286 resultados para Mammography
Resumo:
Studies conducted in different areas of North America and Europe showed a 5-10% decline in the incidence of breast cancer following reductions up to 70% in menopause hormone therapy (HT) use after 2002. The observation that the decline was larger in (or limited to) women aged > or =50 years weighs in favour of an effect of reduced HT use on breast cancer incidence. However, changes in screening are also likely to play a role in the decreasing incidence of breast cancer observed in several countries. In particular, the technical improvements and the increased effectiveness of breast cancer screening and detection during the 1990s led to a decreased number of pre-clinical cases found by screening in subsequent years. Further, disentangling the effects of HT use and screening is difficult, as women who stop using HT may also undergo mammography screening less frequently. Thus, the reasons of the falls in incidence remain open to discussion.
Resumo:
Quality assurance is an essential process which should be applied for any organised breast cancer screening program since mammography it the only test available for an early diagnosis. It should also assess the quality of diagnostic and treatment processes in order to ascertain that the quality of the screening program would not be altered by the procedures which take place after the screening. Quality assurance must be applied to each component of the screening process: equipment, radiographers (technicians) as well as radiologists. It is a multidisciplinary approach following a well defined protocol, which should be supervised by a coordination unit, the Breast Cancer Screening Foundation in Canton of Vaud. Performances of the Vaud program show clearly at what extend multiple reading method improves the quality of screening. It seems that there is no inconvenient to involve radiologists who wish to participate without any selection to the reading process provided that there is in place a team of 2nd and 3rd readers who benefit of an appropriate training and experience.
Resumo:
[Résumé (extrait)] Lancé en octobre 1999, le Programme valaisan de dépistage du cancer du sein a pour mission de promouvoir, d'organiser et de mener une action de dépistage auprès de la population féminine valaisanne âgée de 50 à 70 ans. Ce programme est régulièrement évalué, de manière indépendante, afin de s'assurer que sa qualité et son efficacité répondent à des normes internationalement admises tout en minimisant ses effets adverses. Ces évaluations ont mis en évidence un niveau de performances globalement satisfaisant et suggéré un potentiel d'amélioration, notamment de la qualité des lectures radiologiques. Dans un souci d'optimiser les performances, la direction du Programme a mené ces dernières années plusieurs actions auprès de ses radiologues et pris quelques mesures. Ce rapport thématique traite de l'évolution des performances du programme, principalement au cours de la dernière décennie (2002-11), c'est-à-dire après sa phase de démarrage (1999-2001). Les tendances des principaux indicateurs de performance et leurs associations avec les actions et mesures réalisées, qui ont été répertoriées et classées selon leur types et objectifs, sont analysées. Les facteurs les plus influents sur la qualité des lectures radiologiques sont quantifiés de manière à faciliter toute décision interventionnelle. Les cancers d'intervalle (1999-2010) du Programme sont étudiés afin d'en apprécier la fréquence, d'en établir le profil pronostique et de déterminer les caractéristiques clinicoépidémiologiques qui les distinguent des cancers dépistés dans le cadre du Programme.
Resumo:
Several diseases can be prevented either by primary prevention, such as immunisation or behavioural counselling, or secondary prevention such as screening. The new clinical recommendations include screening of abdominal aortic aneurysm among male smokers and ex-smokers aged between 65 and 75 years and the extension of breast cancer screening by mammography for women aged between 40 and 49 years, as well as screening for diabetes among patients with hypertension or dyslipidemia.
Resumo:
For several years now, substantial efforts have been devoted to the development and the implementation of a screening program for breast cancer in the Canton of Vaud. A four-year pilot phase is now starting, involving two regional hospitals with their catchment areas; women over 50 and under 70 years old will be invited to participate in the program. A double view mammography will be made, with a double reading made by the hospital radiologists; a third reading will be made in case of discrepancy between the two first radiologists. Patients classified as positive for screening (e.g., with a suspect radiological image) will be referred to their practitioner for further diagnosis and treatment. The medical and public health background of this program is discussed, more specifically the reasons for developing a screening program, the choice of mammography rather than other tools, and the need to implement screening as an organized program.
