816 resultados para Reducing energy consumption


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The European Union set the ambitious target of reducing energy consumption by 20% within 2020. This goal demands a tremendous change in how we generate and consume energy and urgently calls for an aggressive policy on energy efficiency. Since 19% of the European electrical energy is used for lighting, considerable savings can be achieved with the development of novel and more efficient lighting systems. In this thesis, accomplished in the frame of the EU project CELLO, I report some selected goals we achieved attempting to develop highly efficient, flat, low cost and flexible light sources using Light-Emitting Electrochemical Cells (LECs), based on ionic cyclometalated iridium(III) complexes. After an extensive introduction about LECs and solid-state lighting in general, I focus on the research we carried out on cyclometalated iridium(III) complexes displaying deep-blue emission, which has turned out to be a rather challenging task. In order to demonstrate the wide versatility of this class of compounds, I also report a case in which some tailored iridium(III) complexes act as near-infrared (NIR) sources. In fact, standard NIR emitting devices are typically expensive and, also in this case, LECs could serve as low-cost alternatives in fields were NIR luminescence is crucial, such as telecommunications and bioimaging. Since LECs are based on only one active material, in the last chapter I stress the importance of an integrated approach toward the right selection of suitable emitters not only from the photophysical, but also from the point of view of material science. An iridium(III) complex, once in the device, is interacting with ionic liquids, metal cathodes, electric fields, etc. All these interactions should be taken in to account if Europe really wants to implement more efficient lighting paradigms, generating light beyond research labs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La envolvente de la edificación es la responsable de equilibrar el intercambio energético entre el interior y el exterior, por lo tanto cualquier actuación encaminada a la reducción del consumo energético ha de establecer, como uno de sus objetivos prioritarios, la mejora del comportamiento de la misma. Las edificaciones anteriores a 1940 constituyen la mayor parte de las existentes en áreas rurales y centros urbanos. En ellas, la repercusión de la fachada sobre las transmitancias globales pone de manifiesto la necesidad de intervención. Sin embargo, su elevada inercia térmica y los importantes saltos térmicos característicos de gran parte de España plantean la importancia de que aquélla se efectúe por el exterior. A tal respecto, la falta de disponibilidad de espesor suficiente para implantar sistemas tipo SATE deriva en que, frecuentemente, la única solución viable sea la de aislar por el interior perdiendo con ello la capacidad de acumulación térmica del muro y con el asociado riesgo de condensaciones. La amplia tradición en el empleo de revestimientos, especialmente en base de cal, permiten que éstos sean utilizados no sólo como elemento estético o de protección de la obra de fábrica antigua sino también para la mejora del comportamiento térmico del soporte, si se aprovecha el mecanismo de transmisión térmica por radiación. Éste es el objetivo de la presente Tesis Doctoral en la que se estudia la modificación de las propiedades radiantes de los morteros de revestimiento para la mejora de la eficiencia energética de las construcciones históricas, principalmente las constituidas por muros monolíticos, aunque podría ser de aplicación a otro tipo de construcciones compuestas por diversas capas. Como punto de partida, se estudió y revisó la documentación disponible sobre las investigaciones de las tres áreas científico-tecnológicas que convergen en la Tesis Doctoral: rehabilitación, material y comportamiento térmico, a partir de lo cual se comprobó la inexistencia de estudios similares al objeto de la presente Tesis Doctoral. Complementariamente, se analizaron los revestimientos en lo concerniente a los materiales que los constituyen, la composición de las mezclas y características de cada una de las capas así como al enfoque que, desde el punto de vista térmico, se estimaba más adecuado para la obtención de los objetivos propuestos. Basándonos en dichos análisis, se preseleccionaron ochenta materiales que fueron ensayados en términos de reflectancia y emisividad para elegir cuatro con los que se continuó la investigación. Éstos, junto con la cal elegida para la investigación y el árido marmóreo característico de la última capa de revestimiento, fueron caracterizados térmicamente, de forma pormenorizada, así como química y físicamente. Los fundamentos teóricos y los estudios preliminares desarrollados con distintos materiales, en estado fresco y endurecido, fueron empleados en la dosificación de componentes de las mezclas, en dos proporciones distintas, para el estudio del efecto del agregado. Éstas se ensayaron en estado fresco, para comprobar su adecuación de puesta en obra y prever su VI adherencia al soporte, así como en estado endurecido a 28 y 90 días de curado, para conocer las propiedades que permitieran prever su compatibilidad con aquél