981 resultados para TRANSARTICULAR SCREW FIXATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scolex of the bothriocephalidean cestode Clestobothrium crassiceps was studied by means of scanning electron microscopy (SEM). The comparative results of various fixation procedures and techniques are presented. The scolex of C. crassiceps is oval to globular and exhibits two deep bothria which appear in the form of two lobes separated by a longitudinal groove. At the apex of the scolex, resembling a beret, an apical disc is present (oval, flattened and with a sinuous edge). Our results are compared with those previously reported in other species of Clestobothrium. This study represents the first report which highlights the presence of an apical disc in the scolex of C. crassiceps. It describes the effects of different procedures applied to our material during preparation and a comparative analysis results obtained using these various methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ankle fractures in adults are usually managed by open reduction internal fixation. In elderly patients the surgical dilemma relates to bone quality. Osteoporosis is the enemy of internal fixation, and secure purchase of screws in osteopenic bone may be difficult to achieve. Insufficient screw purchase may lead to loss of reduction, wound breakdown, and infection. Postoperative management after osteosynthesis usually requires an extended period of restricted weight bearing. However, this is not feasible in older patients as a result of their lack of strength in the upper extremities and frequent comorbidities. Therefore, augmen- ted methods of internal fixation and specific surgical techniques have been developed using metal and bone cement. This permits this fragile population to begin early full weight bearing in a removable brace.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to assess the results of labyrinthine fenestration for fixed stapes in chronic ear disease. Using a prospective database, pre- and postoperative audiometric data from patients undergoing labyrinthine fenestration for fixation of the stapes in chronic ear disease others than otosclerosis between 2002 and 2012 were evaluated. Twenty-three labyrinthine fenestrations in chronic ear disease were performed (17 malleo-stapedotomies, 4 incus-stapedotomies, 1 neo-malleus-stapedotomy, 1 TORP-stapedotomy). Overall, the mean short-term (2 months) and long-term (42 months) postoperative air-bone gap (0.5-3 kHz) were 17.5 and 16.5 dB, respectively; long-term air-bone gap of <20 dB was obtained in 73 % of patients. There was no significant difference in air-bone gap closure between tympanosclerotic and post inflammatory osteogenic fixation of the stapes (p = 0.267). Hearing benefit success using the 'Belfast rule of the thumb' was achieved in 48 %. Normal bilateral hearing was achieved in 17 % and bilateral symmetric hearing impairment in 26 %. Only in 4 %, bone conduction worsened by more than 5 dB. Labyrinthine fenestration is an option in selected cases of stapes fixation in chronic ear disease and provides hearing gain without significant risk for sensorineural hearing loss. In those already selected cases, hearing benefit success 'Belfast rule of the thumb' is achieved only in half of the cases. This and the possible alternatives, should therefore be discussed preoperatively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranial bone reconstructions are necessary for correcting large skull bone defects due to trauma, tumors, infections and craniotomies. Traditional synthetic implant materials include solid or mesh titanium, various plastics and ceramics. Recently, biostable glass-fiber reinforced composites (FRC), which are based on bifunctional methacrylate resin, were introduced as novel implant solution. FRCs were originally developed and clinically used in dental applications. As a result of further in vitro and in vivo testing, these composites were also approved for clinical use in cranial surgery. To date, reconstructions of large bone defects were performed in 35 patients. This thesis is dedicated to the development of a novel FRC-based implant for cranial reconstructions. The proposed multi-component implant consists of three main parts: (i) porous FRC structure; (ii) bioactive glass granules embedded between FRC layers and (iii) a silver-polysaccharide nanocomposite coating. The porosity of the FRC structure should allow bone ingrowth. Bioactive glass as an osteopromotive material is expected to stimulate the formation of new bone. The polysaccharide coating is expected to prevent bacterial colonization of the implant. The FRC implants developed in this study are based on the porous network of randomly-oriented E-glass fibers bound together by non-resorbable photopolymerizable methacrylate resin. These structures had a total porosity of 10–70 volume %, of which > 70% were open pores. The pore sizes > 100 μm were in the biologically-relevant range (50-400 μm), which is essential for vascularization and bone ingrowth. Bone ingrowth into these structures was simulated by imbedding of porous FRC specimens in gypsum. Results of push-out tests indicated the increase in the shear strength and fracture toughness of the interface with the increase in the total porosity of FRC specimens. The osteopromotive effect of bioactive glass is based on its dissolution in the physiological environment. Here, calcium and phosphate ions, released from the glass, precipitated on the glass surface and its proximity (the FRC) and formed bone-like apatite. The biomineralization of the FRC structure, due to the bioactive glass reactions, was studied in Simulated Body Fluid (SBF) in static and dynamic conditions. An antimicrobial, non-cytotoxic polysaccharide coating, containing silver nanoparticles, was obtained through strong electrostatic interactions with the surface of FRC. In in vitro conditions the lactose-modified chitosan (chitlac) coating showed no signs of degradation within seven days of exposure to lysozyme or one day to hydrogen peroxide (H2O2). The antimicrobial efficacy of the coating was tested against Staphylococcus aureus and Pseudomonas aeruginosa. The contact-active coating had an excellent short time antimicrobial effect. The coating neither affected the initial adhesion of microorganisms to the implant surface nor the biofilm formation after 24 h and 72 h of incubation. Silver ions released to the aqueous environment led to a reduction of bacterial growth in the culture medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plants were regenerated from leaf-derived callus culture of Stylosanthes scabra, a polyploid legume tolerant to drought and adapted to acid soils. A total of 168 regenerants were planted out in Leonard jars in a complete randomized design. Nitrogen fixation and vegetative growth were indirectly evaluated by shoot dry weight, root dry weight, shoot N content and acetylene reduction activity. The results showed higher variation in the regenerants than in controls not submitted to tissue culture. Significant differences were found for all nitrogen fixation related-traits

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NifA protein activates transcription of nitrogen fixation operons by the alternative sigma54 holoenzyme form of RNA polymerase. This protein binds to a well-defined upstream activator sequence (UAS) located at the -200/-100 position of nif promoters with the consensus motif TGT-N10-ACA. NifA of Azospirillum brasilense was purified in the form of a glutathione-S-transferase (GST)-NifA fusion protein and proteolytic release of GST yielded inactive and partially soluble NifA. However, the purified NifA was able to induce the production of specific anti-A. brasilense NifA-antiserum that recognized NifA from A. brasilense but not from K. pneumoniae. Both GST-NifA and NifA expressed from the E. coli tac promoter are able to activate transcription from the nifHDK promoter but only in an A. brasilense background. In order to investigate the mechanism that regulates NifA binding capacity we have used E. coli total protein extracts expressing A. brasilense nifA in mobility shift assays. DNA fragments carrying the two overlapping, wild-type or mutated UAS motifs present in the nifH promoter region revealed a retarded band of related size. These data show that the binding activity present in the C-terminal domain of A. brasilense NifA protein is still functional even in the presence of oxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays the energy efficiency has become one of the most concerned topics. Compressors are the equipment, which is very common in industry. Moreover, they tend to operate during long cycles and therefore even small decrease in power consumption can significantly reduce electricity costs during the year. And therefore it is important to investigate ways of increasing the energy efficiency of the compressors. In the thesis rotary screw compressor alongside with different control approaches is described. Simulation models for various control types of rotary screw compressor are developed. Analysis of laboratory equipment is conducted and results are compared with simulation. Suggestions of the real laboratory equipment improvement are given.