Resumo:
Le Programme de dépistage du cancer du sein BEJUNE a démarré en mai 2005 dans le canton du Jura, s'est étendu au canton de Neuchâtel en mai 2007 et englobe le Jura bernois depuis janvier 2009. Ses buts sont de promouvoir, organiser, gérer et mener à bien une action de dépistage auprès de la population féminine dans la tranche d'âge de 50 à 69 ans révolus (environ 42'000 femmes). [...] Ce rapport constitue, après 5 ans et demi d'activité, la première évaluation épidémiologique du Programme de dépistage du cancer du sein BEJUNE. Cette évaluation a été réalisée par l'Unité d'épidémiologie du cancer (UEC) de l'Institut universitaire de médecine sociale et préventive de Lausanne (IUMSP) qui jouit d'une longue expérience dans le domaine. Dans ce rapport, on analyse le fonctionnement, la participation, la qualité et l'efficacité précoce du programme. Les indicateurs de performance retenus suivent les recommandations européennes et les directives émises par la Fédération suisse des programmes de dépistage du cancer du sein. Entre mai 2005 et novembre 2010, plus de 37'000 mammographies ont été réalisées dans 11 Centres/Instituts de radiologie. Les 6750 examens effectués annuellement correspondent à un volume de 420 mammographies par radiologue: 380 pour les 1e lecteurs et 1300 pour les 2e lecteurs (auxquels s'ajoutent les lectures réalisées dans le cadre d'un autre programme cantonal). [...] [Auteurs, p. 5]
Resumo:
A nation-wide survey on radiation doses in diagnostic and interventional radiology was conducted in Switzerland in 1998 aiming at establishing their collective radiological impact on the Swiss population. The study consisted on the one hand of surveying the frequency of more than 250 types of examinations, covering conventional radiology, mammography, fluoroscopy, angiography, interventional radiology, CT, bone densitometry, conventional tomography and dental radiology. On the other hand, for each type of examination the associated patient dose was established by modeling. The results of this study show that about 9.5 million diagnostic and interventional examinations are performed annually in Switzerland (1.34 per caput) and that the associated annual collective dose is of the order of 7100 person.Sv (1.0 mSv per caput). Switzerland is similar to other European countries in terms of the frequency of examinations and the collective dose.
Resumo:
The knowledge of the relationship that links radiation dose and image quality is a prerequisite to any optimization of medical diagnostic radiology. Image quality depends, on the one hand, on the physical parameters such as contrast, resolution, and noise, and on the other hand, on characteristics of the observer that assesses the image. While the role of contrast and resolution is precisely defined and recognized, the influence of image noise is not yet fully understood. Its measurement is often based on imaging uniform test objects, even though real images contain anatomical backgrounds whose statistical nature is much different from test objects used to assess system noise. The goal of this study was to demonstrate the importance of variations in background anatomy by quantifying its effect on a series of detection tasks. Several types of mammographic backgrounds and signals were examined by psychophysical experiments in a two-alternative forced-choice detection task. According to hypotheses concerning the strategy used by the human observers, their signal to noise ratio was determined. This variable was also computed for a mathematical model based on the statistical decision theory. By comparing theoretical model and experimental results, the way that anatomical structure is perceived has been analyzed. Experiments showed that the observer's behavior was highly dependent upon both system noise and the anatomical background. The anatomy partly acts as a signal recognizable as such and partly as a pure noise that disturbs the detection process. This dual nature of the anatomy is quantified. It is shown that its effect varies according to its amplitude and the profile of the object being detected. The importance of the noisy part of the anatomy is, in some situations, much greater than the system noise. Hence, reducing the system noise by increasing the dose will not improve task performance. This observation indicates that the tradeoff between dose and image quality might be optimized by accepting a higher system noise. This could lead to a better resolution, more contrast, or less dose.
