855 resultados para Measurement in Bacteriology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fine needle aspiration cytology (FNAC) is the more accurate diagnostic method for cervical lymph node (CLN) metastasis from differentiated thyroid cancers (DTC). However, FNAC diagnosis of cystic CLN is, in most cases, uninformative due to inadequate cellularity. Recently, thyroglobulin (Tg) detection in FNAC needle washout fluid has been shown to improve the diagnostic accuracy of FNAC, and its routine association with cytology is recommended. We here describe the case of a 20 yr old girl complaining of the recent appearance of palpable non-painful laterocervical nodes in the neck. Ultrasound examination revealed the presence of 3 cystic CLNs and 2 mixed thyroid nodules, with the larger one showing irregular margins. On the latter, and on 2 larger CLNs, FNAC was performed, and both Tg protein and mRNA were determined in the needle washout. The cytological analysis was not diagnostic for the two CLNs, while that of the thyroid nodule reported the presence of colloid and groups of thyrocytes with normal morphology. Both CLNs showed, however, high levels of Tg protein and were positive for Tg mRNA, suggestive of metastatic DTC. Based on these findings, the FNAC analysis was performed on the second smaller thyroid nodule suggesting (Tir4) the presence of PTC. The patient was then subjected to total thyroidectomy with lymph nodes resection of the central and homolateral compartments. The histological diagnosis confirmed the presence of a PTC in the small nodule and metastatic lymph nodes. In conclusion, this case confirms that the cytological diagnosis of cystic lymph nodes is challenging, and that the measurement of Tg protein and/or mRNA in the needle washout may overcome this limitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Passive sampling devices (PS) are widely used for pollutant monitoring in water, but estimation of measurement uncertainties by PS has seldom been undertaken. The aim of this work was to identify key parameters governing PS measurements of metals and their dispersion. We report the results of an in situ intercomparison exercise on diffusive gradient in thin films (DGT) in surface waters. Interlaboratory uncertainties of time-weighted average (TWA) concentrations were satisfactory (from 28% to 112%) given the number of participating laboratories (10) and ultra-trace metal concentrations involved. Data dispersion of TWA concentrations was mainly explained by uncertainties generated during DGT handling and analytical procedure steps. We highlight that DGT handling is critical for metals such as Cd, Cr and Zn, implying that DGT assembly/dismantling should be performed in very clean conditions. Using a unique dataset, we demonstrated that DGT markedly lowered the LOQ in comparison to spot sampling and stressed the need for accurate data calculation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pouchitis is the most common complication following proctocolectomy with ileal pouch-anal anastomosis for ulcerative colitis (UC). To provide a standardized definition of pouchitis clinical, endoscopic and histological markers were grouped and weighted in the pouch disease activity index (PDAI). However, the delay in the assessment of the final score due to the time requested for histological analysis remains the main obstacle to the index implementation in clinical practice so that the use of modified-PDAI (mPDAI) with exclusion of histologic subscore has been proposed. We tested the ability of calprotectin measurement in the pouch endoluminal content to mimic the histologic score as defined in the PDAI, the index that we adopted as gold standard for pouchitis diagnosis. Calprotectin was measured by ELISA in the pouch endoluminal content collected during endoscopy in 40 consecutive patients with J-pouch. In each patient PDAI and mPDAI were calculated and 15% of patients were erroneously classified by mPDAI. ROC analysis of calprotectin values vs. acute histological subscore ≥ 3 identified different calprotectin cut-off values with corresponding sensitivity and specificity allowing the definition and scoring of different range of calprotectin subscores. We incorporated the calprotectin score in the mPDAI obtaining a new score that shows the same specificity as PDAI for diagnosis of pouchitis and higher sensitivity when compared with mPDAI. The use of the proposed new score, once validated in a larger series of patients, might be useful in the early management of patients with symptoms of pouchitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The changes in time and location of surface temperature from a water body has an important effect on climate activities, marine biology, sea currents, salinity and other characteristics of the seas and lakes water. Traditional measurement of temperature is costly and time consumer due to its dispersion and instability. In recent years the use of satellite technology and remote sensing sciences for data acquiring and parameter and lysis of climatology and oceanography is well developed. In this research we used the NOAA’s Satellite images from its AVHRR system to compare the field surface temperature data with the satellite images information. Ten satellite images were used in this project. These images were calibrated with the field data at the exact time of satellite pass above the area. The result was a significant relation between surface temperatures from satellite data with the field work. As the relative error less than %40 between these two data is acceptable, therefore in our observation the maximum error is %21.2 that can be considered it as acceptable. In all stations the result of satellite measurements is usually less than field data that cores ponds with the global result too. As this sea has a vast latitude, therefore the different in the temperature is natural. But we know this factor is not the only cause for surface currents. The