820 resultados para Reliability and safeties
Resumo:
One of the foremost design considerations in microelectronics miniaturization is the use of embedded passives which provide practical solution. In a typical circuit, over 80 percent of the electronic components are passives such as resistors, inductors, and capacitors that could take up to almost 50 percent of the entire printed circuit board area. By integrating passive components within the substrate instead of being on the surface, embedded passives reduce the system real estate, eliminate the need for discrete and assembly, enhance electrical performance and reliability, and potentially reduce the overall cost. Moreover, it is lead free. Even with these advantages, embedded passive technology is at a relatively immature stage and more characterization and optimization are needed for practical applications leading to its commercialization.This paper presents an entire process from design and fabrication to electrical characterization and reliability test of embedded passives on multilayered microvia organic substrate. Two test vehicles focusing on resistors and capacitors have been designed and fabricated. Embedded capacitors in this study are made with polymer/ceramic nanocomposite (BaTiO3) material to take advantage of low processing temperature of polymers and relatively high dielectric constant of ceramics and the values of these capacitors range from 50 pF to 1.5 nF with capacitance per area of approximately 1.5 nF/cm(2). Limited high frequency measurement of these capacitors was performed. Furthermore, reliability assessments of thermal shock and temperature humidity tests based on JEDEC standards were carried out. Resistors used in this work have been of three types: 1) carbon ink based polymer thick film (PTF), 2) resistor foils with known sheet resistivities which are laminated to printed wiring board (PWB) during a sequential build-up (SBU) process and 3) thin-film resistor plating by electroless method. Realization of embedded resistors on conventional board-level high-loss epoxy (similar to 0.015 at 1 GHz) and proposed low-loss BCB dielectric (similar to 0.0008 at > 40 GHz) has been explored in this study. Ni-P and Ni-W-P alloys were plated using conventional electroless plating, and NiCr and NiCrAlSi foils were used for the foil transfer process. For the first time, Benzocyclobutene (BCB) has been proposed as a board level dielectric for advanced System-on-Package (SOP) module primarily due to its attractive low-loss (for RF application) and thin film (for high density wiring) properties.Although embedded passives are more reliable by eliminating solder joint interconnects, they also introduce other concerns such as cracks, delamination and component instability. More layers may be needed to accommodate the embedded passives, and various materials within the substrate may cause significant thermo -mechanical stress due to coefficient of thermal expansion (CTE) mismatch. In this work, numerical models of embedded capacitors have been developed to qualitatively examine the effects of process conditions and electrical performance due to thermo-mechanical deformations.Also, a prototype working product with the board level design including features of embedded resistors and capacitors are underway. Preliminary results of these are presented.
Resumo:
Reliability and availability have long been considered twin system properties that could be enhanced by distribution. Paradoxically, the traditional definitions of these properties do not recognize the positive impact of recovery as distinct from simple repair and restart on reliability, nor the negative effect of recovery, and of internetworking of clients and servers, on availability. As a result of employing the standard definitions, reliability would tend to be underestimated, and availability overestimated. We offer revised definitions of these two critical metrics, which we call service reliability and service availability, that improve the match between their formal expression, and intuitive meaning. A fortuitous advantage of our approach is that the product of our two metrics yields a highly meaningful figure of merit for the overall dependability of a system. But techniques that enhance system dependability exact a performance cost, so we conclude with a cohesive definition of performability that rewards the system for performance that is delivered to its client applications, after discounting the following consequences of failure: service denial and interruption, lost work, and recovery cost.
