987 resultados para STEADY-STATE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The higher concentration during exercise at which lactate entry in blood equals its removal is known as maximal lactate steady state (MLSS) and is considered an important indicator of endurance exercise capacity. The aim of the present study was to determine MLSS in running rats. Adult male Wistar sedentary rats, which were selected and adapted to treadmill running for three weeks, were used. After becoming familiarized with treadmill running, the rats were submitted to five exercise tests at 15, 20, 25, 30 and 35 m/min velocities. The velocity sequence was distributed at random. Each test consisted of continuous running for 25 min at one velocity or until the exhaustion. Blood lactate was determined at rest and each 5 min of exercise to find the MLSS. The running rats presented MLSS at the 20 m/min velocity, with blood lactate of 3.9±1.1 mmol/L. At the 15 m/min velocity, the blood lactate also stabilized, but at a lower concentration (3.2±1.1 mmol/L). There was a progressive increase in blood lactate concentration at higher velocities, and some animals reached exhaustion between the 10 th and 25 th minute of exercise. These results indicate that the protocol of MLSS can be used for determination of the maximal aerobic intensity in running rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze changes in stroke rate (SR), stroke length (SL) and stroke phases (entry and catch, pull, push and recovery) when swimming at (MLSS) and above (102.5% MLSS) the maximal lactate steady state. Twelve endurance swimmers (21±8 year, 1.77±0.10m and 71.6±7.7kg) performed in different days the following tests: (1) 200- and 400-m all-out tests, to determine critical speed (CS), and; (2) 2-4 30-min sub-maximal constant-speed tests, to determine the MLSS and 102.5% MLSS. There was significant difference among MLSS (1.22±0.05ms-1), 102.5% MLSS (1.25±0.04ms-1) and CS (1.30±0.08ms-1). SR and SL were maintained between the 10th and 30th minute of the test swum at MLSS and have modified significantly at 102.5% MLSS (SR - 30.9±3.4 and 32.2±3.5cyclesmin-1 and SL - 2.47±0.2 and 2.38±0.2mcycle-1, respectively). All stroke phases were maintained at 10th and 30th minute at MLSS. However, the relative duration of propulsive phase B (pull) increased significantly at 102.5% MLSS (21.7±3.4% and 22.9±3.9%, respectively). Therefore, the metabolic condition may influence the stroke parameters (SR and SL) and stroke strategy to maintain the speed during swim tests lasting 30min. © 2010 Sports Medicine Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the calculation of the steady-state operation of a radial/meshed electrical distribution system (EDS) through solving a system of linear equations (non-iterative load flow) is presented. The constant power type demand of the EDS is modeled through linear approximations in terms of real and imaginary parts of the voltage taking into account the typical operating conditions of the EDS's. To illustrate the use of the proposed set of linear equations, a linear model for the optimal power flow with distributed generator is presented. Results using some test and real systems show the excellent performance of the proposed methodology when is compared with conventional methods. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim of this study was to verify the possibility of lactate minimum (LM) determination during a walking test and the validity of such LM protocol on predicting the maximal lactate steady-state (MLSS) intensity. Design. Eleven healthy subjects (24.2 ± 4.5 yr; 74.3 ± 7.7 kg; 176.9 ± 4.1 cm) performed LM tests on a treadmill, consisting of walking at 5.5 km h -1 and with 20-22% of inclination until voluntary exhaustion to induce metabolic acidosis. After 7 minutes of recovery the participants performed an incremental test starting at 7% incline with increments of 2% at each 3 minutes until exhaustion. A polynomial modeling approach (LMp) and a visual inspection (LMv) were used to identify the LM as the exercise intensity associated to the lowest [bLac] during the test. Participants also underwent to 24 constant intensity tests of 30 minutes to determine the MLSS intensity. Results. There were no differences among LMv (12.6 ± 1.7 %), LMp (13.1 ± 1.5 %), and MLSS (13.6 ± 2.1 %) and the Bland and Altman plots evidenced acceptable agreement between them. Conclusion. It was possible to identify the LM during walking tests with intensity imposed by treadmill inclination, and it seemed to be valid on identifying the exercise intensity associated