997 resultados para Pós-secularismo
Resumo:
The generation of a spatially single-mode white-light supercontinuum has been observed in a photonic crystal fiber pumped with 60-ps pulses of subkilowatt peak power. The spectral broadening is identified as being due to the combined action of stimulated Raman scattering and parametric four-wave-mixing generation, with a negligible contribution from the self-phase modulation of the pump pulses. The experimental results are in good agreement with detailed numerical simulations. These findings demonstrate that ultrafast femtosecond pulses are not needed for efficient supercontinuum generation in photonic crystal fibers. © 2001 Optical Society of America.
Resumo:
info:eu-repo/semantics/published
Comparative selectivity and specificity of the proteasome inhibitors BzLLLCOCHO, PS-341, and MG-132.
Resumo:
It is shown that virtual H- formation has a profound effect upon low-energy Ps(1s)-H(1s) scattering, yet H- formation only accounts for about 10% of the total cross section just above threshold. Infinite series of Rydberg resonances converging on to the H- formation threshold are seen.
Resumo:
Summary Bortezomib (formerly PS-341) has significant activity in patients with relapsed multiple myeloma (MM), its efficacy is increased with the addition of dexamethasone and it demonstrates synergy with doxorubicin, thus providing the rationale for combination therapy with bortezomib, doxorubicin and dexamethasone (PAD). Patients with untreated MM received four 21-d cycles of PAD, comprising bortezomib 1·3 mg/m2 on days 1, 4, 8 and 11, along with dexamethasone 40 mg on days 1–4, 8–11 and 15–18 during cycle 1 and days 1–4 during cycles 2–4. During days 1–4, patients also received 0, 4·5 or 9 mg/m2 of doxorubicin at dose levels 1, 2, and 3 respectively. Following peripheral blood stem cell (PBSC) collection, patients received high-dose melphalan (MEL200) with PBSC transplantation (PBSCT). After PAD induction alone, 20 of 21 patients (95%) achieved at least a partial response (PR), including complete response (CR) in five patients (24%). Twenty of 21 had PBSC mobilized, and 18 of 20 received MEL200/PBSCT. In an intention-to-treat analysis, response rates were: CR 43%, near CR 14%, very good PR 24%, PR 14% and stable disease 5%. PAD was effective, did not prejudice subsequent PBSC collection, and should be further evaluated in prospective randomized trials.
Resumo:
The use of laser-accelerated protons as a particle probe for the detection of electric fields in plasmas has led in recent years to a wealth of novel information regarding the ultrafast plasma dynamics following high intensity laser-matter interactions. The high spatial quality and short duration of these beams have been essential to this purpose. We will discuss some of the most recent results obtained with this diagnostic at the Rutherford Appleton Laboratory (UK) and at LULI - Ecole Polytechnique (France), also applied to conditions of interest to conventional Inertial Confinement Fusion. In particular, the technique has been used to measure electric fields responsible for proton acceleration from solid targets irradiated with ps pulses, magnetic fields formed by ns pulse irradiation of solid targets, and electric fields associated with the ponderomotive channelling of ps laser pulses in under-dense plasmas.
Resumo:
This paper summarises die main results obtained during the two experimental campaigns on TCE X-ray lasers that we have carried out since the last Kyoto X-ray laser Conference in 1998. A two-color (2 omega /1 omega) pumping configuration was tested and led to the observation of a strong lasing line at 16 nm, identified to a 4f-4d transition in Ni-like Ag. A strong x 300-400 enhancement of the 13.9 nm Ni-like 4d-4p lasing emission was obtained when a traveling wave short pulse pumping was applied. Finally the temporal history of the 13.9 nm laser pulse was measured with a high-resolution Streak camera, A very short 2 ps X-ray laser pulse was directly demonstrated for the first time.
Resumo:
Objective
Preliminary assessment of an automated weaning system (SmartCare™/PS) compared to usual management of weaning from mechanical ventilation performed in the absence of formal protocols.
Design and setting
A randomised, controlled pilot study in one Australian intensive care unit.
Patients
A total of 102 patients were equally divided between SmartCare/PS and Control.
Interventions
The automated system titrated pressure support, conducted a spontaneous breathing trial and provided notification of success (“separation potential”).
Measurements and results
The median time from the first identified point of suitability for weaning commencement to the state of “separation potential” using SmartCare/PS was 20 h (interquartile range, IQR, 2–40) compared to 8 h (IQR 2–43) with Control (log-rank P = 0.3). The median time to successful extubation was 43 h (IQR 6–169) using SmartCare/PS and 40 (14–87) with Control (log-rank P = 0.6). Unadjusted, the estimated probability of reaching “separation potential” was 21% lower (95% CI, 48% lower to 20% greater) with SmartCare/PS compared to Control. Adjusted for other covariates (age, gender, APACHE II, SOFAmax, neuromuscular blockade, corticosteroids, coma and elevated blood glucose), these estimates were 31% lower (95% CI, 56% lower to 9% greater) with SmartCare/PS. The study groups showed comparable rates of reintubation, non-invasive ventilation post-extubation, tracheostomy, sedation, neuromuscular blockade and use of corticosteroids.
Conclusions
Substantial reductions in weaning duration previously demonstrated were not confirmed when the SmartCare/PS system was compared to weaning managed by experienced critical care specialty nurses, using a 1:1 nurse-to-patient ratio. The effect of SmartCare/PS may be influenced by the local clinical organisational context.
Resumo:
Evidence of high gain pumped by recombination has been observed in the 5g-4f transition at 11.1 nn in sodiumlike copper ions with use of a 20-J 2-ps Nd:glass laser system. The time- and space-integrated gain coefficient was 8.8 +/- 1.4 cm(-1), indicating a single-transit amplification of similar to 60 times. This experiment has shown that 2 ps is the optimum pulse duration to drive the sodiumlike copper recombination x-ray lasing at 11.1 nm. (C) 1996 Optical Society of America