166 resultados para Radiologists


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In modern magnetic resonance imaging (MRI), both patients and radiologists are exposed to strong, nonuniform static magnetic fields inside or outside of the scanner, in which the body movement may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced E-fields in the human model when moving at various positions around the magnet. The numerical calculations are based on an efficient, quasistatic, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively-shielded 4 T magnet system are used and the body model projected through the field profile with normalized velocity. The simulation shows that it is possible to induce E-fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are easy to extrapolate to very high field strengths for the safety evaluation at a variety of field strengths and motion velocities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cephalometric analysis is the mensuration of linear and angular measures through demarcation points as distances and lines on teleradiography, and is considered of fundamental importance for diagnosis and orthodontic planning. In this manner, the objective of this research was to compare cephalometric measurements obtained by dentists and radiologists from the analysis of the same radiograph, in a computerized cephalometric analysis program. All research participants marked 18 cephalometric points on a 14-inch notebook computer, as directed by the program itself (Radiocef 2®). From there, they generated 14 cephalometric parameters including skeletal, dental-skeletal, dental and soft tissue. In order to verify the intra-examiner agreement, 10 professionals from each group repeated the marking of the points with a minimum interval of eight days between the two markings. The intra-group variability was calculated based on the coefficients of variation (CV). The comparison between groups was performed using the Student t-test for normally distributed variables, and using the Mann-Whitney test for those with non-normal distribution. In the group of orthodontists, the measurements of Pog and 1-NB, SL, S-Ls Line, S-Li Line and 1.NB showed high internal variability. In the group of radiologists, the same occurred with the values of Pog and 1-NB, S-Ls Line, S-Li Line and 1.NA. In the comparison between groups, all the analyzed linear values and two angular values showed statistically significant differences between radiologists and dentists (p <0.05). According to the results, the interexaminer error in cephalometric analysis requires more attention, but does not come from a specific class of specialists, being either dentists or radiologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently, the diagnostic ultrasound is inserted in various areas of medical action and carried out by many medical professionals, from which militate directly in the image area, such as radiologists and sonographers, but also by gynecologists, pediatricians, neurologists, general practitioners, endocrinologists, angiologists, orthopedists, rheumatologists, urologists, general and vascular surgeons. It is well known that the medical professional, for the exercise of its mission, requires a broad set of skills, competencies and attitudes developed and exercised during their training period. Living with medical students over nearly 20 years in hospital environment, I noticed gaps in the learning process by the students about what is diagnostic ultrasound and its applications, demonstrating failures as understanding the basic acoustic ultrasound, difficulties in identifying of anatomical structures in ultrasound images and inability in requests examinations and interpretations of images and reports. Based on these findings, it was developed in this Professional Masters a multimedia digital book that exposes what the ultrasound as a diagnostic modality imaging, dealing with its historiography and its physical/acoustic concepts, relating the process of formation of the ultrasound image, discussing about the features of sonographic equipments and their embedded technologies and highlighting its diagnostic applications , the latter presented through videos which will be described aspects of captured ultrasound images. This book will be available for access in digital format, serving as a teaching tool in medical education since the beginning of the course, so that can be used in conjunction with the discipline of Gross Anatomy, offered in the basic cycle of the Medicine Undergraduate Course of the Federal University of Rio Grande do Norte (UFRN).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patient awareness and concern regarding the potential health risks from ionizing radiation have peaked recently (Coakley et al., 2011) following widespread press and media coverage of the projected cancer risks from the increasing use of computed tomography (CT) (Berrington et al., 2007). The typical young and educated patient with inflammatory bowel disease (IBD) may in particular be conscious of his/her exposure to ionising radiation as a result of diagnostic imaging. Cumulative effective doses (CEDs) in patients with IBD have been reported as being high and are rising, primarily due to the more widespread and repeated use of CT (Desmond et al., 2008). Radiologists, technologists, and referring physicians have a responsibility to firstly counsel their patients accurately regarding the actual risks of ionizing radiation exposure; secondly to limit the use of those imaging modalities which involve ionising radiation to clinical situations where they are likely to change management; thirdly to ensure that a diagnostic quality imaging examination is acquired with lowest possible radiation exposure. In this paper, we synopsize available evidence related to radiation exposure and risk and we report advances in low-dose CT technology and examine the role for alternative imaging modalities such as ultrasonography or magnetic resonance imaging which avoid radiation exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray computed tomography (CT) imaging constitutes one of the most widely used diagnostic tools in radiology today with nearly 85 million CT examinations performed in the U.S in 2011. CT imparts a relatively high amount of radiation dose to the patient compared to other x-ray imaging modalities and as a result of this fact, coupled with its popularity, CT is currently the single largest source of medical radiation exposure to the U.S. population. For this reason, there is a critical need to optimize CT examinations such that the dose is minimized while the quality of the CT images is not degraded. This optimization can be difficult to achieve due to the relationship between dose and image quality. All things being held equal, reducing the dose degrades image quality and can impact the diagnostic value of the CT examination.