y estimar el alcance de la reducción de transferencias térmicas lograda. Además, se estudiaron las características generales de las mezclas que sirvieron para establecer correlaciones entre distintas propiedades y entender los resultados mecánicos, físicos (comportamiento frente al agua) y energéticos. Del estudio conjunto de las distintas propiedades analizadas se propusieron dos mezclas, una blanca y otra coloreada, cuyas características permiten garantizar la compatibilidad con la obra de fábrica antigua, desde el punto de vista físico y mecánico, y preservar la autenticidad de los revestimientos, en cuanto a la técnica de aplicación tradicional en sistemas multicapa. El comportamiento térmico de las mismas, sobre una obra de fábrica de 40 cm de espesor, se estimó, en estado estacionario y pseudo-transitorio, demostrándose reducciones del flujo térmico entre 16-48%, en condiciones de verano, y entre el 6-11%, en invierno, en función de la coloración y de la rugosidad de la superficie, en comparación con el empleo de la mezcla tradicional. Por lo que, se constata la viabilidad de los materiales compuestos propuestos y su adecuación al objetivo de la investigación. VII ABSTRACT The envelope is responsible for balancing the energy exchange between the inside and outside in buildings. For this reason, any action aimed at reducing energy consumption must establish, as one of its key priorities, its improvement. In rural areas and urban centers, most of the constructions were built before 1940. In them, the impact of the façade on the global transmittance highlights the need for intervention. However, its high thermal inertia and fluctuation of temperatures in the majority of Spain bring up that it should be placed outside the insulation. In this regard, the lack of availability of enough thickness to implement systems such as ETICS results in that often the only viable solution is to isolate the interior, losing thereby the wall’s heat storage capacity with the associated risk of condensation. The tradition in the use of renders, especially lime-based, allows us to use them not only as an aesthetic element or to protect the ancient masonry, but also for improved thermal performance of the support by taking advantage of the heat transfer mechanism by radiation. This is the aim of this Doctoral Thesis in which the modification of the radiative properties of lime mortars for renders to improve the energy efficiency of historic buildings, mainly composed of monolithic walls, is studied, although it could be applied to other structures composed of several layers. As a starting point, the available literature in the three scientific-technological areas that converge at the Doctoral Thesis: rehabilitation, material and thermal behaviour, was reviewed, and confirmed the absence of researches similar to this Doctoral Thesis. Additionally, the renders were studied with regard to the materials that constitute them, the composition of the mixtures and the characteristics of each layer, as well as to the approach which, from a thermal point of view, was deemed the most suitable for achieving the objectives sets. Based on thre aforementioned analysis, eighty materials tested in terms of reflectance and emissivity were pre-selected, to choose four with which the research was continued. Common marble sand, used in the last layer of the renders, together with the appointed materials and hydrated lime were characterized thermally, in detail, as well as chemically and physically. The theoretical bases and preliminary studies with different materials, in fresh and hardened state, were used in the dosage of the composition of the mixtures. In order to study their effect they were used in two different proportions, that is, ten mixtures in total. These were tested in their fresh state to evaluate their setting-up suitability and foresee their adhesion to the support, as well as in their hardened state, at 28 and 90 days of curing, to establish the properties which enabled us to anticipate their compatibility with the old masonry walls and estimate the scope of the reduction of heat transfers achieved. In addition, the general characteristics of the mixtures used to establish correlations and to understand the mechanical, physical and energy results were studied. Two mixtures, one white and one colored, were proposed as the result of the different properties analysed, whose characteristics allow the guarantee of mechanical and physical compatibility VIII with the old masonry and preserve the authenticity of the renders. The thermal behavior of both, applied on a masonry wall 40 cm thick, was estimated at a steady and pseudo-transient state, with heat flow reductions between 16-48% during summertime and 6-11% during wintertime, depending on the color and surface roughness, compared to the use of the traditional mixture. So, the viability of the proposed composite materials and their fitness to the aim of the research are established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reducing energy consumption and eliminating wastage are among the main goals of the European Union (EU) [2]. In order to satisfy all challenges arising from the Kyoto protocol, improving energy efficiency is a very important factor to take into account. There is significant