information of all satellites were images extracted by ERDAS software, and the “Surfer” software is used to plot the isotherm lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advances in mobile phone cameras have poised them to take over compact hand-held cameras as the consumer’s preferred camera option. Along with advances in the number of pixels, motion blur removal, face-tracking, and noise reduction algorithms have significant roles in the internal processing of the devices. An undesired effect of severe noise reduction is the loss of texture (i.e. low-contrast fine details) of the original scene. Current established methods for resolution measurement fail to accurately portray the texture loss incurred in a camera system. The development of an accurate objective method to identify the texture preservation or texture reproduction capability of a camera device is important in this regard. The ‘Dead Leaves’ target has been used extensively as a method to measure the modulation transfer function (MTF) of cameras that employ highly non-linear noise-reduction methods. This stochastic model consists of a series of overlapping circles with radii r distributed as r−3, and having uniformly distributed gray level, which gives an accurate model of occlusion in a natural setting and hence mimics a natural scene. This target can be used to model the texture transfer through a camera system when a natural scene is captured. In the first part of our study we identify various factors that affect the MTF measured using the ‘Dead Leaves’ chart. These include variations in illumination, distance, exposure time and ISO sensitivity among others. We discuss the main differences of this method with the existing resolution measurement techniques and identify the advantages. In the second part of this study, we propose an improvement to the current texture MTF measurement algorithm. High frequency residual noise in the processed image contains the same frequency content as fine texture detail, and is sometimes reported as such, thereby leading to inaccurate results. A wavelet thresholding based denoising technique is utilized for modeling the noise present in the final captured image. This updated noise model is then used for calculating an accurate texture MTF. We present comparative results for both algorithms under various image capture conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Service development is guided by outcome measures that inform service commissioners and providers. Those in liaison psychiatry should be encouraged to develop a positive approach that integrates the collection of outcome measures into everyday clinical practice. The Framework for Routine Outcome Measurement in Liaison Psychiatry (FROM-LP) is a very useful tool to measure service quality and clinical effectiveness, using a combination of clinician-rated and patient-rated outcome measures and patient-rated experience measures. However, it does not include measures of cost-effectiveness or training activities. The FROM-LP is a significant step towards developing nationally unified outcome measures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Congenital vertebral malformations are common in brachycephalic “screw-tailed” dog breeds such as French bulldogs, English bulldogs, Boston terriers, and Pugs. Those vertebral malformations disrupt the normal vertebral column anatomy and biomechanics, potentially leading to deformity of the vertebral column and subsequent neurological dysfunction. The initial aim of this work was to study and determine whether the congenital vertebral malformations identified in those breeds could be translated in a radiographic classification scheme used in humans to give an improved classification, with clear and well-defined terminology, with the expectation that this would facilitate future study and clinical management in the veterinary field. Therefore, two observers who were blinded to the neurologic status of the dogs classified each vertebral malformation based on the human classification scheme of McMaster and were able to translate them successfully into a new classification scheme for veterinary use. The following aim was to assess the nature and the impact of vertebral column deformity engendered by those congenital vertebral malformations in the target breeds. As no gold standard exists in veterinary medicine for the calculation of the degree of deformity, it was elected to adapt the human equivalent, termed the Cobb angle, as a potential standard reference tool for use in veterinary practice. For the validation of the Cobb angle measurement method, a computerised semi-automatic technique was used and assessed by multiple independent observers. They observed not only that Kyphosis was the most common vertebral column deformity but also that patients with such deformity were found to be more likely to suffer from neurological deficits, more especially if their Cobb angle was above 35 degrees.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of Cobb angles from radiographs is routine practice in spinal clinics. The technique relies on the use and availability of specialist equipment such as a goniometer, cobbometer or protractor. The aim of this study was to validate the use of i-Phone (Apple Inc) combined with Tilt Meter Pro software as compared to a protractor in the measurement of Cobb angles. Between November 2008 and December 2008 20 patients were selected at random from the Paediatric Spine Research Groups Database. A power calculation was performed which indicated if n=240 measurements the study had a 96% chance of detecting a 5 degree difference between groups. All patients had idiopathic scoliosis with a range of curve types and severities. The study found the i-Phone combined with Tilt Meter Pro software offers a faster alternative to the traditional method of Cobb angle measurement. The use of i-Phone offers a more convenient way of measuring Cobb angles in the outpatient setting. The