A recent push from the medical and scientific community towards using lower doses has spawned new dose reduction technologies such as automatic exposure control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose reduction potential of these new technologies in an objective and rigorous manner. Establishing these dose reduction potentials requires precise and clinically relevant metrics of CT image quality, as well as practical and efficient methodologies to measure such metrics on real CT systems. The currently established methodologies for assessing CT image quality are not appropriate to assess modern CT scanners that have implemented those aforementioned dose reduction technologies.

Thus the purpose of this doctoral project was to develop, assess, and implement new phantoms, image quality metrics, analysis techniques, and modeling tools that are appropriate for image quality assessment of modern clinical CT systems. The project developed image quality assessment methods in the context of three distinct paradigms, (a) uniform phantoms, (b) textured phantoms, and (c) clinical images.

The work in this dissertation used the “task-based” definition of image quality. That is, image quality was broadly defined as the effectiveness by which an image can be used for its intended task. Under this definition, any assessment of image quality requires three components: (1) A well defined imaging task (e.g., detection of subtle lesions), (2) an “observer” to perform the task (e.g., a radiologists or a detection algorithm), and (3) a way to measure the observer’s performance in completing the task at hand (e.g., detection sensitivity/specificity).

First, this task-based image quality paradigm was implemented using a novel multi-sized phantom platform (with uniform background) developed specifically to assess modern CT systems (Mercury Phantom, v3.0, Duke University). A comprehensive evaluation was performed on a state-of-the-art CT system (SOMATOM Definition Force, Siemens Healthcare) in terms of noise, resolution, and detectability as a function of patient size, dose, tube energy (i.e., kVp), automatic exposure control, and reconstruction algorithm (i.e., Filtered Back-Projection– FPB vs Advanced Modeled Iterative Reconstruction– ADMIRE). A mathematical observer model (i.e., computer detection algorithm) was implemented and used as the basis of image quality comparisons. It was found that image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose (increase in detectability index by up to 163% depending on iterative strength). The use of automatic exposure control resulted in more consistent image quality with changing phantom size.

Based on those results, the dose reduction potential of ADMIRE was further assessed specifically for the task of detecting small (<=6 mm) low-contrast (<=20 HU) lesions. A new low-contrast detectability phantom (with uniform background) was designed and fabricated using a multi-material 3D printer. The phantom was imaged at multiple dose levels and images were reconstructed with FBP and ADMIRE. Human perception experiments were performed to measure the detection accuracy from FBP and ADMIRE images. It was found that ADMIRE had equivalent performance to FBP at 56% less dose.

Using the same image data as the previous study, a number of different mathematical observer models were implemented to assess which models would result in image quality metrics that best correlated with human detection performance. The models included naïve simple metrics of image quality such as contrast-to-noise ratio (CNR) and more sophisticated observer models such as the non-prewhitening matched filter observer model family and the channelized Hotelling observer model family. It was found that non-prewhitening matched filter observers and the channelized Hotelling observers both correlated strongly with human performance. Conversely, CNR was found to not correlate strongly with human performance, especially when comparing different reconstruction algorithms.

