989 resultados para ROOT CANAL THERAPY
Resumo:
Introduction: Biocompatibility of root canal sealers is important because of the long-term contact of their eluates and/or degradation products with periapical tissues. The literature still lacks studies about the genotoxic effects of these materials and the influence of setting time on biological properties. The cytotoxicity and genotoxicity of an epoxy resin-based sealer (AH Plus), a single methacrylate-based sealer (EndoRez), and a silicone-based sealer (RoekoSeal) were assessed. Methods: Chinese hamster fibroblasts (V79) were cultured and exposed to different dilutions of extracts from the sealers that were left to set for 0, 12, and 24 hours before contact with culture medium. Cell viability was measured by the methyl-thiazol-diphenyltetrazolium assay. Genotoxicity was assessed by the comet assay. Data were statistically analyzed by Kruskal-Wallis and Dunn tests (P < .05). Results: Root canal sealers were statistically more cytotoxic than the untreated control group, except for the silicon-based sealer. Cell viability ranking was the following (from the most to the least cytotoxic): methacrylate-based > epoxy resin-based > silicone-based. The setting time influenced the epoxy resin-based sealer cytotoxicity (decreased at 12 hours) and the general genotoxicity (increased at 24 hours). DNA damage ranking was the following (from the most to the least genotoxic): methacrylate-based > silicone-based = epoxy resin-based. Conclusions: The setting time had influence on the cytotoxicity of the epoxy resin-based sealer and genotoxicity of all tested sealers. The methacrylate-based sealer was the most cytotoxic, and the silicone-based sealer was not cytotoxic. Genotoxicity was observed for all sealers. © 2013 American Association of Endodontists.
Resumo:
The aim of this study was to evaluate the effect of final irrigation protocols (17% EDTA, BioPure MTAD, SmearClear, and QMiX) on microhardness and erosion of root canal dentin. Fifty roots were sectioned transversely at the cement-enamel junction and each root was sectioned horizontally into 4-mm-thick slices. The samples were divided into five groups (n=10) according to the final irrigation protocol: G1: distilled water (control group); G2: 17% EDTA; G3: BioPure MTAD; G4: SmearClear; and G5: QMiX. The dentin microhardness was then measured with a load of 25 g for 10 s. Initially, the reference microhardness values were obtained for the samples without any etching. The same samples were then submitted to the final irrigation protocols. A new measure was realized and the difference between before and after the procedures was the dentin microhardness reduction. In sequence, the specimens were submitted to SEM analysis to verify the dentinal erosion. The Kruskal Wallis and Dunn tests (α=5%) were used to compare the results. The dentin microhardness decreased for all final irrigation protocols. There was no significant difference between groups 2, 3, 4, and 5 (P>0.05), but this groups presented significant dentin microhardness reduction than G1 (P<0.05). In G2, occurred the highest incidence of dentinal erosion (P<0.05). 17% EDTA, BioPure MTAD, SmearClear, and QMiX promoted significant dentin microhardness reduction. © 2013 Wiley Periodicals, Inc.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the “risk zone” of mandibular molars. Objectives: The aim of this study was to evaluate the effects of a crown-down sequence of Gates-Glidden and TripleGates burs on the remaining cervical dentin thickness and the total amount of dentin removed from the root canals during the instrumentation by using cone beam computed tomography. The number of separated instruments was also evaluated. Material and Methods: Mesial roots of 40 mandibular first molars were divided into 2 equal groups: crown-down sequence of Gates-Glidden (#3, #2, #1) and TripleGates burs. Cervical dentin thickness and canal area were measured before and after instrumentation by using cone beam computed tomography and image analysis software. Student’s t-test was used to determine significant differences at p<0.05. Results: No significant differences (p>0.05) were observed between the instruments, regarding the root canal area and dentin wall thickness. Conclusion: Both tested instruments used for cervical preparation were safe to be used in the mesial root canal of mandibular molars.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The radiopacity of esthetic root canal posts may impair the assessment of their fit to the root canal when using radiographic images. This study determined in vitro the radiographic density of esthetic root canal posts using digital images. Thirty-six roots of human maxillary canines were assigned to six groups (N = 6 per group): Reforpost (RP); Aestheti-Plus (AP); Reforpost MIX (RPM); D.T. Light Post (LP); Reforpost Radiopaque (RPR); and White Post DC (WP). Standardized digital images of the posts were obtained in different conditions: outside the root canal, inside the canal before and after cementation using luting material, and with a tissue simulator. Analysis of variance was used to compare the radiopacity mean values among the posts outside the root canal and among the posts under the other conditions, and the t unpaired test to compare the radiopacity between the posts and the dentin, and between the posts and the root canal space. There was no statistically significant difference in radiopacity between RP and RPM, and LP and WP. AP posts showed radiopacity values significantly lower than those for dentin. No statistically significant difference was found between posts (RP and AP) and the root canal space. A statistically significant difference was observed between the luted and non-luted posts; additionally, luted posts with and without tissue simulator showed no significant differences. Most of the cement-luted posts analyzed in this study were distinguishable from the density of adjacent dentin surfaces, allowing radiographic confirmation of the fit of the post in the canal.Clinical SignificanceThe success of using esthetic root canal posts depends mainly on the fit of the post within the canal.[1] The radiopacity of a post allows for radiographic imaging to be used to determine the fit, an important factor in a clinical perspective.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To evaluate the impact of the type of root canal preparation, intraradicular post and mechanical cycling on the fracture strength of roots. Material and Methods: Eighty human single rooted teeth were divided into 8 groups according to the instruments used for root canal preparation (manual or rotary instruments), the type of intraradicular post (fiber posts-FRC and cast post and core-CPC) and the use of mechanical cycling (MC) as follows: Manual and FRC; Manual, FRC and MC; Manual and CPC; Manual, CPC and MC; Rotary and FRC; Rotary, FRC and MC; Rotary and CPC; Rotary, CPC and MC. The filling was performed by lateral compactation. All root canals were prepared for a post with a 10 mm length, using the custom # 2 bur of the glass fiber post system. For mechanical cycling, the protocol was applied as follows: an angle of incidence of 45 degrees, 37 degrees C, 88 N, 4 Hz, 2 million pulses. All groups were submitted to fracture strength test in a 45 degrees device with 1 mm/min cross-head speed until failure occurred. Results: The 3-way ANOVA showed that the root canal preparation strategy (p<0.03) and post type (p<0.0001) affected the fracture strength results, while mechanical cycling (p=0.29) did not. Conclusion: The root canal preparation strategy only influenced the root fracture strength when restoring with a fiber post and mechanical cycling, so it does not seem to be an important factor in this scenario.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)