969 resultados para Mercury, Screen printed electrode, Burkina Faso, Pollution, Groundwater
Resumo:
The chemical contamination of natural waters is a global problem with a worldwide impact. Considering the relevance of this problem, this thesis is intended, on one hand, to develop different separation/preconcentration techniques based on membranes ability to permeate anions for the transport of toxic oxyanions of chromium(VI) and arsenic contained in aqueous matrices. In particular, we have investigated supported liquid membranes and polymer inclusion membranes, both of which contain the commercial quaternary ammonium salt Aliquat 336 as a carrier, as well as commercial anion exchange membranes. On the other hand, we have focused on the development of chemical sensors to facilitate the monitoring of several metals from different aqueous matrices. Thus, a selective optical sensor for Cr(VI) based on polymeric membranes containing Aliquat 336 as an ionophore has been designed. Additionally, mercury-based screen-printed electrodes have been evaluated for for cadmium, lead, copper and zinc detection.
Resumo:
A mercury-sensitive chemically modified electrode (CME) based on modified silica gel-containing carbon paste was developed. The functional group attached to the silica gel surface was 3-(2-thiobenzimidazolyl)propyl, which is able to complex mercury ions. This electrode was applied to the determination of mercury(II) ions in aqueous solution. The mercury was chemically preconcentrated on the CME prior to voltammetric determination by anodic stripping in the differential-pulse mode. A calibration graph covering the concentration range from 0.08 to 2 mg l-1 was constructed. The precision for six determinations of 0.122 and 0.312 mg l-1 Hg(II) was 3.2 and 2.9% (relative standard deviation), respectively. The detection limit for a 5-min preconcentration period was 0.013 mg l-1. A study for foreign ions was also made.
Resumo:
A highly sensitive amperometric biosensor for determination of carbamate pesticides directly in water, fruit and vegetable samples has been evaluated, electrochemically characterized and optimized. The biosensor strip was fabricated in screen printed technique on a ceramic support using silver-based paste for reference electrode, and platinum-based paste for working and auxiliary electrodes. The working electrode was modified by a layer of carbon paste mixed with cobalt(II) phthalocyanine and acetylcellulose. Cholinesterase (ChE) enzymes with low enzymatic charge were immobilized on this layer. The operational simplicity of the biosensor consists in that a small drop (similar to 50 mu l) of substrate or sample is deposited on a horizontally positioned biosensor strip representing the microelectrochemical cell. The working potential of the biosensor was 370 mV versus Ag/AgI on a ship reference electrode preventing the interference of electroactive species which are oxidable at more positive potentials. The biosensor was applied to investigate the degradation of two reference ChE inhibitors in freeze dried water under different storage conditions and for direct determination of some N-methylcarbamates (NMCs) in fruit and vegetable samples at ppb concentration levels without any sample pretreatment. A comparison of the obtained results for the total carbamate concentration was done against those obtained using HPLC measurements. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