potential for reducing consumption with cost-effective measures. Some studies show that 40% of our energy is consumed in buildings, and the EU has introduced legislation that aims to ensure that less energy is consumed in this way in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La principal motivación para la elección del tema de la tesis es nuestra realidad energética y ambiental. Y más específicamente, la necesidad urgente de dar una respuesta a esta realidad desde el sector de la edificación. Por lo que, el trabajo parte de la búsqueda de soluciones pasivas que ayuden a la reducción del consumo energético y de las emisiones de C02 de los edificios, tanto nuevos como existentes. El objeto de estudio son aplicaciones innovadoras, basadas en el uso de materiales reactivos, con un efecto térmico de memoria bidireccional. La energía es un elemento imprescindible para el desarrollo. Sin embargo, el modelo energético predominante, basado principalmente en la utilización de combustibles de origen fósil, es uno de los importantes responsables del deterioro ambiental que sufre el planeta. Además, sus reservas son limitadas y están concentradas en unas pocas regiones del mundo, lo que genera problemas de dependencia, competitividad y de seguridad de suministro. Dado el gran potencial de ahorro energético del sector de la edificación, la Unión Europea en sus directivas enfatiza la necesidad de mejorar la eficiencia energética de los edificios. Añadiendo, además, la obligatoriedad de desarrollar edificios “energía casi nula”, cuyo prerrequisito es tener un muy alto rendimiento energético. En España, los edificios son responsables del 31% del consumo de energía primaria. La mayor parte de este consumo se relaciona a la utilización de sistemas activos de acondicionamiento. Una medida efectiva para reducir la demanda es mejorar la envolvente. Sin embargo, hay que buscar estrategias adicionales para aumentar aún más la eficiencia de los edificios nuevos y existentes. Para los climas de España, el uso de la inercia térmica ha probado ser una estrategia válida. Sin embargo, su funcionamiento está vinculado al peso y al volumen de los materiales utilizados. Esto limita sus posibilidades en la rehabilitación energética y en los nuevos edificios basados en la construcción ligera. Una alternativa es el uso de aplicaciones de almacenamiento térmico por calor latente, utilizando materiales de cambio de fase (PCM). Los PCM son sustancias con un muy alto calor de fusión, capaces de almacenar una gran cantidad de energía térmica sin requerir aumentos significativos de peso o volumen. Estas características los hacen idóneos para reducir el consumo relacionado con el acondicionamiento térmico, en edificios nuevos y existentes. En la parte preliminar de la investigación, se encontró que para lograr un aprovechamiento óptimo de las aplicaciones con PCM es necesario tener un conocimiento profundo de su funcionamiento y de las variables del sistema. De ahí que el objetivo principal de la presente tesis sea: establecer las bases para la optimizatión integral de las aplicaciones con almacenamiento de energía térmica por calor latente, identificando y validando sus variables más relevantes. La investigación consta de tres partes. La primera, documental, sistematizando y jerarquizando la información científica publicada; la segunda, numérica, basada en un análisis paramétrico de una aplicación con PCM, utilizando simulaciones térmicas; y la tercera, experimental, monitorizando el funcionamiento térmico y energético de diferentes aplicaciones con PCM en módulos a escala real. Los resultados brindan un más profundo entendimiento del funcionamiento de las aplicaciones evaluadas. Han permitido identificar sus variables relevantes, cuantificar su influencia, y determinar condiciones óptimas para su utilización así como situaciones en las que sería muy difícil justificar su uso. En el proceso, se realizó la caracterización térmica y energética de aplicaciones con PCM, tanto opacas como traslúcidas. Además, se ha encontrado que las aplicaciones con PCM son capaces de aumentar la eficiencia energética inclusive en recintos con diseños optimizados, demostrando ser una de las estrategias adecuadas para lograr el muy alto desempeño energético requerido en los edificios energía nula. ABSTRACT The main motivation for choosing the theme of the thesis is our energy and environmental reality. And more specifically, the urgent need to respond to this reality from the building sector. This is why, the work start with the search of passive solutions that help reduce energy consumption and C02 emissions of buildings, in both new and existing ones. The object of study is innovative applications based on the use of responsive materials, with bidirectional thermal memory. Energy is an essential element for development. However, the predominant energy model, based primarily on the use of fossil fuels, is one of the major responsible for the environmental deterioration of the planet, the cause of most of the CO2 emissions. Furthermore, reserves of fossil fuels are limited and are concentrated in a few regions of the world, which creates issues related to dependency, competitiveness, and security of supply. Given the large potential for energy savings in the building sector, the European