977 resultados para VENOUS DOPPLER
Resumo:
BACKGROUND: The only available score to assess the risk for fatal bleeding in patients with venous thromboembolism (VTE) has not been validated yet. METHODS: We used the RIETE database to validate the risk-score for fatal bleeding within the first 3 months of anticoagulation in a new cohort of patients recruited after the end of the former study. Accuracy was measured using the ROC curve analysis. RESULTS: As of December 2011, 39,284 patients were recruited in RIETE. Of these, 15,206 had not been included in the former study, and were considered to validate the score. Within the first 3 months of anticoagulation, 52 patients (0.34%; 95% CI: 0.27-0.45) died of bleeding. Patients with a risk score of <1.5 points (64.1% of the cohort) had a 0.10% rate of fatal bleeding, those with a score of 1.5-4.0 (33.6%) a rate of 0.72%, and those with a score of >4 points had a rate of 1.44%. The c-statistic for fatal bleeding was 0.775 (95% CI 0.720-0.830). The score performed better for predicting gastrointestinal (c-statistic, 0.869; 95% CI: 0.810-0.928) than intracranial (c-statistic, 0.687; 95% CI: 0.568-0.806) fatal bleeding. The score value with highest combined sensitivity and specificity was 1.75. The risk for fatal bleeding was significantly increased (odds ratio: 7.6; 95% CI 3.7-16.2) above this cut-off value. CONCLUSIONS: The accuracy of the score in this validation cohort was similar to the accuracy found in the index study. Interestingly, it performed better for predicting gastrointestinal than intracranial fatal bleeding.
Resumo:
OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).
Resumo:
A venous ulcer is the end result of a long pathological process where venous hypertension represents the principal cause of a number of complications. The physiotherapist by adapting various different therapeutic approaches improves the vascular, joint and respiratory problems of these patients.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).
Resumo:
BACKGROUND: The influence of recent immobilization or surgery on mortality in cancer patients with venous thromboembolism (VTE) has not been thoroughly studied. METHODS: We used the RIETE Registry data to compare the 3-month mortality rate in cancer patients with VTE, with patients categorized according to the presence of recent immobilization, surgery or neither. The major outcomes were fatal pulmonary embolism (PE) and fatal bleeding within the first 3 months. RESULTS: Of 6,746 patients with active cancer and acute VTE, 1,224 (18%) had recent immobilization, 1,055 (16%) recent surgery, and 4,467 (66%) had neither. The all-cause mortality was 23.4% (95% CI: 22.4-24.5), and the PE-related mortality: 2.5% (95% CI: 2.1-2.9). Four in every ten patients dying of PE had recent immobilization (37%) or surgery (5.4%). Only 28% of patients with immobilization had received prophylaxis, as compared with 67% of the surgical. Fatal PE was more common in patients with recent immobilization (5.0%; 95% CI: 3.9-6.3) than in those with surgery (0.8%; 95% CI: 0.4-1.6) or neither (2.2%; 95% CI: 1.8-2.6). On multivariate analysis, patients with immobilization were at an increased risk for fatal PE (odds ratio: 1.8; 95% CI: 1.2-2.5). CONCLUSIONS: One in every three cancer patients dying of PE had recent immobilization for ≥ 4 days. Many of these deaths could have been prevented with adequate thromboprophylaxis.
Resumo:
Estudi retrospectiu per analitzar la incidència, factors de risc i tractament de la hemoglobinuria macroscòpica i oliguria després del tractament de malformacions venoses amb escleroteràpia. Un total de 475 procediments es van realitzar en 131 malalts usant etanol, sulfat tetradecil sòdic o ambdos. Hemoglobinuria temporal es va donar després del 34% de procediments i el 57% d’aquests es van asociar amb oliguria temporal. Aquest risc augmenta amb el increment de dosis. La resolució de la hemoglobinuria i oliguria va ser satisfactòria en tots els malalts. El risc d’hemoglobinuria augmenta a les malformacions que afecten les extremitats inferiors i a les de localitzacions mútiples.
Resumo:
La rigidez arterial es un parámetro establecido dentro de la valoración del riesgo cardio-vascular. Actualmente disponemos de múltiples métodos para determinar la velocidad de onda de pulso (VOP) y entre ellos los más utilizados son los métodos mecánicos, como el Complior o el Sphigmocor, que precisan de dispositivos específicos y una inversión importante en aprendizaje y tiempo de exploración. La utilización del doppler guiado por ecografía 2D es una buena alternativa a estos métodos. Realizamos un estudio comparativo para evaluar la fiabilidad del eco-doppler en la medida de la VOP carótida-femoral respecto al método Complior. Se estudió la VOP carótida-femoral utilizando los dos sistemas en 40 pacientes, mostrando ambos métodos muy buena concordancia (R=0’91). En el análisis de reproducibilidad de la VOP por doppler no se hallaron diferencias intra e interobservador. En base a los resultados, el estudio demuestra que la ecografía doppler puede ser usada para medir la VOP aórtica de manera fiable y reproducible, similar otros métodos más establecidos.
