1000 resultados para Testes de Função Cardíaca


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Chronic stress is associated with cardiac remodeling; however the mechanisms have yet to be clarified. Objective: The purpose of this study was test the hypothesis that chronic stress promotes cardiac dysfunction associated to L-type calcium Ca2+ channel activity depression. Methods: Thirty-day-old male Wistar rats (70 - 100 g) were distributed into two groups: control (C) and chronic stress (St). The stress was consistently maintained at immobilization during 15 weeks, 5 times per week, 1h per day. The cardiac function was evaluated by left ventricular performance through echocardiography and by ventricular isolated papillary muscle. The myocardial papillary muscle activity was assessed at baseline conditions and with inotropic maneuvers such as: post-rest contraction and increases in extracellular Ca2+ concentration, in presence or absence of specific blockers L-type calcium channels. Results: The stress was characterized for adrenal glands hypertrophy, increase of systemic corticosterone level and arterial hypertension. The chronic stress provided left ventricular hypertrophy. The left ventricular and baseline myocardial function did not change with chronic stress. However, it improved the response of the papillary muscle in relation to positive inotropic stimulation. This function improvement was not associated with the L-type Ca2+ channel. Conclusion: Chronic stress produced cardiac hypertrophy; however, in the study of papillary muscle, the positive inotropic maneuvers potentiated cardiac function in stressed rats, without involvement of L-type Ca2+ channel. Thus, the responsible mechanisms remain unclear with respect to Ca2+ influx alterations. (Arq Bras Cardiol 2012;99(4):907-914)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Linfadenomegalias mediastinais secundárias a hipervolemia são achados tomográficos subdiagnosticados. Descrevemos neste paciente com função cardíaca normal, achados de congestão pulmonar associados a alargamento dos linfonodos mediastinais. A síndrome nefrótica causando hipoalbuminemia, baixa pressão oncótica plasmática e aumento da pressão transcapilar foi a causa provável dos achados radiológicos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

