183 resultados para Reoperation
Resumo:
Complete correction of Tetralogy of Fallot, the most common cyanotic congenital heart defect, has now become routine. However, late residual lesions, primarily chronic pulmonary valve insufficiency, may have a negative impact on right-ventricular function, leading to the need for reoperation to insert a competent valve at the right-ventricular outflow. The diagnostic modalities pertaining to the failing right ventricle, the timing for eventual reintervention and the various surgical reconstruction possibilities of the right-ventricular outflow tract are still controversial and evolving, and are reviewed with a brief overview on current trends and future outlooks.
Resumo:
BACKGROUND: Theodor Kocher, surgeon and Nobel laureate, has influenced thyroid surgery all over the world: his treatment for multinodular goiter-subtotal thyroidectomy-has been the "Gold Standard" for more than a century. However, based on a new understanding of molecular growth mechanisms in goitrogenesis, we set out to evaluate if a more extended resection yields better results. METHODS: Four thousand three hundred and ninety-four thyroid gland operations with 5,785 "nerves at risk" were prospectively analyzed between 1972 and 2002. From 1972 to 1990, the limited Kocher resections were performed, and from 1991 to 2002 a more radical resection involving at least a hemithyroidectomy was performed. RESULTS: The incidence of postoperative nerve palsy was 3.6%; in the first study period and 0.9%; in the second (P < 0.001, Fisher's exact). Postoperative hypoparathyroidism decreased from 3.2%; in the first period to 0.64%; in the second (P < 0.01). The rate of reoperation for recurrent disease was 11.1%; from 1972 to 1990 and 8.5%; from 1991 to 2002 (P < 0.01). CONCLUSIONS: Extended resection for multinodular goiter not only significantly reduced morbidity, but also decreased the incidence of operations for recurrent disease. Our findings in a large cohort corroborate the suggestions that Kocher's approach should be replaced by a more radical resection, which actually was his original intention more than 130 years ago.
Resumo:
Morbid obesity (body mass index > 40 kg/m2) is a risk factor for cardiovascular, pulmonary, metabolic, neoplastic, and psychologic sequelae. In the present prospective clinical study 65 patients (11 men, 54 women) underwent vertical banded gastroplasty (Mason procedure) from June 1994 to October 1997. The median age was 41 +/- 5.3 years (range 18-69; n = 65). Preoperative body weight was 135 +/- 23 kg (96-229; n = 65), excess body weight in kg was 75 +/- 6.9 (44-155; n = 65) or in % 126 +/- 10 (78-223; n = 65) and BMI was 49 +/- 7.4 kg/m2 (39-69; n = 65). Mean hospital stay was 9.7 +/- 2.4 days (6-18; n = 65). Hospital mortality was 0% (0/65). Early complications were vomiting (30%) and problems in wound healing (15%; n = 65). Late complications (> 30 days) were incisional hernias (13.8%) and staple-line disruptions (12.3%; n = 65) with a reoperation rate of 23% (15/65). Median follow-up was 15.0 +/- 5.2 months (2-42) with a follow up rate of 100%. Mean weight loss after 12 months was 38.5 +/- 17 kg (30-98; n = 34) (P < 0.0001) and loss of excessive body weight 65 +/- 10% (57-86; n = 34), respectively (P < 0.0001). Cardiovascular risk factors (hypertension, diabetes, hyperlipidemia) were significantly improved within 12 months (n = 34). Vertical banded gastroplasty (Mason procedure)--well established for 20 years--is a good, safe therapy for morbid obesity if strict indications for operation are observed and if there is multidisciplinary long-term follow-up. Comorbid risk factors are considerably reduced and a long-term weight loss of more than 50% can be achieved without the risk of pathological metabolic changes.
Resumo:
OBJECTIVE: The Ross operation remains a controversially discussed procedure, because concern exists regarding late dilatation of the neoaortic root and progressive regurgitation of the autograft valve. We present our early experience with an external reinforcement of the autograft, which is inserted into a prosthetic Dacron graft with an artificial aortic root configuration. This detail should help to prevent neoaortic root dilatation. PATIENTS AND METHODS: Between 2006 and 2007, 12 patients (mean age 16 +/- 38 years; range 15-38 years) underwent a Ross procedure by this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 5), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 9 patients. Balloon valvuloplasty had been performed in 7 patients. Follow-up was performed by clinical and echocardiographic examinations. RESULTS: No early or late deaths occurred in this small series, and freedom from reoperation is 100%. Echocardiographic follow-up confirmed absence of aortic insufficiency in 11 patients after a mean of 11 months (range 2-30 months). In 1 patient, a small asymmetric regurgitation jet was already observed at discharge echocardiography. As expected, no neoaortic root dilatation was observed during follow-up. All patients are in New York Heart Association class I. CONCLUSIONS: The present technique is a simple and reproducible technical step that does not require significant additional time. Inclusion of the autograft within a root prosthesis may be especially indicated in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement.
