960 resultados para Metal-Ceramic interface. Tricone drill bits. Brazing. Wetting. Contact angle
Resumo:
Purpose: The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. Materials and Methods: Computer-aided design software was used to create 32 finite element models of an atrophic posterior partially edentulous mandible with a single external-hexagon implant (5 mm wide × 7 mm long) in the first molar region. Finite element analysis software with a convergence analysis of 5% to mesh refinement was used to evaluate the effects of C/I ratio (1:1; 1.5:1; 2:1, or 2.5:1), prosthetic retention system (cemented or screwed), and restorative material (metal-ceramic or all ceramic). The crowns were loaded with simulated normal or traumatic occlusal forces. The maximum principal stress (σmax) for cortical and cancellous bone and von Mises stress (σvM) for the implant and abutment screw were computed and analyzed. The percent contribution of each variable to the stress concentration was calculated from the sum of squares analysis. Results: Traumatic occlusion and a high C/I ratio increased stress concentrations. The C/I ratio was responsible for 11.45% of the total stress in the cortical bone, whereas occlusal loading contributed 70.92% to the total stress in the implant. The retention system contributed 0.91% of the total stress in the cortical bone. The restorative material was responsible for only 0.09% of the total stress in the cancellous bone. Conclusion: Occlusal loading was the most important stress concentration factor in the finite element model of a single posterior crown supported by a short implant.
Resumo:
Background Dentoalveolar trauma, especially when involving front teeth, negatively affect the patient’s life; in particular, tooth avulsion is a complex injury that affects multiple tissues, and no treatment option offers stable long-term outcomes. The aim of this study was to report a case of reconstruction of atrophic anterior alveolar ridge after tooth loss, performed with autograft harvested from the chin, and subsequent prosthetic rehabilitation with the use of an osseointegrated implant. Case report A 23-years-old Caucasian girl, presented an atrophic alveolar bone in the area of tooth 11, as a result of tooth resorption 10 years after a tooth reimplantation procedure. Reconstruction was performed with autogenous bone harvested from the chin. After 6-months healing period to allow autograft incorporation, a dental implant was inserted. After further 6- months, a screw-retained implant supported metal-ceramic prosthesis was fabricated. Results The prosthetic rehabilitation was successful, and after a follow-up period of 5 years, the achieved result was stable.Conclusion It can be concluded that the autogenous bone graft harvested from the chin, is a safe and effective option for alveolar ridge defects reconstruction, allowing a subsequent placement of a dental implant supporting a prosthetic restoration.
Resumo:
The techniques of bone reconstruction for atrophic maxillae have been improved in order to promote bone tissue growth in both height and thickness. The grafts performed with use of autogenous bone is considered the gold standard by most researchers, for demonstrating osteogenic capacity and not to promote antigenic response. However, this type of grafting is not possible to get bone tissue in large quantity for extensive renovations. In recent years, alternatives have been researched to overcome the limitations of autogenous bone. Several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts which are obtained from individuals with different genetic load, but from the same species have been extensively used. They can be indicated in cases of arthrosplasty, surgical knee reconstruction, and large bone defects as well as in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. To rehabilitate atrophic maxillae an option that has been performed with high success rate is the reconstruction with bone graft followed by osseointegrated dental implants to rehabilitate the patient aesthetics and functionally. This paper aims to show the feasibility of allogenic bone as material for reconstruction of atrophic maxilla, and subsequent rehabilitation with metal ceramic fixed prosthesis implant and dental restoration with accompanying three years through literature review and clinical case report.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this work is the deposition of films in order to increase the corrosion resistance of AISI 304 steel, which is a material used to construct the reactors for bioethanol production. This deposition inhibits the permeation of corrosive species to the film-metal interface. Thin films were prepared by radio-frequency plasma enhanced chemical vapor deposition (RF-PECVD) method using plasmas of hexamethyldisiloxane/argon/oxygen mixtures excited by signals of different powers. The plasma was generated by the application of RF power of 13.56 MHz to the sample holder while keeping grounded the topmost electrode and the chamber walls. The effect of the RF power on the properties of the samples was investigated by perfilometry, X-ray photoelectron spectroscopy (XPS), contact angle, and electrochemical impedance spectroscopy (EIS). The results of the corrosion resistance tests of the AISI 304 steel were interpreted in terms of the energy delivered to the growing layer by plasma excitation power.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.
