981 resultados para Reasonable Accommodation
Resumo:
This cross-sectional study describes the variation in the dietary intake of energy and macronutrients based on estimated coefficients of within- and between-person variation and intends to calculate the number of days required to evaluate the dietary intake of adolescents in Piracicaba, Brazil. The sample was made up by ninety-two adolescents aged between eleven and sixteen years. Interviews were performed to assess demographic, anthropometric and dietary variables, which were evaluated by the answers obtained through two 24-hour recalls. Descriptive analyses were performed and variances and Coefficients of variation within- and between-person were obtained by results of one-way ANOVA. The mean energy intake observed was 2,326.2 kilocalories; mean macronutrient intake came to 89.0 grams of fatty acids, 305.3 grams of carbohydrates and 82.2 grams of proteins. Coefficients of within-person variation ranged from 36% to 45%, while between-person coefficients varied from 26% to 31%. Variance ratios ranged from 1.35 (carbohydrate) to 2.62 (protein). The lowest number of observations required to correctly evaluate the usual diet calculated (r = 0.90) was six days, for carbohydrates while the highest was eleven, for proteins. Coefficients of variation were similar to those observed in international studies. We conclude that, in this study, two observations were sufficient to obtain reasonable correlations. However, six evaluations are necessary for these adolescents in order to obtain excellent correlations.
Resumo:
OBJETIVOS: identificar a opinião de pediatras e conhecer as recomendações de entidades profissionais e instituições públicas de saúde quanto à prescrição de suplementos fluorados. MÉTODOS: um questionário foi enviado a médicos pediatras. Informações adicionais sobre recomendações de suplementos fluorados foram obtidas junto a sete entidades profissionais e quatro instituições públicas de saúde. RESULTADOS: aproximadamente um em cada dez pediatras declarou prescrever algum suplemento contendo flúor. Risco de fluorose dentária, porque a água é fluoretada, foi a principal razão para afirmar que isso não deve ser feito. Quanto às entidades profissionais, duas deram respostas apropriadas. As respostas das demais não foram satisfatórias quanto ao uso racional de flúor. As respostas das instituições públicas foram apropriadas, embora o Ministério da Saúde não tenha se posicionado a respeito. CONCLUSÕES: um em cada 10 pediatras declarou prescrever suplementos contendo flúor para crianças residentes em São Paulo, cidade com água fluoretada. Em consequência, é necessário que o poder público e as entidades odontológicas assumam suas responsabilidades quanto ao uso dos suplementos fluorados.
Resumo:
Este artigo apresenta e discute os dados de uma pesquisa sobre violência institucional em maternidades públicas, realizada no município de São Paulo. Foram entrevistadas 21 puérperas, com roteiro semiestruturado contando com questões sobre experiências de parto e assistência recebida. Os dados revelaram que as entrevistadas relatam e reconhecem práticas discriminatórias e tratamento grosseiro no âmbito da assistência em maternidades públicas, reagindo com estratégias de resistência ou de acomodação. Essas experiências ocorrem com tal frequência que muitas parturientes já esperam sofrer algum tipo de maltrato, o que revela uma banalização da violência institucional.
Resumo:
The study was done to evaluate the cost-effectiveness of a national rotavirus vaccination programme in Brazilian children from the healthcare system perspective. A hypothetical annual birth-cohort was followed for a five-year period. Published and national administrative data were incorporated into a model to quantify the consequences of vaccination versus no vaccination. Main outcome measures included the reduction in disease burden, lives saved, and disability-adjusted life-years (DALYs) averted. A rotavirus vaccination programme in Brazil would prevent an estimated 1,804 deaths associated with gastroenteritis due to rotavirus, 91,127 hospitalizations, and 550,198 outpatient visits. Vaccination is likely to reduce 76% of the overall healthcare burden of rotavirus-associated gastroenteritis in Brazil. At a vaccine price of US$ 7-8 per dose, the cost-effectiveness ratio would be US$ 643 per DALY averted. Rotavirus vaccination can reduce the burden of gastroenteritis due to rotavirus at a reasonable cost-effectiveness ratio.
