966 resultados para Próteses e implantes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pesquisa teve como objetivo determinar as forças de mordida de 73 indivíduos, por meio de um gnatodinamômetro. Os pacientes eram portadores de próteses parciais removíveis inferiores classes I, II ou III. A arcada antagonista era prótese, parcial removível ou fixa, ou total. Os resultados permitiram concluir que: as selas de extremidade livre, principalmente em suas posições extremas, conduziram a forças de mordida muito baixas; o envolvimento de prótese total, também, conduziu a forças de mordida baixas; o sexo masculino alcançou valores maiores que o feminino; com prótese parcial removível classe III, os dentes naturais molares e pré-molares desenvolveram valores maiores do que com classes I e II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welding in the dentistry has been used for great part of the specialized dentist-surgeons in the implants area to solve prosthesis supported by implant adaptation problems. The development of new equipments Laser and TIG allowed a larger use of these processes in the prosthesis production. In this work, it was studied welded joints made by Laser and TIG, using commercial purity titanium, cpTi, applied in prosthesis supported by implants. The weld characterizations were carried out by light microscopy, EDS_elementary mapping, microhardness and tensile test. Through metallographic characterization, the weld bead presented a martensitic microstructure in the Laser welding process, originated from shear provoked by deformations in the lattice. This caused structural changes of the transformed area, which determines a fine plate-like morphology. In the weld bead from TIG, besides presenting higher hardness, was observed formation of Widmansttaten structure, which is characteristic of a geometric model, resulted of new phase formation along of the crystallographic plans. The martensitic structure is more refined than Widmansttaten structure, due to the high-speed cooling (10(3)degrees C/s) imposed by the Laser process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors verified histologically in 20 no dentates patients, the influence of complete dentures on the hard palate mucosa. The patients were divided in two groups: I. Patients that never used complete dentures; II. Patients that were using complete dentures when this research was realized. New prosthesis were made for each one of the 20 patients. Immediately before they received the new prosthesis and ninety days after this, biopsies were realized. The circunferencial pieces of the hard palate mucosa were fixed in formol 10% and coloured with Hematoxylin/Eosin and Mallory's Tricomic for histomorphologic analysis and measuring of the stratum corneum of the epithelium. It was made the statistical analysis and the results showed that: 1. In normal conditions, the utilization of the full dentures produces the reduce of the thickness of the stratum corneum. This was more observed in Group I. 2. The range difference of the thickness of the stratum corneum between the first and the second biopsies in the groups I and II (4.86 microns and 2.18 microns) were not statistically significant. 3. With the use of complete dentures the stratum corneum of the epithelium showed tendence to parakeratinization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histopathology by hematoxilin-eosin (HE) and periodic acid Schiff (PAS), concomitant direct immunofluorescence (DI) against total human immunoglobulins and against Candida albicans, was effectuated in 25 persons dentures wearers. In 5 persons without chronic athrofic candidiasis (CAC) clinical signals in the palate the HE showed wise inflammatory elements in the connective tissue and the PAS marked the continuous basal layer, the intra-cellular grains of granular layer and the uniform parakeratin on epithelial surface. In 20 others, with palatal signals of CAC, in the HE was frequent the features encountered in Candida infected and PAS revealed, beside descontinuous lamina basal and epithelial surface covered by tide and discontinuous parakeratin, the presence of round bodies few largers that presents in the granular layer, casually isolated in the medial portion of ret pegs and connective papillae. In the first 5 persons the DI against total human immunoglobulins not showed signals of the humoral immunologic phenomena, the same was valid to others 20 patients with CAC clinical aspects. However the DI with conjugate against C. albicans in the 20 cases with CAC signals revealed suitable aspects of the structures assumed by Candida in tissues. Cultures of samples obtained of the persons with CAC signals was positive in 100% to Candida, 70% presumptively albicans, against 80% of positiviness to generus Candida, 67% presumptively albicans, in the persons without CAC signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors analysed the simultaneous effects of the dimensional and weight alteration of resins utilized for esthetic facets submitted to warehousing conditions and periods of time. The resins showed different behaviour and a neat correlation between dimensional alteration and weight. The condition of immersion promoted dimensional alteration 50% lower and an alteration of weight three times higher.