607 resultados para Personalized
Resumo:
We propose a new model of simultaneous price competition, based on firms offering personalized prices to consumers. In a market for a homogeneous good and decreasing returns, the unique equilibrium leads to a uniform price equal to the marginal cost of each firm, at their share of the market clearing quantity. Using this result for the short-run competition, we then investigate the long-run investment decisions of the firms. While there is underinvestment, the overall outcome is more competitive than the Cournot model competition. Moreover, as the number of firms grows we approach the competitive long-run outcome.
Resumo:
Background: Retrospective analyses suggest that personalized PK-based dosage might be useful for imatinib, as treatment response correlates with trough concentrations (Cmin) in cancer patients. Our objectives were to improve the interpretation of randomly measured concentrations and to confirm its efficiency before evaluating the clinical usefulness of systematic PK-based dosage in chronic myeloid leukemia patients. Methods and Results: A Bayesian method was validated for the prediction of individual Cmin on the basis of a single random observation, and was applied in a prospective multicenter randomized controlled clinical trial. 28 out of 56 patients were enrolled in the systematic dosage individualization arm and had 44 follow-up visits (their clinical follow-up is ongoing). PK-dose-adjustments were proposed in 39% having predicted Cmin significantly away from the target (1000 ng/ml). Recommendations were taken up by physicians in 57%, patients were considered non-compliant in 27%. Median Cmin at study inclusion was 754 ng/ml and differed significantly from the target (p=0.02, Wilcoxon test). On follow-up, Cmin was 984 ng/ml (p=0.82) in the compliant group. CV decreased from 46% to 27% (p=0.02, F-test). Conclusion: PK-based (Bayesian) dosage adjustment is able to bring individual drug exposure closer to a given therapeutic target. Its influence on therapeutic response remains to be evaluated.
Resumo:
Background and Aims: Recently, single nucleotide polymorphisms (SNPs) in IL28B were shown to correlate with response to pegylated interferon-a (IFN) and ribavirin therapy of chronic HCV infection. However, the cause for the SNPs effect on therapy response and its application for direct anti-viral (DAV) treatment are not clear. Here, we analyze early HCV kinetics as function of IL28B SNPs to determine its specific effect on viral dynamics. Methods: IL28B SNPs rs8099917, rs12979860 and rs12980275 were genotyped in 252 chronically HCV infected Caucasian naïve patients (67% HCV genotype 1, 28% genotype 2-3) receiving peginterferonalfa- 2a (180 mg/qw) plus ribavirin (1000-1200 mg/qd) in the DITTO study. HCV-RNA was measured (LD = 50 IU/ml) frequently during first 28 days. Results: RVR was achieved in 33% of genotype 1 patients with genotype CC at rs12979860 versus 12-16% for genotypes TT and CT (P < 0.03). Significant (P < 0.001) difference in viral decline was observed already at day 1 (see Figure). First phase decline was significantly (P < 0.001) larger in patients with genotype CC (2.0 log) than for TT and CT genotypes (0.6 and 0.8), indicating IFN anti-viral effectiveness in blocking virion production of 99% versus 75-84%. There was no significant association between second phase slope and rs12979860 genotype in patients with a first phase decline larger than 1 log. HCV kinetics as function of IL28b SNP. The same trend (not shown) was observed for HCV genotype 2-3 patients with different SNP genotype distribution that may indicate differential selection pressure as function of HCV genotype. Similar results were observed for SNPs rs8099917 and rs12980275, with a strong linkage disequilibrium among the 3 loci allowing to define the composite haplotype best associated with IFN effectiveness. Conclusions: IFN effectiveness in blocking virion production/ release is strongly affected by IL28B SNPs, but not other viral dynamic properties such as infected cell loss rate. Thus, IFN based therapy, as standard-of-care or in combination with DAV, should consider IL28B SNPs for prediction and personalized treatment, while response to pure DAV treatment may be less affected by IL28B SNPs. Additional analyses are undergoing to pinpoint the SNP effect on IFN anti-viral effectiveness.
