801 resultados para Strain-rate dependent behavior
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização - Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de Especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
INTRODUCTION: Adults with repaired tetralogy of Fallot (TOF) may be at risk for progressive right ventricular (RV) dilatation and dysfunction, which is commonly associated with arrhythmic events. In frequently volume-overloaded patients with congenital heart disease, tissue Doppler imaging (TDI) is particularly useful for assessing RV function. However, it is not known whether RV TDI can predict outcome in this population. OBJECTIVE: To evaluate whether RV TDI parameters are associated with supraventricular arrhythmic events in adults with repaired TOF. METHODS: We studied 40 consecutive patients with repaired TOF (mean age 35 +/- 11 years, 62% male) referred for routine echocardiographic exam between 2007 and 2008. The following echocardiographic measurements were obtained: left ventricular (LV) ejection fraction, LV end-systolic volume, LV end-diastolic volume, RV fractional area change, RV end-systolic area, RV end-diastolic area, left and right atrial volumes, mitral E and A velocities, RV myocardial performance index (Tei index), tricuspid annular plane systolic excursion (TAPSE), myocardial isovolumic acceleration (IVA), pulmonary regurgitation color flow area, TDI basal lateral, septal and RV lateral peak diastolic and systolic annular velocities (E' 1, A' 1, S' 1, E' s, A' s, S' s, E' rv, A' rv, S' rv), strain, strain rate and tissue tracking of the same segments. QRS duration on resting ECG, total duration of Bruce treadmill exercise stress test and presence of exercise-induced arrhythmias were also analyzed. The patients were subsequently divided into two groups: Group 1--12 patients with previous documented supraventricular arrhythmias (atrial tachycardia, fibrillation or flutter) and Group 2 (control group)--28 patients with no previous arrhythmic events. Univariate and multivariate analysis was used to assess the statistical association between the studied parameters and arrhythmic events. RESULTS: Patients with previous events were older (41 +/- 14 vs. 31 +/- 6 years, p = 0.005), had wider QRS (173 +/- 20 vs. 140 +/- 32 ms, p = 0.01) and lower maximum heart rate on treadmill stress testing (69 +/- 35 vs. 92 +/- 9%, p = 0.03). All patients were in NYHA class I or II. Clinical characteristics including age at corrective surgery, previous palliative surgery and residual defects did not differ significantly between the two groups. Left and right cardiac chamber dimensions and ventricular and valvular function as evaluated by conventional Doppler parameters were also not significantly different. Right ventricular strain and strain rate were similar between the groups. However, right ventricular myocardial TDI systolic (Sa: 5.4+2 vs. 8.5 +/- 3, p = 0.004) and diastolic indices and velocities (Ea, Aa, septal E/Ea, and RV free wall tissue tracking) were significantly reduced in patients with arrhythmias compared to the control group. Multivariate linear regression analysis identified RV early diastolic velocity as the sole variable independently associated with arrhythmic history (RV Ea: 4.5 +/- 1 vs. 6.7 +/- 2 cm/s, p = 0.01). A cut-off for RV Ea of < 6.1 cm/s identified patients in the arrhythmic group with 86% sensitivity and 59% specificity (AUC = 0.8). CONCLUSIONS: Our results suggest that TDI may detect RV dysfunction in patients with apparently normal function as assessed by conventional echocardiographic parameters. Reduction in RV early diastolic velocity appears to be an early abnormality and is associated with occurrence of arrhythmic events. TDI may be useful in risk stratification of patients with repaired tetralogy of Fallot.
Resumo:
FUNDAMENTO: A avaliação da função Ventricular Direita (VD) pelo ecocardiograma em pacientes com Tromboembolismo Pulmonar (TEP) é complexa, frequentemente qualitativa; o Doppler tecidual tem sido utilizado para avaliação semiquantitativa dessa câmara, com algumas limitações. OBJETIVO: Avaliar a função do VD no TEP pelo ecocardiograma com Doppler tecidual, complementando com o peptídeo atrial natriurético (BNP). MÉTODOS: Foram estudados pacientes com TEP pelo ecocardiograma com Doppler tecidual e BNP até 24 horas do diagnóstico, obtendo-se as velocidades miocárdicas (s'), strain, strain rate e índice de performance miocárdica do VD; disfunção do VD foi iagnosticada por hipocinesia da câmara, movimento anormal septal e relação VD/VE >1. De acordo com o BNP os pacientes foram divididos em Grupo I, BNP < 50 pg/mL e Grupo II, BNP > 50 pg/mL. RESULTADOS: De 118 pacientes, 100 (60 homens, idade = 55 ± 17 anos) foram analisados; observou-se disfunção do VD em 28%, mais frequentemente no grupo II (19 vs. 9 pacientes, p < 0,001). O grupo II era mais idoso (64 ± 19 vs. 50 ± 15 anos), apresentava menor velocidade de s' (10,5 ± 3,5 vs. 13,2 ± 3,1 cm/s) e maior pressão pulmonar (48 ± 11 vs. 35 ± 11 mmHg), p < 0,001 para todos. O ponto de corte de s' para disfunção do VD foi de 10,8 cm/s (especificidade = 85%, sensibilidade = 54%), com moderada correlação entre o BNP e a onda s'(r = -0,39). CONCLUSÃO: No TEP, a disfunção do VD pelo ecocardiograma se acompanha de elevação do BNP; apesar confirmar adequadamente a presença de disfunção do VD, o Doppler tecidual apresenta sensibilidade limitada para este diagnóstico.