Resumo:
The purpose of this study was to warn the dental community about a possible problem in function with partial implant-supported prostheses used for long periods. The misalignment between natural teeth and the implant-supported prosthesis on teeth 11 and 12, observed in a 14-year clinical follow-up, illustrates the fact. The metal-ceramic crowns were placed in 1995 after a rigorous occlusal adjustment. Evaluations were made at 4, 6, 9, and 14 years, when it was noticed that the restorations were positioned palatally and extruded in comparison with the natural teeth. After 9 years, a greater discrepancy was noticed, with anterior occlusion and esthetic changes. The possible causes have been discussed: occlusal problems, parafunctional habits, and natural movement. The first 2 options were discarded after clinical analysis and diagnosis. Therefore, the natural movement probably deriving from an interaction of mechanical and genetic factors might have been the cause. The implants do not have periodontal ligaments but rather ankylosis, so they do not suffer those movements. This case emphasizes the need to inform patients that implants can last more than 10 years in function, but this is not the case with restorations, which lose function and esthetics and must be replaced.
Resumo:
Background: The aim of this study was to compare the shear bond strength between Ni-Cr alloy specimens bonded to air-abraded Ni-Cr, bur-abraded Ni-Cr, etched ceramic and etched enamel substrates using the resin cements RelyX ARC or Enforce. Materials and methods: Ni-Cr specimens were made and sandblasted with Al2O3 airborne-particles. Disc-shaped patterns were made for each of the four experimental substrates: Ni-Cr treated with Al2O3 airborne-particles, Ni-Cr treated with diamond bur abrasion, etched enamel and etched ceramic. Results: Significant differences in shear bond strength were found between the different materials and luting agents evaluated. The Ni-Cr alloy cylinders bonded to Ni-Cr surfaces sandblasted with 50 lm Al2O3 particles and bonded with Enforce achieved the highest bond strength when compared with other substrates (28.9 MPa, p < 0.05). Bur-abraded metal discs had lowest values, regardless the cement used (2.9 and 6.9 MPa for RelyX and Enforce, respectively). Etched enamel and etched ceramic had similar shear bond strengths within cement groups and performed better when RelyX was used. Conclusions: Bonding Ni-Cr to Ni-Cr and ceramic may result in similar and higher bond strength when compared to Ni-Cr/enamel bonding. For metal/metal bonding, higher shear bond strength was achieved with resin cement Enforce, and for metal/ceramic and metal/enamel bonding, RelyX had higher results.
Resumo:
O comportamento de espalhamento de quatro escórias sintéticas foi investigado pelo método da gota séssil, quando em contato com a matriz de um concreto refratário contendo alto teor de carbono e carbeto de boro como agente antioxidante. A evolução do molhamento do sólido foi monitorada a 1450, 1550 e 1650 ºC por 1800 s. Além disso, simulações termodinâmicas foram efetuadas, usando o programa FactSage®, visando promover um maior entendimento das reações químicas que podem ocorrer na interface dos materiais avaliados. Foi observado que a composição química do líquido afetou diretamente o espalhamento deste e quanto maior o teor de MgO na composição da escória, maiores foram os valores do ângulo de contato entre líquido e sólido. No entanto, em altas temperaturas e tempos prolongados, foram verificadas a formação de bolhas na superfície do líquido e a infiltração das escórias nos poros do refratário. Estes fatores afetaram negativamente e tornaram menos conclusivos os dados coletados nos ensaios propostos, apontando que ainda são necessários aperfeiçoamentos da técnica de molhabilidade para a avaliação de materiais complexos, tais como os concretos refratários.
Resumo:
AIM: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). METHODS: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench 10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bone level), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bone level). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. RESULTS: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution. CONCLUSIONS: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.