Resumo:
AIMS: To study if minimally invasive strabismus surgery (MISS) is suitable for rectus muscle reoperations. METHODS: The study presents a series of consecutive patients operated on by the same surgeon at Kantonsspital St Gallen, Switzerland with a novel MISS rectus muscle reoperation technique. Surgery is done by applying two small radial cuts along the muscle insertion. Through the tunnel obtained after muscle separation from surrounding tissue, a recession, advancement or plication is performed. RESULTS: In 62 eyes of 51 patients (age 35.4 (SD 16.3) years) a total of 86 horizontal rectus muscles were reoperated. On the average, the patients had 2.1 strabismus surgeries previously. Preoperative logMAR visual acuity was 0.38 (0.82) compared with 0.37 (0.83) at 6 months (p>0.1). On the first postoperative day, in the primary gaze position conjunctival and lid swelling and redness was hardly visible in 11 eyes, discrete in 15 eyes, moderate in 11 eyes and severe in 15 eyes. One corneal dellen and one corneal erosion occurred, which both quickly resolved. The preoperative deviation at distance for esodeviations (n = 15) of 12.5 (8.5) degrees decreased to 2.6 (7.8) degrees at 6 months (p<0.001). For near, a decrease from 12.0 (10.1) degrees to 2.9 (1.6) degrees was observed (p<0.001). The preoperative deviation at distance for exodeviations (n = 35) of -16.4 (8.5) degrees decreased to -7.9 (6.5) degrees at 6 months (p<0.005). For near, a decrease from -16.5 (11.4) degrees to -2.9 (1.5) degrees was observed (p<0.005). Within the first 6 months, only one patient had a reoperation. At month 6, in four patients a reoperation was planned or suggested by us because of unsatisfactory alignment. No patient experienced persistent diplopia or necessitated a reoperation because of double vision. Stereovision improved at month 6 compared with preoperatively (p<0.01). CONCLUSIONS: The study demonstrates that a small-cut, minimal dissection technique allows to perform rectus muscle reoperations. The MISS technique seems to reduce conjunctival and lid swelling in the direct postoperative period.
Resumo:
BACKGROUND: This study reviews our experience with the Ross procedure in infants and young children. METHODS: From September 1993 to September 2004, 52 children less than 15 years of age underwent a Ross procedure. The patients ranged in age from 4 days to 15 years old (median, 5 years). Fifteen patients (29%) were less than 2 years of age. The predominant indication for the Ross procedure was aortic stenosis. Sixteen patients underwent a Ross-Konno procedure for severe left ventricular outflow tract obstruction. Thirty-four patients had 48 previous interventions. Preoperatively, 6 patients showed severe left ventricular dysfunction, and 2 of the patients required ventilation and inotropic support. Concomitant procedures were performed in 8 patients. Three patients had a mitral valve replacement, 2 patients had a ventricular septal defect closure and an aortic arch reconstruction, 2 patients had aortic arch reconstructions, and 1 patient had resection of a coarctation and a ventricular septal defect closure. RESULTS: Patients were followed up for a median of 43 months (range, 1 to 130). Overall survival was 85% +/- 5% at 1 and 82% +/- 5% at 2, 5, and 10 years. Hospital mortality was 5 of 52 patients (9.6%). All deaths occurred in neonates or infants less than 2 months of age, who needed urgent surgery. Three patients died late of noncardiac causes. At last follow-up, all patients were classified in New York Heart Association functional class I or II. No patient had endocarditis of the autograft or the right ventricular outflow tract replacement. During the follow-up, no event of thrombembolism was observed. No patient required the insertion of a permanent pacemaker. Overall freedom from reoperation is 57% +/- 15% at 10 years. One patient required the replacement of the autograft at 6 months postoperatively. The development of mild aortic insufficiency was observed in 24 patients, and moderate aortic insufficiency in 1 patient during follow-up. Freedom from reoperation for the right ventricular outflow tract replacement is 60% +/- 15% at 10 years. CONCLUSIONS: The Ross procedure represents an attractive approach to aortic valve disease in young children. However, a high early mortality rate has to be considered when performing this procedure in neonates or infants who present in critical preoperative condition.