Resumo:
Aside from ethical considerations, the primary requirement for usage of human tissues in basic or translational research is the thorough characterization of tissues. The second, but equally essential, requirement is that tissues be collected, processed, annotated, and preserved in optimal conditions. These requirements put the pathologist at the center of tissue banking activities and of research aimed at discovering new biomarkers. Pathologists not only provide information identifying the specimen but also make decisions on what materials should be biobanked, on the preservation conditions, and on the timeline of events that precede preservation and storage. This central position calls for increased recognition of the role of the pathologist by the biomolecular community and places new demands on the pathologist's workload and scope of scientific activities. These questions were addressed by an Expert Group Meeting of the European Biological and Biomolecular Research Infrastructure (BBMRI). While detailed recommendations are published elsewhere (Bevilacqua et al., Virchows Archivs, 2010, in press), this article outlines the strategic and technological issues identified by the Expert Group and identifies ways forward for better integration of pathology in the current thrust for development of biomarker-based "personalized medicine.
Resumo:
L’èxit del Projecte Genoma Humà (PGH) l’any 2000 va fer de la “medicina personalitzada” una realitat més propera. Els descobriments del PGH han simplificat les tècniques de seqüenciació de tal manera que actualment qualsevol persona pot aconseguir la seva seqüència d’ADN complerta. La tecnologia de Read Mapping destaca en aquest tipus de tècniques i es caracteritza per manegar una gran quantitat de dades. Hadoop, el framework d’Apache per aplicacions intensives de dades sota el paradigma Map Reduce, resulta un aliat perfecte per aquest tipus de tecnologia i ha sigut l’opció escollida per a realitzar aquest projecte. Durant tot el treball es realitza l’estudi, l’anàlisi i les experimentacions necessàries per aconseguir un Algorisme Genètic innovador que utilitzi tot el potencial de Hadoop.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
While mobile technologies can provide great personalized services for mobile users, they also threaten their privacy. Such personalization-privacy paradox are particularly salient for context aware technology based mobile applications where user's behaviors, movement and habits can be associated with a consumer's personal identity. In this thesis, I studied the privacy issues in the mobile context, particularly focus on an adaptive privacy management system design for context-aware mobile devices, and explore the role of personalization and control over user's personal data. This allowed me to make multiple contributions, both theoretical and practical. In the theoretical world, I propose and prototype an adaptive Single-Sign On solution that use user's context information to protect user's private information for smartphone. To validate this solution, I first proved that user's context is a unique user identifier and context awareness technology can increase user's perceived ease of use of the system and service provider's authentication security. I then followed a design science research paradigm and implemented this solution into a mobile application called "Privacy Manager". I evaluated the utility by several focus group interviews, and overall the proposed solution fulfilled the expected function and users expressed their intentions to use this application. To better understand the personalization-privacy paradox, I built on the theoretical foundations of privacy calculus and technology acceptance model to conceptualize the theory of users' mobile privacy management. I also examined the role of personalization and control ability on my model and how these two elements interact with privacy calculus and mobile technology model. In the practical realm, this thesis contributes to the understanding of the tradeoff between the benefit of personalized services and user's privacy concerns it may cause. By pointing out new opportunities to rethink how user's context information can protect private data, it also suggests new elements for privacy related business models.
Resumo:
Aquest treball vol mostrar que el debat de la raó il·lustrada, ja sigui des d'una posició de relativa defensa (com la que pren l'alemany Jürgen Habermas) o des d'una posició més crítica (personalitzada en aquest cas pel filòsof francès Michel Foucault), encara avui, al començament del segle XXI, determina plenament el debat sobre la racionalitat humana en general. El treball s'emmarca dins l'àmbit de la filosofia contemporània, més concretament dins la problemàtica filosòfica entorn de la raó que es va plantejar amb l'adveniment de la Modernitat, després amb l'anomenada Postmodernitat i actualment amb el corrent del Pensament Únic.
