944 resultados para REPRODUCIBILITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The incidence of malignant mesothelioma is increasing. There is the perception that survival is worse in the UK than in other countries. However, it is important to compare survival in different series based on accurate prognostic data. The European Organisation for Research and Treatment of Cancer (EORTC) and the Cancer and Leukaemia Group B (CALGB) have recently published prognostic scoring systems. We have assessed the prognostic variables, validated the EORTC and CALGB prognostic groups, and evaluated survival in a series of 142 patients. Methods Case notes of 142 consecutive patients presenting in Leicester since 1988 were reviewed. Univariate analysis of prognostic variables was performed using a Cox proportional hazards regression model. Statistically significant variables were analysed further in a forward, stepwise multivariate model. EORTC and CALGB prognostic groups were derived, Kaplan-Meier survival curves plotted, and survival rates were calculated from life tables. Results Significant poor prognostic factors in univariate analysis included male sex, older age, weight loss, chest pain, poor performance status, low haemoglobin, leukocytosis, thrombocytosis, and non-epithelial cell type (p<0.05). The prognostic significance of cell type, haemoglobin, white cell count, performance status, and sex were retained in the multivariate model. Overall median survival was 5.9 (range 0-34.3) months. One and two year survival rates were 21.3% (95% CI 13.9 to 28.7) and 3.5% (0 to 8.5), respectively. Median, one, and two year survival data within prognostic groups in Leicester were equivalent to the EORTC and CALGB series. Survival curves were successfully stratified by the prognostic groups. Conclusions This study validates the EORTC and CALGB prognostic scoring systems which should be used both in the assessment of survival data of series in different countries and in the stratification of patients into randomised clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine whether [18F]-fluorodeoxyglucose-positron emission tomography (FDG-PET) could predict the pathological response in oesophageal cancer after only the first week of neoadjuvant chemoradiation. Thirty-two patients with localised oesophageal cancer had a pretreatment PET scan and a repeat after the first week of chemoradiation. The change in mean maximum standardised uptake value (SUV) and volume of metabolically active tissue (MTV) was compared with the tumour regression grade (TRG) in the final histology. Those who achieved a TRG of 1 and 2 were deemed responders and 3-5 nonresponders. In the responders (28%), the SUV fell from 12.6 (±6.3) to 8.1 (±2.9) after 1 week of chemoradiation (P = 0.070). In nonresponders (72%), the results were 9.7 (±5.4) and 7.1 (±3.8), respectively (P = 0.003). The MTV in responders fell from 36.6 (±22.7) to 22.3 (±10.4) cm3 (P = 0.180), while in nonresponders, this fell from 35.9 (±36.7) to 31.9 (±52.7) cm3 (P = 0.405). There were no significant differences between responders and nonresponders. The hypothesis that early repeat FDG-PET scanning may predict histomorphologic response was not proven. This may reflect an inflammatory effect of radiation that obscures tumour-specific metabolic changes at this time. This assessment may have limited application in predicting response to multimodal regimens for oesophageal cancer. © 2006 Cancer Research UK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microvessel density (MVD) is a widely used surrogate measure of angiogenesis in pathological specimens and tumour models. Measurement of MVD can be achieved by several methods. Automation of counting methods aims to increase the speed, reliability and reproducibility of these techniques. The image analysis system described here enables MVD measurement to be carried out with minimal expense in any reasonably equipped pathology department or laboratory. It is demonstrated that the system translates easily between tumour types which are suitably stained with minimal calibration. The aim of this paper is to offer this technique to a wider field of researchers in angiogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mesothelioma is a rare malignancy arising from mesothelial cells lining the pleura and peritoneum. Advances in modern technology have allowed the development of array based approaches to the study of disease allowing researchers the opportunity to study many genes or proteins in a high-throughput fashion. This review describes the current knowledge surrounding array based approaches with respect to mesothelioma research. © 2009 by the International Association for the Study of Lung Cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within– and between–day repeatability of spatial, temporal and vertical ground reaction forces measured by a treadmill system instrumented with a capacitance–based pressure platform. Methods Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM–THM–S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30–second capture period, equating to an average of 52 ± 5 steps of steady–state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between–session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. Results