The uniform background phantoms used in the previous studies provided a good first-order approximation of image quality. However, due to their simplicity and due to the complexity of iterative reconstruction algorithms, it is possible that such phantoms are not fully adequate to assess the clinical impact of iterative algorithms because patient images obviously do not have smooth uniform backgrounds. To test this hypothesis, two textured phantoms (classified as gross texture and fine texture) and a uniform phantom of similar size were built and imaged on a SOMATOM Flash scanner (Siemens Healthcare). Images were reconstructed using FBP and a Sinogram Affirmed Iterative Reconstruction (SAFIRE). Using an image subtraction technique, quantum noise was measured in all images of each phantom. It was found that in FBP, the noise was independent of the background (textured vs uniform). However, for SAFIRE, noise increased by up to 44% in the textured phantoms compared to the uniform phantom. As a result, the noise reduction from SAFIRE was found to be up to 66% in the uniform phantom but as low as 29% in the textured phantoms. Based on this result, it clear that further investigation was needed into to understand the impact that background texture has on image quality when iterative reconstruction algorithms are used.

To further investigate this phenomenon with more realistic textures, two anthropomorphic textured phantoms were designed to mimic lung vasculature and fatty soft tissue texture. The phantoms (along with a corresponding uniform phantom) were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Scans were repeated a total of 50 times in order to get ensemble statistics of the noise. A novel method of estimating the noise power spectrum (NPS) from irregularly shaped ROIs was developed. It was found that SAFIRE images had highly locally non-stationary noise patterns with pixels near edges having higher noise than pixels in more uniform regions. Compared to FBP, SAFIRE images had 60% less noise on average in uniform regions for edge pixels, noise was between 20% higher and 40% lower. The noise texture (i.e., NPS) was also highly dependent on the background texture for SAFIRE. Therefore, it was concluded that quantum noise properties in the uniform phantoms are not representative of those in patients for iterative reconstruction algorithms and texture should be considered when assessing image quality of iterative algorithms.

The move beyond just assessing noise properties in textured phantoms towards assessing detectability, a series of new phantoms were designed specifically to measure low-contrast detectability in the presence of background texture. The textures used were optimized to match the texture in the liver regions actual patient CT images using a genetic algorithm. The so called “Clustured Lumpy Background” texture synthesis framework was used to generate the modeled texture. Three textured phantoms and a corresponding uniform phantom were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Images were reconstructed with FBP and SAFIRE and analyzed using a multi-slice channelized Hotelling observer to measure detectability and the dose reduction potential of SAFIRE based on the uniform and textured phantoms. It was found that at the same dose, the improvement in detectability from SAFIRE (compared to FBP) was higher when measured in a uniform phantom compared to textured phantoms.

The final trajectory of this project aimed at developing methods to mathematically model lesions, as a means to help assess image quality directly from patient images. The mathematical modeling framework is first presented. The models describe a lesion’s morphology in terms of size, shape, contrast, and edge profile as an analytical equation. The models can be voxelized and inserted into patient images to create so-called “hybrid” images. These hybrid images can then be used to assess detectability or estimability with the advantage that the ground truth of the lesion morphology and location is known exactly. Based on this framework, a series of liver lesions, lung nodules, and kidney stones were modeled based on images of real lesions. The lesion models were virtually inserted into patient images to create a database of hybrid images to go along with the original database of real lesion images. ROI images from each database were assessed by radiologists in a blinded fashion to determine the realism of the hybrid images. It was found that the radiologists could not readily distinguish between real and virtual lesion images (area under the ROC curve was 0.55). This study provided evidence that the proposed mathematical lesion modeling framework could produce reasonably realistic lesion images.

Based on that result, two studies were conducted which demonstrated the utility of the lesion models. The first study used the modeling framework as a measurement tool to determine how dose and reconstruction algorithm affected the quantitative analysis of liver lesions, lung nodules, and renal stones in terms of their size, shape, attenuation, edge profile, and texture features. The same database of real lesion images used in the previous study was used for this study. That database contained images of the same patient at 2 dose levels (50% and 100%) along with 3 reconstruction algorithms from a GE 750HD CT system (GE Healthcare). The algorithms in question were FBP, Adaptive Statistical Iterative Reconstruction (ASiR), and Model-Based Iterative Reconstruction (MBIR). A total of 23 quantitative features were extracted from the lesions under each condition. It was found that both dose and reconstruction algorithm had a statistically significant effect on the feature measurements. In particular, radiation dose affected five, three, and four of the 23 features (related to lesion size, conspicuity, and pixel-value distribution) for liver lesions, lung nodules, and renal stones, respectively. MBIR significantly affected 9, 11, and 15 of the 23 features (including size, attenuation, and texture features) for liver lesions, lung nodules, and renal stones, respectively. Lesion texture was not significantly affected by radiation dose.

