962 resultados para Power Spectral-analysis


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the doctoral dissertation, low-voltage direct current (LVDC) distribution system stability, supply security and power quality are evaluated by computational modelling and measurements on an LVDC research platform. Computational models for the LVDC network analysis are developed. Time-domain simulation models are implemented in the time-domain simulation environment PSCAD/EMTDC. The PSCAD/EMTDC models of the LVDC network are applied to the transient behaviour and power quality studies. The LVDC network power loss model is developed in a MATLAB environment and is capable of fast estimation of the network and component power losses. The model integrates analytical equations that describe the power loss mechanism of the network components with power flow calculations. For an LVDC network research platform, a monitoring and control software solution is developed. The solution is used to deliver measurement data for verification of the developed models and analysis of the modelling results. In the work, the power loss mechanism of the LVDC network components and its main dependencies are described. Energy loss distribution of the LVDC network components is presented. Power quality measurements and current spectra are provided and harmonic pollution on the DC network is analysed. The transient behaviour of the network is verified through time-domain simulations. DC capacitor guidelines for an LVDC power distribution network are introduced. The power loss analysis results show that one of the main optimisation targets for an LVDC power distribution network should be reduction of the no-load losses and efficiency improvement of converters at partial loads. Low-frequency spectra of the network voltages and currents are shown, and harmonic propagation is analysed. Power quality in the LVDC network point of common coupling (PCC) is discussed. Power quality standard requirements are shown to be met by the LVDC network. The network behaviour during transients is analysed by time-domain simulations. The network is shown to be transient stable during large-scale disturbances. Measurement results on the LVDC research platform proving this are presented in the work.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the present study, using noise-free simulated signals, we performed a comparative examination of several preprocessing techniques that are used to transform the cardiac event series in a regularly sampled time series, appropriate for spectral analysis of heart rhythm variability (HRV). First, a group of noise-free simulated point event series, which represents a time series of heartbeats, was generated by an integral pulse frequency modulation model. In order to evaluate the performance of the preprocessing methods, the differences between the spectra of the preprocessed simulated signals and the true spectrum (spectrum of the model input modulating signals) were surveyed by visual analysis and by contrasting merit indices. It is desired that estimated spectra match the true spectrum as close as possible, showing a minimum of harmonic components and other artifacts. The merit indices proposed to quantify these mismatches were the leakage rate, defined as a measure of leakage components (located outside some narrow windows centered at frequencies of model input modulating signals) with respect to the whole spectral components, and the numbers of leakage components with amplitudes greater than 1%, 5% and 10% of the total spectral components. Our data, obtained from a noise-free simulation, indicate that the utilization of heart rate values instead of heart period values in the derivation of signals representative of heart rhythm results in more accurate spectra. Furthermore, our data support the efficiency of the widely used preprocessing technique based on the convolution of inverse interval function values with a rectangular window, and suggest the preprocessing technique based on a cubic polynomial interpolation of inverse interval function values and succeeding spectral analysis as another efficient and fast method for the analysis of HRV signals

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the effects of aerobic physical training (APT) on heart rate variability (HRV) and cardiorespiratory responses at peak condition and ventilatory anaerobic threshold. Ten young (Y: median = 21 years) and seven middle-aged (MA = 53 years) healthy sedentary men were studied. Dynamic exercise tests were performed on a cycloergometer using a continuous ramp protocol (12 to 20 W/min) until exhaustion. A dynamic 24-h electrocardiogram was analyzed by time (TD) (standard deviation of mean R-R intervals) and frequency domain (FD) methods. The power spectral components were expressed as absolute (a) and normalized units (nu) at low (LF) and high (HF) frequencies and as the LF/HF ratio. Control (C) condition: HRV in TD (Y: 108, MA: 96 ms; P<0.05) and FD - LFa, HFa - was significantly higher in young (1030; 2589 ms²/Hz) than in middle-aged men (357; 342 ms²/Hz) only during sleep (P<0.05); post-training effects: resting bradycardia (P<0.05) in the awake condition in both groups; VO2 increased for both groups at anaerobic threshold (P<0.05), and at peak condition only in young men; HRV in TD and FD (a and nu) was not significantly changed by training in either groups. The vagal predominance during sleep is reduced with aging. The resting bradycardia induced by short-term APT in both age groups suggests that this adaptation is much more related to intrinsic alterations in sinus node than in efferent vagal-sympathetic modulation. Furthermore, the greater alterations in VO2 than in HRV may be related to short-term APT.