987 resultados para Threshold Limit Values


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Iowa’s speed regulations are based on the same basic speed law that is used in all 50 states: “Any person driving a motor vehicle on a highway shall drive the same at a careful and prudent speed not greater than nor less than is reasonable and proper, having due regard to the traffic, surface, and width of the highway and of any other conditions then existing, and no person shall drive any vehicle upon a highway at a speed greater than will permit the person to bring it to a stop within the assured clear distance ahead, such driver having the right to assume, however, that all persons using said highway will observe the law.” Statutory limits are based on the concept that uniform categories of highways can be traveled safely at certain preset maximum speeds under ideal conditions. Whether the speed limit is posted or unposted, drivers should reduce their speed below these values in poor weather, heavy traffic, and under other potentially hazardous conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Iowa’s speed regulations are based on the same basic speed law that is used in all 50 states: “Any person driving a motor vehicle on a highway shall drive the same at a careful and prudent speed not greater than nor less than is reasonable and proper, having due regard to the traffic, surface, and width of the highway and of any other conditions then existing, and no person shall drive any vehicle upon a highway at a speed greater than will permit the person to bring it to a stop within the assured clear distance ahead, such driver having the right to assume, however, that all persons using said highway will observe the law.” Statutory limits are based on the concept that uniform categories of highways can be traveled safely at certain preset maximum speeds under ideal conditions. Whether the speed limit is posted or unposted, drivers should reduce their speed below these values in poor weather, heavy traffic, and under other potentially hazardous conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine dose thresholds, in term of CTDIvol, where subtle anatomical structures of pediatric CT images becomes no more detectable and compare them to the most recent Reference Dose Levels (DRL) proposed in the UK, Germany and Switzerland. Materials and methods: A GE LightSpeed-Ultra scanner (MSCT 8 slices) was used to perform chest and abdomen acquisitions on 8 patients (age range 2 to 16 years old) to provide a set of gold standard images. Dose reductions were then simulated by introducing image noise on raw data to provide simulated CT images with CTDIvol ranging from 2 to 22 mGy. All images were reviewed and scored independently by four experienced radiologists using the VGA methodology (Visual Grading Analysis) to determine the dose threshold where a significant loss of normal anatomy conspicuity appeared. Data were analyzed with ANOVA and Tukey HSD tests, a p >0.05 was considered to be significant. Results: No significant difference in VGA scoring appeared for CTDIvol leading to image noise levels lower than 10 and 25 HU for respectively abdominal and chest acquisitions. These data can thus be used to set the AEC (automatic exposure control) system of units having similar noise properties than the GE LightSpeed-Ultra used in this study. The present DRLs proposed for pediatric CT acquisitions are compatible with an excellent image quality level. Conclusion: The differences of DRL values proposed in Europe for pediatric acquisitions are marginal and assure a very good image quality level. The results of this study allow to further optimize the acquisition protocol by giving Noise Index value to set the AEC device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With over 68 thousand miles of gravel roads in Iowa and the importance of these roads within the farm-to-market transportation system, proper water management becomes critical for maintaining the integrity of the roadway materials. However, the build-up of water within the aggregate subbase can lead to frost boils and ultimately potholes forming at the road surface. The aggregate subbase and subgrade soils under these gravel roads are produced with material opportunistically chosen from local sources near the site and, many times, the compositions of these sublayers are far from ideal in terms of proper water drainage with the full effects of this shortcut not being fully understood. The primary objective of this project was to provide a physically-based model for evaluating the drainability of potential subbase and subgrade materials for gravel roads in Iowa. The Richards equation provided the appropriate framework to study the transient unsaturated flow that usually occurs through the subbase and subgrade of a gravel road. From which, we identified that the saturated hydraulic conductivity, Ks, was a key parameter driving the time to drain of subgrade soils found in Iowa, thus being a good proxy variable for accessing roadway drainability. Using Ks, derived from soil texture, we were able to identify potential problem areas in terms of roadway drainage . It was found that there is a threshold for Ks of 15 cm/day that determines if the roadway will drain efficiently, based on the requirement that the time to drain, Td, the surface roadway layer does not exceed a 2-hr limit. Two of the three highest abundant textures (loam and silty clay loam), which cover nearly 60% of the state of Iowa, were found to have average Td values greater than the 2-hr limit. With such a large percentage of the state at risk for the formation of boils due to the soil with relatively low saturated hydraulic conductivity values, it seems pertinent that we propose alternative design and/or maintenance practices to limit the expensive repair work in Iowa. The addition of drain tiles or French mattresses my help address drainage problems. However, before pursuing this recommendation, a comprehensive cost-benefit analysis is needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider a model for a damped spring-mass system that is a strongly damped wave equation with dynamic boundary conditions. In a previous paper we showed that for some values of the