FUNDAMENTO: A hipertensão pulmonar é associada ao pior prognóstico no pós-transplante cardíaco. O teste de reatividade pulmonar com Nitroprussiato de Sódio (NPS) está associado a elevados índices de hipotensão arterial sistêmica, disfunção ventricular do enxerto transplantado e elevadas taxas de desqualificação para o transplante. OBJETIVO: Neste estudo, objetivou-se comparar os efeitos do Sildenafil (SIL) e NPS sobre variáveis hemodinâmicas, neuro-hormonais e ecocardiográficas durante teste de reatividade pulmonar. MÉTODOS: Os pacientes foram submetidos, simultaneamente, ao cateterismo cardíaco direito, ao ecocardiograma e à dosagem de BNP e gasometria venosa, antes e após administração de NPS (1 - 2 µg/Kg/min) ou SIL (100 mg, dose única). RESULTADOS: Ambos reduziram a hipertensão pulmonar, porém o nitrato promoveu hipotensão sistêmica significativa (Pressão Arterial Média - PAM: 85,2 vs. 69,8 mmHg, p < 0,001). Ambos reduziram as dimensões cardíacas e melhoraram a função cardíaca esquerda (NPS: 23,5 vs. 24,8 %, p = 0,02; SIL: 23,8 vs. 26 %, p < 0,001) e direita (SIL: 6,57 ± 2,08 vs. 8,11 ± 1,81 cm/s, p = 0,002; NPS: 6,64 ± 1,51 vs. 7,72 ± 1,44 cm/s, p = 0,003), medidas pela fração de ejeção ventricular esquerda e Doppler tecidual, respectivamente. O SIL, ao contrário do NPS, apresentou melhora no índice de saturação venosa de oxigênio, medido pela gasometria venosa. CONCLUSÃO: Sildenafil e NPS são vasodilatadores que reduzem, de forma significativa, a hipertensão pulmonar e a geometria cardíaca, além de melhorar a função biventricular. O NPS, ao contrário do SIL, esteve associado a hipotensão arterial sistêmica e piora da saturação venosa de oxigênio.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Investigar o significado de marcadores de imunidade celular e de componentes elásticos/colágeno da matriz extracelular em estruturas granulomatosas em biópsias de pacientes com sarcoidose pulmonar ou extrapulmonar. MÉTODOS: Determinações qualitativas e quantitativas de células inflamatórias, de fibras de colágeno e de fibras elásticas em estruturas granulomatosas em biópsias cirúrgicas de 40 pacientes com sarcoidose pulmonar e extrapulmonar foram realizadas por histomorfometria, imuno-histoquímica, e técnicas de coloração com picrosirius e resorcina-fucsina de Weigert. RESULTADOS: A densidade de linfócitos, macrófagos e neutrófilos nas biópsias extrapulmonares foi significativamente maior do que nas biópsias pulmonares. Os granulomas pulmonares apresentaram uma quantidade significativamente maior de fibras de colágeno e menor densidade de fibras elásticas que os granulomas extrapulmonares. A quantidade de macrófagos nos granulomas pulmonares correlacionou-se com CVF (p < 0,05), ao passo que as quantidades de linfócitos CD3+, CD4+ e CD8+ correlacionaram-se com a relação VEF1/CVF e com CV. Houve correlações negativas entre CPT e contagem de células CD1a+ (p < 0,05) e entre DLCO e densidade de fibras colágenas/elásticas (r = -0,90; p = 0,04). CONCLUSÕES: A imunofenotipagem e o remodelamento apresentaram características diferentes nas biópsias dos pacientes com sarcoidose pulmonar e extrapulmonar. Essas diferenças correlacionaram-se com os dados clínicos e espirométricos dos pacientes, sugerindo que há duas vias envolvidas no mecanismo de depuração de antígenos, que foi mais eficaz nos pulmões e linfonodos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Apesar da utilização da ventilação mecânica protetora como estratégia para o tratamento da síndrome do desconforto respiratório agudo, ao menos um quarto dos pacientes com essa síndrome ainda apresentam redução na função pulmonar após 6 meses de seguimento. Não se sabe se esta redução está relacionada com a gravidade da síndrome ou associada com a forma de ventilar o paciente. Nosso objetivo neste trabalho foi avaliar a associação entre alterações funcionais e estruturais do pulmão com parâmetros de gravidade clínica e de ventilação mecânica. Foi realizada uma análise secundária dos dados obtidos em estudo randomizado e controlado que incluiu pacientes com síndrome do desconforto respiratório agudo moderada/grave, internados em seis unidades de terapia intensiva em um hospital terciário da cidade de São Paulo. Foram analisados dados de pacientes que tinham ao menos um teste de função pulmonar no seguimento. O teste funcional incluiu a medida da capacidade vital forçada, volumes pulmonares e a capacidade de difusão do monóxido de carbono após 1, 2 e 6 meses de seguimento. Foram considerados variáveis independentes o volume corrente, a pressão de distensão e a pressão positiva ao final da expiração (todos medidos após 24 horas da randomização) e um sistema de classificação de prognóstico (APACHE II), a relação PaO2/FIO2 e a complacência respiratória estática (todos medidos antes da randomização). Também foi realizada tomografia de alta resolução do tórax juntamente com os testes de função pulmonar, e posterior análise quantitativa das imagens. Na avaliação de 6 meses também foi realizado teste de caminhada de 6 minutos e um questionário de qualidade de vida (SF-36). Um total de 21 pacientes realizaram o teste de função pulmonar após 1 mês e 15 pacientes realizaram após 2 e 6 meses de seguimento. A capacidade vital forçada foi relacionada inversamente com a pressão de distensão na avaliação de 1, 2 e 6 meses (p < 0,01). A capacidade de difusão do monóxido de carbono relacionou-se inversamente com a pressão de distensão e com o APACHE II (ambos p < 0,01) na avaliação de 1 e 2 meses. Após 6 meses de seguimento, houve correlação inversa entre a pressão de distensão e a capacidade vital forçada independente do volume corrente, da pressão de platô e da complacência estática respiratória após ajustes (R2 = 0,51, p = 0,02). A pressão de distensão também se relacionou com o volume pulmonar total, a densidade pulmonar media e a porcentagem de volume pulmonar não aerado ou pobremente aerado medidos através da análise quantitativa da tomografia computadorizada de tórax realizada na avaliação de 6 meses. Também foi observada relação entre a qualidade de vida após 6 meses de seguimento e a pressão de distensão considerando o domínio estado geral de saúde. Nós concluímos que mesmo em pacientes ventilados com reduzido volume corrente e pressão de platô limitada, maiores valores de pressão de distensão relacionaram-se com menores valores de função pulmonar no seguimento de longo prazo

