980 resultados para Nuclear science
Resumo:
Luminescent films containing terbium complex [Tb(acac)(3)(H(2)O)(3)] (acac = acetylacetonate) doped into a polycarbonate (PC) matrix were prepared and irradiated at low-dose gamma radiation with ratio of 5 and 10 kGy. The PC polymer was doped with 5% (w/w) of the Tb(3+) complex. The thermal behavior was investigated by utilization of differential scanning calorimetry (DSC) and thermogravimetry analysis (TGA). Changes in thermal stability due to the addition of doping agent into the polycarbonate matrix. Based on the emission spectra of PC:5% Tb(acac)(3) film were observed the characteristic bands arising from the (5)D(4) -> (7)F(J) transitions of Tb(3+) ion (J = 0-6), indicating the ability to obtain the luminescent films. Doped samples irradiated at low dose of gamma irradiation showed a decrease in luminescence intensity with increasing of the dose. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Instrumental neutron activation analysis (INAA) was applied to assess trace element concentrations in six samples of aspirin tablets acquired in SA o pound Paulo city, Brazil. Concentrations of the elements Br, Ca, Co, Cr, Fe, K, La, Na, Sc and Zn were determined. Comparisons were made between the results obtained with published data for aspirins from foreign countries. Certified reference materials, INCT-MPH-2 Mixed Polish Herbs were analyzed for quality control of the analytical results.
Resumo:
Alachlor has been widely used in agriculture all over the world. It is suggested that it may be a carcinogen and an environmental estrogen. The aim of this work was to verify the degradation the alachlor by gamma radiation. Gamma radiation from (60)Co was used to degrade the alachlor herbicide in water and methanol solution. The alachlor in water and alcohol solution in the concentration of 100 mgL(-1) was irradiated with doses of 0.25-50 kGy, at dose rate 5-6 and 2.7 kGyh(-1). High performance liquid chromatography was used as an analytical technique to determine the degradation rate of herbicide studied.
Resumo:
In this work, GdAlO3:Pr3+ was successfully prepared by the Pechini method at lower temperatures when compared to others methods such as solid-state synthesis and sol-gel process. In accordance to the XRD data, the fully crystalline single-phase GdAlO3 could be obtained at 900 degrees C. Luminescence measurements indicate Gd -> Pr3+ energy transfer. In the emission spectra, the P-3(0) ->(3) H-4 (blue emission) and D-1(2) ->(3) H-4 (red emission) transitions of Pr3+ ions can be observed and the ratio between their intensities depends on the Pr3+ content due to the cross-relaxation phenomenon.
Resumo:
We report on operational experience with an experimental performance of the SLD barrel Cherenkov Ring Imaging Detector from the 1992 and 1993 physics runs. The liquid (C6F14) and gas (C5F12) radiator recirculation systems have performed well, and the drift gas supply system has operated successfully with TMAE for three years. Cherenkov rings have been observed from both the liquid and gas radiators. The number and angular resolution of Cherenkov photons have been measured, and found to be close to design specifications.
Resumo:
The SLD Barrel Cherenkov Ring Imaging Detector was fully operational in the 1992 physics data run. The electron drift velocity and magnetic field deflection of electron trajectories have been measured. Cherenkov rings have been observed from both the liquid and gas radiators. The number and the resolution of the angle of Cherenkov photons have been measured to be approximately equal to design specifications.
Resumo:
We describe the design and operation of the fluid delivery, monitor and control systems for the SLD barrel Cherenkov Ring Imaging Detector (CRID). The systems deliver drift gas (C2H6+TMAE), radiator gas (C5F12+N2) and radiator liquid (C6F14). MeasUred critical quantities such as electron lifetime in the drift gas and ultra-violet (UV) transparencies of the radiator fluids, together with the operational experience, are also reported.
Resumo:
The GEANT4 simulations are essential for the development of medical tomography with proton beams pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with the results of other popular Monte Carlo codes like TRIM/SRIM, or MCNPX. For thick absorbers, however, the disagreements became evident. In a part, these disagreements are due to the known contradictions in the NIST PSTAR and SRIM reference data. Therefore, it is interesting to compare the GEANT4 results with each other, with experiment, and with diverse code results in a reduced form, which is free from this kind of doubts. In this work such comparison is done within the Reduced Calibration Curve concept elaborated for the proton beam tomography. © 2010 IEEE.