Resumo:
BACKGROUND AND PURPOSE: The study aims to assess the recanalization rate in acute ischemic stroke patients who received no revascularization therapy, intravenous thrombolysis, and endovascular treatment, respectively, and to identify best clinical and imaging predictors of recanalization in each treatment group. METHODS: Clinical and imaging data were collected in 103 patients with acute ischemic stroke caused by anterior circulation arterial occlusion. We recorded demographics and vascular risk factors. We reviewed the noncontrast head computed tomographies to assess for hyperdense middle cerebral artery and its computed tomography density. We reviewed the computed tomography angiograms and the raw images to determine the site and degree of arterial occlusion, collateral score, clot burden score, and the density of the clot. Recanalization status was assessed on recanalization imaging using Thrombolysis in Myocardial Ischemia. Multivariate logistic regressions were utilized to determine the best predictors of outcome in each treatment group. RESULTS: Among the 103 study patients, 43 (42%) received intravenous thrombolysis, 34 (33%) received endovascular thrombolysis, and 26 (25%) did not receive any revascularization therapy. In the patients with intravenous thrombolysis or no revascularization therapy, recanalization of the vessel was more likely with intravenous thrombolysis (P = 0·046) and when M1/A1 was occluded (P = 0·001). In this subgroup of patients, clot burden score, cervical degree of stenosis (North American Symptomatic Carotid Endarterectomy Trial), and hyperlipidemia status added information to the aforementioned likelihood of recanalization at the patient level (P < 0·001). In patients with endovascular thrombolysis, recanalization of the vessel was more likely in the case of a higher computed tomography angiogram clot density (P = 0·012), and in this subgroup of patients gender added information to the likelihood of recanalization at the patient level (P = 0·044). CONCLUSION: The overall likelihood of recanalization was the highest in the endovascular group, and higher for intravenous thrombolysis compared with no revascularization therapy. However, our statistical models of recanalization for each individual patient indicate significant variability between treatment options, suggesting the need to include this prediction in the personalized treatment selection.
Resumo:
Biomarker analysis is playing an essential role in cancer diagnosis, prognosis, and prediction. Quantitative assessment of immunohistochemical biomarker expression on tumor tissues is of clinical relevance when deciding targeted treatments for cancer patients. Here, we report a microfluidic tissue processor that permits accurate quantification of the expression of biomarkers on tissue sections, enabled by the ultra-rapid and uniform fluidic exchange of the device. An important clinical biomarker for invasive breast cancer is human epidermal growth factor receptor 2 [(HER2), also known as neu], a transmembrane tyrosine kinase that connotes adverse prognostic information for the patients concerned and serves as a target for personalized treatment using the humanized antibody trastuzumab. Unfortunately, when using state-of-the-art methods, the intensity of an immunohistochemical signal is not proportional to the extent of biomarker expression, causing ambiguous outcomes. Using our device, we performed tests on 76 invasive breast carcinoma cases expressing various levels of HER2. We eliminated more than 90% of the ambiguous results (n = 27), correctly assigning cases to the amplification status as assessed by in situ hybridization controls, whereas the concordance for HER2-negative (n = 31) and -positive (n = 18) cases was 100%. Our results demonstrate the clinical potential of microfluidics for accurate biomarker expression analysis. We anticipate our technique will be a diagnostic tool that will provide better and more reliable data, onto which future treatment regimes can be based.
Resumo:
Aquesta memòria recull les tasques realitzades per tal d'obtenir un CD que contingui una versió de LINUX personalitzada, amb la utilitat de poder ser utilitzada com a eina bàsica pels alumnes al llarg dels estudis cursats a la UOC. Es tracta d'un CD autoarrencable, cosa que vol dir que es pot executar directament des de qualsevol lector de CD, sense haver-se d'instal·lar permanentment en el disc dur dels PC.
Resumo:
El projecte Matic vol crear un entorn d'EAO apte per a treballar qualsevol contingut acadèmic i personalitzat per a cada estudiant, seguint les directrius marcades pel professor, que en podrà fer el seguiment acadèmic.
Resumo:
Les característiques imprescindibles per a qualsevol framework desenvolupat de forma personalitzada són: escalabilitat i multiplataforma, adaptabilitat a qualsevol sistema gestor de base de dades, vàlid per a qualsevol tipus de base de dades (relacional, en xarxa, jeràrquica, etc.) i fàcil maneig i simplicitat per a l'equip de desenvolupament. En el nostre WayPersistence v1.0 està validat per base de dades relacionals en un principi, millorable en versions posteriors.
Resumo:
El projecte genera un entorn personalitzat de gestió de factures electròniques utilitzant Visual Studio Tools, l¿entorn permet gestionar les bases de dades dels clients i dels productes oferts, generar factures i enviar-les via correu electrònic als clients en diferents formats (PDF o Word).
Resumo:
Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.