931 resultados para PI control scheme


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large-conductance Ca(2+)-activated K(+) channels (BK) play a fundamental role in modulating membrane potential in many cell types. The gating of BK channels and its modulation by Ca(2+) and voltage has been the subject of intensive research over almost three decades, yielding several of the most complicated kinetic mechanisms ever proposed. A large number of open and closed states disposed, respectively, in two planes, named tiers, characterize these mechanisms. Transitions between states in the same plane are cooperative and modulated by Ca(2+). Transitions across planes are highly concerted and voltage-dependent. Here we reexamine the validity of the two-tiered hypothesis by restricting attention to the modulation by Ca(2+). Large single channel data sets at five Ca(2+) concentrations were simultaneously analyzed from a Bayesian perspective by using hidden Markov models and Markov-chain Monte Carlo stochastic integration techniques. Our results support a dramatic reduction in model complexity, favoring a simple mechanism derived from the Monod-Wyman-Changeux allosteric model for homotetramers, able to explain the Ca(2+) modulation of the gating process. This model differs from the standard Monod-Wyman-Changeux scheme in that one distinguishes when two Ca(2+) ions are bound to adjacent or diagonal subunits of the tetramer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Active control solutions appear to be a feasible approach to cope with the steadily increasing requirements for noise reduction in the transportation industry. Active controllers tend to be designed with a target on the sound pressure level reduction. However, the perceived control efficiency for the occupants can be more accurately assessed if psychoacoustic metrics can be taken into account. Therefore, this paper aims to evaluate, numerically and experimentally, the effect of a feedback controller on the sound quality of a vehicle mockup excited with engine noise. The proposed simulation scheme is described and experimentally validated. The engine excitation is provided by a sound quality equivalent engine simulator, running on a real-time platform that delivers harmonic excitation in function of the driving condition. The controller performance is evaluated in terms of specific loudness and roughness. It is shown that the use of a quite simple control strategy, such as a velocity feedback, can result in satisfactory loudness reduction with slightly spread roughness, improving the overall perception of the engine sound. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power distribution automation and control are import-ant tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagentic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper compares the behaviour of two different control structures of automatic voltage regulators of synchronous machines equipped with static excitation systems. These systems have a fully controlled thyristor bridge that supplies DC current to the rotor winding. The rectifier bridge is fed by the stator terminals through a step-down transformer. The first control structure, named ""Direct Control"", has a single proportional-integral (PI) regulator that compares stator voltage setpoint with measured voltage and acts directly on the thyristor bridge`s firing angle. This control structure is usually employed in commercial excitation systems for hydrogenerators. The second structure, named ""Cascade Control"", was inspired on control loops of commercial DC motor drives. Such drives employ two PIs in a cascade arrangement, the external PI deals with the motor speed while the internal one regulates the armature current. In the adaptation proposed, the external PI compares setpoint with the actual stator voltage and produces the setpoint to the internal PI-loop which controls the field current.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim was to verify if the fungigation via drip irrigation is an alternative to the conventional method of spraying on tomato for controlling early blight. Tomato plants (variety Santa Clara) were grown in pots inside a greenhouse. Fifty days after transplanting, the plants were inoculated with Alternaria solani and treated with four different fungicides: azoxystrobin (8 g 100 L(-1)), difeconazole (50 mL 100 L(-1)), metiram+piraclostrobin (200 g 100 L(-1)) and tebuconazole (100 mL 100 L(-1)) using two applications methods: conventional spraying and fiingigation dripping. The control plants did not receive fungicide application. To assess the severity of the disease, we used a rating scale expressed as the area under the disease progress curve (AUDPC) and production factors, such as number, weight and average diameter of the fruit and its productivity. The experimental design was completely randomized in factorial scheme 4 x 2 + 1 with eight replicates. Each plot had one plant in one pot. A 27% reduction in disease severity was observed when compared with the control plants, with no significant difference noted regarding the application method. The number of fruits did not statistically differ between the treatments. The average weight and diameter of the fruits were superior in the plants that had fungicide application compared to the control plant, reflecting an increase in productivity. Fungigation through water dripping is an alternative to the conventional method of spraying cultured tomatoes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the role of arterial baroreceptors in arterial pressure (AP) and pulse interval (PI) regulation in conscious C57BL mice. Male animals, implanted with catheters in a femoral artery and a jugular vein, were submitted to sino-aortic (SAD), aortic (Ao-X) or carotid sinus denervation (Ca-X), 5 daysprior to the experiments. After basal recording of AP, the lack of reflex bradycardia elicited by administration of phenylephrine was used to confirm the efficacy of SAD, and cardiac autonomic blockade with methylatropine and propranolol was performed. The AP and PI variability were calculated in the time and frequency domains (spectral analysis/fast Fourier transform) with the spectra quantified in low-(LF; 0.25-1Hz) and high-frequency bands (HF; 1-5Hz). Basal AP and AP variability were higher after SAD, Ao-X or Ca-X than in intact mice. Pulse interval was similar among the groups, whereas PI variability was lower after SAD. Atropine elicited a slight tachycardia in control mice but did not change PI after total or partial denervation. The bradycardia caused by propranolol was higher after SAD, Ao-X or Ca-X compared with intact mice. The increase in the variability of AP was accompanied by a marked increase in the LF and HF power of the AP spectra after baroreceptor denervation. The LF and HF power of the PI were reduced by SAD and by Ao-X or Ca-X. Therefore, both sino-aortic and partial baroreceptor denervation in