Resumo:
Introduction: Le but de l’étude était d’examiner l’effet des matériaux à empreintes sur la précision et la fiabilité des modèles d’études numériques. Méthodes: Vingt-cinq paires de modèles en plâtre ont été choisies au hasard parmi les dossiers de la clinique d’orthodontie de l’Université de Montréal. Une empreinte en alginate (Kromopan 100), une empreinte en substitut d’alginate (Alginot), et une empreinte en PVS (Aquasil) ont été prises de chaque arcade pour tous les patients. Les empreintes ont été envoyées chez Orthobyte pour la coulée des modèles en plâtre et la numérisation des modèles numériques. Les analyses de Bolton 6 et 12, leurs mesures constituantes, le surplomb vertical (overbite), le surplomb horizontal (overjet) et la longueur d’arcade ont été utilisés pour comparaisons. Résultats : La corrélation entre mesures répétées était de bonne à excellente pour les modèles en plâtre et pour les modèles numériques. La tendance voulait que les mesures répétées sur les modèles en plâtre furent plus fiables. Il existait des différences statistiquement significatives pour l’analyse de Bolton 12, pour la longueur d’arcade mandibulaire, et pour le chevauchement mandibulaire, ce pour tous les matériaux à empreintes. La tendance observée fut que les mesures sur les modèles en plâtre étaient plus petites pour l’analyse de Bolton 12 mais plus grandes pour la longueur d’arcade et pour le chevauchement mandibulaire. Malgré les différences statistiquement significatives trouvées, ces différences n’avaient aucune signification clinique. Conclusions : La précision et la fiabilité du logiciel pour l’analyse complète des modèles numériques sont cliniquement acceptables quand on les compare avec les résultats de l’analyse traditionnelle sur modèles en plâtre.
Resumo:
The service quality of any sector has two major aspects namely technical and functional. Technical quality can be attained by maintaining technical specification as decided by the organization. Functional quality refers to the manner which service is delivered to customer which can be assessed by the customer feed backs. A field survey was conducted based on the management tool SERVQUAL, by designing 28 constructs under 7 dimensions of service quality. Stratified sampling techniques were used to get 336 valid responses and the gap scores of expectations and perceptions are analyzed using statistical techniques to identify the weakest dimension. To assess the technical aspects of availability six months live outage data of base transceiver were collected. The statistical and exploratory techniques were used to model the network performance. The failure patterns have been modeled in competing risk models and probability distribution of service outage and restorations were parameterized. Since the availability of network is a function of the reliability and maintainability of the network elements, any service provider who wishes to keep up their service level agreements on availability should be aware of the variability of these elements and its effects on interactions. The availability variations were studied by designing a discrete time event simulation model with probabilistic input parameters. The probabilistic distribution parameters arrived from live data analysis was used to design experiments to define the availability domain of the network under consideration. The availability domain can be used as a reference for planning and implementing maintenance activities. A new metric is proposed which incorporates a consistency index along with key service parameters that can be used to compare the performance of different service providers. The developed tool can be used for reliability analysis of mobile communication systems and assumes greater significance in the wake of mobile portability facility. It is also possible to have a relative measure of the effectiveness of different service providers.
Resumo:
In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
This paper addresses the functional reliability and the complexity of reconfigurable antennas using graph models. The correlation between complexity and reliability for any given reconfigurable antenna is defined. Two methods are proposed to reduce failures and improve the reliability of reconfigurable antennas. The failures are caused by the reconfiguration technique or by the surrounding environment. These failure reduction methods proposed are tested and examples are given which verify these methods.
