951 resultados para PET CATS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of focal status epilepticus (SE) can be challenging, particularly when clinical manifestations leave doubts about its nature, and electroencephalography (EEG) is not conclusive. This work addresses the utility of ictal (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) in focal SE, which was performed in eight patients in whom SE was finally diagnosed. Clinical, MRI and EEG data were reviewed. (18)F-FDG-PET proved useful: (1) to establish the diagnosis of focal SE, when clinical elements were equivocal or the EEG did not show clear-cut epileptiform abnormalities; (2) to delineate the epileptogenic area in view of possible resective surgery; and (3) when clinical features, MRI and EEG were incongruent regarding the origin of SE. We suggest that ictal (18)F-FDG-PET may represent a valuable diagnostic tool in selected patients with focal SE or frequent focal seizures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: We asked whether myocardial flow reserve (MFR) by Rb-82 cardiac PET improve the selection of patients eligible for invasive coronary angiography (ICA). Material and Methods: We enrolled 26 consecutive patients with suspected or known coronary artery disease who performed dynamic Rb-82 PET/CT and (ICA) within 60 days; 4 patients who underwent revascularization or had any cardiovascular events between PET and ICA were excluded. Myocardial blood flow at rest (rMBF), at stress with adenosine (sMBF) and myocardial flow reserve (MFR=sMBF/rMBF) were estimated using the 1-compartment Lortie model (FlowQuant) for each coronary arteries territories. Stenosis severity was assessed using computer-based automated edge detection (QCA). MFR was divided in 3 groups: G1:MFR<1.5, G2:1.5≤MFR<2 and G3:2≤MFR. Stenosis severity was graded as non-significant (<50% or FFR ≥0.8), intermediate (50%≤stenosis<70%) and severe (≥70%). Correlation between MFR and percentage of stenosis were assessed using a non-parametric Spearman test. Results: In G1 (44 vessels), 17 vessels (39%) had a severe stenosis, 11 (25%) an intermediate one, and 16 (36%) no significant stenosis. In G2 (13 vessels), 2 (15%) vessels presented a severe stenosis, 7 (54%) an intermediate one, and 4 (31%) no significant stenosis. In G3 (9 vessels), 0 vessel presented a severe stenosis, 1 (11%) an intermediate one, and 8 (89%) no significant stenosis. Of note, among 11 patients with 3-vessel low MFR<1.5 (G1), 9/11 (82%) had at least one severe stenosis and 2/11 (18%) had at least one intermediate stenosis. There was a significant inverse correlation between stenosis severity and MFR among all 66 territories analyzed (rho= -0.38, p=0.002). Conclusion: Patients with MFR>2 could avoid ICA. Low MFR (G1, G2) on a vessel-based analysis seems to be a poor predictor of severe stenosis severity. Patients with 3-vessel low MFR would benefit from ICA as they are likely to present a significant stenosis in at least one vessel.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 37-year-old man suffering from insidious visual agnosia and spastic paraparesis due to a PSEN1 mutation. His mother was diagnosed with Alzheimer disease after a biopsy. He was assessed by multimodal neuroimaging, including new in vivo positron emission tomography amyloid imaging (F-AV45). His data were compared with those from healthy participants and patients with sporadic predemential Alzheimer disease. He exhibited posterior cortical thickness reduction, posterior hypometabolism, and increased amyloid ligand uptake in the posterior cortex and the striatum. We show that F-AV45 positron emission tomography allows visualization of the unusual pattern of amyloid deposits that co-localize with cortical atrophy in this genetic form of Alzheimer disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to evaluate the role of forced diuresis in improving the diagnostic accuracy of abdominopelvic (18)F-FDG PET. METHODS: Thirty-two patients were enrolled. Besides the presence of known intravesical tumors or undefined renal lesions on the initial PET scan, the inclusion criterion was the appearance of indeterminate or equivocal (18)F-FDG foci that extended along the course of the urinary tract and could not confidently be separated from urinary activity. For each patient, a second abdominopelvic PET study was performed after intravenous injection of 0.5 mg of furosemide per kilogram of body weight (maximum, 40 mg) coupled with parenteral infusion of physiologic saline. RESULTS: Forced diuresis coupled with parenteral hydration eliminated any significant (18)F-FDG activity from the lower urinary tract in 31 (97%) of 32 patients after the bladder had been voided 3 successive times. Twelve intravesical lesions were visualized with outstanding clarity, whereas radiologic suspicion of locally recurrent bladder tumors was ruled out in 3 patients. Among 14 indeterminate or equivocal extravesical foci, 7 were deemed of no clinical value because they disappeared after furosemide challenge, whereas 7 persisting foci were proven to be true-positive PET findings. The performance of (18)F-FDG PET in characterizing 3 renal-space-occupying lesions could not be improved by our protocol. CONCLUSION: Furosemide challenge has the potential to noninvasively resolve the inherent (18)F-FDG contrast handicap in the lower urinary tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we present a first feasibility study of the ClearPEM technology for simultaneous PET-MR imaging. The mutual electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing the response behavior of the ClearPEM detectors and front-end electronics to pulsed RF power and switched magnetic field gradients; and by analyzing the MR system performance degradation from noise pickup into the RF receiver