个研究对本论文的数据源--OPTA Sportsdata公司的足球比赛数据的信效度进行了实验检验。实验中,两组数据收集人员被要求对同一场西班牙足球甲级联赛的比赛进行分析。研究结果显示,两组收集人员记录下的球队比赛事件和守门员比赛行为具有高度的一致性(卡帕系数介于0.86和0.94)。收集人员输出的外场球员的比赛行为和比赛事件也具有很高的组间一致性(ICC相关系数介于0.88和1.00,标准化典型误差介于0.00和0.37)。实验结果证明了OPTA Sportsdata公司收集的足球比赛数据具有足够高的信效度。 第二、三、四个研究旨在提升足球比赛表现分析研究结果的实用性以及深度探讨比赛情境因素对足球比赛表现的影响。通过对足球运动员和运动队的比赛技战术表现进行档案创建,可以对运动员和运动队的比赛表现进行简直接而直观的呈现、评价和对比,同时,情境变量(比赛场地、球队和对手实力、比赛结果)对比赛表现的影响也可以被整合到表现档案中。本部分对2012-13赛季西班牙足球甲级联赛的参赛守门员(n = 46球员人次,744比赛场次)和外场球员(n = 409球员人次, 5288比赛场次)以及2009-10至2012-13赛季欧洲足球冠军联赛的参赛球队(n = 496比赛场次)的比赛技战术表现进行了档案创建。在表现档案中,各项比赛技战术指标的均值、标准差、中位数和大小四分位数被用来展现守门员、外场球员和球队的普遍表现和表现浮动性。方差分析(ANOVA)被用来对西甲不同水平球队的守门员、欧冠中不同水平球队在不同比赛情境下的普遍表现(各项指标的均值)进行对比,独立样本t检验被用来对比主客场比赛普遍表现的差异。数据量级推断(magnitude-based inferences)的方法则被用来对西甲前三名和最后三名球队外场球员的普遍表现进行对比分析。所有来自不同水平球队的运动员和不同水平运动队的各项比赛指标皆被转换成了标准分数,从而能把他们在各种不同比赛情境下的普遍表现(各项比赛指标的均值)投到相同的雷达图中进行直观的对比。 第五和第六个研究目的在于进行预测性足球比赛表现分析,从而跨越之前固有的描述性和对比性分析。广义线性模型和广义混合线性模型被用来对2014年巴西世界杯小组赛(n = 48 比赛场次,38小分差场次)和2012-13赛季西甲联赛(n = 320小分差场次)的比赛中各表现相关比赛事件、行为和变量与比赛结果(胜、平、负)的关系进行建模。模型中的关系通过数据量级推断(magnitude-based inferences)的方法来界定,具体表现为某个变量增加两个标准差对比赛结果的影响(每10场比赛中额外取胜或失利的场数)。研究结果显示,在2014年巴西世界杯小组赛的所有48场比赛中,9个变量(射门、射正、反击中射门、禁区内射门、控球、短传、连续传球平均次数、高空球争抢成功率和抢断)与赢球概率有清晰的正相关关系,4个变量(射门被封堵、传中、过人和红牌)与赢球概率有清晰的负相关关系,其他12个被分析的变量与赢球概率的相关关系微小或不清晰。而在38场小分差比赛中,高空球争抢成功率由正相关变为微小关系,黄牌则由微小关系变为清晰的负相关。在西甲联赛中,每一支球队增加两个标准差的“射正球门”可以给每10场比赛带来3.4场额外胜利(99%置信区间±1.0场),而所有球队作为一个整体,每增加两个标准差的“射正球门”可以给每10场比赛带来1.7场额外胜利(99%置信区间±1.0场)。其他大多数比赛相关事件与比赛结果的相关关系与“控球”相关联。每一支球队增加两个标准差的“控球”将会给每10场比赛带来1.2场额外失利(99%置信区间±1.0场),而所有球队作为一个整体,每增加两个标准差的“控球”可以给每10场比赛带来1.7场额外胜利(99%置信区间±1.4场)。与客场比赛相对,主场能给球队带来1.9 /10场额外胜利(99%置信区间±0.9场)。 比赛表现档案和模型中得出的研究结果可以为俱乐部、足球队、教练组、表现分析师和运动员提供详细而直接的参考信息。这些信息可用于训练指导、赛前备战、赛中技战术调整和赛后技战术表现分析,也可运用于足球运动员选材、培养和发展。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hoy en día, el proceso de un proyecto sostenible persigue realizar edificios de elevadas prestaciones que son, energéticamente eficientes, saludables y económicamente viables utilizando sabiamente recursos renovables para minimizar el impacto sobre el medio ambiente reduciendo, en lo posible, la demanda de energía, lo que se ha convertido, en la última década, en una prioridad. La Directiva 2002/91/CE "Eficiencia Energética de los Edificios" (y actualizaciones posteriores) ha establecido el marco regulatorio general para el cálculo de los requerimientos energéticos mínimos. Desde esa fecha, el objetivo de cumplir con las nuevas directivas y protocolos ha conducido las políticas energéticas de los distintos países en la misma dirección, centrándose en la necesidad de aumentar la eficiencia energética en los edificios, la adopción de medidas para reducir el consumo, y el fomento de la generación de energía a través de fuentes renovables. Los edificios de energía nula o casi nula (ZEB, Zero Energy Buildings ó NZEB, Net Zero Energy Buildings) deberán convertirse en un estándar de la construcción en Europa y con el fin de equilibrar el consumo de energía, además de reducirlo al mínimo, los edificios necesariamente deberán ser autoproductores de energía. Por esta razón, la envolvente del edifico y en particular las fachadas son importantes para el logro de estos objetivos y la tecnología fotovoltaica puede tener un papel preponderante en este reto. Para promover el uso de la tecnología fotovoltaica, diferentes programas de investigación internacionales fomentan y apoyan soluciones para favorecer la integración completa de éstos sistemas como elementos arquitectónicos y constructivos, los sistemas BIPV (Building Integrated Photovoltaic), sobre todo considerando el próximo futuro hacia edificios NZEB. Se ha constatado en este estudio que todavía hay una falta de información útil disponible sobre los sistemas BIPV, a pesar de que el mercado ofrece una interesante gama de soluciones, en algunos aspectos comparables a los sistemas tradicionales de construcción. Pero por el momento, la falta estandarización y de una regulación armonizada, además de la falta de información en las hojas de datos técnicos (todavía no comparables con las mismas que están disponibles para los materiales de construcción), hacen difícil evaluar adecuadamente la conveniencia y factibilidad de utilizar los componentes BIPV como parte integrante de la envolvente del edificio. Organizaciones internacionales están trabajando para establecer las normas adecuadas y procedimientos de prueba y ensayo para comprobar la seguridad, viabilidad y fiabilidad estos sistemas. Sin embargo, hoy en día, no hay reglas específicas para la evaluación y caracterización