Suolistopatogeeniset Escherichia coli -bakteerit eli ripulikolit aiheuttavat ihmisellä suolistoinfektioita. Kuten normaalimikrobiston E. coli -bakteerit, ne esiintyvät ihmisen lisäksi muiden nisäkkäiden, etenkin märehtijöiden, ja lintujen suolistossa. Lisäksi ne voivat esiintyä maaperässä ja vesistöissä. Ihminen voi saada tartunnan eläinperäisten elintarvikkeiden välityksellä tai juomalla eläinten tai ihmisen ulosteilla saastunutta vettä. Ripulikolit voidaan jakaa ainakin viiteen ryhmään perustuen niiden erilaisiin virulenssiominaisuuksiin: enteropatogeeninen E. coli (EPEC), enterotoksigeeninen E. coli (ETEC), enterohemorraaginen E. coli (EHEC), enteroinvasiivinen E. coli (EIEC) ja enteroaggregatiivinen E. coli (EAEC). EPEC aiheuttaa etenkin kehitysmaissa pikkulapsille ripulia. ETEC aiheuttaa turistiripulia ja vastasyntyneiden ripulia kehitysmaissa. EHEC aiheuttaa ripulia tai veriripulia, joka voi varsinkin pienillä lapsilla johtaa hemolyyttis-ureemiseen oireyhtymään (HUS) ja munuaisten vaurioitumiseen. EIEC aiheuttaa Shigellan kaltaista ripulia, joka voi olla veristä. EAEC on yhdistetty lähinnä pitkittyneisiin ripuleihin. Tutkimuksessa selvitettiin suolistopatogeenisten E. coli -bakteerien esiintyvyyttä Burkina Fasossa, josta ei ole saatavilla aikaisempaa tietoa ripulikolien esiintymisestä ihmisissä ja elintarvikkeissa. Ulostenäytteitä otettiin ripulia sairastavilta alle viisivuotiailta lapsilta maaseudulta kahdesta kylästä, Boromosta ja Gourcysta, ja maan pääkaupungista Ouagadougousta (110 näytettä). Lihanäytteitä (kanaa, nautaa, lammasta ja naudan suolta, jota käytetään ihmisravinnoksi) otettiin Ouagadougoun toreilla myytävistä kypsentämättömistä lihoista (120 näytettä). Näytteistä saadut bakteerisekaviljelmät tutkittiin monialukkeisella PCR-menetelmällä, joka tunnistaa viiden ripulikoliryhmän virulenssigeenejä. Lisäksi lihanäytteistä eristettiin 20 EHEC-kantaa shigatoksiinin stx-geenin havaitsemiseen perustuvalla pesäkehybridisaatiolla ja PCR-seulonnalla, ja karakterisoitiin mahdollisten virulenssiominaisuuksien selvittämiseksi. Tutkimus osoitti, että ripulikolien aiheuttamat suolistoinfektiot ovat yleisiä ripulia sairastavilla pikkulapsilla Burkina Fasossa. Ulostenäytteistä 59 % oli positiivisia. Useimmiten lapsilla esiintyi EAEC- (32 %) ETEC- (31 %) ja EPEC-patoryhmiä (20 %). EIEC- (2 %) ja EHEC-patoryhmiä (1 %) esiintyi vähän. Myös useamman patoryhmän sekainfektiot olivat yleisiä (24 %). Eri paikkakuntien välillä oli tilastollisesti merkitseviä eroja ripulikolien esiintymisessä. Gourcyssa ripulikoleja esiintyi useammin kuin Ouagadougoussa ja Boromossa. Tutkimuksessa kävi ilmi, että Ouagadougoun toreilla myytävissä lihoissa on paljon ripulikoleja. Lihanäytteistä 43 % oli positiivisia. Yleisimmin lihoissa esiintyi EHEC (28 %), EPEC (20 %), ETEC (8 %) ja EAEC (5 %). EIEC-ryhmää ei havaittu lihoissa. Myös useamman patoryhmän sekakontaminaatioita löytyi (17 %) lihoista. Ripulikolien esiintyvyydessä eri lihojen välillä ei ollut tilastollisesti merkitseviä eroja, kun tarkasteltiin kaikkia patoryhmiä yhdessä. Eri patoryhmien esiintyvyyttä tarkasteltaessa EHEC-patoryhmää ei esiintynyt ollenkaan kanassa ja ero oli tilastollisesti merkitsevä muihin lihoihin verrattuna. Lihoista eristetyt 20 EHEC-kantaa kuuluivat 14 eri serotyyppiin, joista osa on aikaisemmin eristetty suolistoinfektioihin ja HUSoireyhtymään sairastuneilta ihmisiltä. Kaikki kannat olivat stx1-positiivisia ja puolella oli lisäksi stx2-geeni, jota pidetään shigatoksiinin virulentimpana muotona. Kahdelta EHEC-kannalta löytyi myös ETECpatoryhmän lämpöstabiilin enterotoksiini Ia:n geeni eli kannat olivat kahden patoryhmän välimuotoa ja osoitus geenien siirtymisestä eri patoryhmien välillä. Vaikka nuorimmat näytteen antaneet lapsipotilaat tuskin söivät lihaa, sen voidaan ajatella silti olevan edustava näyte lasten elinympäristöstä, sillä lasten ruoka valmistetaan usein samoissa oloissa, joissa raakaa lihaa käsitellään. Saastunut liha voi siten olla pikkulasten ripulikoli-infektioiden aiheuttaja.
