916 resultados para Soft Tissue
Resumo:
Background Numerous studies demonstrate the generation and short-term survival of adipose tissue; however, long-term persistence remains elusive. This study evaluates long-term survival and transferability of de novo adipose constructs based on a ligated vascular pedicle and tissue engineering chamber combination. Methods Defined adipose tissue flaps were implanted into rats in either intact or perforated domed chambers. In half of the groups, the chambers were removed after 10 weeks and the constructs transferred on their vascular pedicle to a new site, where they were observed for a further 10 weeks. In the remaining groups, the tissue construct was observed for 20 weeks inside the chamber. Tissue volume was assessed using magnetic resonance imaging and histologic measures, and constructs were assessed for stability and necrosis. Sections were assessed histologically and for proliferation using Ki-67. Results At 20 weeks, volume analysis revealed an increase in adipose volume from 0.04 ± 0.001 ml at the time of insertion into the chambers to 0.27 ± 0.004 ml in the closed and 0.44 ± 0.014 ml in the perforated chambers. There was an additional increase of approximately 10 to 15 percent in tissue volume in flaps that remained in chambers for 20 weeks, whereas the volume of the transferred tissue not in chambers remained unaltered. Histomorphometric assessment of the tissues documented no signs of hypertrophy, fat necrosis, or atypical changes of the newly generated tissue. Conclusion This study presents a promising new method of generating significant amounts of mature, vascularized, stable, and transferable adipose tissue for permanent autologous soft-tissue replacement.
Resumo:
We initially described a rat chamber model with an inserted arteriovenous pedicle which spontaneously generates 3-dimensional vascularized connective tissue (Tanaka Y et al., Br J Plast Surg 2000; 53: 51-7). More recently we have developed a murine chamber model containing reconstituted basement membrane (Matrigel®) and FGF-2 that generates vascularized adipose tissue in vivo (Cronin K et al., Plast Reconstr Surg 2004; in press). We have extended this work to assess the cellular and matrix requirements for the Matrigel®- induced neo-adipogenesis. We found that chambers sealed to host fat were unable to grow new adipose tissue. In these chambers the Matrigel® became vascularized with maximal outgrowth of vessels extending to the periphery at 6 weeks. A small amount of adipose tissue was found adjacent to the vessels, most likely arising from periadventitial adipose tissue. In contrast, chambers open to interaction with endogenous adipose tissue showed abundant new fat, and partial exposure to adjacent adipose tissue clearly showed neo-adipogenesis only in this area. Addition of small amounts of free fat to the closed chamber containing Matrigel® was able to induce neo-adipogenesis. Addition of small pieces of human fat also caused neo-adipogenesis in immunocompromised (SCID) mice. Also, we found Matrigel® to induce adipogenesis of Lac-Z-tagged (Rosa-26) murine bone marrow-derived mesenchymal stem cells, and cells similar to these have been isolated from human adipose tissue. Given that Matrigel® is a mouse product and cannot be used in humans, we have started investigating alternative matrix scaffolds for adipogenesis such as the PDA-approved PLGA, collagen and purified components derived from Matrigel®, such as laminin-1. The optimal conditions for adipogenesis with these matrices are still being elucidated. In conclusion, we have demonstrated that a precursor cell source inside the chamber is essential for the generation of vascularized adipose tissue in vivo. This technique offers unique potential for the reconstruction of soft tissue defects and may enable the generation of site-specific tissue using the correct microenvironment.
Resumo:
Resection of musculoskeletal sarcoma can result in large bone defects where regeneration is needed in a quantity far beyond the normal potential of self-healing. In many cases, these defects exhibit a limited intrinsic regenerative potential due to an adjuvant therapeutic regimen, seroma, or infection. Therefore, reconstruction of these defects is still one of the most demanding procedures in orthopaedic surgery. The constraints of common treatment strategies have triggered a need for new therapeutic concepts to design and engineer unparalleled structural and functioning bone grafts. To satisfy the need for long-term repair and good clinical outcome, a paradigm shift is needed from methods to replace tissues with inert medical devices to more biological approaches that focus on the repair and reconstruction of tissue structure and function. It is within this context that the field of bone tissue engineering can offer solutions to be implemented into surgical therapy concepts after resection of bone and soft tissue sarcoma. In this paper we will discuss the implementation of tissue engineering concepts into the clinical field of orthopaedic oncology.