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Physical exercise is associated with parasympathetic withdrawal and increased sympathetic activity resulting in heart rate increase. The rate of post-exercise cardiodeceleration is used as an index of cardiac vagal reactivation. Analysis of heart rate variability (HRV) and complexity can provide useful information about autonomic control of the cardiovascular system. The aim of the present study was to ascertain the association between heart rate decrease after exercise and HRV parameters. Heart rate was monitored in 17 healthy male subjects (mean age: 20 years) during the pre-exercise phase (25 min supine, 5 min standing), during exercise (8 min of the step test with an ascending frequency corresponding to 70% of individual maximal power output) and during the recovery phase (30 min supine). HRV analysis in the time and frequency domains and evaluation of a newly developed complexity measure - sample entropy - were performed on selected segments of heart rate time series. During recovery, heart rate decreased gradually but did not attain pre-exercise values within 30 min after exercise. On the other hand, HRV gradually increased, but did not regain rest values during the study period. Heart rate complexity was slightly reduced after exercise and attained rest values after 30-min recovery. The rate of cardiodeceleration did not correlate with pre-exercise HRV parameters, but positively correlated with HRV measures and sample entropy obtained from the early phases of recovery. In conclusion, the cardiodeceleration rate is independent of HRV measures during the rest period but it is related to early post-exercise recovery HRV measures, confirming a parasympathetic contribution to this phase.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX® signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 ± 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The main purpose ofthis study was to examine the effect ofintention on the sleep onset process from an electrophysiological point ofview. To test this, two nap conditions, the Multiple Sleep Latency Test (MSLT) and the Repeated Test of Sustained Wakefulness (RTSW) were used to compare intentional and inadvertent sleep onset. Sixteen female participants (aged 19-25) spent two non-consecutive nights in the sleep lab; however, due to physical and technical difficulties only 8 participants produced compete sets of data for analysis. Each night participants were given six nap opportunities. For three ofthese naps they were instructed to fall asleep (MSLT), for the remaining three naps they were to attempt to remain awake (RTSW). These two types of nap opportunities represented the conditions ofintentional (MSLT) and inadvertent (RTSW) sleep onset. Several other sleepiness, performance, arousal and questionnaire measures were obtained to evaluate and/or control for demand characteristics, subjective effort and mental activity during the nap tests. The nap opportunities were scored using a new 9 stage scoring system developed by Hori et al. (1994). Power spectral analyses (FFT) were also performed on the sleep onset data provided by the two nap conditions. Longer sleep onset latencies (approximately 1.25 minutes) were obseIVed in the RTSW than the MSLT. A higher incidence of structured mental activity was reported in the RTSW and may have been reflected in higher Beta power during the RTSW. The decent into sleep was more ragged in the RTSW as evidenced by an increased number shifts towards higher arousal as measured using the Hori 9 stage sleep scoring method. 1ll The sleep onset process also appears to be altered by the intention to remain awake, at least until the point ofinitial Stage 2 sleep (i.e. the first appearance of spindle activity). When only examining the final 4.3 minutes ofthe sleep onset process (ending with spindle activity), there were significant interactions between the type ofnap and the time until sleep onset for Theta, Alpha and Beta power. That is to say, the pattern of spectral power measurements in these bands differed across time as a function ofthe type ofnap. The effect ofintention however, was quite small (,,2 < .04) when compared to the variance which could be accounted for by the passage oftime (,,2 == .10 to .59). These data indicate that intention alone cannot greatly extend voluntary wakefulness if a person is sleepy. This has serious implications for people who may be required to perform dangerous tasks while sleepy, particularly for people who are in a situation that does not allow them the opportunity to engage in behavioural strategies in order to maintain their arousal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Vagal baroreflex sensitivity (BRS) is a measure of short term blood pressure (BP) regulation through alterations in heart rate. Low BRS reflects impaired