Union in its directives emphasizes the need to improve energy efficiency in buildings. Also, adding the obligation to develop "nearly zero energy" buildings, whose first prerequisite is to achieve a very high energy efficiency. In Spain, buildings are responsible for 31% of primary energy consumption and most of this consumption is related to the used of HVAC systems. One of the most effective measures to reduce demand is to improve the envelope. However, it is necessary to look for additional strategies to further increase the efficiency of new and existing buildings. For the predominant climates in Spain, use of the thermal inertia may be a valid strategy. Nevertheless, its operation is linked to weight and volume of the materials used. This limits their possibilities in the existing buildings energy retrofitting and in the new buildings based on lightweight construction. An alternative is the use of latent heat thermal energy storage applications (LHTES), using phase change materials (PCM). PCM are substances with a high heat of fusion, capable of storing a large amount of thermal energy without requiring significant increases in weight or volume. These features make them ideal for reducing energy consumption associated with thermal conditioning in both new and existing buildings. In the preliminary part of the investigation, it was found that to get optimum utilization of the PCM applications is needed to have a deep understanding of its operation and, in particular, how the system variables affect its performance. Hence, the main objective of this thesis is: to establish the basis for the integral optimization of applications with latent heat thermal energy storage, identifying and validating the most relevant variables. The research comprises of three parts. The first, documentary, systematizing and prioritizing published scientific information. The second, numeric, based on a parametric analysis of an application PCM using thermal simulations. The third, experimental, monitoring the thermal and energy performance of different applications with PCM on real scale test cells. The results provide a complete understanding of the functioning of the evaluated LHTES application. They have allowed to identify their relevant variables, quantify their influence and determine optimum conditions for use as well as situations where it would be very difficult to justify its use. In the process, it was carried out the power and thermal characterization of various opaque and translucent PCM applications. Furthermore, it has been found that applications with PCM can increase the energy efficiency, even in buildings with optimized designs; proving to be one of the appropriate measures to achieve the high energy performance required in zero energy buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The urban microclimate plays an important role in building energy consumption and thermal comfort in outdoor spaces. Nowadays, cities need to increase energy efficiency, reduce pollutant emissions and mitigate the evident lack of sustainability. In light of this, attention has focused on the bioclimatic concepts use in the urban development. However, the speculative unsustainability of the growth model highlights the need to redirect the construction sector towards urban renovation using a bioclimatic approach. The public space plays a key role in improving the quality of today’s cities, especially in terms of providing places for citizens to meet and socialize in adequate thermal conditions. Thermal comfort affects perception of the environment, so microclimate conditions can be decisive for the success or failure of outdoor urban spaces and the activities held in them. For these reasons, the main focus of this work is on the definition of bioclimatic strategies for existing urban spaces, based on morpho-typological components, urban microclimate conditions and comfort requirements for all kinds of citizens. Two case studies were selected in Madrid, in a social housing neighbourhood constructed in the 1970s based on Rational Architecture style. Several renovation scenarios were performed using a computer simulation process based in ENVI-met and diverse microclimate conditions were compared. In addition, thermal comfort evaluation was carried out using the Universal Thermal Climate Index (UTCI) in order to investigate the relationship between microclimate conditions and thermal comfort perception. This paper introduces the microclimate computer simulation process as a valuable support for decision-making for neighbourhood renovation projects in order to provide new and better solutions according to the thermal quality of public spaces and reducing energy consumption by creating and selecting better microclimate areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O cenário competitivo e globalizado em que as empresas estão inseridas, sobretudo a partir do século XXI, associados a ciclos de vida cada vez menores dos produtos, rigorosos requisitos de qualidade, além de políticas de preservação do meio ambiente, com redução de consumo energético e de recursos hídricos, somadas às exigências legais de melhores condições de trabalho, resultaram em uma quebra de paradigma nos processos produtivos até então concebidos. Como solução a este novo cenário