to the MLSS. Copyright © 2012 Guilherme Morais Puga et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To compare five different protocols for estimating the lactate minimum speed (LMS) with that for estimating the maximal lactate steady state (MLSS) in Arabian horses, in order to obtain a more rapid method for monitoring aerobic capacity and prescribing training schedules. METHODS: Eight purebred Arabian horses were conditioned to exercise on a treadmill for 12 days then submitted to three to five exercise sessions to determine the MLSS. Blood samples were collected from a jugular catheter at specific intervals for measurement of lactate concentrations. The MLSS was the velocity maintained during the last 20 minutes of constant submaximal exercise, at which the concentration of lactate increased by no more than 1.0 mmol/L. The LMS test protocols (P1 - P5) included a warm-up period followed by a high-intensity gallop. The speed was then reduced to 4 m/s, and the incremental portion of the test was initiated. In P1, P2, and P3, the velocity increment was 0.5 m/s, and the duration of each incremental stage was three, five and seven minutes, respectively. In P4 and P5, the velocity increments were 1.0 and 1.5 m/s, respectively, and the duration of the stages was fixed at five minutes each. A second-degree polynomial function was fitted to the lactate-velocity curve, and the velocity corresponding to the lowest concentration of lactate was the LMS. RESULTS: Only the mean LMS determined by P1 and P2 did not differ from the velocity determined by the MLSS test (p > 0.1). There was a strong correlation (r >0.6) between P1 and the MLSS velocity. A limits of agreement plot revealed that the best agreement occurred between the MLSS test and P1 (mean bias = 0.14 m/s), followed by P2 (bias = -0.22 m/s). The lactate concentrations associated with the various LMS protocols did not differ. CONCLUSIONS: This study shows the variation between protocols of the LMS test for determining the onset of blood lactate accumulation but also reveals that, at least for Arabian horses, the P1 protocol of the LMS has good agreement with the MLSS. © 2013 Copyright New Zealand Veterinary Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO:Relatar o caso de um lactente com citomegalovírus congênito e disacusia neurossensorial progressiva, analisado por três métodos de avaliação auditiva.DESCRIÇÃO DO CASO:Na primeira avaliação auditiva, aos quatro meses de idade, o lactente apresentou ausência de Emissões Otoacústicas (EOA) e Potencial Evocado Auditivo de Tronco Encefálico (PEATE) dentro dos padrões de normalidade para a faixa etária, com limiar eletrofisiológico em 30dBnHL, bilateralmente. Com seis meses, apresentou ausência de PEATE bilateral em 100dBnHL. A avaliação comportamental da audição mostrou-se prejudicada devido ao atraso no desenvolvimento neuropsicomotor. Aos oito meses, foi submetido ao exame de Resposta Auditiva de Estado Estável (RAEE) e os limiares encontrados foram 50, 70, ausente em 110 e em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à direita, e 70, 90, 90 e ausente em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à esquerda.COMENTÁRIOS:Na primeira avaliação, o lactente apresentou alteração auditiva no exame de EOA e PEATE normal, que passou a ser alterado aos seis meses de idade. A intensidade da perda auditiva só pôde ser identificada pelo exame de RAEE, permitindo estabelecer a melhor conduta na adaptação de aparelho de amplificação sonora individual. Ressalta-se a importância do acompanhamento audiológico para crianças com CMV congênito.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The steady-state average run length is used to measure the performance of the recently proposed synthetic double sampling (X) over bar chart (synthetic DS chart). The overall performance of the DS X chart in signaling process mean shifts of different magnitudes does not improve when it is integrated with the conforming run length chart, except when the integrated charts are designed to offer very high protection against false alarms, and the use of large samples is prohibitive. The synthetic chart signals when a second point falls beyond the control limits, no matter whether one of them falls above the centerline and the other falls below it; with the side-sensitive feature, the synthetic chart does not signal when they fall on opposite sides of the centerline. We also investigated the steady-state average run length of the side-sensitive synthetic DS X chart. With the side-sensitive feature, the overall performance of the synthetic DS X chart