Resumo:
Experimental observations of the time-dependent mechanical responses of collagenous tissues have demonstrated behavior that deviates from standard treatments of linear or quasi-linear viscoelasticity. In particular, time-dependent deformation can be strongly coupled to strain level, and strain-rate independence can be observed under monotonic loading, even for a tissue with dramatic stress relaxation. It was postulated that this nonlinearity is fundamentally associated with gradual recruitment of individual collagen fibrils during applied mechanical loading. Based on previously observed experimental results for the time-dependent response of collagenous soft tissues, a model is developed to describe the mechanical behavior of these tissues under uniaxial loading. Tissue stresses, under applied strain-controlled loading, are assumed to be a sum of elastic and viscoelastic stress contributions. The relative contributions of elastic and viscoelastic stresses is assumed to vary with strain level, leading to strain- and time-dependent mechanical behavior. The model formulation is examined under conditions of monotonic loading at varying constant strain rates and stress-relaxation at different applied strain levels. The model is compared with experimental data for a membranous biological soft tissue, the amniotic sac, and is found to agree well with experimental results. The limiting behavior of the novel model, at large strains relative to the collagen recruitment, is consistent with the quasi-linear viscoelastic approach. © 2006 Materials Research Society.
Resumo:
In the current study, the effects of polar solvents on tissue volume and mechanical properties are considered. Area shrinkage measurements are conducted for mineralized bone tissue samples soaked in polar solvents. Area shrinkage is used to calculate approximate linear and volume shrinkage. Results are compared with viscoelastic mechanical parameters for bone in the same solvents (as measured previously) and with both shrinkage measurements and mechanical data for nonmineralized tissues, as taken from the existing literature. As expected, the shrinkage of mineralized tissues is minimal when compared with shrinkage of nonmineralized tissues immersed in the same polar solvents. The mechanical changes in bone are also substantially less than in nonmineralized tissues. The largest stiffness values are found in shrunken bone samples (immersed in acetone and ethanol). The mineral phase in bone thus resists tissue shrinkage that would otherwise occur in the pure soft tissue phase. © 2007 Materials Research Society.
Resumo:
Tese de doutoramento, Medicina Dentária (Periodontologia), Universidade de Lisboa, Faculdade de Medicina Dentária, 2016
Resumo:
Little is known about the effect of edaphic conditions on the decomposition of buried mammalian tissues. To address this, we set up a replicated incubation study with three fresh soils of contrasting pH: a Podsol (acidic), a Cambisol (neutral), and a Rendzina (alkaline), in which skeletal muscle tissue (SMT) of known mass was allowed to decompose. Our results clearly demonstrated that soil type had a considerable effect on the decomposition of SMT buried in soil. Differences in the rate of decomposition were up to three times greater in the Podsol compared with the Rendzina. The rate of microbial respiration was correlated to the rate of soft tissue loss, which suggests that the decomposition of SMT is dependent on the microbial community present in the soil. Decompositional by-products caused the pH of the immediate soil environment to change, becoming more alkaline at first, before acidifying. Our results demonstrate the need for greater consideration of soil type in future taphonomic studies.
Resumo:
Aim: To study the influence on the healing of soft and hard peri-implant tissues when implants of different sizes and configurations were installed into sockets immediately after tooth extraction.Material and methods: Transmucosal cylindrical implants, 3.3 mm in diameter in the control sites, and conical 5 mm in diameter in the test sites, were installed into the distal socket of the fourth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant test sites (conical; 3.8 mm) was more resorbed compared with the control sites (cylindrical; 1.6 mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the peri-implant mucosa was located more apically at the test compared with the control sites.Conclusion: The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level, if the distance between the implant surface and the outer contour of the alveolar crest is small.
Resumo:
AimTo evaluate the influence (i) of various implant platform configurations and (ii) of implant surface characteristics on peri-implant tissue dimensions in a dog model.Material and methodsMandibular premolars and first molars were extracted bilaterally in six Labrador dogs. After 3 months of healing, two implants, one with a turned and a second with a moderately rough surface, were installed on each side of the mandible in the premolar region. on the right side of the mandible, implants with a tapered and enlarged platform were used, while standard cylindrical implants were installed in the left side of the mandible. Abutments with the diameter of the cylindrical implants were used resulting in a mismatch of 0.25 mm at the tapered implant sites. The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.ResultsAll implants were completely osseointegrated. A minimal buccal bone resorption was observed for both implant configurations and surface topographies. Considering the animals as the statistical unit, no significant differences were found at the buccal aspect in relation to bone levels and soft tissue dimensions. The surface topographies did not influence the outcomes either.ConclusionsThe present study failed to show differences in peri-implant tissue dimensions when a mismatch of 0.25 mm from a tapered platform to an abutment was applied. The surface topographies influence a neither marginal bone resorption or peri-implant soft tissue dimension.To cite this article:Baffone GM, Botticelli D, Pantani F, Cardoso LC, Schweikert MT, Lang NP. Influence of various implant platform configurations on peri-implant tissue dimensions: an experimental study in dog.Clin. Oral Impl. Res. 22, 2011; 438-444.