completa de un componente fotovoltaico de integración arquitectónica de acuerdo con el Reglamento Europeo de Productos de la Construcción, CPR 305/2011. Los productos BIPV, como elementos de construcción, deben cumplir con diferentes aspectos prácticos como resistencia mecánica y la estabilidad; integridad estructural; seguridad de utilización; protección contra el clima (lluvia, nieve, viento, granizo), el fuego y el ruido, aspectos que se han convertido en requisitos esenciales, en la perspectiva de obtener productos ambientalmente sostenibles, saludables, eficientes energéticamente y económicamente asequibles. Por lo tanto, el módulo / sistema BIPV se convierte en una parte multifuncional del edificio no sólo para ser física y técnicamente "integrado", además de ser una oportunidad innovadora del diseño. Las normas IEC, de uso común en Europa para certificar módulos fotovoltaicos -IEC 61215 e IEC 61646 cualificación de diseño y homologación del tipo para módulos fotovoltaicos de uso terrestre, respectivamente para módulos fotovoltaicos de silicio cristalino y de lámina delgada- atestan únicamente la potencia del módulo fotovoltaico y dan fe de su fiabilidad por un período de tiempo definido, certificando una disminución de potencia dentro de unos límites. Existe también un estándar, en parte en desarrollo, el IEC 61853 (“Ensayos de rendimiento de módulos fotovoltaicos y evaluación energética") cuyo objetivo es la búsqueda de procedimientos y metodologías de prueba apropiados para calcular el rendimiento energético de los módulos fotovoltaicos en diferentes condiciones climáticas. Sin embargo, no existen ensayos normalizados en las condiciones específicas de la instalación (p. ej. sistemas BIPV de fachada). Eso significa que es imposible conocer las efectivas prestaciones de estos sistemas y las condiciones ambientales que se generan en el interior del edificio. La potencia nominal de pico Wp, de un módulo fotovoltaico identifica la máxima potencia eléctrica que éste puede generar bajo condiciones estándares de medida (STC: irradición 1000 W/m2, 25 °C de temperatura del módulo y distribución espectral, AM 1,5) caracterizando eléctricamente el módulo PV en condiciones específicas con el fin de poder comparar los diferentes módulos y tecnologías. El vatio pico (Wp por su abreviatura en inglés) es la medida de la potencia nominal del módulo PV y no es suficiente para evaluar el comportamiento y producción del panel en términos de vatios hora en las diferentes condiciones de operación, y tampoco permite predecir con convicción la eficiencia y el comportamiento energético de un determinado módulo en condiciones ambientales y de instalación reales. Un adecuado elemento de integración arquitectónica de fachada, por ejemplo, debería tener en cuenta propiedades térmicas y de aislamiento, factores como la transparencia para permitir ganancias solares o un buen control solar si es necesario, aspectos vinculados y dependientes en gran medida de las condiciones climáticas y del nivel de confort requerido en el edificio, lo que implica una necesidad de adaptación a cada contexto específico para obtener el mejor resultado. Sin embargo, la influencia en condiciones reales de operación de las diferentes soluciones fotovoltaicas de integración, en el consumo de energía del edificio no es fácil de evaluar. Los aspectos térmicos del interior del ambiente o de iluminación, al utilizar módulos BIPV semitransparentes por ejemplo, son aún desconocidos. Como se dijo antes, la utilización de componentes de integración arquitectónica fotovoltaicos y el uso de energía renovable ya es un hecho para producir energía limpia, pero también sería importante conocer su posible contribución para mejorar el confort y la salud de los ocupantes del edificio. Aspectos como el confort, la protección o transmisión de luz natural, el aislamiento térmico, el consumo energético o la generación de energía son aspectos que suelen considerarse independientemente, mientras que todos juntos contribuyen, sin embargo, al balance energético global del edificio. Además, la necesidad de dar prioridad a una orientación determinada del edificio, para alcanzar el mayor beneficio de la producción de energía eléctrica o térmica, en el caso de sistemas activos y pasivos, respectivamente, podría hacer estos últimos incompatibles, pero no necesariamente. Se necesita un enfoque holístico que permita arquitectos e ingenieros implementar sistemas tecnológicos que trabajen en sinergia. Se ha planteado por ello un nuevo