967 resultados para SINGLE PHOTON EMISSION TOMOGRAPHY
Resumo:
Objective: Since blood viscosity (BV) is one of the most important factors determining blood flow, this study aimed to investigate the possible correlation between increased blood viscosity and reduction of regional cerebral blood flow (rCBF) in healthy ageing.Methods: Male subjects were distributed in two groups: "young", aged 20-30 (27 volunteers), or "elderly", aged 60-70 (50 volunteers). Whole blood viscosity was obtained with a Wells-Brookfield Cone/Plate Viscometer. Cerebral blood flow was analysed by means of single photon emission computed tomography (SPECT).Results: The mean BV values were 3.28 +/- 0.43 mPa in the group of young volunteers and 4.33 +/- 0.73 mPa in the group of elderly volunteers (t = -6.9, p < 0.0001). The elderly had a lower blood flow than the young in the following regions: bilateral parietal; temporal-parietal and temporal of the left hemisphere. Pearson's correlation between BV and rCBF showed a good inverse correlation when the BV was above 3.95 +/- 0.83 mPa.Conclusions: Our results point to a close relationship between the two parameters analysed, BV and rCBF. The impairment in rCBF observed in the elderly volunteers might be due to an increase in BV, among other factors.Significance: These findings suggest interesting possibilities for the treatment/prevention of brain ageing. (C) 2011 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Resumo:
Purpose of reviewTo critically review data on the use of neuroimaging tools in the clinical diagnostic investigation of dementias.Recent findingsFor many years, the use of neuroimaging tools in the evaluation of dementias has been restricted to excluding neurosurgical lesions that may account for the cognitive decline. However, modern neuroimaging extends beyond this traditional role of excluding other conditions and has a key role in the clinical investigation of Alzheimer's disease and of other degenerative cortical dementias. MRI, PET with fluorodeoxyglucose, and single-photon emission computed tomography are topographic markers of neural damage and enable the identification of specific lesional patterns that characterize Alzheimer's disease and other cortical dementias. More recently, PET amyloid markers have enabled the in-vivo assessment of amyloid load, a key feature in the physiopathology of Alzheimer's disease.SummaryThe combined use of neuroimaging examinations with clinical, neuropsychological, and cerebrospinal fluid markers can improve the specificity of the diagnosis of Alzheimer's disease, even at early stages of the disease. In the following years, progress in research will provide standardized and validated imaging markers of Alzheimer's disease and other dementias, which may increase their application in clinical settings.
Resumo:
We report on a search for large extra dimensions in a data sample of approximately 1 fb(-1) of p (p) over bar collisions at root s=1.96 TeV. We investigate Kaluza-Klein graviton production with a photon and missing transverse energy in the final state. At the 95% C.L. we set limits on the fundamental mass scale M(D) from 884 to 778 GeV for two to eight extra dimensions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Diffuse large cell non Hodgkin's lymphoma associated with chronic lymphoid leukemia (CLL), or Richter's syndrome, is a rare and serious complication. Isolated Richter's syndrome in the central nervous system is very rare; only 12 cases have been reported. We describe a 74-year-old patient with diffuse large cell non Hodgkin's lymphoma in the right frontal region with the appearance of multiform glioblastoma.
Resumo:
Objective: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. Methods: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. results: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. Conclusion: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Despite increasing interest in pathological and non-pathological dissociation, few researchers have focused on the spiritual experiences involving dissociative states such as mediumship, in which an individual (the medium) claims to be in communication with, or under the control of, the mind of a deceased person. Our preliminary study investigated psychography - in which allegedly "the spirit writes through the medium's hand" - for potential associations with specific alterations in cerebral activity. We examined ten healthy psychographers - five less expert mediums and five with substantial experience, ranging from 15 to 47 years of automatic writing and 2 to 18 psychographies per month - using single photon emission computed tomography to scan activity as subjects were writing, in both dissociative trance and non-trance states. The complexity of the original written content they produced was analyzed for each individual and for the sample as a whole. The experienced psychographers showed lower levels of activity in the left culmen, left hippocampus, left inferior occipital gyrus, left anterior cingulate, right superior temporal gyrus and right precentral gyrus during psychography compared to their normal (non-trance) writing. The average complexity scores for psychographed content were higher than those for control writing, for both the whole sample and for experienced mediums. The fact that subjects produced complex content in a trance dissociative state suggests they were not merely relaxed, and relaxation seems an unlikely explanation for the underactivation of brain areas specifically related to the cognitive processing being carried out. This finding deserves further investigation both in terms of replication and explanatory hypotheses.
Resumo:
BACKGROUND: Neoadjuvant chemoradiation (CRT) therapy may result in significant tumor regression in patients with rectal cancer. Patients who develop complete tumor regression have been managed by treatment strategies that are alternatives to standard total mesorectal excision. Therefore, assessment of tumor response with positron emission tomography/computed tomography (PET/CT) after neoadjuvant treatment may offer relevant information for the selection of patients to receive alternative treatment strategies. METHODS: Patients with clinical T2 (cT2) through cT4NxM0 rectal adenocarcinoma were included prospectively. Neoadjuvant therapy consisted of 54 grays of radiation and 5-fluorouracil-based chemotherapy. Baseline PET/CT studies were obtained before CRT followed by PET/CT studies at 6 weeks and 12 weeks after the completion of CRT. Clinical assessment was performed at 12 weeks after CRT completion. PET/CT results were compared with clinical and pathologic data. RESULTS: In total, 99 patients were included in the study. Twenty-three patients were complete responders (16 had a complete clinical response, and 7 had a complete pathologic response). The PET/CT response evaluation at 12 weeks indicated that 18 patients had a complete response, and 81 patients had an incomplete response. There were 5 false-negative and 10 false-positive PET/CT results. PET/CT for the detection of residual cancer had 93% sensitivity, 53% specificity, a 73% negative predictive value, an 87% positive predictive value, and 85% accuracy. Clinical assessment alone resulted in an accuracy of 91%. PET/CT information may have detected misdiagnoses made by clinical assessment alone, improving overall accuracy to 96%. CONCLUSIONS: Assessment of tumor response at 12 weeks after CRT completion with PET/CT imaging may provide a useful additional tool with good overall accuracy for the selection of patients who may avoid unnecessary radical resection after achieving a complete clinical response. Cancer 2012;35013511. (C) 2011 American Cancer Society.
Resumo:
Micelles composed of amphiphilic copolymers linked to a radioactive element are used in nuclear medicine predominantly as a diagnostic application. A relevant advantage of polymeric micelles in aqueous solution is their resulting particle size, which can vary from 10 to 100 nm in diameter. In this review, polymeric micelles labeled with radioisotopes including technetium (99mTc) and indium (111In), and their clinical applications for several diagnostic techniques, such as single photon emission computed tomography (SPECT), gamma-scintigraphy, and nuclear magnetic resonance (NMR), were discussed. Also, micelle use primarily for the diagnosis of lymphatic ducts and sentinel lymph nodes received special attention. Notably, the employment of these diagnostic techniques can be considered a significant tool for functionally exploring body systems as well as investigating molecular pathways involved in the disease process. The use of molecular modeling methodologies and computer-aided drug design strategies can also yield valuable information for the rational design and development of novel radiopharmaceuticals.
Resumo:
Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.