Resumo:
Graphene nanosheets, dispersed in Nafion (Nafion-G) solution, were used in combination with in situ plated bismuth film electrode for fabricating the enhanced electrochemical sensing platform to determine the lead (Pb2+) and cadmium (Cd2+) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the composite film modified glassy carbon electrode were investigated. It is found that the prepared Nafion-G composite film not only exhibited improved sensitivity for the metal ion detections, but also alleviated the interferences due to the synergistic effect of graphene nanosheets and Nafion. The linear calibration curves ranged from 0.5 mu g L-1 to 50 mu g L-1 for Pb2+ and 1.5 mu g L-1 to 30 mu g L-1 for Cd2+. respectively. The detection limits (S/N = 3) were estimated to be around 0.02 mu g L-1 for Pb2+ and Cd2+. The practical application of the proposed method was verified in the water sample determination.
Resumo:
Improvement of the sensitivity of electrochemical sandwich enzyme immunoassay has been achieved by electrodepositing redox polymer on screen-printed carbon electrode surface, on which the sandwich complex was formed.
Resumo:
The work presented in this thesis described the development of low-cost sensing and separation devices with electrochemical detections for health applications. This research employs macro, micro and nano technology. The first sensing device developed was a tonerbased micro-device. The initial development of microfluidic devices was based on glass or quartz devices that are often expensive to fabricate; however, the introduction of new types of materials, such as plastics, offered a new way for fast prototyping and the development of disposable devices. One such microfluidic device is based on the lamination of laser-printed polyester films using a computer, printer and laminator. The resulting toner-based microchips demonstrated a potential viability for chemical assays, coupled with several detection methods, particularly Chip-Electrophoresis-Chemiluminescence (CE-CL) detection which has never been reported in the literature. Following on from the toner-based microchip, a three-electrode micro-configuration was developed on acetate substrate. This is the first time that a micro-electrode configuration made from gold; silver and platinum have been fabricated onto acetate by means of patterning and deposition techniques using the central fabrication facilities in Tyndall National Institute. These electrodes have been designed to facilitate the integration of a 3- electrode configuration as part of the fabrication process. Since the electrodes are on acetate the dicing step can automatically be eliminated. The stability of these sensors has been investigated using electrochemical techniques with excellent outcomes. Following on from the generalised testing of the electrodes these sensors were then coupled with capillary electrophoresis. The final sensing devices were on a macro scale and involved the modifications of screenprinted electrodes. Screen-printed electrodes (SPE) are generally seen to be far less sensitive than the more expensive electrodes including the gold, boron-doped diamond and glassy carbon electrodes. To enhance the sensitivity of these electrodes they were treated with metal nano-particles, gold and palladium. Following on from this, another modification was introduced. The carbonaceous material carbon monolith was drop-cast onto the SPE and then the metal nano-particles were electrodeposited onto the monolith material
Resumo:
We report a simple and facile methodology for constructing Pt (6.3 mm x 50 mu m) and Cu (6.3 mm x 30 mu m) annular microband electrodes for use in room temperature ionic liquids (RTILs) and propose their use for amperometric gas sensing. The suitability of microband electrodes for use in electrochemical analysis was examined in experiments on two systems. The first system studied to validate the electrochemical responses of the annular microband electrode was decamethylferrocene (DmFc), as a stable internal reference probe commonly used in ionic liquids, in [Pmim][NTf2], where the diffusion coefficients of DmFc and DmFc(+) and the standard electron rate constant for the DmFc/DmFc(+) couple were determined through fitting chronoamperometric and cyclic voltammetric responses with relevant simulations. These values are independently compared with those collected from a commercially available Pt microdisc electrode with excellent agreement. The second system focuses on O-2 reduction in [Pmim][NTf2], which is used as a model for gas sensing. The diffusion coefficients of O-2 and O-2(-) and the electron transfer rate constant were again obtained using chronoamperometry and cyclic voltammetry, along with simulations. Results determined from the microbands are again consistent to those evaluated from the Pt microdisc electrode when compared these results from home-made microband and commercially available microdisc electrodes. These observations indicate that the fabricated annular microband electrodes are suitable for quantitative measurements. Further the successful use of the Cu electrodes in the O-2 system suggests a cheap disposable sensor for gas detection. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.
