904 resultados para Tricuspid Prosthetic Valve Stenosis
Resumo:
Abstract Purpose Aortic stenosis (AS) is the most common valvular abnormality in the elderly population. For inoperable patients or those at high-risk for surgery, transcatheter aortic valve implantation (TAVI) has become an alternative therapeutic option. The aim of the “Comprehensive geriatric assessment for transcatheter aortic valve implantation” (CGA-TAVI) registry is to evaluate the effectiveness of TAVI from the perspective of the geriatrician and to identify patient characteristics and indicators related to complications and clinical benefits for patients with symptomatic severe calcified degenerative AS undergoing TAVI. Materials and methods The CGA-TAVI registry is an international, multi-center, prospective, observational registry across Europe with consecutive patient enrolment. The registry will enrol up to 200 patients with AS undergoing TAVI, starting August 2013. CGA-TAVI has two co-primary objectives: (1) Establish predictive value of Comprehensive geriatric assessment (CGA) for mortality and/or hospitalization in TAVI patients. (2) Demonstrate CGA changes within 3 months after TAVI. Secondary objectives are: (1) Establish predictive value of CGA in TAVI patients for all-cause hospitalization, TAVI-related hospitalization, and nursing home admission. (2) Develop a comprehensive score for the assessment of TAVI patient prognosis. Conclusions The data obtained from the CGA-TAVI registry will supplement previous results to document the potential value of the effectiveness of TAVI from the perspective of geriatricians and will allow the assessment of the predictive value of CGA for mortality and/or hospitalization in elderly TAVI patients. Keywords Aortic stenosis; Transcatheter aortic valve implantation (TAVI); Comprehensive geriatric assessment (CGA); Registry; Predictor
Resumo:
B-type natriuretic peptide (BNP) levels are elevated in patients with aortic stenosis (AS) and decrease acutely after replacement of the stenotic valve. The long-term prognostic value of BNP after transcatheter aortic valve implantation (TAVI) and the relative prognostic utility of single versus serial peri-interventional measurements of BNP and N-terminal prohormone BNP (NT-pro-BNP) are unknown. This study sought to determine the impact of BNP levels on long-term outcomes after TAVI and to compare the utility of BNP versus NT-pro-BNP measured before and after intervention. We analyzed 340 patients with severe AS and baseline pre-TAVI assessment of BNP. In 219 patients, BNP and NT-pro-BNP were measured serially before and after intervention. Clinical outcomes over 2 years were recorded. Patients with high baseline BNP (higher tertile ≥591 pg/ml) had increased risk of all-cause mortality (adjusted hazard ratio 3.16, 95% confidence interval 1.84 to 5.42; p <0.001) and cardiovascular death at 2 years (adjusted hazard ratio 3.37, 95% confidence interval 1.78 to 6.39; p <0.001). Outcomes were most unfavorable in patients with persistently high BNP before and after intervention. Comparing the 2 biomarkers, NT-pro-BNP levels measured after TAVI showed the highest prognostic discrimination for 2-year mortality (area under the curve 0.75; p <0.01). Baseline-to-discharge reduction, but not baseline levels of BNP, was related to New York Heart Association functional improvement. In conclusion, high preintervention BNP independently predicts 2-year outcomes after TAVI, particularly when elevated levels persist after the intervention. BNP and NT-pro-BNP and their serial periprocedural changes provide complementary prognostic information for symptomatic improvement and survival.