improves, but not enough to outperform the non-synthetic DS X chart. Copyright (C) 2014 John Wiley &Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to establish the validity of the anaerobic threshold (AT) determined on the soccer-specific Hoff circuit (AT(Hoff)) to predict the maximal lactate steady-state exercise intensity (MLSSHoff) with the ball. Sixteen soccer players (age: 16.0 +/- 0.5 years; body mass: 63.7 +/- 9.0 kg; and height: 169.4 +/- 5.3 cm) were submitted to 5 progressive efforts (7.0-11.0 km.h(-1)) with ball dribbling. Thereafter, 11 players were submitted to 3 efforts of 30 minutes at 100, 105, and 110% of AT(Hoff). The AT(Hoff) corresponded to the speed relative to 3.5 mmol.L-1 lactate concentration. The speed relative to 4.0 mmol.L-1 was assumed to be AT(Hoff4.0), and the AT(HoffBI) was determined through bisegmented adjustment. For comparisons, Student's t-test, intraclass correlation coefficient (ICC), and Bland and Altman analyses were used. For reproducibility, ICC, typical error, and coefficient of variation were used. No significant difference was found between AT test and retest determined using different methods. A positive correlation was observed between AT(Hoff) and AT(Hoff4.0). The MLSSHoff (10.6 +/- 1.3 km.h(-1)) was significantly different compared with AT(Hoff) (10.2 +/- 1.2 km.h(-1)) and AT(HoffBI) (9.5 +/- 0.4 km.h(-1)) but did not show any difference from LAn(Hoff4.0) (10.7 +/- 1.4 km.h(-1)). The MLSSHoff presented high ICCs with AT(Hoff) and AT(Hoff4.0) (ICC = 0.94; and ICC = 0.89; p <= 0.05, respectively), without significant correlation with AT(HoffBI). The results suggest that AT determined on the Hoff circuit is reproducible and capable of predicting MLSS. The AT(Hoff4.0) was the method that presented a better approximation to MLSS. Therefore, it is possible to assess submaximal physiological variables through a specific circuit performed with the ball in young soccer players.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize the thresholds of the auditory steady-state response that relates to term newborns and infants. Design: The study was cross-sectional using auditory steadystate response assessment, and the real-ear-to-dial difference was measured in the external auditory canal. Study Sample: The study group included 60 newborns and infants between the age of 0 and 6 months. Results: A statistically significant difference was found in the carrier frequency variable for auditory steady-state response thresholds but not in comparison to ages. Furthermore, there is an association between auditory steady-state response thresholds and the real-ear-to-dial difference. Conclusion: The same threshold can be used as a normality reference for this age range, with distinct values for the different carrier frequencies. The influence of external auditory canal amplification should be taken into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is well known that constant-modulus-based algorithms present a large mean-square error for high-order quadrature amplitude modulation (QAM) signals, which may damage the switching to decision-directed-based algorithms. In this paper, we introduce a regional multimodulus algorithm for blind equalization of QAM signals that performs similar to the supervised normalized least-mean-squares (NLMS) algorithm, independently of the QAM order. We find a theoretical relation between the coefficient vector of the proposed algorithm and the Wiener solution and also provide theoretical models for the steady-state excess mean-square error in a nonstationary environment. The proposed algorithm in conjunction with strategies to speed up its convergence and to avoid divergence can bypass the switching mechanism between the blind mode and the decision-directed mode. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The steady state kinetic mechanism of the H(2)O(2)-supported oxidation of different organic substrates by peroxidase from leaves of Chamaerops excelsa palm trees (CEP) has been investigated. An analysis of the initial rates vs. H(2)O(2) and reducing substrate concentrations is consistent with a substrate-inhibited Ping-Pong Bi Bi reaction mechanism. The phenomenological approach expresses the peroxidase Ping-Pong mechanism in the form of the Michaelis-Menten equation and leads to an interpretation of the effects in terms of the kinetic parameters K(m)(H2O2)center dot K(m)(AH2)center dot k(cat)center dot K(SI)(AH2) and of the microscopic rate constants k(1) and k(3) of the shared three-step catalytic cycle of peroxidases. (C) 2011 Elsevier B.V. All rights reserved.