Resumo:
A Epistemologia Genética defende que o indivíduo passa por várias etapas de desenvolvimento ao longo da sua vida. O desenvolvimento é observado pela sobreposição do equilíbrio entre a assimilação e a acomodação, resultando em adaptação. Assim, nesta formulação, o ser humano assimila os dados que obtém do exterior, mas uma vez que já tem uma estrutura mental que não está vazia, precisa adaptar esses dados à estrutura mental já existe. O processo de modificação de si próprio é chamado de acomodação. Este esquema revela que nenhum conhecimento chega do exterior sem que sofra alguma alteração pelo indivíduo, sendo que tudo o que se aprende é influenciado por aquilo que já havia sido aprendido. A assimilação ocorre quando a informação é incorporada às estruturas já pré-existentes nessa dinâmica estrutura cognitiva, enquanto que a adaptação ocorre quando o organismo se modifica de alguma maneira de modo a incorporar dinamicamente a nova informação. Por fim, de um pensamento moderno que, buscando a síntese inusitada entre o biológico e o lógico-matemático, parece encontrar seus limites na desconstrução ainda mais inusitada a que tende sistematicamente todo o pensamento na atualidade: a de si mesmo se construindo de modo essencialmente esclarecido
Resumo:
A Epistemologia Genética defende que o indivíduo passa por várias etapas de desenvolvimento ao longo da sua vida. O desenvolvimento é observado pela sobreposição do equilíbrio entre a assimilação e a acomodação, resultando em adaptação. Assim, nesta formulação, o ser humano assimila os dados que obtém do exterior, mas uma vez que já tem uma estrutura mental que não está vazia, precisa adaptar esses dados à estrutura mental já existe. O processo de modificação de si próprio é chamado de acomodação. Este esquema revela que nenhum conhecimento chega do exterior sem que sofra alguma alteração pelo indivíduo, sendo que tudo o que se aprende é influenciado por aquilo que já havia sido aprendido. A assimilação ocorre quando a informação é incorporada às estruturas já pré-existentes nessa dinâmica estrutura cognitiva, enquanto que a adaptação ocorre quando o organismo se modifica de alguma maneira de modo a incorporar dinamicamente a nova informação. Por fim, de um pensamento moderno que, buscando a síntese inusitada entre o biológico e o lógico-matemático, parece encontrar seus limites na desconstrução ainda mais inusitada a que tende sistematicamente todo o pensamento na atualidade: a de si mesmo se construindo de modo essencialmente esclarecido
Resumo:
Currently, the acoustic and nanoindentation techniques are two of the most used techniques for material elastic modulus measurement. In this article fundamental principles and limitations of both techniques are shown and discussed. Last advances in nanoindentation technique are also reviewed. An experimental study in ceramic, metallic, composite and single crystals was also done. Results shown that ultrasonic technique is capable to provide results in agreement with those reported in literature. However, ultrasonic technique does not allow measuring the elastic modulus of some small samples and single crystals. On the other hand, the nanoindentation technique estimates the elastic modulus values in reasonable agreement with those measured by acoustic methods, particularly in amorphous materials, while in some policristaline materials some deviation from expected values was obtained.
Resumo:
Background: Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intramedullary nail to be applied percutaneously in the fixation of femoral rotational osteotomies in children with cerebral palsy and evaluated its mechanical properties. Methods: The study was divided into three stages. In the first part, a prototype was designed and made based on radiographic measurements of the femoral medullary canal of ten-year-old patients. In the second, synthetic femoral models based on rapid-prototyping of 3D reconstructed images of patients with cerebral palsy were obtained and were employed to adjust the nail prototype to the morphological changes observed in this disease. In the third, rotational osteotomies were simulated using synthetic femoral models stabilized by the nail and by the AO-ASIF fixed-angle blade plate. Mechanical testing was done comparing both devices in bending-compression and torsion. Results: The authors observed proper adaptation of the nail to normal and morphologically altered femoral models, and during the simulated osteotomies. Stiffness in bending-compression was significantly higher in the group fixed by the plate (388.97 +/- 57.25 N/mm) than in that fixed by the nail (268.26 +/- 38.51 N/mm) as torsional relative stiffness was significantly higher in the group fixed by the plate (1.07 +/- 0.36 Nm/degrees) than by the nail (0.35 +/- 0.13 Nm/degrees). Conclusions: Although the device presented adequate design and dimension to fit into the pediatric femur, mechanical tests indicated that the nail was less stable than the blade plate in bending-compression and torsion. This may be a beneficial property, and it can be attributed to the more flexible fixation found in intramedullary devices.
Resumo:
Interference by autofluorescence is one of the major concerns of immunofluorescence analysis of in situ hybridization-based diagnostic assays. We present a useful technique that reduces autofluorescent background without affecting the tissue integrity or direct immunofluorescence signals in brain sections. Using six different protocols, such as ammonia/ethanol, Sudan Black B (SBB) in 70% ethanol, photobleaching with UV light and different combinations of them in both formalin-fixed paraffin-embedded and frozen human brain tissue sections, we have found that tissue treatment of SBB in a concentration of 0.1% in 70% ethanol is the best approach to reduce/eliminate tissue autofluorescence and background, while preserving the specific fluorescence hybridization signals. This strategy is a feasible, non-time consuming method that provides a reasonable compromise between total reduction of the tissue autofluorescence and maintenance of specific fluorescent labels.
