972 resultados para Retenção em prótese total


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The success rate of resin-bonded fixed partial dentures is directly related to the adhesive system and the tooth preparation design for good retention. These resin-bonded bridges represent a prosthodontic alternative, based on their costeffectiveness, conservative techniques, and ease of laboratory manufacturing. Through a thorough review of the literature, this study aimed to report on cavity designs, types of materials used, and the advantages and disadvantages of the resin-bonded fixed partial denture. One of significant advantages of the resin-bonded fixed partial dentures is the conservation of the tooth structure, whereas its main disadvantage includes aesthetic limitations, given that the alloy may in fact be visible. Preparation design, cement type, and casting alloy type, as well as surface treatment, are among the factors that influence the longevity of resin-bonded fixed partial dentures. Treatments with resin-bonded fixed partial dentures present a bright outlook regarding the conservation of tooth structures, as well as a high level of success.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: to the purpose of this study was to compare the stress distribution in the peri-implant hard tissue on different attachment systems for mandibular or maxillary implant-retained overdentures. Material and methods: the search for published studies was performed on PubMed/Medline database covering the period of January 2000 to April 2014. The selection of the eligible studies was performed according to including and excluding criteria. Results: a total of 140 studies were screened and according to the search strategy, 21 studies were selected for this review. Eight studies perfomed strain-gauge analysis, 5 evaluated the stress distribution though photoelastic test and 7 performed tridimensional finite element analysis. Only one study in vivo was included. Non-splinted O-rings showed better stress distribution than other bar-clip attachment systems. Conclusions: the present study did not find sufficient evidences regarding the most indicated attachment system for overdentures with better stress distribution for the peri-implant hard tissue. The methodologies analyzed should be complemented with other tests and used as a tool for further clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to review the current scientific literature to discuss the biomechanical behavior and characteristics inherent to both cast post and core and the prefabricated posts used in the practice of restoring endodontically treated teeth. To identify studies of this review, it was performed a detailed and advanced search strategy to the databases PubMed and Medline. It was used as descriptors: endodontically treated teeth, post, core, fiber post and metal post. Inclusion criteria were: clinical trials, randomized controlled trials, in vitro studies, literature reviews and systematic reviews with or without meta-analysis of the last 10 years that addressed the theme. Exclusion criteria were: articles without abstracts, animal studies, articles whose language was not English and articles from journals that do not belong to the Dentistry field. Of a total of 35 articles, after an analysis according to inclusion and exclusion criteria, 23 articles were selected. Most of the current scientific literature indicates that the prefabricated fiber reinforced and ceramic posts should be appointed for endodontically treated teeth that have a minimum height of 2mm ferrule. As for the cast metal cores, along with pre-fabricated metal represent a good prosthetic option, when weakened teeth have to be restored for any reason. Despite the large number of studies, there is still a lack of longterm prospective studies that evaluate the effectiveness of these posts in the treatment of endodontically treated teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetives: Determine the stability of tibial and femoral components of 20 cementless knee arthroplasties with rotating platform. Methods: The 20 patients (20 knees) underwent an analysis of dynamic radiographs with an image amplifier and maneuvers of varus and valgus which were compared to static frontal and lateral radiographs of the knees and analyzed by two experienced surgeons in a double-blind way. Results: We could observe in this study that both methods showed very similar results for the stability of the tibial and femoral components (p<0.001) using the Kappa method for comparison. Conclusion: The tibial component was more unstable in relation to the femoral component in both static and dynamic studies. Level of Evidence IV, Case Series.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Comparar dois métodos de avaliação da estabilidade dos componentes tibial e femoral nas artroplastias de joelho não cimentadas com plataforma rotatória. MÉTODOS: Para isso foram avaliados 20 pacientes (20 joelhos) através de uma análise de radiografias dinâmicas com intensificador de imagem e manobras de estresse em varo e valgo, que foram comparadas com radiografias estáticas em frente e perfil dos joelhos, analisadas por dois cirurgiões experientes, cegos um em relação ao outro. RESULTADOS: Os resultados das análises estáticas e dinâmicas foram comparados e demonstraram forte correlação estatística (p<0,001), utilizando-se o método Kappa de comparação. CONCLUSÃO: O componente tibial mostrou-se mais instável quando comparado com o componente femoral, tanto na análise estática, quanto na dinâmica. Nível de evidência IV, Série de Casos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A curva de retenção da água no solo é um dos principais instrumentos para avaliar a qualidade física dos solos e possibilitar seu manejo adequado. Por meio da Teoria da Capilaridade vários equipamentos foram desenvolvidos para determinar a intensidade com que a água está retida ao solo, porém, pouco se tem dado atenção para verificar se os pressupostos para o real funcionamento da teoria estão sendo atendidos. Um aspecto refere-se ao tamanho da amostra utilizada para determinar a curva de retenção, de modo que haja continuidade dos feixes capilares na amostra e placa porosa. Desta forma, este trabalho propõe avaliar diferentes tamanhos de amostra indeformada para a determinação da curva de retenção. Para isso, coletaram-se amostras em anéis volumétricos cilíndricos de três tamanhos (altura) diferentes (T1 - 0,075 m; T2 - 0,05 m; T3 - 0,025 m;) e mesmo diâmetro interno (0,07 m), dos horizontes diagnósticos de um Latossolo e um Nitossolo em áreas experimentais da Escola Superior de Agricultura Luiz de Queiroz (Esalq/USP), Piracicaba - SP. Realizou-se a caracterização física destes solos, por meio da análise granulométrica, densidade do solo, densidade de partículas, porosidade total e teor de carbono orgânico. As curvas foram determinadas para cada tamanho de amostra, utilizando-se o Funil de Haines, para as tensões 0,5, 1, 4, 6 e 10 kPa, e a Câmara de Pressão de Richards para 33, 100 e 500 kPa. As curvas de retenção foram ajustadas pelo modelo utilizado por van Genuchten. Estimadas as curvas, avaliou-se a distribuição de poros do solo das amostras, determinando-se a curva de frequência acumulada de poros em função do logaritmo do raio e, depois pela diferenciação das equações de ajuste das curvas de retenção, a curva diferencial de frequência acumulada de poros. Os resultados mostram que o Latossolo, por ter textura arenosa no horizonte estudado, não apresentou diferença significativa nas curvas de retenção para os tamanhos das amostras estudadas. Verificou-se pouca modificação na distribuição dos poros deste solo, que possui teor elevado das frações areia fina e muito fina, e desenvolveram papel importante para a retenção de água. O Nitossolo, por sua vez, apresentou diferença significativa da curva obtida pela amostra de menor tamanho (T3), havendo maior retenção de água com a diminuição do tamanho da amostra. Devido a sua textura muito argilosa, o arranjo estrutural deste solo foi diferenciado ao se utilizar as amostras maiores, com provável interrupção e descontinuidade dos feixes capilares. Consequentemente, houve também alteração na distribuição dos poros, com redução dos mesoporos e aumento dos microporos. Desta forma, pode-se concluir que o tamanho da amostra influenciou a curva de retenção da água devido à complexidade estrutural do solo, que provavelmente é diferente nas amostras maiores por causa da continuidade dos feixes capilares, principalmente no Nitossolo. Em outras palavras, quanto menor o tamanho da amostra há menor diferenciação no arranjo de poros, ou seja, maior proximidade da real condição do solo e, assim, uma interpretação da retenção de água \"mais correta\" por meio da Teoria da Capilaridade.