Resumo:
ABSTRACT: INTRODUCTION: Dermatofibrosarcoma protuberans is a rare neoplasm of soft tissues and its location in the breast is extremely uncommon. Confusion is possible with other primary breast lesions. CASE PRESENTATION: A 75-year-old Caucasian woman presented with a mass in her left breast 21 years after being diagnosed with invasive ductal carcinoma of the right breast, treated by a right mastectomy and axillary dissection followed by radiotherapy and breast reconstruction. Mammography revealed a dish-shaped skin nodule formation in the upper outer quadrant of her left breast. Echography confirmed the presence of a lesion measuring 1.4 x 0.8 cm. Based on imaging, the diagnosis was a probable angiosarcoma. Due to the presence of a pacemaker for cardiac arrhythmia and full anticoagulation therapy for a pulmonary embolism, magnetic resonance imaging and a biopsy were not done. We proceeded directly to a quadrantectomy and the final diagnosis revealed a dermatofibrosarcoma protuberans, 1. 8 cm in its greatest microscopic dimension, located 0.1 cm from the upper surgical margin. To ensure the wide resection margins required for this type of neoplasm, a re-excision was performed. CONCLUSION: A dermatofibrosarcoma protuberans of the breast is an uncommon discovery. The aim of this case report is to highlight the importance of the surgical procedure in cases of the discovery of dermatofibrosarcoma protuberans. Re-excision may be necessary to ensure adequate resection margins.
Resumo:
L'objectif de ce travail est le développement d'une méthode de caractérisation objective de la qualité d'image s'appliquant à des systèmes de mammographie analogique, utilisant un couple écran-film comme détecteur, et numérique, basé sur une technologie semi-conductrice, ceci en vue de la comparaison de leurs performances. La méthode développée tient compte de la gamme dynamique du détecteur, de la détectabilité de structures de haut contraste, simulant des microcalcifications, et de structures de bas contraste, simulant des opacités (nodules tumoraux). La méthode prend également en considération le processus de visualisation de l'image, ainsi que la réponse de l'observateur. Pour réaliser ceci, un objet-test ayant des propriétés proches de celles d'un sein comprimé, composé de différents matériaux équivalents aux tissus, allant du glandulaire à l'adipeux, et comprenant des zones permettant la simulation de structures de haut et bas contraste, ainsi que la mesure de la résolution et celle du bruit, a été développé et testé. L'intégration du processus de visualisation a été réalisée en utilisant une caméra CCD mesurant directement les paramètres de qualité d'image, à partir de l'image de l'objet-test, dans une grandeur physique commune au système numérique et analogique, à savoir la luminance arrivant sur l'oeil de l'observateur. L'utilisation d'une grandeur synthétique intégrant dans un même temps, le contraste, le bruit et la résolution rend possible une comparaison objective entre les deux systèmes de mammographie. Un modèle mathématique, simulant la réponse d'un observateur et intégrant les paramètres de base de qualité d'image, a été utilisé pour calculer la détectabilité de structures de haut et bas contraste en fonction du type de tissu sur lequel celles-ci se trouvent. Les résultats obtenus montrent qu'à dose égale la détectabilité des structures est significativement plus élevée avec le système de mammographie numérique qu'avec le système analogique. Ceci est principalement lié au fait que le bruit du système numérique est plus faible que celui du système analogique. Les résultats montrent également que la méthodologie, visant à comparer des systèmes d'imagerie numérique et analogique en utilisant un objet-test à large gamme dynamique ainsi qu'une caméra, peut être appliquée à d'autres modalités radiologiques, ainsi qu'à une démarche d'optimisation des conditions de lecture des images.<br/><br/>The goal of this work was to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality and patient dose. We propose a method that takes into account the dynamic range of the image detector and the detection of high contrast (for microcalcifications) and low contrast (for masses or tumoral nodules) structures. The method also addresses the problems of image visualization and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution, and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualization process in the image quality assessment. In this way the luminance reaching the viewer?s eyes can be controlled for both kinds of images. A global quantity describing image contrast, spatial resolution and noise, and expressed in terms of luminance at the camera, can then be used to compare the two technologies objectively. The quantity used was a mathematical model observer that calculates the detectability of high and low contrast structures as a function of the background tissue. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. This is mainly because the image noise is lower for the digital system than for the screen-film detector. The method of using a test object with a large dynamic range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimize the process of radiographic film reading.