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Preservation of the aortic valve during the repair of acute type A aortic dissection (AADA) is a viable option to prevent lifelong oral anticoagulation. The study aim was to assess aortic valve function following resuspension and supracoronary ascending aortic grafting. METHODS: Among a collective of 210 consecutive patients undergoing surgery for AADA, 140 (66.7%) with resuspension of the aortic valve and supracoronary ascending graft were analyzed. Of these patients, 83 (59.3%) had a complete follow up (mean 61.2 +/- 40.8 months), with 65 of the subgroup (78.3%) being followed by computed tomography scanning and echocardiography. RESULTS: Reoperation due to severe aortic valve regurgitation was required in seven patients (10.8%). The perioperative characteristics were similar in these patients; notably, no significant difference was evident with regards to the aortic annulus diameter and the severity of regurgitation at the time of surgery. The left ventricular mass index was significantly higher in patients requiring reoperation due to aortic valve regurgitation (219.3 +/- 146.6 versus 123.9 +/- 146.6 g/m2; p <0.05). None of the patients died as a result of reoperation. CONCLUSION: The long-term functional results following resuspension of the aortic valve in AADA were very good. A close echocardiographic follow up was necessary, as reoperation of the aortic valve was required in more than 10% of the collective, with an average follow up of five years. Reoperation was mainly related to secondary dilatation of the aortic root.
Resumo:
Introduction: Dehiscence of the suture line of an anastomosis can lead to reoperation, temporary or permanent stoma, and even sepsis or death. Few techniques for the laboratory training of tubular anastomosis use ex-vivo animal tissues. We describe a novel model that can be used in the laboratory for the training of anastomosis in tubular tissues and objectively assess any anastomotic leak. [See PDF for complete abstract]
Resumo:
OBJECTIVE To analyse the results after elective open total aortic arch replacement. METHODS We analysed 39 patients (median age 63 years, median logistic EuroSCORE 18.4) who underwent elective open total arch replacement between 2005 and 2012. RESULTS In-hospital mortality was 5.1% (n = 2) and perioperative neurological injury was 12.8% (n = 5). The indication for surgery was degenerative aneurysmal disease in 59% (n = 23) and late aneurysmal formation following previous surgery of type A aortic dissection in 35.9% (n = 14); 5.1% (n = 2) were due to anastomotical aneurysms after prior ascending repair. Fifty-nine percent (n = 23) of the patients had already undergone previous proximal thoracic aortic surgery. In 30.8% (n = 12) of them, a conventional elephant trunk was added to total arch replacement, in 28.2% (n = 11), root replacement was additionally performed. Median hypothermic circulatory arrest time was 42 min (21-54 min). Selective antegrade cerebral perfusion was used in 95% (n = 37) of patients. Median follow-up was 11 months [interquartile range (IQR) 1-20 months]. There was no late death and no need for reoperation during this period. CONCLUSIONS Open total aortic arch replacement shows very satisfying results. The number of patients undergoing total arch replacement as a redo procedure and as a part of a complex multisegmental aortic pathology is high. Future strategies will have to emphasize neurological protection in extensive simultaneous replacement of the aortic arch and adjacent segments.
Resumo:
BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.
Resumo:
OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events. RESULTS The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation. CONCLUSIONS Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.