concepto: "C-BIPV, elemento fotovoltaico consciente integrado", esto significa necesariamente conocer los efectos positivos o negativos (en términos de confort y de energía) en condiciones reales de funcionamiento e instalación. Propósito de la tesis, método y resultados Los sistemas fotovoltaicos integrados en fachada son a menudo soluciones de vidrio fácilmente integrables, ya que por lo general están hechos a medida. Estos componentes BIPV semitransparentes, integrados en el cerramiento proporcionan iluminación natural y también sombra, lo que evita el sobrecalentamiento en los momentos de excesivo calor, aunque como componente estático, asimismo evitan las posibles contribuciones pasivas de ganancias solares en los meses fríos. Además, la temperatura del módulo varía considerablemente en ciertas circunstancias influenciada por la tecnología fotovoltaica instalada, la radiación solar, el sistema de montaje, la tipología de instalación, falta de ventilación, etc. Este factor, puede suponer un aumento adicional de la carga térmica en el edificio, altamente variable y difícil de cuantificar. Se necesitan, en relación con esto, más conocimientos sobre el confort ambiental interior en los edificios que utilizan tecnologías fotovoltaicas integradas, para abrir de ese modo, una nueva perspectiva de la investigación. Con este fin, se ha diseñado, proyectado y construido una instalación de pruebas al aire libre, el BIPV Env-lab "BIPV Test Laboratory", para la caracterización integral de los diferentes módulos semitransparentes BIPV. Se han definido también el método y el protocolo de ensayos de caracterización en el contexto de un edificio y en condiciones climáticas y de funcionamiento reales. Esto ha sido posible una vez evaluado el estado de la técnica y la investigación, los aspectos que influyen en la integración arquitectónica y los diferentes tipos de integración, después de haber examinado los métodos de ensayo para los componentes de construcción y fotovoltaicos, en condiciones de operación utilizadas hasta ahora. El laboratorio de pruebas experimentales, que consiste en dos habitaciones idénticas a escala real, 1:1, ha sido equipado con sensores y todos los sistemas de monitorización gracias a los cuales es posible obtener datos fiables para evaluar las prestaciones térmicas, de iluminación y el rendimiento eléctrico de los módulos fotovoltaicos. Este laboratorio permite el estudio de tres diferentes aspectos que influencian el confort y consumo de energía del edificio: el confort térmico, lumínico, y el rendimiento energético global (demanda/producción de energía) de los módulos BIPV. Conociendo el balance de energía para cada tecnología solar fotovoltaica experimentada, es posible determinar cuál funciona mejor en cada caso específico. Se ha propuesto una metodología teórica para la evaluación de estos parámetros, definidos en esta tesis como índices o indicadores que consideran cuestiones relacionados con el bienestar, la energía y el rendimiento energético global de los componentes BIPV. Esta metodología considera y tiene en cuenta las normas reglamentarias y estándares existentes para cada aspecto, relacionándolos entre sí. Diferentes módulos BIPV de doble vidrio aislante, semitransparentes, representativos de diferentes tecnologías fotovoltaicas (tecnología de silicio monocristalino, m-Si; de capa fina en silicio amorfo unión simple, a-Si y de capa fina en diseleniuro de cobre e indio, CIS) fueron seleccionados para llevar a cabo una serie de pruebas experimentales al objeto de demostrar la validez del método de caracterización propuesto. Como resultado final, se ha desarrollado y generado el Diagrama Caracterización Integral DCI, un sistema gráfico y visual para representar los resultados y gestionar la información, una herramienta operativa útil para la toma de decisiones con respecto a las instalaciones fotovoltaicas. Este diagrama muestra todos los conceptos y parámetros estudiados en relación con los demás y ofrece visualmente toda la información cualitativa y cuantitativa sobre la eficiencia energética de los componentes BIPV, por caracterizarlos de manera integral. ABSTRACT A sustainable design process today is intended to produce high-performance buildings that are energy-efficient, healthy and economically feasible, by wisely using renewable resources to minimize the impact on the environment and to reduce, as much as possible, the energy demand. In the last decade, the reduction of energy needs in buildings has become a top priority. The Directive 