999 resultados para Ultrassonografia de Doppler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the author introduces a novel method for Geo Localisation via Doppler Radar. The area of research is in the three dimensional space using amplitude and magnitude measurements. Geo Localisation in mobile applications is a useful technology that enables monitoring and gathering information about objects of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real-time respiratory measurement with Doppler Radar has an important advantage in the monitoring of certain conditions such as sleep apnoea, sudden infant death syndrome (SIDS), and many other general clinical uses requiring fast nonwearable and non-contact measurement of the respiratory function. In this paper, we demonstrate the feasibility of using Doppler Radar in measuring the basic respiratory frequencies (via fast Fourier transform) for four different types of breathing scenarios: normal breathing, rapid breathing, slow inhalation-fast exhalation, and fast inhalation-slow exhalation conducted in a laboratory environment. A high correlation factor was achieved between the Doppler Radar-based measurements and the conventional measurement device, a respiration strap. We also extended this work from basic signal acquisition to extracting detailed features of breathing function (I: E ratio). This facilitated additional insights into breathing activity and is likely to trigger a number of new applications in respiratory medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiration detection using microwave Doppler radar has attracted significant interest primarily due to its unobtrusive form of measurement. With less preparation in comparison with attaching physical sensors on the body or wearing special clothing, Doppler radar for respiration detection and monitoring is particularly useful for long-term monitoring applications such as sleep studies (i.e. sleep apnoea, SIDS). However, motion artefacts and interference from multiple sources limit the widespread use and the scope of potential applications of this technique. Utilising the recent advances in independent component analysis (ICA) and multiple antenna configuration schemes, this work investigates the feasibility of decomposing respiratory signatures into each subject from the Doppler-based measurements. Experimental results demonstrated that FastICA is capable of separating two distinct respiratory signatures from two subjects adjacent to each other even in the presence of apnoea. In each test scenario, the separated respiratory patterns correlate closely to the reference respiration strap readings. The effectiveness of FastICA in dealing with the mixed Doppler radar respiration signals confirms its applicability in healthcare applications, especially in long-term home-based monitoring as it usually involves at least two people in the same environment (i.e. two people sleeping next to each other). Further, the use of FastICA to separate involuntary movements such as the arm swing from the respiratory signatures of a single subject was explored in a multiple antenna environment. The separated respiratory signal indeed demonstrated a high correlation with the measurements made by a respiratory strap used currently in clinical settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Non-contact detection characteristic of Doppler radar provides an unobtrusive means of respiration detection and monitoring. This avoids additional preparations such as physical sensor attachment or special clothing. Furthermore, robustness of Doppler radar against environmental factors reduce environmental constraints and strengthens the possibility of employing Doppler radar as a practical biomedical devices in the future particularly in long term monitoring applications such as in sleep studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AZEVEDO, George Dantas de et al. Raloxifene therapy does not affect uterine blood flow in postmenopausal women: a transvaginal Doppler study. Maturitas, Amsterdam, v.47, n.3, p.195-200, 2004

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo neste estudo foi estimar as correlações genéticas entre escores visuais e características de carcaça medidas por ultrassonografia em bovinos da raça Nelore utilizando a estatística bayesiana por meio da Amostragem de Gibbs, sob modelo animal linear-limiar. Foram estudadas as características categóricas morfológicas de musculosidade, estrutura física, conformação e sacro, avaliadas aos 15 e 22 meses de idade. Para as características de carcaça, foram avaliadas as características área de olho-de-lombo, espessura de gordura subcutânea, espessura de gordura subcutânea na garupa e altura na garupa. Os escores visuais devem ser empregados como critérios de seleção para aumentar o progresso genético para a característica área de olhode-lombo e, consequentemente, melhorar o rendimento de carcaça. As estimativas de correlação genética obtidas para musculosidade com espessura de gordura subcutânea e espessura de gordura subcutânea na garupa indicaram que a seleção para musculosidade pode levar a animais com melhor acabamento de carcaça. A seleção para a estrutura física e conformação aos 15 e 22 meses de idade pode promover resposta correlacionada para o aumento da altura na garupa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Estudo comparativo da receptividade (colaboração) e sensibilidade da seriografia do esôfago, estômago e duodeno em relação à ultrassonografia do esôfago intra-abdominal em pacientes com suspeita de refluxo gastroesofágico. MATERIAIS E MÉTODOS: Foram incluídos no estudo 42 pacientes pediátricos (26 masculinos, com idade média de 33,64 ± 34,33 meses, e 16 femininos, com idade média de 31,02 ± 35,56 meses) com suspeita de refluxo gastroesofágico, os quais foram submetidos, inicialmente, a seriografia do esôfago, estômago e duodeno, e posteriormente, a ultrassonografia do esôfago intra-abdominal. RESUL-TADOS: A análise estatística comparativa entre os sexos e as idades sugere não haver evidência de associação com a colaboração, tanto para a seriografia do esôfago, estômago e duodeno como para a ultrassonografia do esôfago intra-abdominal. Entretanto, na classificação quanto ao tipo de colaboração, a técnica de seriografia do esôfago, estômago e duodeno apresentou menos de 50% de colaboração, enquanto 80,49% dos pacientes colaboraram com a ultrassonografia do esôfago intra-abdominal. Quanto à sensibilidade do diagnóstico de refluxo gastroesofágico, a técnica de ultrassonografia do esôfago intra-abdominal (85,7%) foi significativamente superior à de seriografia do esôfago, estômago e duodeno (47,6%). CONCLUSÃO: O presente estudo sugere que se proceda a ultrassonografia do esôfago intra-abdominal, mesmo na ausência de refluxo gastroesofágico na seriografia do esôfago, estômago e duodeno.