The second study demonstrating the utility of the lesion modeling framework focused on assessing detectability of very low-contrast liver lesions in abdominal imaging. Specifically, detectability was assessed as a function of dose and reconstruction algorithm. As part of a parallel clinical trial, images from 21 patients were collected at 6 dose levels per patient on a SOMATOM Flash scanner. Subtle liver lesion models (contrast = -15 HU) were inserted into the raw projection data from the patient scans. The projections were then reconstructed with FBP and SAFIRE (strength 5). Also, lesion-less images were reconstructed. Noise, contrast, CNR, and detectability index of an observer model (non-prewhitening matched filter) were assessed. It was found that SAFIRE reduced noise by 52%, reduced contrast by 12%, increased CNR by 87%. and increased detectability index by 65% compared to FBP. Further, a 2AFC human perception experiment was performed to assess the dose reduction potential of SAFIRE, which was found to be 22% compared to the standard of care dose.

In conclusion, this dissertation provides to the scientific community a series of new methodologies, phantoms, analysis techniques, and modeling tools that can be used to rigorously assess image quality from modern CT systems. Specifically, methods to properly evaluate iterative reconstruction have been developed and are expected to aid in the safe clinical implementation of dose reduction technologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lung cancer is the most common cancer diagnosed in the UK. Outcomes for patients with this disease remain poor and new strategies to treat this disease require investigation. One potential option is to combine novel agents with radiotherapy in clinical studies. Here we discuss some of the important issues to consider when combining novel agents with radiotherapy, together with potential solutions as discussed at a recent Clinical Translational Radiotherapy Group (CTRad) workshop.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of re-programming the host immune system to target malignancy with durable anti-tumour clinical responses has been speculated for decades. In the last decade such speculation has been transformed into reality with unprecedented and durable responses to immune checkpoint inhibitors seen in solid tumours. This mini-review considers the mechanism of action of immune modulating agents and the potential for combination with radiotherapy in the treatment of non-small cell lung cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Foundation doctors are expected to assess and interpret plain x-ray studies of the chest/abdomen before a definitive report is issued by senior staff. The Royal College of Radiologists have published guidelines (RCR curriculum) on the scope of plain film findings medical students should be familiar with.1 Studies have shown that the x-ray interpretation without feedback does not significantly improve diagnostic ability. 2 Queen’s University, Belfast Trust Radiology and Experior Medical developed an online system to assess individual student ability to interpret X-ray findings. Over a series of assessments each student’s profile is built up, identifying strengths and weakness. The system can then create bespoke individual assessments re-evaluating previously identified weak areas and quantifying interpretative skill improvement. Aim: To determine how readily an online system is adopted by senior medical students, investigating if increasing exposure to x-ray interpretation combined with cyclical formative feedback enhances performance. Methods: The system was offered to all 270 final year medical students as an online resource. The system comprised a series of 20 weekly 30 minute assessments, containing normal and abnormal x-rays within the RCR curriculum. After each assessment students were given formative feedback, including their own result, annotated answers, peer group comparison and a breakdown of areas of strength and weakness. Focus groups of 4-5 students addressed student perspectives of the system, including ease of use, image resolution, system performance across different operating platforms, perceived value of formative feedback loops, breakdown of performance and the value of bespoke personalised assessments. Research Ethics Approval was granted for the study. Data analysis was via two-sided one-sample t-test; initial minimal recruitment was estimated as 60 students, to detect a mean 10% change in performance, with a standard deviation of 20%. Results and Discussion: Over 80% (n = XXX/270) of the student cohort engaged with the study. Student baseline average was 39%, increasing to 62% by the exit test. The steadily sustained improvement (57% relative performance in interpretative diagnostic accuracy) was despite increasing test difficulty. Student feedback via focus groups was universally positive throughout the examined domains. Conclusion: The online resource proved to be valuable, with high levels of student engagement, improving performance despite increasingly difficulty testing and positive learner experience with the system. References: 1. Undergraduate Radiology Curriculum, The Royal College of Ra, April 2012. Ref No. BFCR(12)4 The Royal College of Radiologists, April 2012 2. I Satia, S Bashagha, A Bibi, R Ahmed, S Mellor, F Zaman. Assessing the accuracy and certainty in interpretating chest x-rays in the medical division. Clin Med August 2013 Vol.13 no. 4 349-352