Resumo:
Background and Study Aim: The grip strength endurance is important for Brazilian Jiu-Jitsu (BJJ). Thus, the aims of this study were: a) to test the reliability of two kimono grip strength tests named maximum static lift (MSL) and maximum number of repetitions (MNR) and b) to examine differences between elite and non-elite BJJ players in these tests. Material/Methods: Thirty BJJ players participated into two phases: "A" to test reliability and "B" to compare elite and non-elite. In phase A, twenty participants performed the MSL and, 15 min later, the MNR in two occasions with 24-h interval. In phase B, ten other BJJ practitioners (non-elite) and ten athletes (elite) performed the same tests. The intraclass correlation coefficient (ICC) two way fixed model (3,1), Bland-Altman plot and the limits of agreement were used to test reliability, correlation between the tests were evaluated by Pearson correlations and independent T test (P<0.05) was utilized to compare elite vs. non-elite. Results: The ICC was high for repeated measurements on different days of phase A (MSL: r=0.99 and MNR: r=0.97). Limits of agreement for time of suspension were -6.9 to 2.4-s, with a mean difference of -2.3 s (CI: -3.3 to -1.2-s), while for number of repetitions the limits of agreement were -2.9 to 2.3-rep, with a mean difference of -0.3-rep (CI: -0.9 to 0.3-rep). In phase B, elite presented better performance for both tests (P<0.05) compared to non-elite (56 +/- 10-s vs. 37 +/- 11-s in MSL and 15 +/- 4-rep vs. 8 +/- 3-rep in MNR). Moderate correlation were found between MSL and MNR for absolute values during test (r=0.475; p=0.034), and retest phases (r=0.489; p=0.029), while moderate and high correlations in the test (r=0.615; p=0.004) and retest phases (r=0.716; p=0.001) were found for relative values, respectively. Conclusions: These proposed tests are reliable and both static and dynamic grip strength endurance tests seem to differentiate BJJ athletes from different levels.
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
PURPOSE Stress urinary incontinence (SUI) affects women of all ages including young athletes, especially those involved in high-impact sports. To date, hardly any studies are available testing pelvic floor muscles (PFM) during sports activities. The aim of this study was the description and reliability test of six PFM electromyography (EMG) variables during three different running speeds. The secondary objective was to evaluate whether there was a speed-dependent difference between the PFM activity variables. METHODS This trial was designed as an exploratory and reliability study including ten young healthy female subjects to characterize PFM pre-activity and reflex activity during running at 7, 9 and 11 km/h. Six variables for each running speed, averaged over ten steps per subject, were presented descriptively, tested regarding their reliability (Friedman, ICC, SEM, MD) and speed difference (Friedman). RESULTS PFM EMG variables varied between 67.6 and 106.1 %EMG, showed no systematic error and were low for SEM and MD using the single value model. Applying the average model over ten steps, ICC (3,k) were >0.75 and SEM and MD about 50 % lower than for the single value model. Activity was found to be highest in 11 km/h. CONCLUSION EMG variables showed excellent ICC and very low SEM and MD. Further studies should investigate inter-session reliability and PFM reactivity patterns of SUI patients using the average over ten steps for each variable as it showed very high ICC and very low SEM and MD. Subsequently, longer running distances and other high-impact sports disciplines could be studied.
Resumo:
Background. Not only has obesity played a role in Texas adults but it is also becoming a large issue among low-income Latino children. In Latino children between 2-5 years of age, the Pediatric Nutrition Surveillance data in 1997 found the prevalence of obesity was 12 percent, highest among all ethnic groups. Children learn what and how to eat from their environment. Despite many mothers being working mothers they are still the principal caregivers and source of influence on their toddler's diet. Self-efficacy, a concept created by Albert Bandura, one's belief that one is capable of performing a behavior needed to reach an intended goal, is increasingly becoming important in nutrition and health education. This study is important to understand the degree of impact that a mother's self-efficacy will have on a child's diet. This is useful knowing if influencing a mother's self-efficacy could improve a child's diet to prevent certain public health issues such as obesity and diabetes. The purpose of this study was to examine nutrition self-efficacy of Latina mothers, focusing on sweets and beverage and if their self-efficacy impacted their child's diet. Methods. The data was collected during July-September 2008. Mothers were recruited from two federally qualified San Antonio health centers. In order to qualify, participants had to be Hispanic with children of toddler age. Mothers were informed of incentives available upon completion. The interview consisted of demographic info, a set of five self-efficacy questions repeated