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cryptography is the main form to obtain security in any network. Even in networks with great energy consumption restrictions, processing and memory limitations, as the Wireless Sensors Networks (WSN), this is no different. Aiming to improve the cryptography performance, security and the lifetime of these networks, we propose a new cryptographic algorithm developed through the Genetic Programming (GP) techniques. For the development of the cryptographic algorithm’s fitness criteria, established by the genetic GP, nine new cryptographic algorithms were tested: AES, Blowfish, DES, RC6, Skipjack, Twofish, T-DES, XTEA and XXTEA. Starting from these tests, fitness functions was build taking into account the execution time, occupied memory space, maximum deviation, irregular deviation and correlation coefficient. After obtaining the genetic GP, the CRYSEED and CRYSEED2 was created, algorithms for the 8-bits devices, optimized for WSNs, i.e., with low complexity, few memory consumption and good security for sensing and instrumentation applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cryptography is the main form to obtain security in any network. Even in networks with great energy consumption restrictions, processing and memory limitations, as the Wireless Sensors Networks (WSN), this is no different. Aiming to improve the cryptography performance, security and the lifetime of these networks, we propose a new cryptographic algorithm developed through the Genetic Programming (GP) techniques. For the development of the cryptographic algorithm’s fitness criteria, established by the genetic GP, nine new cryptographic algorithms were tested: AES, Blowfish, DES, RC6, Skipjack, Twofish, T-DES, XTEA and XXTEA. Starting from these tests, fitness functions was build taking into account the execution time, occupied memory space, maximum deviation, irregular deviation and correlation coefficient. After obtaining the genetic GP, the CRYSEED and CRYSEED2 was created, algorithms for the 8-bits devices, optimized for WSNs, i.e., with low complexity, few memory consumption and good security for sensing and instrumentation applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to verify the association between some mobility items of the International Classification Functionality (ICF), with the evaluations Gross Motor Function Measure (GMFM-88), 1-minute walk test (1MWT) and if the motor impairment influences the quality of life in children with Cerebral Palsy (PC), by using the Paediatric Quality of Life Inventory (PedsQL 4.0 versions for children and parents). The study included 22 children with cerebral palsy spastic, classified in levels I, II, and III on the Gross Motor Function Classification System (GMFCS), with age group of 9.9 years old. Among those who have participated, seven of them were level I, eight of them were level II and seven of them were level III. All of the children and teenagers were rated by using check list ICF (mobility item), GMFM-88, 1-minute walk test and PedsQL 4.0 questionnaires for children and parents. It was observed a strong correlation between GMFM-88 with check list ICF (mobility item), but moderate correlation between GMFM-88 and 1-minute walk test (1MWT). It was also moderate the correlation between the walking test and the check list ICF (mobility item). The correlation between PedsQl 4.0 questionnaires for children and parents was weak, as well as the correlation of both with GMFM, ICF (mobility item) and the walking test. The lack of interrelation between physical function tests and quality of life, indicates that, regardless of the severity of the motor impairment and the difficulty with mobility, children and teenagers suffering of PC spastic, functional level I, II and III GMFCS and their parents have a varied opinion regarding the perception of well being and life satisfaction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A síndrome Takotsubo (STT) é uma forma adquirida e transitória de disfunção sistólica, cuja apresentação clínica e eletrocardiográfica mimetiza um enfarte agudo do miocárdio. A STT é também conhecida como miocardiopatia de stress, síndrome do «coração partido», balonamento apical, insuficiência cardíaca aguda reversível, miocárdio «atordoado» (forma neurogénica) ou miocardiopatia aguda das catecolaminas. Os autores descrevem uma apresentação rara de STT após procedimento anestésico. Adolescente de 14 