Resumo:
Die Geometrie einer Metalloberfläche bestimmt die Wechselwirkung zwischen der Oberflächenplasmonenresonanz und anderen Energieformen wie Photonen, anderen Oberflächenplasmonen und molekularen Anregungen. In dieser Arbeit wird der Einfluss dieser Effekte auf die optischen Eigenschaften von metallischen Reliefgittern untersucht.Aufgrund von Modellrechungen werden auf tiefen Gitterstrukturen Resonanzen erwartet, die sich als selbstgekoppelte Oberflächenplasmonen interpretieren lassen. Diese Resonanzen wurden aufgrund der Symmetrie des elektromagnetischen Feldes klassifiziert. Es wurden tiefe Gitter mit unterschiedlichen Profilformen hergestellt, die die experimentelle Beobachtung von drei gekoppelten Resonanzen erlauben. Variationen in der Tiefe und Asymmetrie der Gitter sowie in der experimentellen Geometrie zeigen die theoretisch vorausgesagten Effekte.Fluoreszenzfarbstoffe können mit elektromagnetischen Oberflächenresonanzen Energie austauschen. Die Lokalisierung des elektrischen Feldes von gekoppelten Resonanzen führt zu einer Ortsabhängigkeit der Kopplung, die bei 'freien' Oberflächenplasmonen nicht beobachtet wird. Ein theoretisches Modell ist in der Lage, die experimentellen Befunde weitgehend zu beschreiben. Die Ortsabhägigkeit der photochemischen Zerstörungsrate erlaubt die Anwendung dieses Effektes zur Messung von Diffusionsphänomenen in dünnen Filmen.Des weiteren wurde die Polarisationsabhängigkeit der Anregung von Oberflächenplasmonen wurde in konischer Reflexionsgeometrie und die Rolle der Oberflächenplasmonen in der thermisch induzierten Lichtemission untersucht. Ferner wurde eine vereinfachte Auswertungsroutine zur Anwendung von Gittern in der Untersuchung von dünnen dielektrischen Filmen entwickelt.
Resumo:
Im Rahmen dieser Arbeit wurden drei neue Modelle zur funktionellen Mimiese biologischer Membranen im Bereich der Bionanotechnologie entwickelt. Um den Rahmen der notwendigen Faktoren und Komponenten für biomimetische Membranmodelle abzustecken, wurde das biologische Vorbild im Bezug auf Zusammensetzung, Organisation und Funktion analysiert. Die daraus abgeleiteten Erkenntnisse erlauben das Erreichen von biologisch relevanten Membranwiderständen im Bereich von mehreren MOhm cm2 und eine gute lokale Fluidität. Ein weiteres Ziel dieser Arbeit war die Entwicklung einer Hierachie unterschiedlich stark von der Festkörperoberfläche entkoppelter Membranen zur Vergrößerung des submembranen Raumes. Diese Ziele konnten realisiert werden. Das auf archaealen Etherlipiden basierende DPTL-System wurde analog dem biologischen Vorbild stereoselektiv synthetisiert und ist in der Lage die Membran bei maximaler Elongation des TEG-Spacers mit mehr als 2 nm von der Oberfläche zu entkoppeln. Die erzielten Wiederstände liegen im hohen ein- bis zweistelligen MOhm-Bereich, die Kapazität entspricht mit 0,5 µF cm-2 ebenfalls dem Wert biologischer Membranen. Die Membraneigenschaften wurden mit Hilfe von SPS, EIS, IR-Spektroskopie, QCM, AFM und Kontaktwinkelmessungen charakterisiert. Die Funktionalität und lokale Fluidität der DPTL-Membran konnte anhand des Valinomycin vermittelten K+-Transports über die Membran gezeigt werden. Fluide Elektroden oder laterale Verdünnung mit TEGL erlauben den Einbau größerer Ionenkanäle. Lipo-Glycopolymere (LGP) mit unterschiedlichen Kettenlängen wurden mit Hilfe der kontrollierten radikalischen Polymerisation mit einer PD < 1.2 synthetisiert. Es zeigte sich, daß die Vororientierung der LGPs auf dem LB-Trog, gefolgt von einem LB-Übertrag auf einen funktionalisierten Träger mit photoreaktivem SAM, nach Belichten des Systems zu einer verlässlichen kovalenten Anbindung der supramolekularen LGP-Architektur führt. Da die Lipo-Glycopolymerketten am Glycopolymerterminus nur mit oberflächennahen Repetiereinheiten an die photoaktivierte Oberfläche binden, sind sie in der Lage Oberflächenrauhigkeiten des Festkörpersubstrates auszugleichen. Die photochemische Immobilisierung von funktionell orientierten supramolekularen LGP-Architekturen auf Goldoberflächen resultiert in tBLMs mit großen vertikalen Enkopplungen der Membran von der Festkörperoberfläche (>8 nm). Der funktionelle Ionentransport von Kaliumionen durch Valinomycin zeigt eine ausreichende lokale Fluidität der Membran die mit einem guten Membranwiderstand (mehrere MOhm) kombiniert ist. Große Membran-Oberflächenentkopplungen konnten mit Hilfe plasmapolymerisierter elektrophiler Polymere erreicht werden. Filmdicken von 50 nm sind mit homogener Oberfläche und Rauhigkeiten im Bereich von Nanometern möglich. Das System zeigt interessante fluide Eigenschaften mit guten Erholungsraten bei FRAP-Experimenten (Diffusionskonstanten von etwa 17 mikro m2 s-1). Die elektrischen Eigenschaften liegen mit Widerständen von wenigen kOhm unterhalb der für gute Membranmimikrie notwendigen Werte. Erstmalig konnte gezeigt werden, daß mit Hilfe dieser Methode inerte Polymere/Plastikträger (zum Beispiel Polypropylen und TOPAS) in effizienter Weise kovalent mit reaktiven Polymeroberflächen modifiziert werden können (Anwendung als DNA-Chip ist beschrieben).
