943 resultados para Scattering Anelastico Neutroni Diffusione Neutrone ILL Diffrattometro Fonone


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invasive fungal infections are an increasingly frequent etiology of sepsis in critically ill patients causing substantial morbidity and mortality. Candida species are by far the predominant agent of fungal sepsis accounting for 10% to 15% of health-care associated infections, about 5% of all cases of severe sepsis and septic shock and are the fourth most common bloodstream isolates in the United States. One-third of all episodes of candidemia occur in the intensive care setting. Early diagnosis of invasive candidiasis is critical in order to initiate antifungal agents promptly. Delay in the administration of appropriate therapy increases mortality. Unfortunately, risk factors, clinical and radiological manifestations are quite unspecific and conventional culture methods are suboptimal. Non-culture based methods (such as mannan, anti-mannan, β-d-glucan, and polymerase chain reaction) have emerged but remain investigational or require additional testing in the ICU setting. Few prophylactic or pre-emptive studies have been performed in critically ill patients. They tended to be underpowered and their clinical usefulness remains to be established under most circumstances. The antifungal armamentarium has expanded considerably with the advent of lipid formulations of amphotericin B, the newest triazoles and the echinocandins. Clinical trials have shown that the triazoles and echinocandins are efficacious and well tolerated antifungal therapies. Clinical practice guidelines for the management of invasive candidiasis have been published by the European Society for Clinical Microbiology and Infectious Diseases and the Infectious Diseases Society of North America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until recently, the hard X-ray, phase-sensitive imaging technique called grating interferometry was thought to provide information only in real space. However, by utilizing an alternative approach to data analysis we demonstrated that the angular resolved ultra-small angle X-ray scattering distribution can be retrieved from experimental data. Thus, reciprocal space information is accessible by grating interferometry in addition to real space. Naturally, the quality of the retrieved data strongly depends on the performance of the employed analysis procedure, which involves deconvolution of periodic and noisy data in this context. The aim of this article is to compare several deconvolution algorithms to retrieve the ultra-small angle X-ray scattering distribution in grating interferometry. We quantitatively compare the performance of three deconvolution procedures (i.e., Wiener, iterative Wiener and Lucy-Richardson) in case of realistically modeled, noisy and periodic input data. The simulations showed that the algorithm of Lucy-Richardson is the more reliable and more efficient as a function of the characteristics of the signals in the given context. The availability of a reliable data analysis procedure is essential for future developments in grating interferometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between changes in body bioelectrical impedance (BI) at 0.5, 50 and kHz and the changes in body weight, as an index of total body water changes, in acutely ill surgical patients during the rapid infusion of isotonic saline solution. DESIGN: Prospective clinical study. SETTING: Multidisciplinary surgical ICU in a university hospital. PATIENTS: Twelve male patients treated for acute surgical illness (multiple trauma n = 5, major surgery n = 7). Selection criteria: stable cardiovascular parameters, normal cardiac function, signs of hypovolemia (CVP < or = 5 mmHg, urine output < 1 ml/kg x h). INTERVENTIONS: After baseline measurements, a 60 min fluid challenge test was performed with normal saline solution, 0.25 ml/kg/min [corrected]. MEASUREMENTS AND RESULTS: Body weight (platform digital scale), total body impedance (four-surface electrode technique; measurements at 0.5, 50 and 100 kHz) and urine output. Fluid retention induced a progressive decrease in BI at 0.5, 50 and 100 kHz, but the changes were significant for BI 0.5 and BI 100 only, from 40 min after the beginning of the fluid therapy onwards. There was a significant negative correlation between changes in water retention and BI 0.5, with individual correlation coefficients ranging from -0.72 to 0.95 (p < 0.01-0.0001). The slopes of the regression lines indicated that for each kg of water change, there was a mean decrease in BI of 18 ohm, but a substantial inter-individual variability was noted. CONCLUSION: BI measured at low frequency can represent a valuable index of acute changes in body water in a group of surgical patients but not in a given individual.