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are few professions in which visual acuity is as important as it is to radiologists. The diagnostic decision making process is composed of a number of events (detection or observation, interpretation and reporting), where the detection phase is subject to a number of physical and psychological phenomena that are critical to the process. Visual acuity is one phenomenon that has often been overlooked, and there is very little research assessing the impact of reduced visual acuity on diagnostic performance. The aim of this study was to investigate the impact of reduced visual acuity on an observer’s ability to detect simulated nodules in an anthropomorphic chest phantom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose - In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Materials and methods - Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (−1.00 D and −2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1–4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. Results - All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to −1.00 D and for one observer when defocussed to −2.00 D. Stereoacuity was unacceptable for one observer when defocussed to −2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). Conclusion - A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Improvements in diagnostic techniques and, above all, breast cancer screening campaigns - essential for early diagnosis - have enabled the objectives of conservative surgery to be pursued: disease control, no or low incidence of recurrences and an excellent esthetic result. However, to reach these objectives, it is essential to ensure a careful evaluation of the medical history of every patient, a detailed clinical examination and the correct interpretation of imaging. Particular attention should be paid to all factors influencing the choice of treatment and/or possible local recurrence: age, site, tumor volume, genetic predisposition, pregnancy, previous radiotherapy, pathological features, and surgical margins. The decision to undertake conservative treatment thus requires a multidisciplinary approach involving pathologists, surgeons and oncological radiologists, as well, of course, as the patient herself.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This text is taken from the postgraduate thesis, which one of the authors (A.B.) developed for the degree of Medical Physicist in the School on Medical Physics of the University of Florence. The text explores the feasibility of quantitative Magnetic Resonance Spectroscopy as a tool for daily clinical routine use. The results and analysis comes from two types of hyper spectral images: the first set are hyper spectral images coming from a standard phantom (reference images); and hyper spectral images obtained from a group of patients who have undergone MRI examinations at the Santa Maria Nuova Hospital. This interdisciplinary work stems from the IFAC-CNR know how in terms of data analysis and nanomedicine, and the clinical expertise of Radiologists and Medical Physicists. The results reported here, which were the subject of the thesis, are original, unpublished, and represent independent work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

International audience

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To review the epidemiological and clinical features of primary fallopian tube carcinoma (PFTC), and to illustrate the spectrum of MRI findings, with pathological confirmation. Methods This article reviews the relevant literature on the epidemiological, clinical, and imaging features of primary fallopian tube carcinoma, with pathological confirmation, using illustrations from the authors’ teaching files. Results Primary fallopian tube carcinoma came under focus over the last few years due to its possible role on the pathogenesis of high-grade serous epithelial ovarian and peritoneal cancers. Typical symptoms, together with the presence of some of the most characteristic MRI signs, such as a Bsausage-shaped^ pelvic mass, hydrosalpinx, and hydrometra, may signal the presence of primary fallopian cancer, and allow the radiologist to report it as a differential diagnosis. Conclusions Primary fallopian tube carcinoma has a constellation of clinical symptoms and magnetic resonance imaging features, which may be diagnostic. Although these findings are not present together in the majority of cases, radiologists who are aware of them may include the diagnosis of primary fallopian tube cancer in their report more frequently and with more confidence. Teaching Points • PFTC may be more frequent than previously thought • PFTC has specific clinical and MRI characteristics • Knowledge of typical PFTC signs enables its inclusion in the differential diagnosis • PFTC is currently staged under the 2013 FIGO system • PFTC is staged collectively with ovarian and peritoneal neoplasms