Resumo:
Diagnosis, prognosis and evaluation of death risk in Chagas cardiomyopathy still constitute a challenge due to the diversity of manifestations, which determine the importance of using echocardiography, tissue Doppler and biomarkers. To evaluate, within a systematic review, clinical and echocardiographic profiles of patients with chronic chagasic cardiomyopathy, which may be related to worse prognosis and major mortality risk. To perform the systematic review, we used Medline (via PubMed), LILACS and SciELO databases to identify 82 articles published from 1991 to 2012, with the following descriptors: echocardiography, mortality and Chagas disease. We selected 31 original articles, involving diagnostic and prognostic methods. The importance of Chagas disease has increased due to its emergence in Europe and United States, but most evidence came from Brazil. Among the predictors of worse prognosis and higher mortality risk are morphological and functional alterations in the left and right ventricles, evaluated by conventional echocardiography and tissue Doppler, as well as the increase in brain natriuretic peptide and troponin I concentrations. Recently, the evaluations of dyssynchrony, dysautonomia, as well as strain, strain rate and myocardial twisting were added to the diagnostic arsenal for the early differentiation of Chagas cardiomyopathy. Developments in imaging and biochemical diagnostic procedures have enabled more detailed cardiac evaluations, which demonstrate the early involvement of both ventricles, allowing a more accurate assessment of the mortality risk in Chagas disease.
Development of an optimized methodology for tensile testing of carbon steels in hydrogen environment
Resumo:
The study was performed at OCAS, the Steel Research Centre of ArcelorMittal for the Industry market. The major aim of this research was to obtain an optimized tensile testing methodology with in-situ H-charging to reveal the hydrogen embrittlement in various high strength steels. The second aim of this study has been the mechanical characterization of the hydrogen effect on hight strength carbon steels with varying microstructure, i.e. ferrite-martensite and ferrite-bainite grades. The optimal parameters for H-charging - which influence the tensile test results (sample geometry type of electrolyte, charging methods effect of steel type, etc.) - were defined and applied to Slow Strain Rate testing, Incremental Step Loading and Constant Load Testing. To better understand the initiation and propagation of cracks during tensile testing with in-situ H-charging, and to make the correlation with crystallographic orientation, some materials have been analyzed in the SEM in combination with the EBSD technique. The introduction of a notch on the tensile samples permits to reach a significantly improved reproducibility of the results. Comparing the various steel grades reveals that Dual Phase (ferrite-martensite) steels are more sensitive to hydrogen induced cracking than the FB (ferritic-bainitic) ones. This higher sensitivity to hydrogen was found back in the reduced failure times, increased creep rates and enhanced crack initiation (SEM) for the Dual Phase steels in comparison with the FB steels.
Resumo:
DNA sequence variation has been associated with quantitative changes in molecular phenotypes such as gene expression, but its impact on chromatin states is poorly characterized. To understand the interplay between chromatin and genetic control of gene regulation, we quantified allelic variability in transcription factor binding, histone modifications, and gene expression within humans. We found abundant allelic specificity in chromatin and extensive local, short-range, and long-range allelic coordination among the studied molecular phenotypes. We observed genetic influence on most of these phenotypes, with histone modifications exhibiting strong context-dependent behavior. Our results implicate transcription factors as primary mediators of sequence-specific regulation of gene expression programs, with histone modifications frequently reflecting the primary regulatory event.