Resumo:
The purpose of this study was to evaluate the host response of a human and a porcine derived acellular dermal tissue (ADT) implanted in the subcutaneous tissue of a rat model. Two subcutaneous pockets were surgically created along the dorsal midline of 25 rats (5 rats/group). The human ADT was placed superiorly and the porcine ADT, inferiorly. The animals were sacrificed at 07, 15, 30, 60 and 180 postoperative days (PO) and the ADTs and surrounding soft tissues were assessed for ultrastructural evaluation by transmission electron microscopy. The ultrastructural findings were similar in both materials. Normal collagen and elastic fibers bundles were observed during all experimental moments, as well as macrophages presenting cytoplasmic enlargements digesting cellular portions after 15 PO. From 30 until 180 PO, vacuolar structures filled with an amorphous, electron-transparent substance, were present inside and outside the fibroblasts. Both human and porcine ADT showed similar pattern of ultrastructural response when implanted in the subcutaneous tissue of rats. The porcine ADT appears as a good alternative to be used as a biomaterial.
Resumo:
Aim: To evaluate the influence of a sub-epithelial connective tissue graft placed at the buccal aspect of implants installed immediately after tooth extraction on the dimensional changes of hard and soft tissues. Materials and Methods: In six Labrador dogs a bilateral partial- thickness dissection was made buccal to the second mandibular premolar. At the lingual aspect, full-thickness flaps were elevated. The teeth were extracted and implants installed immediately into the distal socket. A connective tissue graft was obtained from the palate and applied to the buccal aspect of the test sites, whereas contra-laterally, no graft was applied. The flaps were sutured to allow a non-submerged installation. After 4 months of healing, the animals were sacrificed, ground sections were obtained and histomorphometric analyses were performed. Results: After 4 months of healing, all implants were integrated (n = 6). Both at the test and at the control sites bone resorption occurred: 1.6 mm and 2.1 mm, respectively. The difference was not statistically significant. The coronal aspect of the peri-implant soft tissue was wider and located more coronally at the test compared with the control sites. The differences were statistically significant. Conclusions: The application of a connective tissue graft placed at the buccal aspect of the bony wall at implants installed immediately after tooth extraction yielded a minimal preservation of the hard tissues. The peri-implant mucosa, however, was significantly thicker and more coronally positioned at the test compared with the control sites. © 2012 John Wiley & Sons A/S.
Resumo:
Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.
Resumo:
Background: The aim of this clinical study is to evaluate the 2-year term results of gingival recession (GR) associated with non-carious cervical lesions (NCCLs) treated by connective tissue graft (CTG) alone or in combination with a resin-modified glass ionomer restoration (CTG+R). Methods: Thirty-six patients with Miller Class I buccal GR associated with NCCLs completed the follow-up. The defects were randomly assigned to receive either CTG or CTG+R. Bleeding on probing (BOP), probing depth (PD), relative GR, clinical attachment level (CAL), and cervical lesion height coverage were measured at baseline, 6 months, 1 year, and 2 years after treatment. Results: Both groups showed statistically significant gains in CAL and soft-tissue coverage. The differences between groups were not statistically significant in BOP, PD, relative GR, or CAL after 2 years. Cervical lesion height coverage was 79.31% ± 18.51% for CTG and 71.95% ± 13.25% for CTG+R (P >0.05). Estimated root coverage was 91.56% ± 11.74% for CTG and 93.29% ± 7.97% for CTG+R (P ≥0.05). Conclusions: Within the limits of the present study, it can be concluded that both procedures provide comparable soft tissue coverage after 2 years of follow-up.
Resumo:
ObjectiveTo study the buccal dimensional tissue changes at oral implants following free gingival grafting, with or without including the keratin layer, performed at the time of implant installation into alveolar mucosa.Material and methodsThe mandibular premolars and first molars were extracted bilaterally in six Beagle dogs. In the right side of the mandible (Test), flaps were first elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. An incision of the periosteum at the buccal aspect was performed to allow the flap to be coronally repositioned. Primary wound closure was obtained. In the left side, the masticatory (keratinized) mucosa was left in situ, and no sutures were applied (Control). After 3months of healing, absence of keratinized mucosa was confirmed at the test sites. Two recipient sites were prepared at each side of the mandible in the region of the third and fourth premolars. All implants were installed with the shoulder placed flush with the buccal alveolar bony crest, and abutments were connected to allow a non-submerged healing. Two free gingival mucosal grafts were harvested from the buccal region of the maxillary canines. One graft was left intact (gingival mucosal graft), while for the second, the epithelial layer was removed (gingival connective tissue graft). Subsequently, the grafts were fixed around the test implants in position of the third and fourth premolars, respectively. After 3months, the animals were euthanized and ground sections obtained.ResultsSimilar bony crest resorption and coronal extension of osseointegration were found at test and control sites. Moreover, similar dimensions of the peri-implant soft tissues were obtained at test and control sites.ConclusionsThe increase in the alveolar mucosal thickness by means of a gingival graft affected the peri-implant marginal bone resorption and soft tissue recession around implants. This resulted in outcomes that were similar to those at implants surrounded by masticatory mucosa, indicating that gingival grafting in the absence of keratinized mucosa around implants may reduce the resorption of the marginal crest and soft tissue recession.
Resumo:
The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.