2002/91/EC “Energy Performance of Buildings” (and its subsequent updates) established a general regulatory framework’s methodology for calculation of minimum energy requirements. Since then, the aim of fulfilling new directives and protocols has led the energy policies in several countries in a similar direction that is, focusing on the need of increasing energy efficiency in buildings, taking measures to reduce energy consumption, and fostering the use of renewable sources. Zero Energy Buildings or Net Zero Energy Buildings will become a standard in the European building industry and in order to balance energy consumption, buildings, in addition to reduce the end-use consumption should necessarily become selfenergy producers. For this reason, the façade system plays an important role for achieving these energy and environmental goals and Photovoltaic can play a leading role in this challenge. To promote the use of photovoltaic technology in buildings, international research programs encourage and support solutions, which favors the complete integration of photovoltaic devices as an architectural element, the so-called BIPV (Building Integrated Photovoltaic), furthermore facing to next future towards net-zero energy buildings. Therefore, the BIPV module/system becomes a multifunctional building layer, not only physically and functionally “integrated” in the building, but also used as an innovative chance for the building envelope design. It has been found in this study that there is still a lack of useful information about BIPV for architects and designers even though the market is providing more and more interesting solutions, sometimes comparable to the existing traditional building systems. However at the moment, the lack of an harmonized regulation and standardization besides to the non-accuracy in the technical BIPV datasheets (not yet comparable with the same ones available for building materials), makes difficult for a designer to properly evaluate the fesibility of this BIPV components when used as a technological system of the building skin. International organizations are working to establish the most suitable standards and test procedures to check the safety, feasibility and reliability of BIPV systems. Anyway, nowadays, there are no specific rules for a complete characterization and evaluation of a BIPV component according to the European Construction Product Regulation, CPR 305/2011. BIPV products, as building components, must comply with different practical aspects such as mechanical resistance and stability; structural integrity; safety in use; protection against weather (rain, snow, wind, hail); fire and noise: aspects that have become essential requirements in the perspective of more and more environmentally sustainable, healthy, energy efficient and economically affordable products. IEC standards, commonly used in Europe to certify PV modules (IEC 61215 and IEC 61646 respectively crystalline and thin-film ‘Terrestrial PV Modules-Design Qualification and Type Approval’), attest the feasibility and reliability of PV modules for a defined period of time with a limited power decrease. There is also a standard (IEC 61853, ‘Performance Testing and Energy Rating of Terrestrial PV Modules’) still under preparation, whose aim is finding appropriate test procedures and methodologies to calculate the energy yield of PV modules under different climate conditions. Furthermore, the lack of tests in specific conditions of installation (e.g. façade BIPV devices) means that it is difficult knowing the exact effective performance of these systems and the environmental conditions in which the building will operate. The nominal PV power at Standard Test Conditions, STC (1.000 W/m2, 25 °C temperature and AM 1.5) is usually measured in indoor laboratories, and it characterizes the PV module at specific conditions in order to be able to compare different modules and technologies on a first step. The “Watt-peak” is not enough to evaluate the panel performance in terms of Watt-hours of various modules under different operating conditions, and it gives no assurance of being able to predict the energy performance of a certain module at given environmental conditions. A proper BIPV element for façade should take into account thermal and insulation properties, factors as transparency to allow solar gains if possible or a good solar control if necessary, aspects that are linked and high dependent on climate conditions and on the level of comfort to be reached. However, the