produtivo pode-se citar o extenso uso da automação industrial, fato que resultou em sistemas cada vez mais complexos, tanto do ponto de vista estrutural, em função do elevado número de componentes, quanto da complexidade dos sistemas de controle. A previsibilidade de todos os estados possíveis do sistema torna-se praticamente impossível. Dentre os estados possíveis pode-se citar os estados de falha que, dependendo da severidade do efeito associado à sua ocorrência, podem resultar em sérios danos para o homem, o meio ambiente e às próprias instalações, caso não sejam corretamente diagnosticados e tratados. Fatos recentes de catástrofes relacionadas à sistemas produtivos revelam a necessidade de se implementar medidas para prevenir e para mitigar os efeitos da ocorrência de falhas, com o objetivo de se evitar a ocorrência de catástrofes. De acordo com especialistas, os Sistemas Instrumentados de Segurança SIS, referenciados em normas como a IEC 61508 e IEC 61511, são uma solução para este tipo de problema. Trabalhos publicados tratam de métodos para a implementação de camadas SIS de prevenção, porém com escassez de trabalhos para camadas SIS de mitigação. Em função do desconhecimento da dinâmica do sistema em estado de falha, técnicas tradicionais de modelagem tornam-se inviáveis. Neste caso, o uso de inteligência artificial, como por exemplo a lógica fuzzy, pode se tornar uma solução para o desenvolvimento do algoritmo de controle, associadas a ferramentas de edição, modelagem e geração dos códigos de controle. A proposta deste trabalho é apresentar uma sistemática para a implementação de um sistema de controle para a mitigação de falhas críticas em sistemas produtivos, com referência às normas IEC 61508/61511, com ação antecipativa à ocorrência de catástrofes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Buildings and the whole built environment are in a key role when societies are mitigating climate change and adapting to its consequences. More than 50% of the existing residential buildings in EU-25 were built before 1970. Thus, these buildings are of significant importance in reducing energy consumption and CO2 emissions. The existence of more nearly zero energy buildings (nZEB) is a possible solution for this problem. This study aims to analyze the application of the nZEB methodology in the retrofitting of a typical Portuguese dwelling build in 1950. It was shown that the primary energy used can be reduced to a very low value (11,95 kWhep/m2.y) in comparison with the reference consumption (69,15 kWhep/m2.y), with the application of the best construction techniques together with the use of energy from on-site renewable sources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hoje em dia a preocupação ambiental e a economia são fatores de sustentabilidade que são tidos em conta em países desenvolvidos, especialmente no seio da União Europeia. Reduzir os consumos de energia é, portanto, um ponto-chave para a redução das emissões de gases com efeito de estufa e aumentar a dependência das energias renováveis. Consequentemente surge então a necessidade de aumentar a eficiência dos equipamentos, em particular no presente caso, equipamentos de refrigeração. Para isso foi adotado pela Comissão Europeia uma rotulagem nos produtos consumidores de energia, em particular na refrigeração, os frigoríficos e congeladores domésticos permitindo informar o consumidor para os equipamentos mais eficientes. Mais recentemente, frigoríficos comerciais e profissionais também terão obrigatoriedade de incluir um rótulo energético na parte externa dos mesmos. Nesses rótulos estão incluídas várias informações técnicas do aparelho representadas de uma forma compreensível e lúdica aos olhos do consumidor mais leigo, entre as quais as classes de eficiência energética. As classes de eficiência energética caracterizam-se pela componente tecnológica dos frigoríficos. Perceber quais os componentes e materiais em particular que promovem uma melhor eficiência, quantificar a sua influência e avaliar os seus custos de integração torna-se assim essencial para toda a cadeia envolvida na produção destes equipamentos. Os fluídos frigorigénios e compressores aparentam ser os que mais exercem influência na eficiência de frigoríficos de baixa potência. Tubos capilares com trocador de calor são uma escolha mais eficiente comparado com o tubo capilar padrão que é utilizado nestes frigoríficos. Por forma a obter informação adicional e relevante do ponto de vista da análise energética realizaram-se simulações para determinação do consumo elétrico anual com recurso ao software Pack Calculation Pro. Entre os fluídos frigorigénios R-134a, R-22 e R-410a, os compressores scroll apresentaram consumos mais reduzidos (no máximo de 16%) do que os compressores alternativos. No caso do amoníaco (R-717) os compressores alternativos consumiram em média 14% menos do que os compressores parafuso. O recurso a velocidade variável em compressores permite reduzir o consumo na ordem dos 25%. Válvulas de expansão eletrónicas trazem reduções no consumo de 1,5% quando comparadas com válvulas de expansão termostáticas em compressores de velocidade variável. O propano (R-290) é um gás que mostra ter um melhor desempenho do que o R-134a e R404a em vários compressores, consumindo 16% menos do que o R-404a. Em função da temperatura exterior, o R-290 também apresentou um bom desempenho consumindo em climas quentes (Belém, Brasil) 24% menos do que o R-404a.