autonomic system regulation and has been found to be a surrogate marker for cardiovascular health. In particular, it has found to be associated with the pathogenesis of adult hypertension. However, only limited information exists as to the negative consequences of childhood BP on baroreflex function. The objective of this study was to investigate BRS in children with 2 different BP profiles while controlling for the effects of age, maturation, sex, and body composition. A preliminary subsample of 11-14 year-old children from the HBEAT (Heart Behavioural Environmental Assessment Team) Study was selected. The children were divided into 2 BP groups; high BP (HBP; 2:95tl1 percentile, n=21) and normal BP (NBP; <90th percentile, n=85). Following an initial 15 minutes of supine rest, 5 minutes of continuous beat-to-beat BP (Finapres) and RR interval (RRI) were recorded (standard ECG). Spectral indices were computed using Fast Fourier Transform and transfer function analysis was used to compute BRS. High frequency (HF) and low frequency (LF) power spectral areas were set to 0.15-0.4 Hz and 0.04-0.15 Hz, respectively. Body composition was measured using body mass index. After adjusting for body composition, maturation, age and sex ANCOV A results were as follows; LF and HF BRS, LF and HF RRI, and RRI total power were lower in the HBP versus NBP participants (p<0.05). As well, LF IHF SBP ratio was significantly higher in the HBP compared to the NBP group (p<0.05). The regression coefficients (unstandardized B) indicated that in changing groups (NBP to HBP) LF and HF BRS decreases by 4.04 and 6.18 ms/mmHg, respectively. Thus, as BP increases, BRS decreases. These data suggest that changes in autonomic activity occur in children who have HBP, regardless of age, sex, maturation, and body composition. Thus, despite their young age and relatively short amount of time having high BP compared with adults, these children are already demonstrating poor BP regulation and reduced cardiovagal activity. Given that childhood BP is associated with hypertension in adulthood, there is a growing concern in regards to the current cardiovascular health of our children and future adults.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Developmental coordination disorder (DCD) is a motor coordination disorder that is characterized by impairment of motor skills which leads to challenges with performing activities of daily living. Children with DCD have been shown to be less physically active and have increased body fatness. This is an important finding since a sedentary lifestyle and obesity are risk factors for cardiovascular disease. One indicator of cardiovascular health is baroreflex sensitivity (BRS), which is a measure of short term BP regulation that is accomplished through changes in HR. Diminished BRS is predictive of cardiovascular morbidity and mortality. The purpose of this study was to investigate BRS in 117 children aged 12 to 13 years with probable DCD (pOCO) and their matched controls with normal coordination. Following 15 minutes of supine rest, five minutes of continuous beat-by-beat blood pressure (Finapres) and RR interval were recorded (standard ECG). Spectral indices were computed using Fast Fourier Transform and transfer function analysis was used to compute BRS. High frequency and low frequency power spectral areas were set to 0.15-0.6 Hz and 0.04-0.15 Hz, respectively. BRS was compared between groups with an independent t-test and the difference was not significant. It is likely that a difference in BRS was not seen between groups since the difference in BMI between groups was small. As well, differences in BRS may not have manifested yet at this early age. However, the cardiovascular health of this population still deserves attention since differences in body composition and fitness were found between groups.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Le trouble comportemental en sommeil paradoxal (TCSP) est une parasomnie se caractérisant par la perte de l’atonie musculaire, la paralysie qui accompagne généralement le sommeil paradoxal, suivie de l’apparition de comportements indésirables et souvent violents. Des études suggèrent que le TCSP idiopathique (TCSPi) est fortement lié au développement ultérieur de la maladie de Parkinson, de la démence à corps de Lewy et de l’atrophie multisystémique. En effet, des signes subtils de neurodégénérescence sont observés chez ces patients, notamment un ralentissement de l’activité électrique cérébrale (EEG) à l’éveil et la présence de troubles cognitifs. Le but de cette thèse est 1) d’évaluer sur le plan transversal la contribution du trouble cognitif léger (TCL) dans le ralentissement de l’EEG à l’éveil observé chez ces patients et 2) d’évaluer la valeur prédictive des mesures de l’EEG à l’éveil mesurées au temps de base par rapport au développement d’une maladie neurodégénérative (MND) lors du suivi longitudinal. Dans le cadre de la première étude, l’EEG à l’éveil d’un groupe de patients avec un TCSPi présentant des atteintes cognitives a été comparé à celui d’un groupe de patients sans troubles cognitifs et à des sujets témoins sains. Seuls les patients avec un TCL affichaient un ralentissement de l’EEG d’éveil plus prononcé au niveau postérieur, c’est-à-dire une puissance relative thêta plus élevée