chain, and from magnetic susceptibility artifacts caused by PET front-end materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron emission tomography with [18F] fluorodeoxyglucose (FDG-PET) plays a well-established role in assisting early detection of frontotemporal lobar degeneration (FTLD). Here, we examined the impact of intensity normalization to different reference areas on accuracy of FDG-PET to discriminate between patients with mild FTLD and healthy elderly subjects. FDG-PET was conducted at two centers using different acquisition protocols: 41 FTLD patients and 42 controls were studied at center 1, 11 FTLD patients and 13 controls were studied at center 2. All PET images were intensity normalized to the cerebellum, primary sensorimotor cortex (SMC), cerebral global mean (CGM), and a reference cluster with most preserved FDG uptake in the aforementioned patients group of center 1. Metabolic deficits in the patient group at center 1 appeared 1.5, 3.6, and 4.6 times greater in spatial extent, when tracer uptake was normalized to the reference cluster rather than to the cerebellum, SMC, and CGM, respectively. Logistic regression analyses based on normalized values from FTLD-typical regions showed that at center 1, cerebellar, SMC, CGM, and cluster normalizations differentiated patients from controls with accuracies of 86%, 76%, 75% and 90%, respectively. A similar order of effects was found at center 2. Cluster normalization leads to a significant increase of statistical power in detecting early FTLD-associated metabolic deficits. The established FTLD-specific cluster can be used to improve detection of FTLD on a single case basis at independent centers - a decisive step towards early diagnosis and prediction of FTLD syndromes enabling specific therapies in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is, aside skin cancer, the most common malignancy occurring after solid organ transplant in adults. Fluorodeoxyglucose (FDG) positron emission tomography (PET) has proved useful in the management of lymphomas. METHODS: We report our experience with the use of FDG-PET inline with computed tomography (CT) scanning in the management of four transplant recipients with histologically confirmed PTLD, including three monomorphic PTLDs and one polymorphic PTLD. RESULTS: FDG-PET/CT scan at diagnosis showed increased FDG uptake in all examined PTLD lesions, and the disease was upstaged on the basis of FDG-PET/CT scan results over conventional CT scanning in one patient. At the end of treatment, PET/CT scans no longer demonstrated FDG uptake in the original PTLD lesions in all patients. Complete remission of disease persisted for at least 1 year after diagnosis in all. CONCLUSIONS: Our results strongly support that FDG-PET scanning is highly specific for diagnosis and follow-up of PTLD. The clinical relevance of including FDG-PET/CT scanning in the management of PTLD should be evaluated in a larger prospective cohort study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MAP5, a microtubule-associated protein characteristic of differentiating neurons, was studied in the developing visual cortex and corpus callosum of the cat. In juvenile cortical tissue, during the first month after birth, MAP5 is present as a protein doublet of molecular weights of 320 and 300 kDa, defined as MAP5a and MAP5b, respectively. MAP5a is the phosphorylated form. MAP5a decreases two weeks after birth and is no longer detectable at the beginning of the second postnatal month; MAP5b also decreases after the second postnatal week but more slowly and it is still present in the adult. In the corpus callosum only MAP5a is present between birth and the end of the first postnatal month. Afterwards only MAP5b is present but decreases in concentration more than 3-fold towards adulthood. Our immunocytochemical studies show MAP5 in somata, dendrites and axonal processes of cortical neurons. In adult tissue it is very prominent in pyramidal cells of layer V. In the corpus callosum MAP5 is present in axons at all ages. There is strong evidence that MAP5a is located in axons while MAP5b seems restricted to somata and dendrites until P28, but is found in callosal axons from P39 onwards. Biochemical experiments indicate that the state of phosphorylation of MAP5 influences its association with structural components. After high speed centrifugation of early postnatal brain tissue, MAP5a remains with pellet fractions while most MAP5b is soluble. In conclusion, phosphorylation of MAP5 may regulate (1) its intracellular distribution within axons and dendrites, and (2) its ability to interact with other subcellular components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of bottled waters from a single natural spring distributed worldwide in polyethylene terephthalate (PET) bottles has been used to examine the effects of storage in plastic polymer material on the isotopic composition (delta(18)O and delta(2)H values) of the water. All samples analyzed were subjected to the same packaging procedure but experienced different conditions of temperature and humidity during storage. Water sorption and the diffusive transfer of water and water vapor through the wall of the PET bottle may cause isotopic exchange between water within the bottle and water vapor in air near the PET-water interface. Changes of about +4 parts per thousand for delta(2)H and +0.7 parts per thousand for delta(18)O have been measured for water after 253 days of storage within the PET bottle. The results of this study clearly indicate the need to use glass bottles for storing water samples for isotopic studies. It is imperative to transfer PET-bottled natural waters to glass bottles for their use as calibration material or potential international working standards. Copyright (C) 2008 John Wiley & Sons, Ltd.