Resumo:
OBJECTIVE In patients with aortic stenosis, left ventricular systolic torsion (pT) is increased to overcome excessive afterload. This study assessed left ventricular torsion before and immediately after surgical valve replacement and tested the instant effect of fluid loading. DESIGN Prospective, clinical single-center study. SETTING Intensive care unit of a university hospital. PARTICIPANTS 12 patients undergoing elective aortic valve replacement for aortic stenosis. INTERVENTIONS Echocardiography was performed on the day before surgery, within 18 hours after surgery including a fluid challenge, and after 2.5 years. MEASUREMENTS AND MAIN RESULTS pT decreased early postoperatively by 21.2% (23.4° ± 5.6° to 18.4° ± 6.9°; p = 0.012) and reached preoperative values at 2.5 years follow-up (24 ± 7). Peak diastolic untwisting velocity occurred later early postoperatively (13% ± 8% to 21% ± 9.4%; p = 0.019) and returned toward preoperative values at follow-up (10.2 ± 4.7°). The fluid challenge increased central venous pressure (8 ± 4 mmHg to 11 ± 4 mmHg; p = 0.003) and reduced peak systolic torsion velocity (138.7 ± 37.6/s to 121.3 ± 32/s; p = 0.032). pT decreased in 3 and increased in 8 patients after fluid loading. Patients whose pT increased had higher early mitral inflow velocity postoperatively (p = 0.04) than those with decreasing pT. Patients with reduced pT after fluid loading received more fluids (p = 0.04) and had a higher positive fluid balance during the intensive care unit stay (p = 0.03). Torsion after fluid loading correlated with total fluid input (p = 0.001) and cumulative fluid balance (p = 0.002). CONCLUSIONS pT decreased early after aortic valve replacement but remained elevated despite elimination of aortic stenosis. After 2.5 years, torsion had returned to preoperative levels.
Resumo:
BACKGROUND Sutureless aortic valve replacement (SU-AVR) has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to reduce cross-clamp and cardiopulmonary bypass (CPB) duration and thereby improve surgical outcomes and facilitate a minimally invasive approach suitable for higher risk patients. The present systematic review and meta-analysis aims to assess the safety and efficacy of SU-AVR approach in the current literature. METHODS Electronic searches were performed using six databases from their inception to January 2014. Relevant studies utilizing sutureless valves for aortic valve implantation were identified. Data were extracted and analyzed according to predefined clinical endpoints. RESULTS Twelve studies were identified for inclusion of qualitative and quantitative analyses, all of which were observational reports. The minimally invasive approach was used in 40.4% of included patients, while 22.8% underwent concomitant coronary bypass surgery. Pooled cross-clamp and CPB duration for isolated AVR was 56.7 and 46.5 minutes, respectively. Pooled 30-day and 1-year mortality rates were 2.1% and 4.9%, respectively, while the incidences of strokes (1.5%), valve degenerations (0.4%) and paravalvular leaks (PVL) (3.0%) were acceptable. CONCLUSIONS The evaluation of current observational evidence suggests that sutureless aortic valve implantation is a safe procedure associated with shorter cross-clamp and CPB duration, and comparable complication rates to the conventional approach in the short-term.
Resumo:
Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
BACKGROUND Anticoagulation is required during transcatheter aortic valve replacement (TAVR) procedures. Although an optimal regimen has not been determined, heparin is mainly used. Direct thrombin inhibition with bivalirudin may be an effective alternative to heparin as the procedural anticoagulant agent in this setting. OBJECTIVES The goal of this study was to determine whether bivalirudin offers an alternative to heparin as the procedural anticoagulant agent in patients undergoing TAVR. METHODS A total of 802 patients with aortic stenosis were randomized to undergo transfemoral TAVR with bivalirudin versus unfractionated heparin during the procedure. The 2 primary endpoints were major bleeding within 48 h or before hospital discharge (whichever occurred first) and 30-day net adverse clinical events, defined as the combination of major adverse cardiovascular events (all-cause mortality, myocardial infarction, or stroke) and major bleeding. RESULTS Anticoagulation with bivalirudin versus heparin did not meet superiority because it did not result in significantly lower rates of major bleeding at 48 h (6.9% vs. 9.0%; relative risk: 0.77; 95% confidence interval [CI]: 0.48 to 1.23; p = 0.27) or net adverse cardiovascular events at 30 days (14.4% vs. 16.1%; relative risk: 0.89; 95% CI: 0.64 to 1.24; risk difference: -1.72; 95% CI: -6.70 to 3.25; p = 0.50); regarding the latter, the prespecified noninferiority hypothesis was met (pnoninferiority < 0.01). Rates of major adverse cardiovascular events at 48 h were not significantly different (3.5% vs. 4.8%; relative risk: 0.73; 95% CI: 0.37 to 1.43; p = 0.35). At 48 h, the bivalirudin group had significantly fewer myocardial infarctions but more acute kidney injury events than the heparin group; at 30 days, these differences were no longer significant. CONCLUSIONS In this randomized trial of TAVR procedural pharmacotherapy, bivalirudin did not reduce rates of major bleeding at 48 h or net adverse cardiovascular events within 30 days compared with heparin. Although superiority was not shown, the noninferiority hypothesis was met with respect to the latter factor. Given the lower cost, heparin should remain the standard of care, and bivalirudin can be an alternative anticoagulant option in patients unable to receive heparin in TAVR. (International, Multi-center, Open-label, Randomized Controlled Trial in Patients Undergoing TAVR to Determine the Treatment Effect [Both Safety and Efficacy] of Using Bivalirudin Instead of UFH [BRAVO-2/3]; NCT01651780).