dans les régions pariétale, temporale et occipitale, une puissance relative alpha plus faible dans les régions occipitale et temporale, en plus d’un ratio spectral (ondes lentes sur ondes rapides) plus élevé dans ces régions en comparaison avec les deux autres groupes. De plus, le ratio spectral corrélait négativement avec les fonctions attentionnelles/exécutives, visuospatiales et la mémoire épisodique verbale. La deuxième étude a quant à elle évalué l’EEG à l’éveil au temps initial de patients qui ont développé une MND sur une période de 3,5 ans en comparaison à celui de patients qui sont demeurés idiopathiques et à un groupe de témoins sains. Les patients avec un TCSPi qui ont évolué vers une MND présentaient une augmentation de la puissance de l’activité absolue delta et thêta, en plus d’un ratio spectral plus élevé dans les cinq régions corticales en comparaison avec les deux autres groupes. Cette thèse suggère ainsi que le ralentissement de l’EEG à l’éveil dans le TCSPi est relié à la présence d’un TCL concomitant. De plus, ces anomalies sont associées à un plus grand risque de développer une maladie de Parkinson, une démence à corps de Lewy ou une atrophie multisystémique à court terme chez ces patients. Le ralentissement de l’EEG à l’éveil semble donc être un marqueur prometteur d’une neurodégénérescence cérébrale plus sévère chez les patients souffrant d’un TCSPi.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The rapid developments in fields such as fibre optic communication engineering and integrated optical electronics have expanded the interest and have increased the expectations about guided wave optics, in which optical waveguides and optical fibres play a central role. The technology of guided wave photonics now plays a role in generating information (guided-wave sensors) and processing information (spectral analysis, analog-to-digital conversion and other optical communication schemes) in addition to its original application of transmitting information (fibre optic communication). Passive and active polymer devices have generated much research interest recently because of the versatility of the fabrication techniques and the potential applications in two important areas – short distant communication network and special functionality optical devices such as amplifiers, switches and sensors. Polymer optical waveguides and fibres are often designed to have large cores with 10-1000 micrometer diameter to facilitate easy connection and splicing. Large diameter polymer optical fibres being less fragile and vastly easier to work with than glass fibres, are attractive in sensing applications. Sensors using commercial plastic optical fibres are based on ideas already used in silica glass sensors, but exploiting the flexible and cost effective nature of the plastic optical fibre for harsh environments and throw-away sensors. In the field of Photonics, considerable attention is centering on the use of polymer waveguides and fibres, as they have a great potential to create all-optical devices. By attaching organic dyes to the polymer system we can incorporate a variety of optical functions. Organic dye doped polymer waveguides and fibres are potential candidates for solid state gain media. High power and high gain optical amplification in organic dye-doped polymer waveguide amplifier is possible due to extremely large emission cross sections of dyes. Also, an extensive choice of organic dye dopants is possible resulting in amplification covering a wide range in the visible region.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this thesis, we present the results of our investigations on the photoconducting and electrical switching properties of selected chalcogenide glass systems. We have used XRD and X-ray photoelectron spectroscopy (XPS) analysis for confinuing the amorphous nature of these materials and for confirming their constituents respectively.Photoconductivity is the enhancement in electrical conductivity of materials brought about by the motion of charge carriers excited by absorbed radiation. The phenomenon involves absorption, photogeneration, recombination and transport processes and it gives good insight into the density of states in the energy gap of solids due to the presence of impurities and lattice defects. Photoconductivity measurements lead to the determination of such important parameters as quantum efficiency, photosensiti\'ity, spectral sensitivity and carrier lifetime. Extensive research work on photoconducting properties of amorphous semiconductors has resulted in the development of a variety of very sensitive photodetectors. Photoconductors are finding newer and newer uses eyery day. CdS, CdSe. Sb2S3, Se, ZnO etc, are typical photoconducting materials which are used in devices like vidicons, light amplifiers, xerography equipment etc.Electrical switching is another interesting and important property possessed by several Te based chalcogenides. Switching is the rapid and reversible transition between a highly resistive OFF state, driven by an external electric field and characterized by a threshold voltage, and a low resistivity ON state, Switching can be either threshold type or memory type. The phenomenon of switching could find applications in areas like infonnation storage, electrical power control