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Doutor em Design, apresentada na Universidade de Lisboa - Faculdade de Arquitetura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A indústria cimenteira é uma indústria com grandes gastos energéticos, sendo por Isso de extrema importância, do ponto de vista económico, desenvolver estratégias e procedimentos que conduzam à sua minimização. O intuito da realização do presente trabalho foi estudar a reactividade do clínquer da Cimpor­ Centro de Produção de Loulé, ao introduzir alterações ao processo de fabrico de cimento. O estudo engloba três objectivos: C. Melhorar a qualidade do clínquer; C. Reduzir o consumo térmico do forno; C. Reduzir o consumo energético dos moinhos de cimento. Na paragem de Maio de 2008 foi instalado um novo redutor para o motor do forno que permitiu alterar a velocidade máxima de 2 para 3,5 rpm, o que consequentemente diminuiu a taxa de enchimento de ≈20% para ≈14%. Os resultados mostraram que com a alteração ao processo atingiram-se dois dos três objectivos pretendidos. Isto é, obteve-se um clínquer de melhor qualidade e houve uma diminuição do consumo térmico do forno. Contudo, não se conseguiram tirar conclusões acerca do consumo energético dos moinhos de cimento, sendo para tal, necessário prolongar o tempo do estudo. ABSTRACT: The cement industry is an industry with high energy costs and is therefore of extreme importance, in economic terms, to develop strategies and procedures that lead to its minimization. The purpose of this work was to study the reactivity of the clinker produced at Loulé Cimpor Production Center by introducing changes in the manufacture process of cement. The study comprised three main objectives: C. Improving the quality of the clinker; C. Reducing the heat consumption of the furnace; C. Reducing energy consumption of the cement mills. During the stop of May 2008 a new reducer was installed in the furnace motor which allowed changing the maximum speed of 2 to 3.5 rpm, which consequently decreased the rate of filling from ≈20% to ≈14%. The results showed that with the process modification, two of the three objectives were reached up. That is, a better quality of clinker was obtained and there was a decrease in the heat consumption of the furnace. However, during the period of this study it was not possible to draw a final conclusion about the energy consumption of the cement mills, and therefore, it is necessary to study the process for a longer period of time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last two or three years, the increasing costs of energy and worsening market conditions have focussed even greater attention within paper mills than before, on considering ways to improve efficiency and reduce the energy used in paper making. Arising from a multivariable understanding of paper machine operation, Advanced Process Control (APC) technology enables paper machine behaviour to be controlled in a more coherent way, using all the variables available for control. Furthermore, with the machine under better regulation and with more variables used in control, there is the opportunity to optimise machine operation, usually providing very striking multi-objective performance improvement benefits of a number of kinds. Traditional three term control technology does not offer this capability. The paper presents results from several different paper machine projects we have undertaken around the world. These projects have been aimed at improving machine stability, optimising chemicals usage and reducing energy use. On a brown paperboard machine in Australasia, APC has reduced specific steam usage by 10%, averaged across the grades; the controller has also provided a significant capacity to increase production. On a North American newsprint machine, the APC system has reduced steam usage by more than 10%, and it provides better control of colour and much improved wet end stability. The paper also outlines early results from two other performance improvement projects, each incorporating a different approach to reducing the energy used in paper making. The first of these two projects is focussed on optimising sheet drainage, aiming to present the dryer with a sheet having higher solids content than before. The second project aims to reduce specific steam usage by optimising the operation of the dryer hood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The past decade has seen the energy consumption in servers and Internet Data Centers (IDCs) skyrocket. A recent survey estimated that the worldwide spending on servers and cooling have risen to above $30 billion and is likely to exceed spending on the new server hardware . The rapid rise in energy consumption has posted a serious threat to both energy resources and the environment, which makes green computing not only worthwhile but also necessary. This dissertation intends to tackle the challenges of both reducing the energy consumption of server systems and by reducing the cost for Online Service Providers (OSPs). Two distinct subsystems account for most of IDC’s power: the server system, which accounts for 