influence of different façade integrated photovoltaic solutions on the building energy consumption is not easy to assess under real operating conditions. Thermal aspects, indoor temperatures or luminance level that can be expected using building integrated PV (BIPV) modules are not well known. As said before, integrated photovoltaic BIPV components and the use of renewable energy is already a standard for green energy production, but would also be important to know the possible contribution to improve the comfort and health of building occupants. Comfort, light transmission or protection, thermal insulation or thermal/electricity power production are aspects that are usually considered alone, while all together contribute to the building global energy balance. Besides, the need to prioritize a particular building envelope orientation to harvest the most benefit from the electrical or thermal energy production, in the case of active and passive systems respectively might be not compatible, but also not necessary. A holistic approach is needed to enable architects and engineers implementing technological systems working in synergy. A new concept have been suggested: “C-BIPV, conscious integrated BIPV”. BIPV systems have to be “consciously integrated” which means that it is essential to know the positive and negative effects in terms of comfort and energy under real operating conditions. Purpose of the work, method and results The façade-integrated photovoltaic systems are often glass solutions easily integrable, as they usually are custommade. These BIPV semi-transparent components integrated as a window element provides natural lighting and shade that prevents overheating at times of excessive heat, but as static component, likewise avoid the possible solar gains contributions in the cold months. In addition, the temperature of the module varies considerably in certain circumstances influenced by the PV technology installed, solar radiation, mounting system, lack of ventilation, etc. This factor may result in additional heat input in the building highly variable and difficult to quantify. In addition, further insights into the indoor environmental comfort in buildings using integrated photovoltaic technologies are needed to open up thereby, a new research perspective. This research aims to study their behaviour through a series of experiments in order to define the real influence on comfort aspects and on global energy building consumption, as well as, electrical and thermal characteristics of these devices. The final objective was to analyze a whole set of issues that influence the global energy consumption/production in a building using BIPV modules by quantifying the global energy balance and the BIPV system real performances. Other qualitative issues to be studied were comfort aspect (thermal and lighting aspects) and the electrical behaviour of different BIPV technologies for vertical integration, aspects that influence both energy consumption and electricity production. Thus, it will be possible to obtain a comprehensive global characterization of BIPV systems. A specific design of an outdoor test facility, the BIPV Env-lab “BIPV Test Laboratory”, for the integral characterization of different BIPV semi-transparent modules was developed and built. The method and test protocol for the BIPV characterization was also defined in a real building context and weather conditions. This has been possible once assessed the state of the art and research, the aspects that influence the architectural integration and the different possibilities and types of integration for PV and after having examined the test methods for building and photovoltaic components, under operation conditions heretofore used. The test laboratory that consists in two equivalent test rooms (1:1) has a monitoring system in which reliable data of thermal, daylighting and electrical performances can be obtained for the evaluation of PV modules. The experimental set-up facility (testing room) allows studying three different aspects that affect building energy consumption and comfort issues: the thermal indoor comfort, the lighting comfort and the energy performance of BIPV modules tested under real environmental conditions. Knowing the energy balance for each experimented solar technology, it is possible to determine which one performs best. A theoretical methodology has been proposed for evaluating these parameters, as defined in this thesis as indices or indicators, which regard comfort issues, energy and