Resumo:
Venous thromboembolism (VTE) is common and has a high impact on morbidity, mortality, and costs of care. Although most of the patients with VTE are aged ≥65 years, there is little data about the medical outcomes in the elderly with VTE. The Swiss Cohort of Elderly Patients with VTE (SWITCO65+) is a prospective multicenter cohort study of in- and outpatients aged ≥65 years with acute VTE from all five Swiss university and four high-volume non-university hospitals. The goal is to examine which clinical and biological factors and processes of care drive short- and long-term medical outcomes, health-related quality of life, and medical resource utilization in elderly patients with acute VTE. The cohort also includes a large biobank with biological material from each participant. From September 2009 to March 2012, 1,863 elderly patients with VTE were screened and 1003 (53.8 %) were enrolled in the cohort. Overall, 51.7 % of patients were aged ≥75 years and 52.7 % were men. By October 16, 2012, after an average follow-up time of 512 days, 799 (79.7 %) patients were still actively participating. SWITCO65+ is a unique opportunity to study short- and long-term outcomes in elderly patients with VTE. The Steering Committee encourages national and international collaborative research projects related to SWITCO65+, including sharing anonymized data and biological samples.
Resumo:
Abstract Introduction The primary function of the contractile vascular smooth muscle cells (cVSMCs) is the regulation of the vascular contractility which means the adaptation of the vascular tonus in response to the modulation of the blood pressure and blood flow. The cVSMCs are essentially quiescent, and therefore their synthesis rate is very limited. They are characterized by the expression of contractile proteins specific to the muscular tissue including myosin, h-‐caldesmon and <-‐smooth muscle actin (〈-‐SMA). These contractile cells are strongly represented in the media layer of the arterial wall and, in a smaller proportion, of the vein wall. Their typical stretched-‐out morphology allows recognizing them by a histological analysis. They do not produce any extracellular matrix (ECM), and do not migrate through the different layers of the vessel wall, and are not directly involved in the development of intimal hyperplasia (IH). Neointimal formation occurs after endothelial disruption leading to complex molecular and biological mechanisms. The de-‐differentiation of cVSMCs into synthetic VSMCs (sVSMCs) is mentioned as a key element. These non mature cells are able to proliferate and produce ECM. The characterization of the vascular smooth muscle cells (VSMCs) from healthy and stenosed vascular tissues will contribue to the understanding of the different biological processes leading to IH and will be useful for the development of new therapies to interfere with the cVSMCs growth and migration. The aim of our research was to quantify the proportion of cVSMCs and sVSMCs into the healthy and pathologic human blood vessel wall and to characterize their phenotype. Methods We selected 23 specimens of arterial and venous segments from 18 patients. All these specimens were stored in the biobank from the thoracic and vascular surgery departement. 4 groups were designed (group 1 :arteries without lesions (n=3) ;group 2 : veins without lesions (n=1); group 3: arteries with stenosis (n=9); group 4: veins with stenosis (n=10)). Histology: 5µm-‐sections were made from each sample embedded in paraffin wax and further stained with hematoxylin & eosin (HE), Van Gieson's stain (VGEL) and Masson's Trichrome (TMB). Pathologic tissues were defined using the label that was given to the macroscopic samples by the surgeon and also, based on the histological analysis with HE and VGEL evaluating the presence of a thickened intima. The same was done to the control samples evaluating the absence of thickening. Immunohistochemistry : The primary antibodies were used :〈-‐SMA, vimentin, h-‐ caldesmon, calponin, smooth muscle-myosin heavy chain (SM-‐MHC), tropomyosin-‐4, retinol binding protein-‐1 (RBP-‐1), nonmuscle-‐myosin heavy chain-‐B (NM-‐MHC-‐B), Von Willebrand factor (VWF). A semi-‐quantitative assessment of the intensity of each sample stained was performed. Western Blot : Segments of arteries and veins were analyzed using the following primary antibodies :〈-‐SMA, Calponin, SM-‐MHC, NM-‐MHC-‐B. The given results were then normalized with tubulin. Results Our data showed that, when using immunohistochemistry analysis we found that〈-‐SMA was mostly expressed in control arteries, whereas NM-‐MHC-‐B in the pathologic ones. Using SM-‐MHC, calponin, vimentin and caldesmon we found no significative differences in the expression of these proteins in the control and in the pathologic samples. Western Blot analysis showed an inverse correlation between healthy and pathological samples as <-‐ SMA was more expressed in the pathological samples, while NM-‐MHC-‐B in the control group; SM-‐MHC and calponin were mostly expressed in the pathologic samples. Conclusion Our study showed no clear differences between stenotic and control arterial and venous segments using semi-‐quantitative assessement by immunohistochemistry. Western Blot showed a significant increased expression of 〈-‐SMA, calponin and SM-‐MHC in the arteries with stenosis, while NM-‐MHC-‐B was mostly expressed in the arteries without lesions. Further studies are needed to track the lineage of VSMCs to understand the mechanisms leading toIH.