921 resultados para Three-phase line analysis
Resumo:
The objective of this report is to study distributed (decentralized) three phase optimal power flow (OPF) problem in unbalanced power distribution networks. A full three phase representation of the distribution networks is considered to account for the highly unbalance state of the distribution networks. All distribution network’s series/shunt components, and load types/combinations had been modeled on commercial version of General Algebraic Modeling System (GAMS), the high-level modeling system for mathematical programming and optimization. The OPF problem has been successfully implemented and solved in a centralized approach and distributed approach, where the objective is to minimize the active power losses in the entire system. The study was implemented on the IEEE-37 Node Test Feeder. A detailed discussion of all problem sides and aspects starting from the basics has been provided in this study. Full simulation results have been provided at the end of the report.
Resumo:
OBJECTIVE: To compare costs of function- and pain-centred inpatient treatment in patients with chronic low back pain over 3 years of follow-up. DESIGN: Cost analysis of a randomized controlled trial. PATIENTS: A total of 174 patients with chronic low back pain were randomized to function- or pain-centred inpatient treatment. METHODS: Data on direct and indirect costs were gathered by questionnaires sent to patients, health insurance providers, employers, and the Swiss Disability Insurance Company. RESULTS: There was a non-significant difference in total medical costs after 3 years' follow-up. Total costs were 77,305 Euros in the function-centred inpatient treatment group and 83,085 Euros in the pain-centred inpatient treatment group. Likewise, indirect costs after 3 years from lost work days were non-significantly lower in the function-centred in-patient treatment group (6354 Euros; 95% confidence interval -20,892, 8392) and direct medical costs were non-significantly higher in the function-centred inpatient treatment group (574 Euros; 95% confidence interval -862, 2011). CONCLUSION: The total costs of function-centred and pain-centred inpatient treatment were similar over the whole 3-year follow-up.
Resumo:
A three-phase transformer with flat conductor layers is proposed in this article. This arrangement is used for high current density transformers. Cost effectiveness in planar magnetic are related with the optimization in the number of layers in each winding. This fact takes more relevance for the medium and high power three-phase transformers where the number of parallels to achieve the required DCR is increased. The proposed method allows the use of off-the-shell core shapes that are used for single phase transformers. Cost impact is significant and design implications become more flexible. The proposed solution has been validated and compared using the conventional and the proposed methodologies to design a high power (20 kW) transformer.
Resumo:
A modified winding layout for three-phase transformers with PCB windings is proposed in this paper. This modified layout can be used in high current transformers with many PCB layers to simplify the fabrication process. One of the key factors that might increase the cost and complexity in the construction of planar transformers is the number of layers of each PCB winding. This issue becomes even more important in medium-high power three-phase transformers, where the number of PCB layers is higher. In addition to that, the proposed method allows the use of commercial core shapes that are commonly used to design single-phase transformers. This fact makes possible the reduction of cost and flexibility of the design solutions. The proposed solution has been validated and compared using the conventional and the proposed methodologies to design a high power (20 kW) transformer.
Resumo:
This paper presents an adaptive control for the auxiliary circuit, called ARCN (Auxiliary Resonant Commutating Network), used to achieve ZVS in full active bridge converters under a wide load range. Depending on the load conditions, the proposed control adapts the timing of the ARCN to minimize the losses. The principle of operation and implementation considerations are presented for a three phase full active bridge converter, proposing different methods to implement the control according to the specifications. The experimental results shown verify the proposed methodology.
Resumo:
Recently there has been an important increase in electric equipment, as well as, electric power demand in aircrafts applications. This prompts to the necessity of efficient, reliable, and low-weight converters, especially rectifiers from 115VAC to 270VDC because these voltages are used in power distribution. In order to obtain a high efficiency, in aircraft application where the derating in semiconductors is high, normally several semiconductors are used in parallel to decrease the conduction losses. However, this is in conflict with high reliability. To match both goals of high efficiency and reliability, this work proposes an interleaved multi-cell rectifier system, employing several converter cells in parallel instead of parallel-connected semiconductors. In this work a 10kW multi-cell isolated rectifier system has been designed where each cell is composed of a buck type rectifier and a full bridge DC-DC converter. The implemented system exhibits 91% of efficiency, high power density (10kW/10kg), low THD (2.5%), and n−1 fault tolerance which complies, with military aircraft standards.
Resumo:
In the present paper, 1-year PM10 and PM 2.5 data from roadside and urban background monitoring stations in Athens (Greece), Madrid (Spain) and London (UK) are analysed in relation to other air pollutants (NO,NO2,NOx,CO,O3 and SO2)and several meteorological parameters (wind velocity, temperature, relative humidity, precipitation, solar radiation and atmospheric pressure), in order to investigate the sources and factors affecting particulate pollution in large European cities. Principal component and regression analyses are therefore used to quantify the contribution of both combustion and non-combustion sources to the PM10 and PM 2.5 levels observed. The analysis reveals that the EU legislated PM 10 and PM2.5 limit values are frequently breached, forming a potential public health hazard in the areas studied. The seasonal variability patterns of particulates varies among cities and sites, with Athens and Madrid presenting higher PM10 concentrations during the warm period and suggesting the larger relative contribution of secondary and natural particles during hot and dry days. It is estimated that the contribution of non-combustion sources varies substantially among cities, sites and seasons and ranges between 38-67% and 40-62% in London, 26-50% and 20-62% in Athens, and 31-58% and 33-68% in Madrid, for both PM10 and PM 2.5. Higher contributions from non-combustion sources are found at urban background sites in all three cities, whereas in the traffic sites the seasonal differences are smaller. In addition, the non-combustion fraction of both particle metrics is higher during the warm season at all sites. On the whole, the analysis provides evidence of the substantial impact of non-combustion sources on local air quality in all three cities. While vehicular exhaust emissions carry a large part of the risk posed on human health by particle exposure, it is most likely that mitigation measures designed for their reduction will have a major effect only at traffic sites and additional measures will be necessary for the control of background levels. However, efforts in mitigation strategies should always focus on optimal health effects.
Resumo:
We study the timing and spectral properties of the low-magnetic field, transient magnetar SWIFT J1822.3−1606 as it approached quiescence. We coherently phase-connect the observations over a time-span of ∼500 d since the discovery of SWIFT J1822.3−1606 following the Swift-Burst Alert Telescope (BAT) trigger on 2011 July 14, and carried out a detailed pulse phase spectroscopy along the outburst decay. We follow the spectral evolution of different pulse phase intervals and find a phase and energy-variable spectral feature, which we interpret as proton cyclotron resonant scattering of soft photon from currents circulating in a strong (≳1014 G) small-scale component of the magnetic field near the neutron star surface, superimposed to the much weaker (∼3 × 1013 G) magnetic field. We discuss also the implications of the pulse-resolved spectral analysis for the emission regions on the surface of the cooling magnetar.
Resumo:
Unclassified Physics Distribution.
Resumo:
Cover title.
Resumo:
"February 1970."
Resumo:
Includes index.
Resumo:
Includes index.
Resumo:
"27 March 1987."