parameters of the model, the large time behaviour of the solutions is the same as for a classical spring-mass damper ODE. Here we use spectral analysis to show that for other values of the parameters, still of physical relevance and related to the effect of the spring inner viscosity, the limit behaviours are very different from that classical ODE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Perfusion-CT (PCT) processing involves deconvolution, a mathematical operation that computes the perfusion parameters from the PCT time density curves and an arterial curve. Delay-sensitive deconvolution does not correct for arrival delay of contrast, whereas delay-insensitive deconvolution does. The goal of this study was to compare delay-sensitive and delay-insensitive deconvolution PCT in terms of delineation of the ischemic core and penumbra. METHODS: We retrospectively identified 100 patients with acute ischemic stroke who underwent admission PCT and CT angiography (CTA), a follow-up vascular study to determine recanalization status, and a follow-up noncontrast head CT (NCT) or MRI to calculate final infarct volume. PCT datasets were processed twice, once using delay-sensitive deconvolution and once using delay-insensitive deconvolution. Regions of interest (ROIs) were drawn, and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) in these ROIs were recorded and compared. Volume and geographic distribution of ischemic core and penumbra using both deconvolution methods were also recorded and compared. RESULTS: MTT and CBF values are affected by the deconvolution method used (p < 0.05), while CBV values remain unchanged. Optimal thresholds to delineate ischemic core and penumbra are different for delay-sensitive (145 % MTT, CBV 2 ml × 100 g(-1) × min(-1)) and delay-insensitive deconvolution (135 % MTT, CBV 2 ml × 100 g(-1) × min(-1) for delay-insensitive deconvolution). When applying these different thresholds, however, the predicted ischemic core (p = 0.366) and penumbra (p = 0.405) were similar with both methods. CONCLUSION: Both delay-sensitive and delay-insensitive deconvolution methods are appropriate for PCT processing in acute ischemic stroke patients. The predicted ischemic core and penumbra are similar with both methods when using different sets of thresholds, specific for each deconvolution method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the effect of initial pH values of 4.5, 6.5 and 8.5 of the attractant (protein bait) Milhocina® and borax (sodium borate) in the field, on the capture of fruit flies in McPhail traps, using 1, 2, 4 and 8 traps per hectare, in order to estimate control thresholds in a Hamlin orange grove in the central region of the state of São Paulo. The most abundant fruit fly species was Ceratitis capitata, comprising almost 99% of the fruit flies captured, of which 80% were females. The largest captures of C. capitata were found in traps baited with Milhocina® and borax at pH 8.5. Captures per trap for the four densities were similar, indicating that the population can be estimated with one trap per hectare in areas with high populations. It was found positive relationships between captures of C. capitata and the number of Hamlin oranges damaged, 2 and 3 weeks after capture. It was obtained equations that correlate captures and damage levels which can be used to estimate control thresholds. The average loss caused in Hamlin orange fruits by C. capitata was 2.5 tons per hectare or 7.5% of production.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We develop an analytical approach to the susceptible-infected-susceptible epidemic model that allows us to unravel the true origin of the absence of an epidemic threshold in heterogeneous networks. We find that a delicate balance between the number of high degree nodes in the network and the topological distance between them dictates the existence or absence of such a threshold. In particular, small-world random networks with a degree distribution decaying slower than an exponential have a vanishing epidemic threshold in the thermodynamic limit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients' characteristics. METHODS: Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle. RESULTS: The mean attenuation was 46 HU (range, 17-84 HU) with mean SD 23 HU for the blood, and 39 HU (10-82 HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p < 0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%. CONCLUSIONS: Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient's characteristics, a better approach might be an adaptive threshold.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The high variability of CSF volumes partly explains the inconsistency of anesthetic effects, but may also be due to image analysis itself. In this study, criteria for threshold selection are anatomically defined. METHODS: T2 MR images (n = 7 cases) were analyzed using 3-dimentional software. Maximal-minimal thresholds were selected in standardized blocks of 50 slices of the dural sac ending caudally at the L5-S1 intervertebral space (caudal blocks) and middle L3 (rostral blocks). Maximal CSF thresholds: threshold value was increased until at least one voxel in a CSF area appeared unlabeled and decreased until that voxel was labeled again: this final threshold was selected. Minimal root thresholds: thresholds values that selected cauda equina root area but not adjacent gray voxels in the CSF-root interface were chosen. RESULTS: Significant differences were found between caudal and rostral thresholds. No significant differences were found between expert and nonexpert observers. Average max/min thresholds were around 1.30 but max/min CSF volumes were around 1.15. Great interindividual CSF volume variability was detected (max/min volumes 1.6-2.7). CONCLUSIONS: The estimation of a close range of CSF volumes which probably contains the real CSF volume value can be standardized and calculated prior to certain intrathecal procedures