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the chemical structure, the microstructure and the surface morphology of two non-ferrous materials used in dental implants (Ti-6Al-4V and Co-Cr-Mo) were studied. This was done by chemical analysis, scanning electron microscopy (SEM), energy disperse spectroscopy (EDS), and strength measurements (HV). Metallographic studies reveal that titanium alloy surface present a fine granular binary phase structure, while cobalt alloy present cast dendrite structures with an intense precipitation of carbides. To correlate the macro and microstructure with the mechanical behavior of the material, microhardness measurements were performed. Using the Vickers hardening method, the Ti-6Al-4V alloy yielded strength mean values smaller than the Co-Cr-Mo alloy. Their values are associated to the chemical composition and to the microstructural distribution of these materials. The Ti-6Al-4V alloy presents hardness similar to dental enamel, which suggests better performance as dental implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ASTM F 138 austenitic stainless steel is extensively used as an orthopedic implant material. However, some aspects, such as low strength in the annealed condition and susceptibility to localized corrosion, limit wider use of this kind of steel. Recently, a high-nitrogen austenitic stainless steel, specified in the standard ISO 5832-9, has been indicated as an alternative to ASTM F 138 steel for more severe loading and permanent application inside the human body. In this work, microstructure, mechanical properties, corrosion resistance and fatigue behavior of both steels were determined and compared. ISO 5832-9 steel displayed better mechanical and corrosion behaviors than did ASTM F 138 steel The combination of these features lead ISO steel to enhanced fatigue performance in both neutral and aggressive environments. Analyzed were the role of nitrogen in solid solution, combined with niobium in the Z-phase, and the factors that led to superior ISO 5832-9 properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of techniques to reach aesthetics in the anterior region when using osseointegrated implants is of great importance. A literature review was made to compare effivciency and suitability of immediate provisionalization in re-opening of osseointegrated implants with respect to the set time (use of standardized cicatrizants and emergency profile cicatrizants). Immediate provisional denture in the phase of re-opening makes the restoration of the gingival contourn quicker when compared to the use of cicatrizants without intermediate phases required. © 2008 1995, Editorial Ciencias médicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. Methods: A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the Faculdade de Medicina de Botucatu-UNESP. Results: Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants. Conclusion: Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the number of occlusal contacts achieved in temporal prostheses mounted in a semi-adjusted articulator using the facial arch and the Camper plane. Ten patients treated in a private clinic were selected to be rehabilitated with prostheses in previously placed single implants. For each patient two temporal prostheses were designed obtained under different conditions: (1) model mounting using facial arch and (2) Camper plane mounting. Prostheses were made and adjusted in the laboratory and placed only by an operator. The occlusal contacts achieved in each condition were photographed being assessed and quantified by a second professional not involved with the mounting conditions. Results obtained were analyzed by Mann-Whitney test with a 5 % significance level. There was not a statistically difference between the number of occlusal contacts when prostheses were made with facial arch or Camper plane (p= 0.113). The temporal dental prosthesis confection for single implants, semi-adjusted articulator using the Camper plane, not differ very much from the facial arch use, according to the number of resulting occlusal contacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implants are usually used after removal of the eye or its internal content, in order to maintain the orbital volume or, as in medicine, provide also the subsequent placement of ocular prosthesis. Considering prosthetic surgery procedures of high relevance in human and veterinary ophthalmology, this paper seek to review the main types of implants described in national and international literature, as well as describe the main complications when they are used in humans and veterinary patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the majority of cases of bone fracture requiring surgery, orthopedic implants (screw-plate and screw) are used for osteosynthesis and the infections associated with such implants are due to the growth of microorganisms in biofilms. The objective of this study was to identify microorganisms recovered from osteosynthesis implants used to fix bone fractures, to assess the viability of the cells and the ability of staphylococci to adhere to a substrate and to determine their sensitivity/resistance to antimicrobials. After surgical removal, the metal parts of austenitic stainless steel (ASTM F138/F139 or ISO NBR 5832-1/9) were transported to the Laboratory of Clinical Microbiology, washed in buffer and subjected to ultrasonic bath at 40±2 kHz for 5 minutes. The sonicated fluid was used to seed solid culture media and cell viability was assessed under the microscope by with the aid of a fluorescent marker. The production of extracellular polysaccharide by Staphylococcus spp. was investigated by means of adhesion to a polystyrene plate. The profile of susceptibility to antimicrobials was determined by the disk diffusion assay. The most frequently isolated bacteria included coagulase-negative Staphylococcus resistant to erythromycin, clindamycin and oxacillin. Less frequent were Pseudomonas aeruginosa resistant to trimethoprim/sulfamethoxazole and ampicillin, Acinetobacter baumannii resistant to ceftazidime, Enterobacter cloacae resistant to cephalothin, cefoxitin, cefazolin, levofloxacin and ciprofloxacin, Bacillus spp. and Candida tropicalis. The observation of slides by fluorescence microscope showed clusters of living cells embedded in a transparent matrix. The test for adherence of coagulase-negative Staphylococcus to a polystyrene plate showed that these microorganisms produce extracellular polysaccharide. In conclusion, the metal parts were colonized by bacteria related to orthopedic implant infection, which were resistant to multiple antibiotics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC