947 resultados para Microfluidic Devices
Resumo:
Voltage unbalance is a major power quality problem in low voltage residential feeders due to the random location and rating of single-phase rooftop photovoltaic cells (PV). In this paper, two different improvement methods based on the application of series (DVR) and parallel (DSTATCOM) custom power devices are investigated to improve the voltage unbalance problem in these feeders. First, based on the load flow analysis carried out in MATLAB, the effectiveness of these two custom power devices is studied vis-à-vis the voltage unbalance reduction in urban and semi-urban/rural feeders containing rooftop PVs. Their effectiveness is studied from the installation location and rating points of view. Later, a Monte Carlo based stochastic analysis is carried out to investigate their efficacy for different uncertainties of load and PV rating and location in the network. After the numerical analyses, a converter topology and control algorithm is proposed for the DSTATCOM and DVR for balancing the network voltage at their point of common coupling. A state feedback control, based on pole-shift technique, is developed to regulate the voltage in the output of the DSTATCOM and DVR converters such that the voltage balancing is achieved in the network. The dynamic feasibility of voltage unbalance and profile improvement in LV feeders, by the proposed structure and control algorithm for the DSTATCOM and DVR, is verified through detailed PSCAD/EMTDC simulations.
Resumo:
Despite the predictions, the true potential of Nb2O5 for electrochromic applications has yet to be fully realized. In this work, three-dimensional (3D) compact and well-ordered nanoporous Nb2O5 films are synthesized by the electrochemical anodization of niobium thin films. These films are formed using RF sputtering and then anodized in an electrolyte containing ethylene glycol, ammonium fluoride, and small water content (4%) at 50 °C which resulted in low embedded impurities within the structure. Characterization of the anodized films shows that a highly crystalline orthorhombic phase of Nb2O5 is obtained after annealing at 450 °C. The 3D structure provides a template consisting of a large concentration of active sites for ion intercalation, while also ensuring low scattering directional paths for electrons. These features enhance the coloration efficiency to 47.0 cm2 C?1 (at 550 nm) for a 500 nm thick film upon Li+ ion intercalation. Additionally, the Nb2O5 electrochromic device shows a high bleached state transparency and large optical modulation.
Resumo:
We introduce the idea of geo-locking through a mobile phone based photo sharing application called Picalilly (figure 1). Using its geo-locking feature, Picalilly allows its users to manually define geographical boundaries for sharing photos -- limiting sharing within user-defined boundaries as well as facilitating open sharing between strangers within such boundaries. To explore the potential of geo-locking, we carried out a small scale field trial of Picalilly involving two groups of students, who were part of a two-week long introduction program at a university. Our preliminary results show that Picalilly facilitated 1) sharing of 'places' and 2) localized explorations.
Resumo:
The conflicts in Iraq and Afghanistan have been epitomized by the insurgents’ use of the improvised explosive device against vehicle-borne security forces. These weapons, capable of causing multiple severely injured casualties in a single incident, pose the most prevalent single threat to Coalition troops operating in the region. Improvements in personal protection and medical care have resulted in increasing numbers of casualties surviving with complex lower limb injuries, often leading to long-term disability. Thus, there exists an urgent requirement to investigate and mitigate against the mechanism of extremity injury caused by these devices. This will necessitate an ontological approach, linking molecular, cellular and tissue interaction to physiological dysfunction. This can only be achieved via a collaborative approach between clinicians, natural scientists and engineers, combining physical and numerical modelling tools with clinical data from the battlefield. In this article, we compile existing knowledge on the effects of explosions on skeletal injury, review and critique relevant experimental and computational research related to lower limb injury and damage and propose research foci required to drive the development of future mitigation technologies.
Resumo:
Lower extremities are particularly susceptible to injury in an under‐vehicle explosion. Operational fitness of military vehicles is assessed through anthropometric test devices (ATDs) in full‐scale blast tests. The aim of this study was to compare the response between the Hybrid‐III ATD, the MiL‐Lx ATD and cadavers in our traumatic injury simulator, which is able to replicate the response of the vehicle floor in an under‐vehicle explosion. All specimens were fitted with a combat boot and tested on our traumatic injury simulator in a seated position. The load recorded in the ATDs was above the tolerance levels recommended by NATO in all tests; no injuries were observed in any of the 3 cadaveric specimens. The Hybrid‐III produced higher peak forces than the MiL‐Lx. The time to peak strain in the calcaneus of the cadavers was similar to the time to peak force in the ATDs. Maximum compression of the sole of the combat boot was similar for cadavers and MiL‐Lx, but significantly greater for the Hybrid‐III. These results suggest that the MiL‐Lx has a more biofidelic response to under‐vehicle explosive events compared to the Hybrid‐III. Therefore, it is recommended that mitigation strategies are assessed using the MiL‐Lx surrogate and not the Hybrid‐III.
Resumo:
Oral endotracheal tubes (ETTs) and nasogastric tubes (NGT) are common devices used in adult intensive care and numerous options exist for safe and comfortable securement of these devices. The aim of this project was to identify the available range of ETT and NGT securement devices in Australia as a resource for clinicians seeking to explore options for tube stabilisation. This article reports part A of this project: ETT securement options. Part B will report NGT device fixation options. Securing ETTs to ensure a patent airway with minimal ETT movement, promotion of patient comfort and absence of adverse events such as ETT dislodgement, unplanned extubation and device-related injury1, are essential critical care nursing actions. The ETT requires a fixation method that is robust yet does not traumatise or injure the mucosal tissues of the mouth and soft tissue of the lips.2,3 Choice of a securement apparatus is often determined by product availability in our units or hospitals but is also driven by evidence-based practice and clinician preference. Trying to put this information together can be difficult and time-consuming for the bedside clinician...