the overall performance of BIPV components. This methodology considers the existing regulatory standards for each aspect, relating them to one another. A set of insulated glass BIPV modules see-through and light-through, representative of different PV technologies (mono-crystalline silicon technology, mc-Si, amorphous silicon thin film single junction, a-Si and copper indium selenide thin film technology CIS) were selected for a series of experimental tests in order to demonstrate the validity of the proposed characterization method. As result, it has been developed and generated the ICD Integral Characterization Diagram, a graphic and visual system to represent the results and manage information, a useful operational tool for decision-making regarding to photovoltaic installations. This diagram shows all concepts and parameters studied in relation to each other and visually provides access to all the results obtained during the experimental phase to make available all the qualitative and quantitative information on the energy performance of the BIPV components by characterizing them in a comprehensive way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Following striate cortex damage in monkeys and humans there can be residual function mediated by parallel visual pathways. In humans this can sometimes be associated with a “feeling” that something has happened, especially with rapid movement or abrupt onset. For less transient events, discriminative performance may still be well above chance even when the subject reports no conscious awareness of the stimulus. In a previous study we examined parameters that yield good residual visual performance in the “blind” hemifield of a subject with unilateral damage to the primary visual cortex. With appropriate parameters we demonstrated good discriminative performance, both with and without conscious awareness of a visual event. These observations raise the possibility of imaging the brain activity generated in the “aware” and the “unaware” modes, with matched levels of discrimination performance, and hence of revealing patterns of brain activation associated with visual awareness. The intact hemifield also allows a comparison with normal vision. Here we report the results of a functional magnetic resonance imaging study on the same subject carried out under aware and unaware stimulus conditions. The results point to a shift in the pattern of activity from neocortex in the aware mode, to subcortical structures in the unaware mode. In the aware mode prestriate and dorsolateral prefrontal cortices (area 46) are active. In the unaware mode the superior colliculus is active, together with medial and orbital prefrontal cortical sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At early stages in visual processing cells respond to local stimuli with specific features such as orientation and spatial frequency. Although the receptive fields of these cells have been thought to be local and independent, recent physiological and psychophysical evidence has accumulated, indicating that the cells participate in a rich network of local connections. Thus, these local processing units can integrate information over much larger parts of the visual field; the pattern of their response to a stimulus apparently depends on the context presented. To explore the pattern of lateral interactions in human visual cortex under different context conditions we used a novel chain lateral masking detection paradigm, in which human observers performed a detection task in the presence of different length chains of high-contrast-flanked Gabor signals. The results indicated a nonmonotonic relation of the detection threshold with the number of flankers. Remote flankers had a stronger effect on target detection when the space between them was filled with other flankers, indicating that the detection threshold is caused by dynamics of large neuronal populations in the neocortex, with a major interplay between excitation and inhibition. We considered a model of the primary visual cortex as a network consisting of excitatory and inhibitory cell populations, with both short- and long-range interactions. The model exhibited a behavior similar to the experimental results throughout a range of parameters. Experimental and modeling results indicated that long-range connections play an important role in visual perception, possibly mediating the effects of context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relationship between brain activity and reading