832 resultados para SPEECH-AID PROSTHESIS
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.
Resumo:
INTRODUCTION: The fishes of continental Brazil have socioeconomic importance due to their potential for sport fishing and commercial and subsistence uses, as seen in the Upper Paraguay River Basin, particularly in the municipalities of the Pantanal region, where it is the second largest economic activity. Injuries caused in professional fishermen are common and poorly studied, as in other regions of the country. METHODS: Data were obtained from questionnaires and interviews with 100 professional fishermen, 50 in each municipality, between December 2008 and October 2009. RESULTS: All the fishermen reported some kind of injury caused by fish stings (78% of injuries) and fish, alligator and snake bites (22%) on the hands (46% of cases) and feet (35% of cases). Most of the patients had mild symptoms. The most severe cases were associated with secondary bacterial infections and required specific treatment and prolonged recovery associated with social and economic losses. CONCLUSIONS: The results of this study indicate that the stressful work conditions, inattention to basic preventive measures and carelessness were factors that contributed to accidents and that the toxicity and ability to inflict mechanical trauma of some aquatic species, plus the ineffective use of first aid and hospital treatment, contributed to the high morbidity and complications in many cases. Data from this study are relevant to the fishing communities of the Pantanal region, since they reveal high rates of accidents, lack of knowledge concerning first aid, initial treatment, injury prevention and lack of medical follow-up of the population.
Resumo:
This dissertation analyzes the possibilities of utilizing speech-processing technologies to transform the user experience of ActivoBank’s customers while using remote banking solutions. The technologies are examined through different criteria to determine if they support the bank’s goals and strategy and whether they should be incorporated in the bank’s offering. These criteria include the alignment with ActivoBank’s values, the suitability of the technology providers, the benefits these technologies entail, potential risks, appeal to the customers and impact on customer satisfaction. The analysis suggests that ActivoBank might not be in a position to adopt these technologies at this point in time.
Resumo:
Graphics based systems of Augmented and Alternative Communication are widely used to promote communication in people with Autism Spectrum Disorders. This study discusses an integration of Augmented Reality in communication interventions, by relating elements of Augmented and Alternative Communication and Applied Behaviour Analysis strategies. An architecture for an Augmented Reality based interactive system to assist interventions is proposed. STAR provides an Augmented Reality tool to assist interventions performed by therapists and support for parents to join in and participate in the child’s intervention. Finally we report on the usage of the Augmented Reality tool in interventions with children with Autism Spectrum Disorders.
Resumo:
This work was supported by FCT (Fundação para a Ciência e Tecnologia) within Project Scope (UID/CEC/00319/2013), by LIP (Laboratório de Instrumentação e Física Experimental de Partículas) and by Project Search-ON2 (NORTE-07-0162- FEDER-000086), co-funded by the North Portugal Regional Operational Programme (ON.2 - O Novo Norte), under the National Strategic Reference Framework, through the European Regional Development Fund.
Resumo:
[Extrat] Thermoplastic profiles are very attractive due to their inherent design freedom. However, the usual methodologies employed to design extrusion forming tools, based on experimental based trial–and–error procedures, are highly dependent on the designer’s experience and lead to high resources consumption. Despite of the relatively low cost of the raw materials employed on the production of this type of profiles, the resources involved in the die design process significantly increase their cost. These difficulties are even more evident when a complex geometry profile has to be produced and there is no previous experience with similar geometries. Therefore, novel design approaches are required, in order to reduce the required resources and guarantee a good performance for the produced profile. (...)
Resumo:
This paper presents an improved version of an application whose goal is to provide a simple and intuitive way to use multicriteria decision methods in day-to-day decision problems. The application allows comparisons between several alternatives with several criteria, always keeping a permanent backup of both model and results, and provides a framework to incorporate new methods in the future. Developed in C#, the application implements the AHP, SMART and Value Functions methods.
Resumo:
Vascular grafts are used to bypass damaged or diseased blood vessels. Bacterial cellulose (BC) has been studied for use as an off-the-shelf graft. Herein, we present a novel, cost-effective, method for the production of small caliber BC grafts with minimal processing or requirements. The morphology of the graft wall produced a tensile strength above that of native vessels, performing similarly to the current commercial alternatives. As a result of the production method, the luminal surface of the graft presents similar topography to that of native vessels. We have also studied the in vivo behavior of these BC graft in order to further demonstrate their viability. In these preliminary studies, 1 month patency was achieved, with the presence of neo-vessels and endothelial cells on the luminal surface of the graft.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.
Resumo:
OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.
Resumo:
This thesis is a continuation of the Enterprise-Ireland Research Innovation Fund (RIF) Project entitled’ "Design and Manufacturing of Customised Maxillo-Facial Prostheses" The primary objective of this Internal Research Development Program (IRDP) project was to investigate two fundamental design changes 1 To incorporate the over-denture abutments directly into the implant. 2 To remove the restraining wings by the addition of screws, which affix the. implant to the dense material of the jawbone. The prosthetic was redesigned using the ANSYS Finite Element Analysis software program and analysed to* • Reduce the internal von Mises stress distribution The new prosthetic had a -63.63 % lower von Mises stress distribution when compared with the original prosthetic. • Examine the screw preload effects. A maximum relative displacement of 22 6 * lO^mm between the bone and screw was determined, which is well below the critical threshold of micromotion which prevents osseointegration • Investigate the prosthetic-bone contact interface. Three models of the screw, prosthesis, and bone, were studied. (Axisymmetnc, quarter volume, and full volume), a recommended preload torque of 0 32 Nm was applied to the prosthetic and a maximum von Mises stress of 1.988 MPa was predicted • Study the overdenture removal forces. This analysis could not be completed because the correct plastic multilinear properties of the denture material could not be established The redesigned prosthetic was successfully manufactured on a 3-axis milling machine with an indexing system The prosthetic was examined for dimensional quality and strength The research established the feasibility of the new design and associated manufacturing method.
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2007