intra-observer repeatability of the iPhone is equivalent to the protractor in the measurement of Cobb angles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of Cobb angles on radiographs of patients with spinal deformities is routine practice in spinal clinics. The technique relies on the use and availability of specialist equipment such as a goniometer, cobbometer or protractor. The aim of this study was to validate the use of i-Phone (Apple Inc) combined with Tilt Meter Pro software as compared to a protractor in the measurement of Cobb angles. The i-Phone combined with Tilt Meter Pro software offers a faster alternative to the traditional method of Cobb angle measurement. The use of i-Phone offers a more convenient way of measuring Cobb angles in the outpatient setting. The intra-observer repeatability of the iPhone is equivalent to the protractor in the measurement of Cobb angles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inter-Vehicular Communications (IVC) are considered a promising technological approach for enhancing transportation safety and improving highway efficiency. Previous theoretical work has demonstrated the benefits of IVC in vehicles strings. Simulations of partially IVC-equipped vehicles strings showed that only a small equipment ratio is sufficient to drastically reduce the number of head on collisions. However, these results are based on the assumptions that IVC exhibit lossless and instantaneous messages transmission. This paper presents the research design of an empirical measurement of a vehicles string, with the goal of highlighting the constraints introduced by the actual characteristics of communication devices. A warning message diffusion system based on IEEE 802.11 wireless technology was developed for an emergency breaking scenario. Preliminary results are presented as well, showing the latencies introduced by using 802.11a and discussing early findings and experimental limitations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses one of the foundational components of beginning infernce, namely variation, with 5 classes of Year 4 students undertaking a measurement activity using scaled instruments in two contexts: all students measuring one person's arm span and recording the values obtained, and each student having his/her own arm span measured and recorded. The results included documentation of students' explicit appreciation of the variety of ways in which varitation can occur, including outliers, and their ability to create and describe valid representations of their data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was based on the premise that variation is the foundation of statistics and statistical investigations. The study followed the development of fourth-grade students' understanding of variation through participation in a sequence of two lessons based on measurement. In the first lesson all students measured the arm span of one student, revealing pathways students follow in developing understanding of variation and linear measurement (related to research question 1). In the second lesson each student's arm span was measured once, introducing a different aspect of variation for students to observe and contrast. From this second lesson, students' development of the ability to compare their representations for the two scenarios and explain differences in terms of variation was explored (research question 2). Students' documentation, in both workbook and software formats, enabled us to monitor their engagement and identify their increasing appreciation of the need to observe, represent, and contrast the variation in the data. Following the lessons, a written student assessment was used for judging retention of understanding of variation developed through the lessons and the degree of transfer of understanding to a different scenario (research question 3).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The short duration of the Doppler signal and noise content in it necessitate a validation scheme to be incorporated in the electronic processor used for frequency measurement, There are several different validation schemes that can be employed in period timing devices. A detailed study of the influence of these validation schemes on the measured frequency has been reported here. These studies were carried out by using a combination of a fast A/D converter and computer. Doppler bursts obtained from an air flow were digitised and stored on magnetic discs. Suitable computer programs were then used to simulate the performance of period timing devices with different validation schemes and the frequency of the stored bursts were evaluated. It is found that best results are obtained when the validation scheme enables frequency measurement to be made over a large number of cycles within the burst.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aerodynamic forces and fore-body convective surface heat transfer rates over a 60 degrees apex-angle blunt cone have been simultaneously measured at a nominal Mach number of 5.75 in the hypersonic shock tunnel HST2. An aluminum model incorporating a three-component accelerometer-based balance system for measuring the aerodynamic forces and an array of platinum thin-film gauges deposited on thermally insulating backing material flush mounted on the model surface is used for convective surface heat transfer measurement in the investigations. The measured value of the drag coefficient varies by about +/-6% from the theoretically estimated value based on the modified Newtonian theory, while the axi-symmetric Navier-Stokes computations overpredict the drag coefficient by about 9%. The normalized values of measured heat transfer rates at 0 degrees angle of attack are about 11% higher than the theoretically estimated values. The aerodynamic and the heat transfer data presented here are very valuable for the validation of CFD codes used for the numerical computation of How fields around hypersonic vehicles.