Resumo:
OBJECTIVES Loeys-Dietz syndrome (LDS) is characterized by acute aortic dissection (AAD) at aortic diameters below thresholds for intervention in patients with Marfan syndrome (MFS). The aim was to evaluate the outcome of LDS patients primarily treated as having MFS. METHODS We analysed 68 consecutive patients who underwent surgery between 1995 and 2007 under the assumption of having MFS before retrospectively being screened for LDS when genetic testing became available. These patients were followed up until 2013, and underwent a total of 115 aortic surgeries. RESULTS Genetic testing was performed in 76% of the patients. Sixty per cent of these patients were positive for FBN1 mutations associated with MFS, 20% had no FBN1 mutation and 17% harboured TGFBR1/2 mutations associated with LDS. Mean follow-up was 12.7 ± 7 years. All-cause 30-day, 6-month and 1-year mortality rates were 2.9, 4.4 and 7.3%, respectively. Interestingly, initial presentation with AAD did not differ between LDS and MFS (33 vs 37%, P = 0.48) nor did long-term mortality compared with MFS patients (11 vs 16%, P = 1.0) or within MFS subgroups (FBN1 positive 13%, P = 1.0; FBN1 negative 10%, P = 1.0; not tested 25%, P = 0.62). There was no difference in the need for secondary total arch replacement between LDS and MFS patients (11 vs 14%, P = 1.0), nor within MFS subgroups (FBN1 positive 16%, P = 1.0; FBN1 negative 10%, P = 1.0; not tested 13%, P = 1.0). Total aortic replacement became necessary in 22% of LDS compared with 12% of MFS patients (P = 0.6) and did not differ significantly between MFS subgroups. CONCLUSIONS Although early surgical intervention in LDS is warranted to avoid AAD, the current data suggest that once the diseased segment is repaired, there seems to be no additional burden in terms of mortality or reoperation rate compared with that in MFS patients, with or without confirmed FBN1 mutation.
Resumo:
OBJECTIVES Valve-sparing root replacement (VSRR) is thought to reduce the rate of thromboembolic and bleeding events compared with aortic root replacement using a mechanical aortic root replacement (MRR) with a composite graft by avoiding oral anticoagulation. But as VSRR carries a certain risk for subsequent reinterventions, decision-making in the individual patient can be challenging. METHODS Of 100 Marfan syndrome (MFS) patients who underwent 169 aortic surgeries and were followed at our institution since 1995, 59 consecutive patients without a history of dissection or prior aortic surgery underwent elective VSRR or MRR and were retrospectively analysed. RESULTS VSRR was performed in 29 (David n = 24, Yacoub n = 5) and MRR in 30 patients. The mean age was 33 ± 15 years. The mean follow-up after VSRR was 6.5 ± 4 years (180 patient-years) compared with 8.8 ± 9 years (274 patient-years) after MRR. Reoperation rates after root remodelling (Yacoub) were significantly higher than after the reimplantation (David) procedure (60 vs 4.2%, P = 0.01). The need for reinterventions after the reimplantation procedure (0.8% per patient-year) was not significantly higher than after MRR (P = 0.44) but follow-up after VSRR was significantly shorter (P = 0.03). There was neither significant morbidity nor mortality associated with root reoperations. There were no neurological events after VSRR compared with four stroke/intracranial bleeding events in the MRR group (log-rank, P = 0.11), translating into an event rate of 1.46% per patient-year following MRR. CONCLUSION The calculated annual failure rate after VSRR using the reimplantation technique was lower than the annual risk for thromboembolic or bleeding events. Since the perioperative risk of reinterventions following VSRR is low, patients might benefit from VSRR even if redo surgery may become necessary during follow-up.
Resumo:
PURPOSE OF REVIEW There is controversy regarding the optimal choice of prosthetic valves in patients less than 65 years of age requiring mitral valve replacement (MVR). Recently, trends for valve replacement are moving towards biological prosthesis also in younger patients, which is justified by the fact that a later valve-in-valve procedure is feasible in the case of degeneration of the tissue valve. This strategy is increasingly recommended in aortic valve surgery but is questionable for MVR. The purpose of this review is to evaluate current guidelines and analyse evidence for biological MVR in patients under 65 years. RECENT FINDINGS There are differences between guidelines of the American Heart Association and those of the European Society of Cardiology concerning the choice of prostheses in patients undergoing MVR. Although the European Society of Cardiology recommends a mechanical mitral valve in patients under 65 years of age, the American Heart Association does not provide detailed advice for these patients. Mitral valve replacement with biological valves in patients under 65 years is associated with higher rates of reoperation due to structural valve deterioration. In addition, several studies showed a decreased survival after biological MVR. SUMMARY Evidence for biological MVR in patients less than 65 years without comorbidities or contraindication for oral anticoagulation does not exist. Recommendations for patients less than 65 years of age should not be blurred by current 'en-vogue' methods for promising but not yet proven valve-in-valve strategies.
Resumo:
OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.