There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within–day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N. Conclusions The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Akt, a Serine/Threonine protein kinase, mediates growth factor-associated cell survival. Constitutive activation of Akt (phosphorylated Akt, P-Akt) has been observed in several human cancers, including lung cancer and may be associated with poor prognosis and chemotherapy and radiotherapy resistance. The clinical relevance of P-Akt in non-small cell lung cancer (NSCLC) is not well described. In the present study, we examined 82 surgically resected snap-frozen and paraffin-embedded stage I to IIIA NSCLC samples for P-Akt and Akt by Western blotting and for P-Akt by immunohistochemistry. P-Akt protein levels above the median, measured using reproducible semiquantitative band densitometry, correlated with a favorable outcome (P = 0.007). Multivariate analysis identified P-Akt as a significant independent favorable prognostic factor (P = 0.004). Although associated with a favorable prognosis, high P-Akt levels correlated with high tumor grade (P = 0.02). Adenocarcinomas were associated with low P-Akt levels (P = 0.039). Akt was not associated with either outcome or clinicopathologic variables. Cytoplasmic (CP-Akt) and nuclear (NP-Akt) P-Akt tumor cell staining was detected in 96% and 42% of cases, respectively. Both CP-Akt and NP-Akt correlated with well-differentiated tumors (P = 0.008 and 0.017, respectively). NP-Akt also correlated with nodal metastases (P = 0.022) and squamous histology (P = 0.037). These results suggest P-Akt expression is a favorable prognostic factor in NSCLC. Immunolocalization of P-Akt, however, may be relevant as NP-Akt was associated with nodal metastases, a known poor prognostic feature in this disease. P-Akt may be a potential novel therapeutic target for the management of NSCLC. © 2005 American Association for Cancer Research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Tumour necrosis (TN) is recognized to be a consequence of chronic cellular hypoxia. TN and hypoxia correlate with poor prognosis in solid tumours. Methods In a retrospective study the prognostic implications of the extent of TN was evaluated in non-small cell lung cancer (NSCLC) and correlated with clinicopathological variables and expression of epidermal growth factor receptor, Bcl-2, p53 and matrix metalloproteinase-9 (MMP-9). Tissue specimens from 178 surgically resected cases of stage I-IIIA NSCLC with curative intent were studied. The specimens were routinely processed, formalin-fixed and paraffin-embedded. TN was graded as extensive or either limited or absent by two independent observers; disagreements were resolved using a double-headed microscope. The degree of reproducibility was estimated by re-interpreting 40 randomly selected cases after a 4 month interval. Results Reproducibility was attained in 36/40 cases, Kappa score=0.8 P<0.001. TN correlated with T-stage (P=0.001), platelet count (P=0.004) and p53 expression (P=0.031). Near significant associations of TN with N-stage (P=0.063) and MMP-9 expression (P=0.058) were seen. No association was found with angiogenesis (P=0.98). On univariate (P=0.0016) and multivariate analysis (P=0.023) TN was prognostic. Conclusion These results indicate that extensive TN reflects an aggressive tumour phenotype in NSCLC and may improve the predictive power of the TMN staging system. The lack of association between TN and angiogenesis may be important although these variables were not evaluated on serial sections. © 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Changes in the molecular structure of polymer antioxidants such as hindered amine light stabilisers (HALS) is central to their efficacy in retarding polymer degradation and therefore requires careful monitoring during their in-service lifetime. The HALS, bis-(1-octyloxy-2,2,6,6-tetramethyl-4-piperidinyl) sebacate (TIN123) and bis-(1,2,2,6,6-pentamethyl-4-piperidinyl) sebacate (TIN292), were formulated in different polymer systems and then exposed to various curing and ageing treatments to simulate in-service use. Samples of these coatings were then analysed directly using liquid extraction surface analysis (LESA) coupled with a triple quadrupole mass spectrometer. Analysis of TIN123 formulated in a cross-linked polyester revealed that the polymer matrix protected TIN123 from undergoing extensive thermal degradation that would normally occur at 292 degrees C, specifically, changes at the 1- and 4-positions of the piperidine groups. The effect of thermal versus photo-oxidative degradation was also compared for TIN292 formulated in polyacrylate films by monitoring the in situ conversion of N-CH3 substituted piperidines to N-H. The analysis confirmed that UV light was required for the conversion of N-CH3 moieties to N-H - a major pathway in the antioxidant protection of polymers - whereas this conversion was not observed with thermal degradation. The use of tandem mass spectrometric techniques, including precursor-ion scanning, is shown to be highly sensitive and specific for detecting molecular-level changes in HALS compounds