Resumo:
This article is the second part of a two-part series examining securement options for commonly used therapeutic devices in the adult intensive care unit. Part A focused on endotracheal device securement.1 This article addresses nasogastric tube (NGT) securement options and with the aim of identifying the available range of NGT securement devices in Australia as a resource for clinicians seeking to explore options for tube stabilisation. Nasogastric feeding or gastric decompression tubes are commonly inserted via the nostril/nares. The National Pressure Ulcer Advisory Panel (NPUAP) 2011 position statement on mucosal pressure injuries, highlighted that mucosal tissues are vulnerable to pressure from devices.2 Securing of these devices sometimes leads to pressure-related injury to the internal mucosa due to difficulty visualising the mucosa and failure to reposition the nasogastric tube to relieve the pressure in a particular area.3 The nasal orifice is much smaller than the oral cavity and regular tube position changes are vital to minimise the risk of mucosal damage and ulcer development.
Resumo:
There is a continuous quest for developing electrochromic (EC)transition metal oxides (TMOs) with increased coloration efficiency. As emerging TMOs, Nb2O5 films, even those of ordered anodized nanochannels, have failed to produce the required EC performance for practical applications. This is attributed to limitations presented by its relatively wide bandgap and low capacity for accommodating ions. To overcome such issues, MoO3 was electrodeposited onto Nb2O5 nanochannelled films as homogeneously conformal and stratified α-MoO3 coatings of different thickness. The EC performance of the resultant MoO3 coated Nb2O5 binary system was evaluated. The system exhibited a coloration efficiency of 149.0 cm2 C−1, exceeding that of any previous reports on MoO3 and Nb2O5 individually or their compounds. The enhancement was ascribed to a combination of the reduced effective bandgap of the binary system, the increased intercalation probability from the layered α-MoO3 coating, and a high surface-tovolume ratio, while the Nb2O5 nanochannelled templates provided stability and low impurity pathways for charge transfer to occur.
Resumo:
This thesis is a comparative investigation of the methodology applied to human skin temperature measurement. The findings of this thesis suggest that clinical and significant differences exist between conductive and infrared devices which are commonly employed in the assessment of human skin temperature. These significant differences could potentially influence the interpretation of results, diagnosis and therefore treatment outcomes for health, clinical and exercise science applications.
Resumo:
To provide card holder authentication while they are conducting an electronic transaction using mobile devices, VISA and MasterCard independently proposed two electronic payment protocols: Visa 3D Secure and MasterCard Secure Code. The protocols use pre-registered passwords to provide card holder authentication and Secure Socket Layer/ Transport Layer Security (SSL/TLS) for data confidentiality over wired networks and Wireless Transport Layer Security (WTLS) between a wireless device and a Wireless Application Protocol (WAP) gateway. The paper presents our analysis of security properties in the proposed protocols using formal method tools: Casper and FDR2. We also highlight issues concerning payment security in the proposed protocols.
Resumo:
An atmospheric microplasma jet produces three-dimensional (3D) microfluidic channels on dense arrays of vertically aligned carbon nanotubes, which confines Au nanodot aqueous solution. The resulting hybrid 3D nanostructure is exploited as an effective microscopic area-selective sensing platform based on surface-enhanced Raman scattering.
Resumo:
Effective control of morphology and electrical connectivity of networks of single-walled carbon nanotubes (SWCNTs) by using rough, nanoporous silica supports of Fe catalyst nanoparticles in catalytic chemical vapor deposition is demonstrated experimentally. The very high quality of the nanotubes is evidenced by the G-to-D Raman peak ratios (>50) within the range of the highest known ratios. Transitions from separated nanotubes on smooth SiO2 surface to densely interconnected networks on the nanoporous SiO2 are accompanied by an almost two-order of magnitude increase of the nanotube density. These transitions herald the hardly detectable onset of the nanoscale connectivity and are confirmed by the microanalysis and electrical measurements. The achieved effective nanotube interconnection leads to the dramatic, almost three-orders of magnitude decrease of the SWCNT network resistivity compared to networks of similar density produced by wet chemistry-based assembly of preformed nanotubes. The growth model, supported by multiscale, multiphase modeling of SWCNT nucleation reveals multiple constructive roles of the porous catalyst support in facilitating the catalyst saturation and SWCNT nucleation, consistent with the observed higher density of longer nanotubes. The associated mechanisms are related to the unique surface conditions (roughness, wettability, and reduced catalyst coalescence) on the porous SiO2 and the increased carbon supply through the supporting porous structure. This approach is promising for the direct integration of SWCNT networks into Si-based nanodevice platforms and multiple applications ranging from nanoelectronics and energy conversion to bio- and environmental sensing.
Resumo:
This thesis has developed a new approach to trace virtual protection signals in Electrical substation networks. The main goal of the research was to analyse the contents of the virtual signals transferred, using third party software. In doing so, a comprehensive test was done on a distance protection relay, using non-conventional test equipment.
Resumo:
The use of Portable Medical Devices (PMDs) has become increasingly widespread over the last few years. A combination of factors; including advances in technology, the pressure to reduce public health costs and the desire to make health solutions accessible to a wider patient base are contributing to the growth in the PMD market. Design has a clear role to play in the current and future context of the PMD landscape. In this paper, we identify emerging trends in the design of PMDs; including changes in the form, purpose and mode of use, and explore how these trends are likely to fundamentally impact the nature of healthcare and the patient experience from an experience design perspective. We conclude by identifying a research opportunity for design within the healthcare and PMD context.
Resumo:
Background: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Methods: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. Results: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/ 226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). Conclusions: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.