884 resultados para Temperature - Physiological effect
Resumo:
This chapter reviews studies on the effects of mycotoxins on embryonic and fetal development, especially those toxins that are global food and feed contaminants. The toxins discussed include aflatoxin produced by Aspergillus flavus and A. parasiticus, ochratoxin which is produced by Aspergillus species particularly A. ochraceus as well as Penicillium verrucosum, ergot alkaloids produced by Claviceps spp., and the Fusarium toxins (fumonisins, deoxynivalenol [vomitoxin], and zearalenone). These toxins have been shown to be teratogenic and/or embryotoxic in different animal bioassays. The implications of toxicity on embryogenesis, and the progress of research on these mycotoxins, are also examined.
Resumo:
The behavior of a temperature self-compensating, fiber, long-period grating (LPG) device is studied. This device consists of a single 325-µm-period LPG recorded across two sections of a single-mode B-Ge-codoped fiber—one section bare and the other coated with a 1-µm thickness of Ag. This structure generates two attenuation bands associated with the eighth and ninth cladding modes, which are spectrally close together (~60 nm). The attenuation band associated with the Ag-coated section is unaffected by changes in the refractive index of the surrounding medium and can be used to compensate for the temperature of the bare-fiber section. The sensor has a resolution of ±1.0 × 10-3 for the refractive index and ±0.3 °C for the temperature. The effect of bending on the spectral characteristics of the two attenuation bands was found to be nonlinear, with the Ag-coated LPG having the greater sensitivity.
Resumo:
The effect of brittle coating precracking on the fatigue behavior of a high-activity aluminide-coated single-crystal nickel-base superalloy has been studied using hollow cylindrical specimens at test temperatures of 600 °C, 800 °C, and 1000 °C. Three types of precrack were studied: narrow precracks formed at room temperature, wide precracks formed at room temperature, and narrow precracks formed at elevated temperature. The effect of precracking on fatigue life at 600 °C was found to depend strongly on the type of precrack. No failure was observed for specimens with narrow room-temperature precracks because of crack arrest via an oxidation-induced crack closure mechanism, while the behavior of wide precracks and precracks formed at elevated temperature mirrored the non-precracked behavior. Crack retardation also occurred for narrow room-temperature precracks tested at 800 °C - in this case, fatigue cracks leading to failure initiated in a layer of recrystallized grains on the inside surface of the specimen. A significant reduction in fatigue life at 800 °C relative to non-precracked specimens was observed for wide precracks and elevated temperature precracks. The presence of precracks bypassed the initiation and growth of coating fatigue cracks necessary for failure in non-precracked material. No effect of precracking was observed at 1000 °C.
Resumo:
The behavior of a temperature self-compensating, fiber, long-period grating (LPG) device is studied. This device consists of a single 325-µm-period LPG recorded across two sections of a single-mode B-Ge-codoped fiber—one section bare and the other coated with a 1-µm thickness of Ag. This structure generates two attenuation bands associated with the eighth and ninth cladding modes, which are spectrally close together (~60 nm). The attenuation band associated with the Ag-coated section is unaffected by changes in the refractive index of the surrounding medium and can be used to compensate for the temperature of the bare-fiber section. The sensor has a resolution of ±1.0 × 10-3 for the refractive index and ±0.3 °C for the temperature. The effect of bending on the spectral characteristics of the two attenuation bands was found to be nonlinear, with the Ag-coated LPG having the greater sensitivity.
Resumo:
This study attempted to determine if an excessive amount of 1,1,1 - Trichloroethane was released into the air, the acute effects of exposure and the cause(s) of excessive use. The types of degreasing equipments which were tested in this study are straight vapor and the vapor spray machines. The instruments utilized to obtain the data for this study are Gastech Haline Detector, Organic Vapor Monitor Badge and Personal Sampling Pump. Readings were taken on three different tanks. The data accumulated by this study were obtained during actual cleaning operation. During testing, increased exposure was detected due to exceeding the rate of removal, downward drafts were blowing right over the top of a degreaser and, in some cases, poor general ventilation caused solvent vapor to be blown out of the tank and into the workers' breathing zone, affecting excessive vapor drag out and solvent loss. The results show that, since the characteristics of solvent 1,1,1 - Trichloroethane are well suited to vapor degreasing requirements, by using proper procedures and maintenance, 1,1,1 - Trichloroethane emission during vapor degreasing can be controlled at levels well below the industrial hygiene standard established by OSHA for safe and healthful conditions.