Resumo:
The present work is focused on the study of a seasonal anthropogenic influence on the beach of Itamambuca (Ubatuba, SP, Brazil) carried out using Atherinella brasiliensis as biomonitor. In total 84 fish were caught between July 2004 and February 2005 in different locations at the beach and inside the Itamambuca river. The fish were pooled according to catch and their musculature was analyzed by Particle-Induced X-ray Emission (PIXE) and Rutherford Backscattering (RBS) techniques. While the concentration of light (matrix) elements like C and O were obtained using the RBS technique, major (Na, Mg, P, S, Cl, K and Ca) and trace (Si, Al, Ti, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Br and Sr) elements were measured by PIXE. The results show that differences were observed for several elemental concentrations of fish tissue between high season (spring-summer) and low season (winter-fall), indicating that increased human activity in the beach during high season may have some impact on the beach ecosystem. The role of the water salinity in the results is also discussed. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Twenty six bottom sediment samples were collected from the Cananeia estuary in summer and winter of 2005. Multielemental analysis was carried out by instrumental neutron activation analysis. Total mercury was determined by cold vapor atomic absorption. As, Cr, Hg and Zn concentrations were compared to the Canadian oriented values (TEL and PEL). Sample points 4 and 9 presented higher concentration for most elements and As and Cr exceeded the TEL values. Organic matter (>10%) associated with siltic and clay sediments was observed. Climatic conditions, hydrodynamic and biogeochemical processes promote differences in seasonal concentrations of elements at some points, which contribute to special distributions.
Resumo:
The KASCADE-Grande experiment, located at Karlsruhe Institute of Technology (Germany) is a multi-component extensive air-shower experiment devoted to the study of cosmic rays and their interactions at primary energies 10(14)-10(18) eV. Main goals of the experiment are the measurement of the all-particle energy spectrum and mass composition in the 10(16)-10(18) eV range by sampling charged (N-ch) and muon (N-mu) components of the air shower. The method to derive the energy spectrum and its uncertainties, as well as the implications of the obtained result, is discussed. An overview of the analyses performed by KASCADE-Grande to derive the mass composition of the measured high-energy comic rays is presented as well. (C) 2012 Elsevier By. All rights reserved.
Resumo:
So Paulo is the largest city in Brazil and South America with about 20 million inhabitants in the metropolitan area, more than nine million motor vehicles and intense industrial activity, which are responsible for increasing pollution in the region. Nevertheless, little is known concerning metal and semi-metal content in the soils of this metropolitan region. This type of information could be extremely useful as a fingerprint of environmental pollution. The present study determined the elements As, Ba, Co, Cr, Sb, and Zn concentrations in soils adjacent to avenues of highly dense traffic in So Paulo city to assess their levels and possible sources. The analytical technique employed was Instrumental neutron activation analysis. The results showed, except for Co, concentration levels higher than the reference values for soils of So Paulo, according to the Environmental Protection Agency of the State of So Paulo guidelines. When compared to similar studies in other cities around the world, So Paulo soils presented higher levels, probably due to its high density traffic and industrial activity. The concentrations obtained for As and Cr indicate anthropogenic origin. The high levels of the traffic-related elements Ba, Sb, and Zn in soils nearby high density traffic avenues indicate they may originate from vehicular exhausts.
Resumo:
Each plasma physics laboratory has a proprietary scheme to control and data acquisition system. Usually, it is different from one laboratory to another. It means that each laboratory has its own way to control the experiment and retrieving data from the database. Fusion research relies to a great extent on international collaboration and this private system makes it difficult to follow the work remotely. The TCABR data analysis and acquisition system has been upgraded to support a joint research programme using remote participation technologies. The choice of MDSplus (Model Driven System plus) is proved by the fact that it is widely utilized, and the scientists from different institutions may use the same system in different experiments in different tokamaks without the need to know how each system treats its acquisition system and data analysis. Another important point is the fact that the MDSplus has a library system that allows communication between different types of language (JAVA, Fortran, C, C++, Python) and programs such as MATLAB, IDL, OCTAVE. In the case of tokamak TCABR interfaces (object of this paper) between the system already in use and MDSplus were developed, instead of using the MDSplus at all stages, from the control, and data acquisition to the data analysis. This was done in the way to preserve a complex system already in operation and otherwise it would take a long time to migrate. This implementation also allows add new components using the MDSplus fully at all stages. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
The photons scattered by the Compton effect can be used to characterize the physical properties of a given sample due to the influence that the electron density exerts on the number of scattered photons. However, scattering measurements involve experimental and physical factors that must be carefully analyzed to predict uncertainty in the detection of Compton photons. This paper presents a method for the optimization of the geometrical parameters of an experimental arrangement for Compton scattering analysis, based on its relations with the energy and incident flux of the X-ray photons. In addition, the tool enables the statistical analysis of the information displayed and includes the coefficient of variation (CV) measurement for a comparative evaluation of the physical parameters of the model established for the simulation. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a mono-chromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. (C) 2012 Elsevier Ltd. All rights reserved.