Resumo:
Introduction: Early detection of breast cancer (BC) with mammography may cause overdiagnosis and overtreatment, detecting tumors which would remain undiagnosed during a lifetime. The aims of this study were: first, to model invasive BC incidence trends in Catalonia (Spain) taking into account reproductive and screening data; and second, to quantify the extent of BC overdiagnosis. Methods: We modeled the incidence of invasive BC using a Poisson regression model. Explanatory variables were: age at diagnosis and cohort characteristics (completed fertility rate, percentage of women that use mammography at age 50, and year of birth). This model also was used to estimate the background incidence in the absence of screening. We used a probabilistic model to estimate the expected BC incidence if women in the population used mammography as reported in health surveys. The difference between the observed and expected cumulative incidences provided an estimate of overdiagnosis. Results: Incidence of invasive BC increased, especially in cohorts born from 1940 to 1955. The biggest increase was observed in these cohorts between the ages of 50 to 65 years, where the final BC incidence rates more than doubled the initial ones. Dissemination of mammography was significantly associated with BC incidence and overdiagnosis. Our estimates of overdiagnosis ranged from 0.4% to 46.6%, for women born around 1935 and 1950, respectively. Conclusions: Our results support the existence of overdiagnosis in Catalonia attributed to mammography usage, and the limited malignant potential of some tumors may play an important role. Women should be better informed about this risk. Research should be oriented towards personalized screening and risk assessment tools.
Resumo:
Background: Breast cancer mortality has experienced important changes over the last century. Breast cancer occurs in the presence of other competing risks which can influence breast cancer incidence and mortality trends. The aim of the present work is: 1) to assess the impact of breast cancer deaths among mortality from all causes in Catalonia (Spain), by age and birth cohort and 2) to estimate the risk of death from other causes than breast cancer, one of the inputs needed to model breast cancer mortality reduction due to screening or therapeutic interventions. Methods: The multi-decrement life table methodology was used. First, all-cause mortality probabilities were obtained by age and cohort. Then mortality probability for breast cancer was subtracted from the all-cause mortality probabilities to obtain cohort life tables for causes other than breast cancer. These life tables, on one hand, provide an estimate of the risk of dying from competing risks, and on the other hand, permit to assess the impact of breast cancer deaths on all-cause mortality using the ratio of the probability of death for causes other than breast cancer by the all-cause probability of death. Results: There was an increasing impact of breast cancer on mortality in the first part of the 20th century, with a peak for cohorts born in 1945–54 in the 40–49 age groups (for which approximately 24% of mortality was due to breast cancer). Even though for cohorts born after 1955 there was only information for women under 50, it is also important to note that the impact of breast cancer on all-cause mortality decreased for those cohorts. Conclusion: We have quantified the effect of removing breast cancer mortality in different age groups and birth cohorts. Our results are consistent with US findings. We also have obtained an estimate of the risk of dying from competing-causes mortality, which will be used in the assessment of the effect of mammography screening on breast cancer mortality in Catalonia.
Resumo:
Background: During the last part of the 1990s the chance of surviving breast cancer increased. Changes in survival functions reflect a mixture of effects. Both, the introduction of adjuvant treatments and early screening with mammography played a role in the decline in mortality. Evaluating the contribution of these interventions using mathematical models requires survival functions before and after their introduction. Furthermore, required survival functions may be different by age groups and are related to disease stage at diagnosis. Sometimes detailed information is not available, as was the case for the region of Catalonia (Spain). Then one may derive the functions using information from other geographical areas. This work presents the methodology used to estimate age- and stage-specific Catalan breast cancer survival functions from scarce Catalan survival data by adapting the age- and stage-specific US functions. Methods: Cubic splines were used to smooth data and obtain continuous hazard rate functions. After, we fitted a Poisson model to derive hazard ratios. The model included time as a covariate. Then the hazard ratios were applied to US survival functions detailed by age and stage to obtain Catalan estimations. Results: We started estimating the hazard ratios for Catalonia versus the USA before and after the introduction of screening. The hazard ratios were then multiplied by the age- and stage-specific breast cancer hazard rates from the USA to obtain the Catalan hazard rates. We also compared breast cancer survival in Catalonia and the USA in two time periods, before cancer control interventions (USA 1975–79, Catalonia 1980–89) and after (USA and Catalonia 1990–2001). Survival in Catalonia in the 1980–89 period was worse than in the USA during 1975–79, but the differences disappeared in 1990–2001. Conclusion: Our results suggest that access to better treatments and quality of care contributed to large improvements in survival in Catalonia. On the other hand, we obtained detailed breast cancer survival functions that will be used for modeling the effect of screening and adjuvant treatments in Catalonia.