Resumo:
Aims. A model-independent reconstruction of the cosmic expansion rate is essential to a robust analysis of cosmological observations. Our goal is to demonstrate that current data are able to provide reasonable constraints on the behavior of the Hubble parameter with redshift, independently of any cosmological model or underlying gravity theory. Methods. Using type Ia supernova data, we show that it is possible to analytically calculate the Fisher matrix components in a Hubble parameter analysis without assumptions about the energy content of the Universe. We used a principal component analysis to reconstruct the Hubble parameter as a linear combination of the Fisher matrix eigenvectors (principal components). To suppress the bias introduced by the high redshift behavior of the components, we considered the value of the Hubble parameter at high redshift as a free parameter. We first tested our procedure using a mock sample of type Ia supernova observations, we then applied it to the real data compiled by the Sloan Digital Sky Survey (SDSS) group. Results. In the mock sample analysis, we demonstrate that it is possible to drastically suppress the bias introduced by the high redshift behavior of the principal components. Applying our procedure to the real data, we show that it allows us to determine the behavior of the Hubble parameter with reasonable uncertainty, without introducing any ad-hoc parameterizations. Beyond that, our reconstruction agrees with completely independent measurements of the Hubble parameter obtained from red-envelope galaxies.
Resumo:
We have measured the azimuthal anisotropy of pi(0) production for 1 < p(T) < 18 GeV/c for Au + Au collisions at root s(NN) = 200 GeV. The observed anisotropy shows a gradual decrease for 3 less than or similar to p(T) less than or similar to 7-10 GeV/c, but remains positive beyond 10 GeV/c. The magnitude of this anisotropy is underpredicted, up to at least similar to 10 GeV/c, by current perturbative QCD (PQCD) energy-loss model calculations. An estimate of the increase in anisotropy expected from initial-geometry modification due to gluon saturation effects and fluctuations is insufficient to account for this discrepancy. Calculations that implement a path-length dependence steeper than what is implied by current PQCD energy-loss models show reasonable agreement with the data.
Resumo:
We investigate a neutrino mass model in which the neutrino data is accounted for by bilinear R-parity violating supersymmetry with anomaly mediated supersymmetry breaking. We focus on the CERN Large Hadron Collider (LHC) phenomenology, studying the reach of generic supersymmetry search channels with leptons, missing energy and jets. A special feature of this model is the existence of long-lived neutralinos and charginos which decay inside the detector leading to detached vertices. We demonstrate that the largest reach is obtained in the displaced vertices channel and that practically all of the reasonable parameter space will be covered with an integrated luminosity of 10 fb(-1). We also compare the displaced vertex reaches of the LHC and Tevatron.
Resumo:
Experimental studies of magnetoresistance in high-mobility wide quantum wells reveal oscillations which appear with an increase in temperature to 10 K and whose period is close to that of Shubnikov-de Haas oscillations. The observed phenomenon is identified as magnetointersubband oscillations caused by the scattering of electrons between two occupied subbands and the third subband which becomes occupied as a result of thermal activation. These small-period oscillations are less sensitive to thermal suppression than the large-period magnetointersubband oscillations caused by the scattering between the first and the second subbands. Theoretical study, based on consideration of electron scattering near the edge of the third subband, gives a reasonable explanation of our experimental findings.
Resumo:
Neutrino telescopes with cubic kilometer volumes have the potential to discover new particles. Among them are next to lightest supersymmetric (NLSPs) and next to lightest Kaluza-Klein (NLKPs) particles. Two NLSPs or NLKPs will transverse the detector simultaneously producing parallel charged tracks. The track separation inside the detector can be a few hundred meters. As these particles might propagate a few thousand kilometers before reaching the detector, multiple scattering could enhance the pair separation at the detector. We find that the multiple scattering will alter the separation distribution enough to increase the number of NLKP pairs separated by more than 100 meters (a reasonable experimental cut) by up to 46% depending on the NLKP mass. Vertical upcoming NLSPs will have their separation increased by 24% due to multiple scattering.
Resumo:
Laser induced breakdown spectroscopy (LIBS) has become an analytical tool for the direct analysis of a large variety of materials in order to provide qualitative and/or quantitative information. However, there is a lack of information for LIBS analysis of agricultural and environmental samples. In this work a LIBS system has been evaluated for the determination of macronutrients (P, K, Ca, Mg) in pellets of vegetal reference materials. An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with ICCD detector. The plasma temperature was estimated by Boltzmann plots and instrumental paragmeters such as delay time, lens-to-sample distance and pulse energy were evaluated. Certified reference materials as well as reference materials were used for analytical calibrations of P, K, Ca, and Mg. Most results of the direct analysis of plant samples by LIBS were in reasonable agreement with those obtained by ICP OES after wet acid decomposition. (C) 2008 Elsevier B.V. All rights reserved.