Resumo:
The use of anodic stripping voltammetry (ASV)has been proven in the past to be a precise and sensitive analytical method with an excellent limit of detection. Electrochemical sensors could help to avoid expensive and time consuming procedures as sample taking and storage and provide a both sensitive and reliable method for the direct monitoring of heavy metals in the aquatic environment. Solid electrodes which have been used in this work, were produced using previously developed methods. Commercially available and newly designed, screen printed carbon and gold plated working electrodes (WE) were compared. Good results were achieved with the screen printed and plated electrodes under conditions optimized for each electrode material. The electrode stability, reproducibility of single measurements and the limit of detection obtained for Pb were satisfactory (3*10-6mol/l on screen printed carbon WEs after 60 s of deposition and 6*10-6 mol/l on gold plated WEs after 5 min of deposition). Complete 3-electrode-sets (counter, reference and working electrode) were screen printed on different substrates (glass, polycarbonate and alumina). Also here, both carbon and gold were used as WE. Using 3-electrode-sets with a gold plated WE on glass was a limit of detection of 7*10-7 mol/l was achieved after only 60 s of deposition.
Resumo:
Disposable screen-printed electrodes (SPCE) were modified using a cosmetic product to partially block the electrode surface in order to obtain a microelectrode array. The microarrays formed were electropolymerized with aniline. Scanning electron microscopy was used to evaluate the modified and polymerized electrode surface. Electrochemical characteristics of the constructed sensor for cadmium analysis were evaluated by cyclic and square-wave voltammetry. Optimized stripping procedure in which the preconcentration of cadmium was achieved by depositing at –1.20 V (vs. Ag/AgCl) resulted in a well defined anodic peak at approximately –0.7 V at pH 4.6. The achieved limit of detection was 4 × 10−9 mol dm−3. Spray modified and polymerized microarray electrodes were successfully applied to quantify cadmium in fish sample digests.
Resumo:
Human epidermal growth factor receptor 2 (HER2) is a breast cancer biomarker that plays a major role in promoting breast cancer cell proliferation and malignant growth. The extracellular domain (ECD) of HER2 can be shed into the blood stream and its concentration is measurable in the serum fraction of blood. In this work an electrochemical immunosensor for the analysis of HER2 ECD in human serum samples was developed. To achieve this goal a screen-printed carbon electrode, modified with gold nanoparticles, was used as transducer surface. A sandwich immunoassay, using two monoclonal antibodies, was employed and the detection of the antibody–antigen interaction was performed through the analysis of an enzymatic reaction product by linear sweep voltammetry. Using the optimized experimental conditions the calibration curve (ip vs. log[HER2 ECD]) was established between 15 and 100 ng/mL and a limit of detection (LOD) of 4.4 ng/mL was achieved. These results indicate that the developed immunosensor could be a promising tool in breast cancer diagnostics, patient follow-up and monitoring of metastatic breast cancer since it allows quantification in a useful concentration range and has an LOD below the established cut-off value (15 ng/mL).
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
In the present work, the development of a genosensor for the event-specific detection of MON810 transgenic maize is proposed. Taking advantage of nanostructuration, a cost-effective three dimensional electrode was fabricated and a ternary monolayer containing a dithiol, a monothiol and the thiolated capture probe was optimized to minimize the unspecific signals. A sandwich format assay was selected as a way of precluding inefficient hybridization associated with stable secondary target structures. A comparison between the analytical performance of the Au nanostructured electrodes and commercially available screen-printed electrodes highlighted the superior performance of the nanostructured ones. Finally, the genosensor was effectively applied to detect the transgenic sequence in real samples, showing its potential for future quantitative analysis.
Resumo:
Polychaete worms are abundant in many mudflats but their importance to coastal food web Hg biomagnification is not known. We sampled sediments and polychaete worms from mudflats in the Bay of Fundy to investigate the bioaccumulation of mercury (Hg) and methylmercury (MeHg) in the coastal invertebrate food web. Hg concentrations in the sediments were low (<20 μg kg−1). Labile Hg (methanol/KOH sediment extraction) in surface sediments (0–1 cm) was positively correlated with Hg bioaccumulation by surface sediment-ingesting polychaetes but, surprisingly, there was a negative correlation between δ15N (i.e. trophic level) and THg bioaccumulation factors in polychaete worms. Worms feeding on deeper sediments contained the greatest MeHg concentrations (69.6 μg kg−1). Polychaetes are an important vector for Hg biomagnification to the coastal avian food web. This research demonstrates that feeding depth and method of feeding are more important than trophic position or sediment Hg concentrations for predicting Hg bioaccumulation.