at completion, testing reliability and a 24-hour food recall diary asked of the participant's child's diet. Results. There were 225 mothers who participated between both clinics. The Crohnbach alpha scores for the two different times the self-efficacy questions were asked were .44 corresponding to the first time and .49 for the second time. The three most common beverages reported were milk, juice, and water. The mothers who met or gave their child more milk than recommended by the scientific community, 800mg of calcium/3 cups (24oz) set, had a higher self-efficacy score than those who did not meet the standard at all. Mothers who gave their children more juice than the standard recommends, 4-6oz for children 1-6 years of age, had slightly higher self-efficacy scores than mother's who simply met the standard. In general, the lower the mother's self-efficacy, the more sweets they gave their child and vice versa. Conclusion. This study's Kappa values were adequate and this research showed that Latina mothers did in fact have high self-efficacy. In general some of the children's diets did not reflect the current scientific nutrition recommendations. In order to improve self-efficacy and have an impact on children's diets, the scientific community has a responsibility to make recommendations that are easily understood and can be put into practice. The public health community needs to ensure that we encourage those we serve to be more active in their health and educate them about what constitutes good health and nutrition for both themselves and their children.^
Resumo:
The Surgeon General recommends preschoolers 3-5 years old accumulate 60 minutes of moderate-to-vigorous physical activity (MVPA) per day. However, there is limited data measuring physical activity (PA) and MVPA amongst this population. The purpose of this cross-sectional study is to determine the validity, reliability, and feasibility of using MVP 4 Function Walk4Life digital pedometers (MVP-4) in measuring MVPA among preschoolers using the newly modified direct observational technique, System for Observing Fitness Instruction Time-Preschool Version (SOFIT-P) as the gold standard. An ethnically diverse population of 3-5 year old underserved children were recruited from two Harris County Department of Education (HCDE) Head Start centers. For 2 days at baseline and 2 days at post-test, 75 children enrolled wore MVP-4 pedometers for approximately 6-hours per observation day and were observed using SOFIT-P during predominantly active times. Statistical analyses used Pearson "r" correlation coefficients to determine mean minutes of PA and MVPA, convergent and criterion validity, and reliability. Significance was set at p = <0.05. Feasibility was determined through process evaluation information collected during this study via observations from data collectors and teacher input. Results show mean minutes of PA and MVPA ranged between 30-42 and 11-14 minutes, respectively. Convergent validity comparing BMI percentiles with MVP-4 PA outcomes show no significance at pre-test; however, each measurement at post-test showed significance for MVPA (p = 0.0247, p = 0.0056), respectively. Criterion validity comparing percent MVPA time between SOFIT-P and MVP-4 pedometers was determined; however, results deemed insufficient due to inconsistency in observation times while using the newly developed SOFIT-P. Reliability measures show no significance at pre-test, yet show significant results for all PA outcomes at post-test (p = 0.001, p = 0.001, p = 0.0010, p = 0.003), respectively. Finally, MVP-4 pedometers lacked feasibility due to logistical barriers in design. Researchers feel the significant results at post-test are secondary to increased familiarity and more accurate placement of pedometers across time. Researchers suggest manufacturers of MVP-4 pedometers further modify the instrument for ease of use with this population, following which future studies ought to determine validity using objective measures or all-day direct observation techniques.^
Resumo:
The purpose of this study was to analyze the internal consistency and the external and structure validity of the 12-Item General Health Questionnaire (GHQ-12) in the Spanish general population. A stratified sample of 1001 subjects, ages between 25 and 65 years, taken from the general Spanish population was employed. The GHQ-12 and the Inventory of Situations and Responses of Anxiety-ISRA were administered. A Cronbach’s alpha of .76 (Standardized Alpha: .78) and a 3-factor structure (with oblique rotation and maximum likelihood procedure) were obtained. External validity of Factor I (Successful Coping) with the ISRA is very robust (.82; Factor II, .70; Factor III, .75). The GHQ-12 shows adequate reliability and validity in the Spanish population. Therefore, the GHQ-12 can be used with efficacy to assess people’s overall psychological well-being and to detect non-psychotic psychiatric problems. Additionally, our results confirm that the GHQ-12 can best be thought of as a multidimensional scale that assesses several distinct aspects of distress, rather than just a unitary screening measure.
Resumo:
"Formerly NPC 250-1."