etc. Investigations on electrical switching in chalcogenide glasses help in understanding the mechanism of switching which is necessary to select and modify materials for specific switching applications.Analysis of XRD pattern gives no further infonuation about amorphous materials than revealing their disordered structure whereas x-ray photoelectron spectroscopy,XPS) provides information about the different constituents present in the material. Also it gives binding energies (b.e.) of an element in different compounds and hence b.e. shift from the elemental form.Our investigations have been concentrated on the bulk glasses, Ge-In-Se, Ge-Bi-Se and As-Sb-Se for photoconductivity measurements and In-Te for electrical switching. The photoconducting properties of Ge-Sb-Se thin films prepared by sputtering technique have also been studied. The bulk glasses for the present investigations are prepared by the melt quenching technique and are annealed for half an hour at temperatures just below their respective glass transition temperatures. The dependence of photoconducting propenies on composition and temperature are investigated in each system. The electrical switching characteristics of In-Te system are also studied with different compositions and by varying the temperature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Artificial neural networks (ANNs) are relatively new computational tools that have found extensive utilization in solving many complex real-world problems. This paper describes how an ANN can be used to identify the spectral lines of elements. The spectral lines of Cadmium (Cd), Calcium (Ca), Iron (Fe), Lithium (Li), Mercury (Hg), Potassium (K) and Strontium (Sr) in the visible range are chosen for the investigation. One of the unique features of this technique is that it uses the whole spectrum in the visible range instead of individual spectral lines. The spectrum of a sample taken with a spectrometer contains both original peaks and spurious peaks. It is a tedious task to identify these peaks to determine the elements present in the sample. ANNs capability of retrieving original data from noisy spectrum is also explored in this paper. The importance of the need of sufficient data for training ANNs to get accurate results is also emphasized. Two networks are examined: one trained in all spectral lines and other with the persistent lines only. The network trained in all spectral lines is found to be superior in analyzing the spectrum even in a noisy environment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Swift heavy ion induced changes in microstructure and surface morphology of vapor deposited Fe–Ni based metallic glass thin films have been investigated by using atomic force microscopy, X-ray diffraction and transmission electron microscopy. Ion beam irradiation was carried out at room temperature with 103 MeV Au9+ beam with fluences ranging from 3 1011 to 3 1013 ions/cm2. The atomic force microscopy images were subjected to power spectral density analysis and roughness analysis using an image analysis software. Clusters were found in the image of as-deposited samples, which indicates that the film growth is dominated by the island growth mode. As-deposited films were amorphous as evidenced from X-ray diffraction; however, high resolution transmission electron microscopy measurements revealed a short range atomic order in the samples with crystallites of size around 3 nm embedded in an amorphous matrix. X-ray diffraction pattern of the as-deposited films after irradiation does not show any appreciable changes, indicating that the passage of swift heavy ions stabilizes the short range atomic ordering, or even creates further amorphization. The crystallinity of the as-deposited Fe–Ni based films was improved by thermal annealing, and diffraction results indicated that ion beam irradiation on annealed samples results in grain fragmentation. On bombarding annealed films, the surface roughness of the films decreased initially, then, at higher fluences it increased. The observed change in surface morphology of the irradiated films is attributed to the interplay between ion induced sputtering, volume diffusion and surface diffusion

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have investigated the effects of swift heavy ion irradiation on thermally evaporated 44 nm thick, amorphous Co77Fe23 thin films on silicon substrates using 100 MeV Ag7+ ions fluences of 1 1011 ions/ cm2, 1 1012 ions/cm2, 1 1013 ions/cm2, and 3 1013 ions/cm2. The structural modifications upon swift heavy irradiation were investigated using glancing angle X-ray diffraction. The surface morphological evolution of thin film with irradiation was studied using Atomic Force Microscopy. Power spectral density analysis was used to correlate the roughness variation with structural modifications investigated using X-ray diffraction. Magnetic measurements were carried out using vibrating sample magnetometry and the observed variation in coercivity of the irradiated films is explained on the basis of stress relaxation. Magnetic force microscopy images are subjected to analysis using the scanning probe image processor software. These results are in agreement with the results obtained using vibrating sample magnetometry. The magnetic and structural properties are correlated