performance was examined to test the hypothesis that dyslexia involves a deficit in a specific visual pathway known as the magnocellular (M) pathway. Functional magnetic resonance imaging was used to measure brain activity in dyslexic and control subjects in conditions designed to preferentially stimulate the M pathway. Dyslexics showed reduced activity compared with controls both in the primary visual cortex and in a secondary cortical visual area (MT+) that is believed to receive a strong M pathway input. Most importantly, significant correlations were found between individual differences in reading rate and brain activity. These results support the hypothesis for an M pathway abnormality in dyslexia and imply a strong relationship between the integrity of the M pathway and reading ability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In two experiments, electric brain waves of 14 subjects were recorded under several different conditions to study the invariance of brain-wave representations of simple patches of colors and simple visual shapes and their names, the words blue, circle, etc. As in our earlier work, the analysis consisted of averaging over trials to create prototypes and test samples, to both of which Fourier transforms were applied, followed by filtering and an inverse transformation to the time domain. A least-squares criterion of fit between prototypes and test samples was used for classification. The most significant results were these. By averaging over different subjects, as well as trials, we created prototypes from brain waves evoked by simple visual images and test samples from brain waves evoked by auditory or visual words naming the visual images. We correctly recognized from 60% to 75% of the test-sample brain waves. The general conclusion is that simple shapes such as circles and single-color displays generate brain waves surprisingly similar to those generated by their verbal names. These results, taken together with extensive psychological studies of auditory and visual memory, strongly support the solution proposed for visual shapes, by Bishop Berkeley and David Hume in the 18th century, to the long-standing problem of how the mind represents simple abstract ideas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

What is the role of selective attention in visual perception? Before answering this question, it is necessary to differentiate between attentional mechanisms that influence the identification of a stimulus from those that operate after perception is complete. Cognitive neuroscience techniques are particularly well suited to making this distinction because they allow different attentional mechanisms to be isolated in terms of timing and/or neuroanatomy. The present article describes the use of these techniques in differentiating between perceptual and postperceptual attentional mechanisms and then proposes a specific role of attention in visual perception. Specifically, attention is proposed to resolve ambiguities in neural coding that arise when multiple objects are processed simultaneously. Evidence for this hypothesis is provided by two experiments showing that attention—as measured electrophysiologically—is allocated to visual search targets only under conditions that would be expected to lead to ambiguous neural coding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blindsight is a phenomenon in which human patients with damage to striate cortex deny any visual sensation in the resultant visual field defect but can nonetheless detect and localize stimuli when persuaded to guess. Although monkeys with striate lesions have also been shown to exhibit some residual vision, it is not yet clear to what extent the residual capacities in monkeys parallel the phenomenon of human blindsight. To clarify this issue, we trained two monkeys with unilateral lesions of striate cortex to make saccadic eye movements to visual targets in both hemifields under two conditions. In the condition analogous to clinical perimetry, they failed to initiate saccades to targets presented in the contralateral hemifield and thus appeared "blind." Only in the condition where the fixation point was turned off simultaneously with the onset of the target--signaling the animal to respond at the appropriate time--were monkeys able to localize targets contralateral to the striate lesion. These results indicate that the conditions under which residual vision is demonstrable are similar for monkeys with striate cortex damage and humans with blindsight.