Resumo:
BACKGROUND Biomarkers of myocardial injury increase frequently during transcatheter aortic valve implantation (TAVI). The impact of postprocedural cardiac troponin (cTn) elevation on short-term outcomes remains controversial, and the association with long-term prognosis is unknown. METHODS AND RESULTS We evaluated 577 consecutive patients with severe aortic stenosis treated with TAVI between 2007 and 2012. Myocardial injury, defined according to the Valve Academic Research Consortium (VARC)-2 as post-TAVI cardiac troponin T (cTnT) >15× the upper limit of normal, occurred in 338 patients (58.1%). In multivariate analyses, myocardial injury was associated with higher risk of all-cause mortality at 30 days (adjusted hazard ratio [HR], 8.77; 95% CI, 2.07-37.12; P=0.003) and remained a significant predictor at 2 years (adjusted HR, 1.98; 95% CI, 1.36-2.88; P<0.001). Higher cTnT cutoffs did not add incremental predictive value compared with the VARC-2-defined cutoff. Whereas myocardial injury occurred more frequently in patients with versus without coronary artery disease (CAD), the relative impact of cTnT elevation on 2-year mortality did not differ between patients without CAD (adjusted HR, 2.59; 95% CI, 1.27-5.26; P=0.009) and those with CAD (adjusted HR, 1.71; 95% CI, 1.10-2.65; P=0.018; P for interaction=0.24). Mortality rates at 2 years were lowest in patients without CAD and no myocardial injury (11.6%) and highest in patients with complex CAD (SYNTAX score >22) and myocardial injury (41.1%). CONCLUSIONS VARC-2-defined cTnT elevation emerged as a strong, independent predictor of 30-day mortality and remained a modest, but significant, predictor throughout 2 years post-TAVI. The prognostic value of cTnT elevation was modified by the presence and complexity of underlying CAD with highest mortality risk observed in patients combining SYNTAX score >22 and evidence of myocardial injury.
Resumo:
Background: Heart failure (CHF) is the most frequent and prognostically severe symptom of aortic stenosis (AS), and the most common indication for surgery. The mainstay of treatment for AS is aortic valve replacement (AVR), and the main indication for an AVR is development of symptomatic disease. ACC/AHA guidelines define severe AS as an aortic valve area (AVA) ≤1cm², but there is little data correlating echocardiogram AVA with the onset of symptomatic CHF. We evaluated the risk of developing CHF with progressively decreasing echocardiographic AVA. We also compared echocardiographic AVA with Jet velocity (V2) and indexed AVA (AVAI) to assess the best predictor of development of symptomatic CHF.^ Methods and Results: This retrospective cohort study evaluated 518 patients with asymptomatic moderate or severe AS from a single community based cardiology practice. A total of 925 echocardiograms were performed over an 11-year period. Each echocardiogram was correlated with concurrent clinical assessments while the investigator was blinded to the echocardiogram severity of AS. The Cox Proportional hazards model was used to analyze the relationship between AVA and the development of CHF. The median age of patients at entry was 76.1 years, with 54% males. A total of 116 patients (21.8%) developed new onset CHF during follow-up. Compared to patients with AVA >1.0cm², patients with lower AVA had an exponentially increasing risk of developing CHF for each 0.2cm² decrement in AVA, becoming statistically significant only at an AVA less than 0.8 cm². Also, compared to V2 and AVAI, AVA added more information to assessing risk for development of CHF (p=0.041). ^ Conclusion: In patients with normal or mildly impaired LVEF, the risk of CHF rises exponentially with decreasing valve area and becomes statistically significant after AVA falls below 0.8cm². AVA is a better predictor of CHF when compared to V2 or AVAI.^
Resumo:
The Ross operation remains a controversially discussed procedure when performed in the full root technique because concern exists regarding late dilatation of the pulmonary autograft and regurgitation of the neo-aortic valve. In 2008, we published our short-term experience when using external reinforcement of the autograft, which was inserted into a prosthetic Dacron graft. This detail was thought to prevent neoaortic root dilatation. Since 2006, 22 adult patients have undergone a Ross procedure using this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 15), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 10 patients. Prior balloon valvuloplasty had been performed in seven patients. No early or late deaths occurred in this small series. One patient required aortic valve replacement early postoperatively, but freedom from late reoperation is 100% in the 21 remaining patients. Echocardiography confirmed the absence of more than trivial aortic insufficiency in 15 patients after a mean of 70 months (range, 14 to 108 months). No autograft dilatation was observed during follow-up and all patients are in New York Heart Association Class I. Autograft reinforcement is a simple and reproducible technical adjunct that may be especially useful in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement. The mid- to long-term results are encouraging because no late aortic root enlargement has been observed and the autograft valve is well functioning in all cases.