and, when coupled with LESA, able to monitor these changes in situ with speed and reproducibility. (C) 2013 Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Since 1992 there have been several articles published on research on plastic scintillators for use in radiotherapy. Plastic scintillators are said to be tissue equivalent, temperature independent and dose rate independent [1]. Although their properties were found to be promising for measurements in megavoltage X-ray beams there were some technical difficulties with regards to its commercialisation. Standard Imaging has produced the first commercial system which is now available for use in a clinical setting. The Exradin W1 scintillator device uses a dual fibre system where one fibre is connected to the Plastic Scintillator and the other fibre only measures Cerenkov radiation [2]. This paper presents results obtained during commissioning of this dosimeter system. Methods All tests were performed on a Novalis Tx linear accelerator equipped with a 6 MV SRS photon beam and conventional 6 and 18 MV X-ray beams. The following measurements were performed in a Virtual Water phantom at a depth of dose maximum. Linearity: The dose delivered was varied between 0.2 and 3.0 Gy for the same field conditions. Dose rate dependence: For this test the repetition rate of the linac was varied between 100 and 1,000 MU/min. A nominal dose of 1.0 Gy was delivered for each rate. Reproducibility: A total of five irradiations for the same setup. Results The W1 detector gave a highly linear relationship between dose and the number of Monitor Units delivered for a 10 9 10 cm2 field size at a SSD of 100 cm. The linearity was within 1 % for the high dose end and about 2 % for the very low dose end. For the dose rate dependence, the dose measured as a function of repetition the rate (100–1,000 MU/min) gave a maximum deviation of 0.9 %. The reproducibility was found to be better than 0.5 %. Discussion and conclusions The results for this system look promising so far being a new dosimetry system available for clinical use. However, further investigation is needed to produce a full characterisation prior to use in megavoltage X-ray beams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Wearable monitors are increasingly being used to objectively monitor physical activity in research studies within the field of exercise science. Calibration and validation of these devices are vital to obtaining accurate data. This article is aimed primarily at the physical activity measurement specialist, although the end user who is conducting studies with these devices also may benefit from knowing about this topic. Best Practices Initially, wearable physical activity monitors should undergo unit calibration to ensure interinstrument reliability. The next step is to simultaneously collect both raw signal data (e.g., acceleration) from the wearable monitors and rates of energy expenditure, so that algorithms can be developed to convert the direct signals into energy expenditure. This process should use multiple wearable monitors and a large and diverse subject group and should include a wide range of physical activities commonly performed in daily life (from sedentary to vigorous). Future Directions New methods of calibration now use "pattern recognition" approaches to train the algorithms on various activities, and they provide estimates of energy expenditure that are much better than those previously available with the single-regression approach. Once a method of predicting energy expenditure has been established, the next step is to examine its predictive accuracy by cross-validating it in other populations. In this article, we attempt to summarize the best practices for calibration and validation of wearable physical activity monitors. Finally, we conclude with some ideas for future research ideas that will move the field of physical activity measurement forward.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many countries conduct regular national time use surveys, some of which date back as far as the 1960s. Time use surveys potentially provide more detailed and accurate national estimates of the prevalence of sedentary and physical activity behavior than more traditional self-report surveillance systems. In this study, the authors determined the reliability and validity of time use surveys for assessing sedentary and physical activity behavior. In 2006 and 2007, participants (n = 134) were recruited from work sites in the Australian state of New South Wales. Participants completed a 2-day time use diary twice, 7 days apart, and wore an accelerometer. The 2 diaries were compared for test-retest reliability, and comparison with the accelerometer determined concurrent validity. Participants with similar activity patterns during the 2 diary periods showed reliability intraclass correlations of 0.74 and 0.73 for nonoccupational sedentary behavior and moderate/vigorous physical activity, respectively. Comparison of the diary with the accelerometer showed Spearman correlations of 0.57-0.59 and 0.45-0.69 for nonoccupational sedentary behavior and moderate/vigorous physical activity, respectively. Time use surveys appear to be more valid for population surveillance of nonoccupational sedentary behavior and health-enhancing physical activity than more traditional surveillance systems. National time use surveys could be used to retrospectively study nonoccupational sedentary and physical activity behavior over the past 5 decades.