56% of the total power consumption of an IDC, and the cooling and humidifcation systems, which accounts for about 30% of the total power consumption. The server system dominates the energy consumption of an IDC, and its power draw can vary drastically with data center utilization. In this dissertation, we propose three models to achieve energy effciency in web server clusters: an energy proportional model, an optimal server allocation and frequency adjustment strategy, and a constrained Markov model. The proposed models have combined Dynamic Voltage/Frequency Scaling (DV/FS) and Vary-On, Vary-off (VOVF) mechanisms that work together for more energy savings. Meanwhile, corresponding strategies are proposed to deal with the transition overheads. We further extend server energy management to the IDC’s costs management, helping the OSPs to conserve, manage their own electricity cost, and lower the carbon emissions. We have developed an optimal energy-aware load dispatching strategy that periodically maps more requests to the locations with lower electricity prices. A carbon emission limit is placed, and the volatility of the carbon offset market is also considered. Two energy effcient strategies are applied to the server system and the cooling system respectively. With the rapid development of cloud services, we also carry out research to reduce the server energy in cloud computing environments. In this work, we propose a new live virtual machine (VM) placement scheme that can effectively map VMs to Physical Machines (PMs) with substantial energy savings in a heterogeneous server cluster. A VM/PM mapping probability matrix is constructed, in which each VM request is assigned with a probability running on PMs. The VM/PM mapping probability matrix takes into account resource limitations, VM operation overheads, server reliability as well as energy effciency. The evolution of Internet Data Centers and the increasing demands of web services raise great challenges to improve the energy effciency of IDCs. We also express several potential areas for future research in each chapter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis is a documented energy audit and long term study of energy and water reduction in a ghee factory. Global production of ghee exceeds 4 million tonnes annually. The factory in this study refines dairy products by non-traditional centrifugal separation and produces 99.9% pure, canned, crystallised Anhydrous Milk Fat (Ghee). Ghee is traditionally made by batch processing methods. The traditional method is less efficient, than centrifugal separation. An in depth systematic investigation was conducted of each item of major equipment including; ammonia refrigeration, a steam boiler, canning equipment, pumps, heat exchangers and compressed air were all fine-tuned. Continuous monitoring of electrical usage showed that not every initiative worked, others had pay back periods of less than a year. In 1994-95 energy consumption was 6,582GJ and in 2003-04 it was 5,552GJ down 16% for a similar output. A significant reduction in water usage was achieved by reducing the airflow in the refrigeration evaporative condensers to match the refrigeration load. Water usage has fallen 68% from18ML in 1994-95 to 5.78ML in 2003-04. The methods reported in this thesis could be applied to other industries, which have similar equipment, and other ghee manufacturers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces an energy-efficient Rate Adaptive MAC (RA-MAC) protocol for long-lived Wireless Sensor Networks (WSN). Previous research shows that the dynamic and lossy nature of wireless communication is one of the major challenges to reliable data delivery in a WSN. RA-MAC achieves high link reliability in such situations by dynamically trading off radio bit rate for signal processing gain. This extra gain reduces the packet loss rate which results in lower energy expenditure by reducing the number of retransmissions. RA-MAC selects the optimal data rate based on channel conditions with the aim of minimizing energy consumption. We have implemented RA-MAC in TinyOS on an off-the-shelf sensor platform (TinyNode), and evaluated its performance by comparing RA-MAC with state-ofthe- art WSN MAC protocol (SCP-MAC) by experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the tradeoff between energy consumption and localization performance in a mobile sensor network application. The focus is on augmenting GPS location with more energy-efficient location sensors to bound position estimate uncertainty in order to prolong node lifetime. We use empirical GPS and radio contact data from a largescale animal tracking deployment to model node mobility, GPS and radio performance. These models are used to explore duty cycling strategies for maintaining position uncertainty within specified bounds. We then explore the benefits of using short-range radio contact logging alongside GPS as an energy-inexpensive means of lowering uncertainty while the GPS is off, and we propose a versatile contact logging strategy that relies on RSSI ranging and GPS lock back-offs for reducing the node energy consumption relative to GPS duty cycling. Results show that our strategy can cut the node energy consumption by half while meeting application specific positioning criteria.