Resumo:
OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.
Resumo:
Heart valve disease occurs in adults as well as in pediatric population due to age-related changes, rheumatic fever, infection or congenital condition. Current treatment options are limited to mechanical heart valve (MHV) or bio-prosthetic heart valve (BHV) replacements. Lifelong anti-coagulant medication in case of MHV and calcification, durability in case of BHV are major setbacks for both treatments. Lack of somatic growth of these implants require multiple surgical interventions in case of pediatric patients. Advent of stem cell research and regenerative therapy propose an alternative and potential tissue engineered heart valves (TEHV) treatment approach to treat this life threatening condition. TEHV has the potential to promote tissue growth by replacing and regenerating a functional native valve. Hemodynamics play a crucial role in heart valve tissue formation and sustained performance. The focus of this study was to understand the role of physiological shear stress and flexure effects on de novo HV tissue formation as well as resulting gene and protein expression. A bioreactor system was used to generate physiological shear stress and cyclic flexure. Human bone marrow mesenchymal stem cell derived tissue constructs were exposed to native valve-like physiological condition. Responses of these tissue constructs to the valve-relevant stress states along with gene and protein expression were investigated after 22 days of tissue culture. We conclude that the combination of steady flow and cyclic flexure helps support engineered tissue formation by the co-existence of both OSS and appreciable shear stress magnitudes, and potentially augment valvular gene and protein expression when both parameters are in the physiological range.
Resumo:
La sténose aortique est la cardiopathie valvulaire la plus fréquente retrouvée chez les patients agés. Suite à l’apparition des symptômes, la survie des patients diminue de façon drastique en l’absence d’un remplacement valvulaire aortique. Cependant, une proportion considérable de ces patients n’est pas opérée en raison d’un risque chirurgical élevé, l’âge étant l’une des principales raisons de refus d’un remplacement valvulaire aortique chirurgical. Ce défaut dans la prise en charge des ces patients a favorisé le développement du remplacement valvulaire aortique par cathéter où implantation valvulaire aortique par cathèter (TAVR ou TAVI), qui a représenté une révolution dans le traitement de la sténose aortique. Cette intervention est actuellement un traitement de routine chez les patients à haut risque chirurgical atteints d’une sténose aortique, même si la chirurgie cardiaque n’est pas contre-indiquée. Ces dernières années ont vu un changement de profil des candidats potentiels vers une population à plus faible risque. Cependant, plusieurs préoccupations demeurent. L’une des plus importantes est la survenue des arythmies et de troubles de conduction, notamment le bloc de branche gauche et le bloc auriculo-ventriculaire, qui sont des complications fréquemment associées au TAVR. Malgré l’évolution de la technologie et le développement de nouveaux dispositifs réduisant le taux global de complications, aucune amélioration n’a pas été intégrée pour prévenir l’apparition de telles complications. De plus, l’utilisation de certains dispositifs de nouvelle génération semble être associée à un risque accru de troubles de conduction, et par conséquent, l’incidence de ces complications pourrait augmenter dans le futur. Cependant, L’impact et l’évolution de ces complications sont inconnus. Ce travail de recherche évalue l’incidence et l’évolution des troubles de conduction suite au TAVR et l’impact des blocs de branche gauche de novo et de l’implantation d’un pacemaker sur les résultats cliniques et échocardiographiques.