anos, sexo feminino, com antecedentes pessoais de enxaqueca hemiplé- gica e quisto pineal, submetida a ressonância magnética (RM) cranioencefálica de controlo. Durante a indução anestésica com propofol verificou-se bradicardia, revertida com atropina, seguida de taquidisritmia ventricular, revertida com lidocaína e murro pré-cordial. Nas primeiras horas de internamento evoluiu para edema pulmonar associado a insuficiência respiratória global por disfunção ventricular esquerda aguda. O ecocardiograma transtorácico mostrou dilatação do ventrículo esquerdo com hipocinesia global e fração de ejeção reduzida (< 30%). O eletrocardiograma revelou taquicardia sinusal persistente e alterações inespecíficas do segmento ST. Os biomarcadores cardíacos encontravam-se elevados (troponina 2,42 ng/ml, proBNP 8248 pg/ml). Foi medicada com diuréticos, IECA, digitálico e dopamina, com melhoria clínica, bioquímica e ecocardiográfica ao quarto dia. Os ecocardiogramas subsequentes mostraram normalização da função ventricular. A doente teve alta medicada com carvedilol, que suspendeu após normalização da função cardíaca e RM cardíaca não ter revelado alterações. Estão descritos poucos casos de STT em idade pediátrica. Alguns são desencadeados por patologia aguda do sistema nervoso central, mas nem todos cumprem os critérios de diagnóstico clássicos. Neste caso, o procedimento anestésico poderá ter desencadeado a STT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objeto Parada Cardiorrespiratória inicia a abordagem destacando que As doenças cardiovasculares estão entre os principais motivos de óbito em todo o mundo. Estima-se que, por ano, inesperadamente, mais de dois milhões de habitantes morram por essas causas. Fala que o atendimento de pessoas com parada cardiorrespiratória e as manobras utilizadas para reanimação são estudada desde os tempos antigos, mas somente a partir do século XVIII, tiveram início as observações científicas. Elenca a evolução histórica falando que nos anos 60 deu-se inicio a sistematização das manobras de reanimação, nos anos 70 foram criados os cursos sobre suporte avançado de vida em cardiologia, em 1992 foi criada a Aliança Internacional dos Comitês de Ressuscitação e em 2005, depois de uma revisão dos procedimentos, foi divulgado orientações gerais para a RCP. Na sequencia, o objeto conceitua PCR, como sendo uma incapacidade do coração de garantir um débito eficaz, com uma interrupção imediata da circulação sanguínea e uma supressão do aporte de sangue oxigenado a todos os órgãos, e consequente perda da função cardíaca, respiratória e cerebral; acompanhada de uma parada respiratória e perda da consciência. Elenca os sintomas que precedem a uma PCR e alerta que o atraso no diagnóstico, o procedimento tardio e a falta de conhecimento do protocolo são os principais motivos de insucessos em situações de PCR. Para finalizar, o objeto destaca que a PCR pode levar a morte súbta, conceituando e classificando-a. Unidade 2 do módulo 15 que compõe o Curso de Especialização em Saúde da Família.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mulher, 60 anos, branca, vem apresentando dispneia progressiva há cerca de dois anos. Nesse período vem apresentando episódios esporádicos de chiado no peito e tosse produtiva na maioria dos dias. Nas últimas 02 semanas notou um aumento do escarro e piora da dispneia, sendo que há uma semana iniciou com quadro de febre baixa e escarro purulento. Em virtude do quadro procurou o pronto socorro onde realizou um hemograma e um RX de tórax. Foi medicada com amoxacilina 500mg três vezes ao dia e orientada a procurar uma UBS. Após cinco dias vem a UBS com os exames. Refere diminuição do escarro e da febre, porém, persiste com dispneia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

deo demonstrativo de método de escolha para avaliação da função pulmonar com utilização de espirômetro com manobra de expiração forçada

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

deo demonstrativo de de teste cutâneo para diagnóstico diferencial de sibilância na infância

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aula 6 do Curso Capacitação a Distância em Asma na Infância e Adolescência. Bases conceituais e regimes terapêuticos indicados para o tratamento de manutenção da asma, ou seja, aquele que é dirigido á forma persistente da enfermidade e que visa ao controle e mesmo a normalização, tanto do quadro clínico dos parâmetros avaliados nos testes de função pulmonar.