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although healthy preterm infants frequently seem to be more attentive to visual stimuli and to fix on them longer than full-term infants, no difference in visual acuity has been reported compared to term infants. We evaluated the contrast sensitivity (CS) function of term (N = 5) and healthy preterm (N = 11) infants at 3 and 10 months of life using sweep-visual evoked potentials. Two spatial frequencies were studied: low (0.2 cycles per degrees, cpd) and medium (4.0 cpd). The mean contrast sensitivity (expressed in percentage of contrast) of the preterm infants at 3 months was 55.4 for the low spatial frequency (0.2 cpd) and 43.4 for the medium spatial frequency (4.0 cpd). At 10 months the low spatial CS was 52.7 and the medium spatial CS was 9.9. The results for the term infants at 3 months were 55.1 for the low spatial frequency and 34.5 for the medium spatial frequency. At 10 months the equivalent values were 54.3 and 14.4, respectively. No difference was found using the Mann-Whitney rank sum T-test between term and preterm infants for the low frequency at 3 or 10 months or for the medium spatial frequency at 3 or 10 months. The development of CS for the medium spatial frequency was equally fast for term and preterm infants. As also observed for visual acuity, CS was equivalent among term and preterm infants, suggesting that visual experience does not modify the development of the primary visual pathway. An earlier development of synapses in higher cortical visual areas of preterm infants could explain the better use of visual information observed behaviorally in these infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to characterize the heart rate (HR) patterns of healthy males using the autoregressive integrated moving average (ARIMA) model over a power range assumed to correspond to the anaerobic threshold (AT) during discontinuous dynamic exercise tests (DDET). Nine young (22.3 ± 1.57 years) and 9 middle-aged (MA) volunteers (43.2 ± 3.53 years) performed three DDET on a cycle ergometer. Protocol I: DDET in steps with progressive power increases of 10 W; protocol II: DDET using the same power values as protocol 1, but applied randomly; protocol III: continuous dynamic exercise protocol with ventilatory and metabolic measurements (10 W/min ramp power), for the measurement of ventilatory AT. HR was recorded and stored beat-to-beat during DDET, and analyzed using the ARIMA (protocols I and II). The DDET experiments showed that the median physical exercise workloads at which AT occurred were similar for protocols I and II, i.e., AT occurred between 75 W (116 bpm) and 85 W (116 bpm) for the young group and between 60 W (96 bpm) and 75 W (107 bpm) for group MA in protocols I and II, respectively; in two MA volunteers the ventilatory AT occurred at 90 W (108 bpm) and 95 W (111 bpm). This corresponded to the same power values of the positive trend in HR responses. The change in HR response using ARIMA models at submaximal dynamic exercise powers proved to be a promising approach for detecting AT in normal volunteers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Popular science has emphasized the risks of high sodium intake and many studies have confirmed that salt intake is closely related to hypertension. The present mini-review summarizes experiments about salt taste sensitivity and its relationship with blood pressure (BP) and other variables of clinical and familial relevance. Children and adolescents from control parents (N = 72) or with at least one essential hypertensive (EHT) parent (N = 51) were investigated. Maternal questionnaires on eating habits and vomiting episodes were collected. Offspring, anthropometric, BP, and salt taste sensitivity values were recorded and blood samples analyzed. Most mothers declared that they added "little salt" when cooking. Salt taste sensitivity was inversely correlated with systolic BP (SBP) in control youngsters (r = -0.33; P = 0.015). In the EHT group, SBP values were similar to control and a lower salt taste sensitivity threshold. Obese offspring of EHT parents showed higher SBP and C-reactive protein values but no differences in renin-angiotensin-aldosterone system activity. Salt taste sensitivity was correlated with SBP only in the non-obese EHT group (N = 41; r = 0.37; P = 0.02). Salt taste sensitivity was correlated with SBP in healthy, normotensive children and adolescents whose mothers reported significant vomiting during the first trimester (N = 18; r = -0.66; P < 0.005), but not in "non-vomiter offspring" (N = 54; r = -0.18; nonsignificant). There is evidence for a linkage between high blood pressure, salt intake and sensitivity, perinatal environment and obesity, with potential physiopathological implications in humans. This relationship has not been studied comprehensively using homogeneous methods and therefore more research is needed in this field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to determine the inter- and intra-examiner reliability of pain pressure threshold algometry at various points of the abdominal wall of healthy women. Twenty-one healthy women in menacme with a mean age of 28 ± 5.4 years (range: 19-39 years) were included. All volunteers had regular menstrual cycles (27-33 days) and were right-handed and, to the best of our knowledge, none were taking medications at the time of testing. Women with a diagnosis of depression, anxiety or other mood disturbances were excluded. Women with previous abdominal surgery, any pain condition or any evidence of inflammation, hypertension, smoking, alcoholism, or inflammatory disease were also excluded. Pain perception thresholds were assessed with a pressure algometer with digital traction and compression and a measuring capacity for 5 kg. All points were localized by palpation and marked with a felt-tipped pen and each individual was evaluated over a period of 2 days in two consecutive sessions, each session consisting of a set of 14 point measurements repeated twice by two examiners in random sequence. There was no statistically significant difference in the mean pain threshold obtained by the two examiners on 2 diferent days (examiner A: P = 1.00; examiner B: P = 0.75; Wilcoxon matched pairs test). There was excellent/good agreement between examiners for all days and all points. Our results have established baseline values to which future researchers will be able to refer. They show that pressure algometry is a reliable measure for pain perception in the abdominal wall of healthy women.