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the validity of the ActiGraph accelerometer for the measurement of physical activity intensity in children and adolescents with cerebral palsy (CP) using oxygen uptake (VO 2) as the criterion measure. Thirty children and adolescents with CP (mean age 12.6 ± 2.0 years) wore an ActiGraph 7164 and a Cosmed K4b 2 portable indirect calorimeter during four activities; quiet sitting, comfortable paced walking, brisk paced walking and fast paced walking. VO 2 was converted to METs and activity energy expenditure and classiWed as sedentary, light or moderate-to-vigorous intensity according to the conventions for children. Mean ActiGraph counts min -1 were classiWed as sedentary, light or moderate-to-vigorous (MVPA) intensity using four diVerent sets of cut-points. VO 2 and counts min¡1 increased signiWcantly with increases in walking speed (P < 0.001). Receiver operating characteristic (ROC) curve analysis indicated that, of the four sets of cut-points evaluated, the Evenson et al. (J Sports Sci 26(14):1557-1565, 2008) cut-points had the highest classiWcation accuracy for sedentary (92%) and MVPA (91%), as well as the second highest classiWcation accuracy for light intensity physical activity (67%). A ROC curve analysis of data from our participants yielded a CP-speciWc cut-point for MVPA that was lower than the Evenson cut-point (2,012 vs. 2,296 counts min¡1), however, the diVerence in classiWcation accuracy was not statistically signiWcant 94% (95% CI = 88.2-97.7%) vs. 91% (95% CI = 83.5-96.5%). In conclusion, among children and adolescents with CP, the ActiGraph is able to diVerentiate between diVerent intensities of walking. The use of the Evenson cut-points will permit the estimation of time spent in MVPA and allows comparisons to be made between activity measured in typically developing adolescents and adolescents with CP. © 2011 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the research was to determine the optimal location and method of attachment for accelerometer-based motion sensors, and to validate their ability to differentiate rest and increases in speed in healthy dogs moving on a treadmill. Two accelerometers were placed on a harness between the scapulae of dogs with one in a pouch and one directly attached to the harness. Two additional accelerometers were placed (pouched and not pouched) ventrally on the dog's collar. Data were recorded in 1. s epochs with dogs moving in stages lasting 3. min each on a treadmill: (1) at rest, lateral recumbency, (2) treadmill at 0% slope, 3. km/h, (3) treadmill at 0% slope, 5. km/h, (4) treadmill at 0% slope, 7. km/h, (5) treadmill at 5% slope, 5. km/h, and; (6) treadmill at 5% slope, 7. km/h. Only the harness with the accelerometer in a pouch along the dorsal midline yielded statistically significant increases (P< 0.05) in vector magnitude as walking speed of the dogs increased (5-7. km/h) while on the treadmill. Statistically significant increases in vector magnitude were detected in the dogs as the walking speed increased from 5 to 7. km/h, however, changes in vector magnitude were not detected when activity intensity was increased as a result of walking up a 5% grade. Accelerometers are a valid and objective tool able to discriminate between and monitor different levels of activity in dogs in terms of speed of movement but not in energy expenditure that occurs with movement up hill.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Invasion of extracellular matrices is crucial to a number of physiological and pathophysiological states, including tumor cell metastasis, arthritis, embryo implantation, wound healing, and early development. To isolate invasion from the additional complexities of these scenarios a number of in vitro invasion assays have been developed over the years. Early studies employed intact tissues, like denuded amniotic membrane (1) or embryonic chick heart fragments (2), however recently, purified matrix components or complex matrix extracts have been used to provide more uniform and often more rapid analyses (for examples, see the following integrin studies). Of course, the more holistic view of invasion offered in the earlier assays is valuable and cannot be fully reproduced in these more rapid assays, but advantages of reproducibility among replicates, ease of preparation and analysis, and overall high throughput favor the newer assays. In this chapter, we will focus on providing detailed protocols for Matrigel-based assays (Matrigel=reconstituted basement membrane; reviewed in ref. (3)). Matrigel is an extract from the transplantable Engelbreth-Holm-Swarm murine sarcoma that deposits a multilammelar basement membrane. Matrigel is available commercially (Becton Dickinson, Bedford, MA), and can be manipulated as a liquid at 4°C into a variety of different formats. Alternatively, cell culture inserts precoated with Matrigel can be purchased for even greater simplicity.