Resumo:
Heart valve disease occurs in adults as well as in pediatric population due to age-related changes, rheumatic fever, infection or congenital condition. Current treatment options are limited to mechanical heart valve (MHV) or bio-prosthetic heart valve (BHV) replacements. Lifelong anti-coagulant medication in case of MHV and calcification, durability in case of BHV are major setbacks for both treatments. Lack of somatic growth of these implants require multiple surgical interventions in case of pediatric patients. Advent of stem cell research and regenerative therapy propose an alternative and potential tissue engineered heart valves (TEHV) treatment approach to treat this life threatening condition. TEHV has the potential to promote tissue growth by replacing and regenerating a functional native valve. Hemodynamics play a crucial role in heart valve tissue formation and sustained performance. The focus of this study was to understand the role of physiological shear stress and flexure effects on de novo HV tissue formation as well as resulting gene and protein expression. A bioreactor system was used to generate physiological shear stress and cyclic flexure. Human bone marrow mesenchymal stem cell derived tissue constructs were exposed to native valve-like physiological condition. Responses of these tissue constructs to the valve-relevant stress states along with gene and protein expression were investigated after 22 days of tissue culture. We conclude that the combination of steady flow and cyclic flexure helps support engineered tissue formation by the co-existence of both OSS and appreciable shear stress magnitudes, and potentially augment valvular gene and protein expression when both parameters are in the physiological range. ^
Resumo:
Despite current recommendations, a high percentage of patients with severe symptomatic aortic stenosis are managed conservatively. The aim of this study was to study symptomatic patients undergoing conservative management from the IDEAS registry, describing their baseline clinical characteristics, mortality, and the causes according to the reason for conservative management. Consecutive patients with severe aortic stenosis diagnosed at 48 centers during January 2014 were included. Baseline clinical characteristics, echocardiographic data, Charlson index, and EuroSCORE-II were registered, including vital status and performance of valve intervention during one-year follow-up. For the purpose of this substudy we assessed symptomatic patients undergoing conservative management, including them in 5 groups according to the reason for performing conservative management [I: comorbidity/frailty (128, 43.8%); II: dementia 18 (6.2%); III: advanced age 34 (11.6%); IV: patients’ refusal 62 (21.2%); and V: other reasons 50 (17.1%)]. We included 292 patients aged 81.5 ± 9 years. Patients from group I had higher Charlson index (4 ± 2.3), higher EuroSCORE-II (7.5 ± 6), and a higher overall (42.2%) and non-cardiac mortality (16.4%) than the other groups. In contrast, patients from group III had fewer comorbidities, lower EuroSCORE-II (4 ± 2.5), and low overall (20.6%) and non-cardiac mortality (5.9%). Patients with severe symptomatic aortic stenosis managed conservatively have different baseline characteristics and clinical course according to the reason for performing conservative management. A prospective assessment of comorbidity and other geriatric syndromes might contribute to improve therapeutic strategy in this clinical setting.
Resumo:
The aim of this study is to describe the characteristics of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). This study was performed using the GAMES database, a national prospective registry of consecutive patients with IE in 26 Spanish hospitals. Of the 739 cases of IE diagnosed during the study, 1.3% were post-TAVI IE, and these 10 cases, contributed by five centres, represented 1.1% of the 952 TAVIs performed. Mean age was 80 years. All valves were implanted transfemorally. IE appeared a median of 139 days after implantation. The mean age-adjusted Charlson comorbidity index was 5.45. Chronic kidney disease was frequent (five patients), as were atrial fibrillation (five patients), chronic obstructive pulmonary disease (four patients), and ischaemic heart disease (four patients). Six patients presented aortic valve involvement, and four only mitral valve involvement; the latter group had a higher percentage of prosthetic mitral valves (0% vs. 50%). Vegetations were found in seven cases, and four presented embolism. One patient underwent surgery. Five patients died during follow-up: two of these patients died during the admission in which the valve was implanted. Conclusions: IE is a rare but severe complication after TAVI which affects about 1% of patients and entails a relatively high mortality rate. IE occurred during the first year in nine of the 10 patients.