Resumo:
When non-adsorbing polymers are added to an isotropic suspension of rod-like colloids, the colloids effectively attract each other via depletion forces. Monte Carlo simulations were performed to study the phase diagram of such rod-polymer mixtures. The colloidal rods were modelled as hard spherocylinders; the polymers were described as spheres of the same diameter as the rods. The polymers may overlap with no energy cost, while overlap of polymers and rods is forbidden. In this thesis the emphasis was on the depletion effects caused by the addition of spheres on the isotropic phase of rod-like particles. Although most of the present experimental studies consider systems close to or beyond the isotropic-nematic transition, the isotropic phase with depletion interactions turns out to be a not less interesting topic. First, the percolation problem was studied in canonical simulations of a system of hard rods and soft spheres, where the amount of depletant was kept low to prevent phase separation of the mixture. The lowering of the percolation threshold seen in experiment is confirmed to be due to the depletion interactions. The local changes in the structure of the fluid of rods, which were measured in the simulations, indicated that the depletion forces enhance local alignment and aggregation of the rods. Then, the phase diagram of isotropic-isotropic demixing of short spherocylinders was calculated using grand canonical ensemble simulations with successive umbrella sampling. Finite size scaling analysis allowed to estimate the location of the critical point. Also, estimates for the interfacial tension between the coexisting isotropic phases and analyses of its power-law behaviour on approach of the critical point are presented. The obtained phase diagram was compared to the predictions of the free volume theory. After an analysis of the bulk, the phase behaviour in confinement was studied. The critical point of gas-liquid demixing is shifted to higher concentrations of rods and smaller concentrations of spheres due to the formation of an orientationally ordered surface film. If the separation between the walls becomes very small, the critical point is shifted back to smaller concentrations of rods because the surface film breaks up. A method to calculate the contact angle of the liquid-gas interface with the wall is introduced and the wetting behaviour on the approach to the critical point is analysed.
Resumo:
III-nitride materials are very promising for high speed electronics/optical applications but still suffer in performance due to problems during high quality epitaxial growth, evolution of dislocation and defects, less understanding of fundamental physics of materials/processing of devices etc. This thesis mainly focus on GaN based heterostructures to understand the metal-semiconductor interface properties, 2DE(H)G influence on electrical and optical properties, and deep level states in GaN and InAlN, InGaN materials. The detailed electrical characterizations have been employed on Schottky diodes at GaN and InAl(Ga)N/GaN heterostructures in order to understand the metal-semiconductor interface related properties in these materials. I have observed the occurrence of Schottky barrier inhomogenity, role of dislocations in terms of leakage and creating electrically active defect states within energy gap of materials. Deep level transient spectroscopy method is employed on GaN, InAlN and InGaN materials and several defect levels have been observed related to majority and minority carriers. In fact, some defects have been found common in characteristics in ternary layers and GaN layer which indicates that those defect levels are from similar origin, most probably due to Ga/N vacancy in GaN/heterostructures. The role of structural defects, roughness has been extensively understood in terms of enhancing the reverse leakage current, suppressing the mobility in InAlN/AlN/GaN based high electron mobility transistor (HEMT) structures which are identified as key issues for GaN technology. Optical spectroscopy methods have been employed to understand materials quality, sub band and defect related transitions and compared with electrical characterizations. The observation of 2DEG sub band related absorption/emission in optical spectra have been identified and proposed for first time in nitride based polar heterostructures, which is well supported with simulation results. In addition, metal-semiconductor-metal (MSM)-InAl(Ga)N/GaN based photodetector structures have been fabricated and proposed for achieving high efficient optoelectronics devices in future.