mice elicits hypertension and a remarkable increase in AP variability and cardiac sympathetic tonus. Spectral analysis showed an important contribution of the baroreflex in the power of LF oscillations of the PI spectra. Both sets of baroreceptors seem to be equally important in the autonomic regulation of the cardiovascular system in mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One hundred and twenty subjects with Chagas' cardiopathy and 120 non-infected subjects were randomly selected from first time claimants of sickness benefits in the National Institute of Social Security (INPS) in Goiás. Cases of Chagas' cardiopathy were defined based on serological test, history of residence in an endemic area and, clinical and/or electrocardiogram (ECG) alterations suggestive of Chagas' cardiomyopathy. Controls were defined as subjects with at least two negative serological tests. Case and controls were compared in the analysis for age, sex, place of birth, migration history, socio-economic level, occupation, physical exertion at work, age at affiliation and years of contribution to the social security scheme, clinical course of their disease and ECG abnormalities. Chagas' disease patients were younger than other subjects and predominantly of rural origin. Non-infected subjects presented a better socio-economic level, were performing more skilled activities and had less changes of job than cases. No important difference was observed in relation to age at affiliation to INPS. About 60% of cases have claimed for benefits within the first four years of contribution while among controls this proportion was 38.5%. Cases were involved, proportionally more than controls, in "heavy" activities. A risk of 2.3 (95%CL 1.5 - 4.6) and 1.8 (95%CL 1.2- 3.5) was obtained comparing respectively "heavy" and "moderate" physical activity against "light". A relative risk of 8.5 (95%CL 4.9 - 14.8) associated with the presence of cardiopathy was estimated comparing the initial sample of seropositive subjects and controls. A high relative risk was observed in relation to right bundle branch block (RR = 37.1 95%CL = 8.8 - 155.6) and left anterior hemiblock (RR = 4.4, 95%CL = 2.1 - 9.1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Analizar la dispersión de los ejemplares de una población de Tarebia granifera y su relación con la modificación de los parámetros morfométricos. METODOS: Se colectó por parcelas incluyendo dos tipos de substratos en condiciones opuestas de agregación y se comparó la abundancia relativa tanto entre muestreos, como entre sustratos. Se delimitaron 7 clases de alto a las cuales se les determinó el coeficiente peso/área del pié, el cual se correlacionó con la talla por clase. Se evaluó experimentalmente si los individuos con menor carga del pié tienen mayor persistencia en substratos emergidos, así como la interacción entre dos grupos de clases de alto. RESULTADOS: La diferencia de la abundancia entre los muestreos fue de t=5.874 (p<0.001) y de t=10.15 (p<0.001) entre el substrato rocoso emergido y el arenoso, sólo en condiciones de alta agregación, en las que la carga del pié de los individuos más grandes se reduce con la talla (r=-0.98, p<0.05). Experimentalmente, la abundancia de los ejemplares de tallas opuestas está mutuamente limitada (r=-0.87, p<0.01), la altura del oleaje limita la abundancia de los ejemplares menores (r=-0.94, p<0.001) siendo tolerada por los mayores (r=0.72, p<0.05). La carga promedio del pie disminuye con la altura del oleaje (r=-0.93, p<0.001). CONCLUSIONES: Con elevada agregación los ejemplares mayores emigran hacia substratos de difícil conquista por los menores, que están limitados por la acción mecánica del medio. La disminución de la carga del pie facilita la dispersión de los individuos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometers require controlled current sources in order to get accurate flux density with respect to its magnet. The main elements of the proposed solution are a power semiconductor, a DC voltage source and the magnet. The power semiconductor is commanded in order to get a linear control of the flux density. To implement the flux density control, a Hall Effect sensor is used. Furthermore, the dynamic behavior of the current source is analyzed and compared when using a PI controller and a PD2I controller.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a comparison between proportional integral control approaches for variable speed wind turbines. Integer and fractional-order controllers are designed using linearized wind turbine model whilst fuzzy controller also takes into account system nonlinearities. These controllers operate in the full load region and the main objective is to extract maximum power from the wind turbine while ensuring the performance and reliability required to be integrated into an electric grid. The main contribution focuses on the use of fractional-order proportional integral (FOPI) controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. A comparison between proposed control approaches for the variable speed wind turbines is presented using a wind turbine benchmark model in the Matlab/Simulink environment. Results show that FOPI has improved system performance when compared with classical PI and fuzzy PI controller outperforms the integer and fractional-order control due to its capability to deal with system nonlinearities and uncertainties. © 2014 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dragonflies show unique and superior flight performances than most of other insect species and birds. They are equipped with two pairs of independently controlled wings granting an unmatchable flying performance and robustness. In this paper, it is presented an adaptive scheme controlling a nonlinear model inspired in a dragonfly-like robot. It is proposed a hybrid adaptive (HA) law for adjusting the parameters analyzing the tracking error. At the current stage of the project it is considered essential the development of computational simulation models based in the dynamics to test whether strategies or algorithms of control, parts of the system (such as different wing configurations, tail) as well as the complete system. The performance analysis proves the superiority of the HA law over the direct adaptive (DA) method in terms of faster and improved tracking and parameter convergence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometers require controlled current sources in order to get accurate flux density with respect to its magnet. The main elements of the proposed solution are a power semiconductor, a DC voltage source and the magnet. The power semiconductor is commanded in order to get a linear control of the flux density. To implement the flux density control, a Hall Effect sensor is used. Furthermore, the dynamic behavior of the current source is analyzed and compared when using a PI controller and a PD2I controller.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.