Resumo:
The concentration of circulating glucocorticoids is regulated in response to environmental and endogenous conditions. Total circulating corticosterone, the main glucocorticoid in birds, consists of a fraction which is bound to corticosterone-binding globulins (CBG) and a free fraction. There is increasing evidence that the environment modulates free corticosterone levels through varying the concentration of CBG, but experimental evidence is lacking. To test the hypothesis that the regulation of chronic stress in response to endogenous and environmental conditions involves variation in both corticosterone release and CBG capacity, we performed an experiment with barn owl (Tyto alba) nestlings in two different years with pronounced differences in environmental conditions and in nestlings experimentally fed ad libitum. In half of the individuals we implanted a corticosterone-releasing pellet to artificially increase corticosterone levels and in the other half we implanted a placebo pellet. We then repeatedly collected blood samples to measure the change in total and free corticosterone levels as well as CBG capacity. The increase in circulating total corticosterone after artificial corticosterone administration varied with environmental conditions and with the food regime of the nestlings. The highest total corticosterone levels were found in nestlings growing up in poor environmental conditions and the lowest in ad libitum fed nestlings. CBG was highest in the year with poor environmental conditions, so that, contrary to total corticosterone, free corticosterone levels were low under poor environmental conditions. When nestlings were fed ad libitum total corticosterone, CBG and free corticosterone did not increase when administering corticosterone. These results suggest that depending on the individual history an animal experienced during development the HPA-axis is regulated differently.
Resumo:
Carbonate mylonites with varying proportions of second-phase minerals were collected at positions of increasing metamorphic grade along the basal thrust of the Morcles nappe (Helvetic nappes, Switzerland). Variations of temperature, stress, and strain rate, changes in chemistry of solid and fluid phases, and differing degrees of strain localization and annealing were tracked by measuring the shapes, mean sizes, and size distributions of both matrix and second-phase grains, as well as crystal preferred orientation (CPO) of the matrix. Field structures suggest that strain rate was constant along the fault. The mean and distribution of the calcite grain sizes were affected most profoundly by temperature: Increased temperature, presumably accompanied by decreased stress, correlated with larger mean sizes and wider size distributions. At a given location, the matrix grains in mylonites with more second-phase particles are, on average, smaller, have narrower size distributions, and have more elongate shapes. For example, mylonites with 50 vol.% of second phases have matrix grain sizes half that of pure mylonites. Changes in calcite chemistry and the presence of synkinematic fluids seemed to influence microfabric only weakly. Temporal variations in conditions, such as exhumation-induced cooling, apparently provoke changes in temperature, stress, and strain rate along the nappe. These changes result in further strain localization during retrograde conditions and cause the grain size to be reduced by an additional 50%. The matrix CPO strengthens with increasing temperature or strain, but weakens and rotates with increasing second-phase content, These fabric changes suggest differing rates of grain growth, grain size reduction, and development of CPO owing to variations in the deformation conditions and, perhaps, mechanisms. To interpret natural mylonite structures or to extrapolate mechanical data to natural situations requires careful characterization of the microfabric, and, in particular, second-phase minerals. (c) 2007 Elsevier B.V, All rights reserved.
Resumo:
This study on suicide attempts is part of a large research project on dependent behavior in adolescents and young adults. 228 subjects aged 14-25 (107 "drug abusers," 121 controls) from the French speaking part of Switzerland were evaluated on the basis of a semi-structured interview (Mini International Neuropsychiatric Interview), enabling a DSM-IV diagnosis, and self-reports (SSS by Zuckermann, MMPI-2, IDI by Hirschfeld). 31.5% of "drug abuser" males and 41.2% of "drug abuser" females committed one or more suicide attempts. The results of a logistic regression show that the significant factor explaining suicide attempts in drug users is emotional reliance for males and experience-seeking for females.
Resumo:
Convective flows of a small Prandtl number fluid contained in a two-dimensional cavity subject to a lateral thermal gradient are numerically studied by using different techniques. The aspect ratio (length to height) is kept at around 2. This value is found optimal to make the flow most unstable while keeping the basic single-roll structure. Two cases of thermal boundary conditions on the horizontal plates are considered: perfectly conducting and adiabatic. For increasing Rayleigh numbers we find a transition from steady flow to periodic oscillations through a supercritical Hopf bifurcation that maintains the centrosymmetry of the basic circulation. For a Rayleigh number of about ten times that of the Hopf bifurcation the system initiates a complex scenario of bifurcations. In the conductive case these include a quasiperiodic route to chaos. In the adiabatic one the dynamics is dominated by the interaction of two Neimark-Sacker bifurcations of the basic periodic solutions, leading to the stable coexistence of three incommensurate frequencies, and finally to chaos. In all cases, the complex time-dependent behavior does not break the basic, single-roll structure.
Resumo:
It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.