999 resultados para Myocardial Doppler Velocity (mdv)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study aimed to evaluate the characteristics of the brain and vascular indicesof the middle cerebral artery of canine foetuses. Methods: Twenty-five bitches were selected. Tissue development, echogenicity, echotexture and brain echobiometric data were studied, and the major structures were identified between the 5th and 8th gestational weeks. The area and volume of the brain mass (BMA and BMV), cranial area and volume (AC and VC), brain mass index (BMI) and brain volume index (BVI) were determined. A single ultrasound examination was performed during each studied week (6th, 7th and 8th). Doppler ultrasonography was performed to assess the maximum and minimum velocity, resistance and pulsatility index of middle cerebral artery of the foetuses. Results: Echoencephalography was performed to evaluate the morphological characteristics of the central nervous system. Cerebral echobiometry indicated an increase in area and volume of the hemispheres and cranium (P<0·001) but no changes in BMI or BVI over the gestational period studied. Doppler ultrasonography identified increases in peak systolic velocity (P=0·0188) and end diastolic velocity (P=0·0274) and decreases in resistance index (P=0·0002) and pulsatility index (P<0·001). Clinical Significance: Echoencephalography and spectral Doppler ultrasonography of the middle cerebral artery in canine foetuses might be a useful technique for prenatal care. © 2013 British Small Animal Veterinary Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: After acute myocardial infarction, during the cardiac repair phase, periostin is released into the infarct and activates signaling pathways that are essential for the reparative process. However, the role of periostin in chronic cardiac remodeling after myocardial infarction remains to be elucidated. Therefore, the objective of this study was to investigate the relationship between tissue periostin and cardiac variables in the chronic cardiac remodeling induced by myocardial infarction. METHODS: Male Wistar rats were assigned to 2 groups: a simulated surgery group (SHAM; n = 8) and a myocardial infarction group (myocardial infarction; n = 13). After 3 months, morphological, functional and biochemical analyses were performed. The data are expressed as means±SD or medians (including the lower and upper quartiles). RESULTS: Myocardial infarctions induced increased left ventricular diastolic and systolic areas associated with a decreased fractional area change and a posterior wall shortening velocity. With regard to the extracellular matrix variables, the myocardial infarction group presented with higher values of periostin and types I and III collagen and higher interstitial collagen volume fractions and myocardial hydroxyproline concentrations. In addition, periostin was positively correlated with type III collagen levels (r = 0.673, p = 0.029) and diastolic (r = 0.678, p = 0.036) and systolic (r = 0.795, p = 0.006) left ventricular areas. Considering the relationship between periostin and the cardiac function variables, periostin was inversely correlated with both the fractional area change (r = -0.783, p = 0.008) and the posterior wall shortening velocity (r = -0.767, p = 0.012). CONCLUSIONS: Periostin might be a modulator of deleterious cardiac remodeling in the chronic phase after myocardial infarction in rats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar, por meio da ultrassonografia convencional modo B, as características sonográficas e a biometria dos rins de fetos caninos, bem como determinar os índices vasculares da artéria renal dos conceptos ao Doppler Triplex. Foram utilizadas 24 fêmeas Shi-tzu e Pugs pesando de quatro a 10 kg e com idade entre quatro e seis anos. Ao modo B, a ecobiometria renal fetal, a regularidade da superfície renal, a ecotextura e a relação córtico-medular foram avaliadas durante a quinta, sexta, sétima e oitava semanas gestacionais. Ao Doppler Triplex, durante o mesmo período em que se realizou o exame convencional, foram determinados o pico de velocidade sistólica (PVS), a velocidade diastólica final (EDV) e o índice de resistência vascular (RI) e de pulsatividade (PI). Ao modo B, não foram detectadas alterações em rins fetais, e à ecobiometria renal dos fetos, foi possível determinar medidas renais importantes, verificando-se aumento das biometrias no decorrer do desenvolvimento fetal (P<0,0001). Ao Doppler Triplex, determinaram-se os índices vasculares da artéria renal fetal, sendo que os valores para PSV e EDV aumentaram no decorrer das semanas gestacionais (P<0,05) e permaneceram constantes para PI e RI (P>0,05). Concluiu-se que o modo B e o Doppler Triplex são ferramentas importantes para a avaliação do desenvolvimento renal fetal, com a utilização da ecobiometria renal e avaliação dos indices vasculares da artéria renal de fetos caninos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contents This study aimed to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery in healthy and undergoing subclinical and clinical mastitis goats. Thirty animals among Saanen and Alpine Brown goats were arranged in three groups, healthy goats (HG), goats with subclinical mastitis (SMG) and goats with clinical mastitis (CMG). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hyperechogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on HG and SMG and heterogeneity for animals on CMG. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry did not reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of end diastolic velocity and raise of pulsatility index between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of dairy goats with mastitis. It is a sensitive and specific method for the study of this disease. Doppler mode was unable to establish reliable criteria for diagnosis of subclinical mastitis. Moreover, the quantification of echogenicity is a useful technique for the evaluation of the milk in animals with mastitis; therefore, it is suggested that it can be used as complementary technique for the diagnosis of mastitis in goats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)