875 resultados para Motion Correction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluated the efficacy of the Old Way/New Way methodology (Lyndon, 1989/2000) with regard to the permanent correction of a consolidated and automated technical error experienced by a tennis athlete (who is 18 years old and has been engaged in practice mode for about 6 years) in the execution of serves. Additionally, the study assessed the impact of intervention on the athlete’s psychological skills. An individualized intervention was designed using strategies that aimed to produce a) a detailed analysis of the error using video images; b) an increased kinaesthetic awareness; c) a reactivation of memory error; d) the discrimination and generalization of the correct motor action. The athlete’s psychological skills were measured with a Portuguese version of the Psychological Skills Inventory for Sports (Cruz & Viana, 1993). After the intervention, the technical error was corrected with great efficacy and an increase in the athlete’s psychological skills was verified. This study demonstrates the methodology’s efficacy, which is consistent with the effects of this type of intervention in different contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Series title: Springerbriefs in applied sciences and technology, ISSN 2191-530X"

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Series title: Springerbriefs in applied sciences and technology, ISSN 2191-530X"

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the case of a 40-day-old female patient with a history of breathlessness since birth who was referred to our hospital for surgical correction of common arterial trunk. The invasive investigation disclosed a Fallot¢s tetralogy anatomy associated with an anomalous origin of the left pulmonary artery from the ascending aorta. Immediately after diagnosis, the patient underwent a successful total surgical correction of the defect, including simultaneous anastomosis of the left pulmonary artery to the pulmonary trunk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate whether left ventricular end-systolic (ESD) diameters £ 51mm in patients (pt) with severe chronic mitral regurgitation (MR) are predictors of a poor prognosis after mitral valve surgery (MVS). METHODS: Eleven pt (aged 36±13 years) were studied in the preoperative period (pre), median of 36 days; in the early postoperative period (post1), median of 9 days; and in the late postoperative period (post2), mean of 38.5±37.6 months. Clinical and echocardiographic data were gathered from each pt with MR and systolic diameter ³51mm (mean = 57±4mm) to evaluate the result of MVS. Ten patients were in NYHA Class III/IV. RESULTS: All but 2 pt improved in functional class. Two pt died from heart failure and infectious endocarditis 14 and 11 months, respectively, after valve replacement. According to ejection fraction (EF) in post2, we identified 2 groups: group 1 (n=6), whose EF decreased in post1, but increased in post2 (p=0.01) and group 2 (n=5), whose EF decreased progressively from post1 to post2 (p=0.10). All pt with symptoms lasting £ 48 months had improvement in EF in post2 (p=0.01). CONCLUSION: ESD ³51mm are not always associated with a poor prognosis after MVS in patients with MR. Symptoms lasting up to 48 months are associated with improvement in left ventricular function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of aneurysmal dilation of the aortic residual segment, involving abdominal vessels in corrective surgeries for thoracoabdominal aortic aneurysm, through the identification of risk groups for recurrent dilation, aiming at using a specific operative technique with a branched graft, to prevent aneurysm relapse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.